• Title/Summary/Keyword: Jang-ji

Search Result 5,156, Processing Time 0.03 seconds

Performance and Economic Analysis of Domestic Supercritical Coal-Fired Power Plant with Post-Combustion CO2 Capture Process (국내 초임계 석탄화력발전소에 연소 후 CO2 포집공정 설치 시 성능 및 경제성 평가)

  • Lee, Ji-Hyun;Kwak, No-Sang;Lee, In-Young;Jang, Kyung-Ryoung;Shim, Jae-Goo
    • Korean Chemical Engineering Research
    • /
    • v.50 no.2
    • /
    • pp.365-370
    • /
    • 2012
  • In this study, Economic analysis of supercritical coal-fired power plant with $CO_2$ capture process was performed. For this purpose, chemical absorption method using amine solvent, which is commercially available and most suitable for existing thermal power plant, was studied. For the evaluation of the economic analysis of coal-fired power plant with post-combustion $CO_2$ capture process in Korea, energy penalty after $CO_2$ capture was calculated using the power equivalent factor suggested by Bolland et al. And the overnight cost of power plant (or cost of plant construction) and the operation cost reported by the IEA (International Energy Agency) were used. Based on chemical absorption method using a amine solvent and 3.31 GJ/$tonCO_2$ as a regeneration energy in the stripper, the net power efficiency was reduced from 41.0% (without $CO_2$ capture) to 31.6% (with $CO_2$ capture) and the levelized cost of electricity was increased from 45.5 USD/MWh (Reference case, without $CO_2$ capture) to 73.9 USD/MWh (With $CO_2$ capture) and the cost of $CO_2$ avoided was estimated as 41.3 USD/$tonCO_2$.

Temperature-dependent Development and Its Model of the Greenbug, Schizaphis graminum (Rondani) (Homoptera: Aphididae) (보리두갈래진딧물 [Schizaphis graminum (Rondani)]의 온도발육과 발육모형)

  • Lee, Jang-Ho;Kim, Tae-Heung;Kim, Ji-Soo;Hwangn, Chang-Yeon;Lee, Sang-Guei
    • Korean journal of applied entomology
    • /
    • v.46 no.2
    • /
    • pp.213-219
    • /
    • 2007
  • The development of Schizaphis graminum (Rondani) was studied at various constant temperatures ranging from 15 to $32.5^{\circ}C$, with $65{\pm}5%$ RH, and a photoperiod of 16L:8D. Mortality of the $1_{st}-2_{nd}\;and\;the\;3_{rd}-4_{th}$ stage nymphs were similar at most temperature ranges while at high temperature of $32.5^{\circ}C$, more $3_{rd}-4_{th}$ stage individuals died. The total developmental time ranged from 13.8 days at $15^{\circ}C$ to 4.9 days at $30.0^{\circ}C$ suggesting that the higher the temperature, the faster the development. However, at higher end temperature of $32.5^{\circ}C$ the development took 6.4 days. The lower developmental threshold temperature and effective accumulative temperatures for the total immature stage were $6.8^{\circ}C$ and 105.9 day-degrees, respectively and the nonlinear shape of temperature related development was well described by the modified Sharpe and DeMichele model. The normalized cumulative frequency distributions of developmental period for each life stage were fitted to the three-parameter Weibull function. The attendance of shortened developmental times was apparent with $1_{st}-2_{nd}\;nymph,\;3_{rd}-4_{th}$ nymph, and total nymph stages in descending order. The coefficient of determination $r^2$ ranged between 0.80 and 0.87.

Effect of Low Night-time Temperature during Seedling Stage on Growth of Spring Chinese Cabbage (육묘기 야간 저온이 봄배추의 생육에 미치는 영향)

  • Lee, Jun-Gu;Lee, Ji-Weon;Park, Suh-Yung;Jang, Yoon-Ah;Oh, Sang-Seok;Seo, Tae-Cheol;Yoon, Hyeong-Kwon;Um, Young-Cheol
    • Journal of Bio-Environment Control
    • /
    • v.20 no.4
    • /
    • pp.326-332
    • /
    • 2011
  • The growth and bolting characteristics of spring Chinese cabbage cultivars at two night-time temperature treatments such as $5^{\circ}C$ and $10^{\circ}C$ during seedling stage were investigated to establish a safe environmental management strategy for raising seedlings. The low night-time temperature treatments were applied at 5, 10, and 15 days after sawing and the treatment durations were 5, 10, and 15 days in each of treatment beginning. The growth of seedlings in all the tested cultivars were linearly reduced as the treatment duration was extended and no symptoms of bolting were found. The reduction rate in seedling growth of 'Chunkwang' reached to 59.3% at most by 15 days of $5^{\circ}C$ treatment when it be compared to that of control. However, no symptoms of bolting were shown in the treatments of two night-time temperatures until the harvest at 90 days after sawing, indicating that the vernalization effect by low night-time temperature could be mitigated by subsequent day-time optimal temperature management. This study showed that the major spring Chinese cabbage cultivars require more ultimate level of low night-time temperature treatment for the vernalization than this study. It is also supposed that the optimal day-time temperature management can reduce or delay the rate of bolting, even if the seedlings were exposed to short-term low temperature below $5^{\circ}C$ during night-time.

Photosynthetic Characteristics and Cellular Tissue of Chinese Cabbage are Affected by Temperature and $CO_{2}C$ Concentration (온도와 $CO_{2}C$ 농도에 따른 배추의 광합성특성 및 세포조직의 변화)

  • Lee, Sang-Gyu;Moon, Ji-Hye;Jang, Yoon-Ah;Lee, Woo-Moon;Cho, Ill-Hwan;Kim, Seung-Yu;Ko, Kwan-Dal
    • Journal of Bio-Environment Control
    • /
    • v.18 no.2
    • /
    • pp.148-152
    • /
    • 2009
  • Numerous studies have presented evidence that global atmospheric carbon dioxide ($CO_{2}$ ) concentration and temperature is increasing every year. Both of the $CO_{2}$ and temperature are important components for photosynthesis activity of plants and thusgrowth and yield. However, little information is available in terms of the reaction of vegetable plants to increased $CO_{2}$ concentration and temperature, and also the reaction to a complex condition of both increased $CO_{2}$ concentration and temperature. The aim of this research was therefore to investigate changes in growth, photosynthetic activity and ultra-cellular structure of leaf tissue of Chinese cabbage. Plants were grown under either of elevated $CO_{2}$ concentration (elevated $CO_{2}$, 2-fold higher than atmospheric $CO_{2}$ ) or elevated temperature (elevated temp, 4$^{\circ}C$ higher than atmospheric temperature), under both of elevated $CO_{2}$ concentration and elevated temperature (elevated temp+$CO_{2}$), and under atmospheric $CO_{2}$ concentration and temperature (control). The treatment of 'elevated temp' negatively affected leaf area, fresh weight, chlorophyll and starch content. However, when the treatment of 'elevated temp' was applied coincidently with the treatment of 'elevated $CO_{2}$', growth and photosynthetic performance of plants were as good as those in the treatment of 'elevated $CO_{2}$', Microscopic study resulted that the highest starch content and density of cells were observed in the leaf tissue grown at the treatment of 'elevated $CO_{2}$', whereas the lowest ones were observed in the leaf tissue grown at the treatment of 'elevated temp'. These results suggest that when Chinese cabbage grows under a high-temperature condition, supplement of $CO_{2}$ would improve the growth and yield. In our knowledge, it is the first time to determine the effect of a complex relationship between the increased $CO_{2}$ concentration and temperature on the growth of Chinese cabbage.

Analysis of Relative Output Factors for Cyberknife: Comparison of Son Chambers, Diode Detector and Films (사이버나이프 출력인자 분석: 전리함, 다이오드 검출기 및 필름)

  • Jang Ji-Sun;Shin Dong-Oh;Choi Byung-Ock;Lee Tae-Kyu;Choi Ihl-Bohng;Kim Moon-Chan;Kwon Soo-Il;Kang Young-Nam
    • Progress in Medical Physics
    • /
    • v.17 no.1
    • /
    • pp.47-53
    • /
    • 2006
  • The accuracy of the dosimetry in the Cyberknife system is accomplishing important role from all processes of the stereotactic radiosurgery. In this study, we estimated relative output factors for Cyberknife. All measurements were peformed by six different detectors: diode detector, X-Omat V film, Gafchromic EBT film, 0.015 cc, 0.125 cc and 0.6 cc ionization chamber The diode detector and three ionization chambers peformed using water phantom at 80 cm SSD and 1.5 cm depth. When the film measurements were peformed, the water phantom was replaced with a solidwater phantom. Each collimator normalized with respect to the output factor of the largest collimator (60 mm). For the collimators over than 30 mm, the output factors from the different detectors showed a good agreement within 0.5% except 0.6 cc ion chamber For the collimators less than 15 mm, there were substantial differences In the output factors among different detectors. That is, the value of output factor for the 5 mm collimator of a diode and Gafchromic film was each $0.656{\pm}0.009$ and $0.777{\pm}0.013$. In the ion chamber and diode detector, those difference were due to the presence of large dose gradients and lack of electronic equilibrium in narrow megavoltage x-ray beams Therefore, the Gafchromic EBT film were considered more accurate than the others detectors.

  • PDF

HVL Measurement of the Miniature X-Ray Tube Using Diode Detector (다이오드 검출기를 이용한 초소형 X선관(Miniature X-ray Tube)의 반가층 측정)

  • Kim, Ju-Hye;An, So-Hyeon;Oh, Yoon-Jin;Ji, Yoon-Seo;Huh, Jang-Yong;Kang, Chang-Mu;Suh, Hyunsuk;Lee, Rena
    • Progress in Medical Physics
    • /
    • v.23 no.4
    • /
    • pp.279-284
    • /
    • 2012
  • The X ray has been widely used in both diagnosis and treatment. Recently, a miniature X ray tube has been developed for radiotherapy. The miniature X ray tube is directly inserted into the body irradiated, so that X rays can be guided to a target at various incident angles according to collimator geometry and, thus, minimize patient dose. If such features of the miniature X ray tube can be applied to development of X ray imaging as well as radiation treatment, it is expected to open a new chapter in the field of diagnostic X ray. However, the miniature X ray tube requires an added filter and a collimator for diagnostic purpose because it was designed for radiotherapy. Therefore, a collimator and an added filter were manufactured for the miniature X ray tube, and mounted on. In this study, we evaluated beam characteristics of the miniature X ray tube for diagnostic X ray system and accuracy of measuring the HVL. We used the Si PIN Photodiode type Piranha detector (Piranha, RTI, Sweden) and estimated the HVL of the miniature X ray tube with added filter and without added filter. Through an another measurement using Al filter, we evaluated the accuracy of the HVL obtained from a direct measurement using the automatic HVL calculation function provided by the Piranha detector. As a result, the HVL of the miniature X ray tube was increased around 1.9 times with the added filter mounted on. So we demonstrated that the HVL was suitable for diagnostic X ray system. In the case that the added filter was not mounted on, the HVL obtained from use of the automatic HVL calculation function provided by Piranha detector was 50% higher than the HVL estimated using Al filter. Therefore, the HVL automatic measurement from the Piranha detector cannot be used for the HVL calculation. However, when the added filter was mounted on, the HVL automatic measurement value using the Piranha detector was approximately 15% lower than the estimated value using Al filter. It implies that the HVL automatic measurement can be used to estimate the HVL of the miniature X ray tube with the added filter mounted on without a more complicated measurement method using Al filter. It is expected that the automatic HVL measurement provided by the Piranha detector enables to make kV-X ray characterization easier.

The Feasibility Study of MRI-based Radiotherapy Treatment Planning Using Look Up Table (Look Up Table을 이용한 자기공명영상 기반 방사선 치료계획의 타당성 분석 연구)

  • Kim, Shin-Wook;Shin, Hun-Joo;Lee, Young-Kyu;Seo, Jae-Hyuk;Lee, Gi-Woong;Park, Hyeong-Wook;Lee, Jae-Choon;Kim, Ae-Ran;Kim, Ji-Na;Kim, Myong-Ho;Kay, Chul-Seung;Jang, Hong-Seok;Kang, Young-Nam
    • Progress in Medical Physics
    • /
    • v.24 no.4
    • /
    • pp.237-242
    • /
    • 2013
  • In the intracranial regions, an accurate delineation of the target volume has been difficult with only the CT data due to poor soft tissue contrast of CT images. Therefore, the magnetic resonance images (MRI) for the delineation of the target volumes were widely used. To calculate dose distributions with MRI-based RTP, the electron density (ED) mapping concept from the diagnostic CT images and the pseudo CT concept from the MRI were introduced. In this study, the look up table (LUT) from the fifteen patients' diagnostic brain MRI images was created to verify the feasibility of MRI-based RTP. The dose distributions from the MRI-based calculations were compared to the original CT-based calculation. One MRI set has ED information from LUT (lMRI). Another set was generated with voxel values assigned with a homogeneous density of water (wMRI). A simple plan with a single anterior 6MV one portal was applied to the CT, lMRI, and wMRI. Depending on the patient's target geometry for the 3D conformal plan, 6MV photon beams and from two to five gantry portals were used. The differences of the dose distribution and DVH between the lMRI based and CT-based plan were smaller than the wMRI-based plan. The dose difference of wMRI vs. lMRI was measured as 91 cGy vs. 57 cGy at maximum dose, 74 cGt vs. 42 cGy at mean dose, and 94 cGy vs. 53 at minimum dose. The differences of maximum dose, minimum dose, and mean dose of the wMRI-based plan were lower than the lMRI-based plan, because the air cavity was not calculated in the wMRI-based plan. These results prove the feasibility of the lMRI-based planning for brain tumor radiation therapy.

Quantitative Evaluation of the Corticospinal Tract Segmented by Using Co-registered Functional MRI and Diffusion Tensor Tractography (정상인에서 기능적 뇌 자기공명영상과 확산텐서영상 합성기법을 이용한 피질척수로의 위치에 따른 정량적 분석)

  • Jang, Sung-Ho;Hong, Ji-Heon;Byun, Woo-Mok;Hwang, Chang-Ho;Yang, Dong-Seok
    • Investigative Magnetic Resonance Imaging
    • /
    • v.13 no.1
    • /
    • pp.40-46
    • /
    • 2009
  • Purpose : The purpose of this study was to investigate the quantitative evaluation of the corticospinal tract (CST) at the multiple levels by using functional MRI (fMRI) co-registered to diffusion tensor tractography (DTT). Materials and Methods : Ten normal subjects without any history of neurological disorder participated in this study. fMRI was performed at 1.5 T MR scanner using hand grasp-release movement paradigm. DTT was performed by using DtiStudio on the basis of fiber assignment continuous tracking algorithm (FACT). The seed region of interest (ROI) was drawn in the area of maximum fMRI activation during the motor task of hand grasp-release movement on a 2-D fractional anisotropy (FA) color map, and the target ROI was drawn in the cortiocospinal portion of anterior lower pons. We have drawn five ROIs for the measurement of FA and apparent diffusion coefficient (ADC) along the corona radiata (CR) down to the medulla. Results : The contralateral primary sensorimotor cortex (SM1) was mainly found to be activated in all subjects. DTT showed that tracts originated from SM1 and ran to the medulla along the known pathway of the CST. In all subjects, FA values of the CST were higher at the level of the midbrain and posterior limb of internal capsule (PLIC) than the level of others. Conclusion : Our study showed that co-registered fMRI and DTT has elucidated the state of CST on 3-D and analyzed the quantitative values of FA and ADC at the multiple levels. We conclude that co-registered fMRI and DTT may be applied as a useful tool for clarifying and investigating the state of CST in the patients with brain injury.

  • PDF

Anti-inflammatory and Antioxidant Effects of Spiraea prunifolia Sieb. et Zucc. var. simpliciflora Nakai in RAW 264.7 Cells (조팝나무 뿌리 열수 추출물이 RAW264.7 세포에서 미치는 항산화 및 항염증 활성)

  • Sim, Mi-Ok;Lee, Hyun Joo;Jang, Ji Hun;Lee, Hyo Eun;Jung, Ho-Kyung;Kim, Tae-Muk;No, Jong hyun;Jung, Jakyun;Jung, Da Eun;Cho, Hyun-Woo
    • Korean Journal of Plant Resources
    • /
    • v.30 no.4
    • /
    • pp.335-342
    • /
    • 2017
  • Spiraea prunifolia Sieb. et Zucc. var. simpliciflora Nakai (SSN) has been used for the anti-inflammation in traditional folk medicine. To compare water and methanol extracts of SSN, we analyzed major components using LC IT TOF MS. The major components of hot water extract were identified as caffeic acid and p-coumaric acid, but methanol extract was not well established. However, methanol extract was detected with less polarity compounds compared to hot water extract. Next, we investigated the inhibitory effects of SSN water extract on the lipopolysaccharide (LPS)-induced inflammatory response or $H_2O_2-induced$ oxidative stress in Raw 264.7 macrophage cells. SSN strongly suppressed the production of nitric oxide in LPS-induced inflammatory response without cytotoxcity. The SSN possessed free radical scavenging activities such as DPPH ($IC_{50}=320.2{\mu}g/m{\ell}$), ABTS ($IC_{50}=124.0{\mu}g/m{\ell}$), and superoxide anion radical ($IC_{50}=122.6{\mu}g/m{\ell}$). The total phenol and flavonoid content of SSN was 56.7 mg/g, and 15.1 mg/g, respectively. Furthermore, SSN decreased the $H_2O_2-induced$ cytotoxicity by enhancing the cell viability, and SSN significantly reduced the intracellular reactive oxygen species (ROS) level. Therefore, SSN may be recommended as an effective strategy to prevent and/or treat various inflammation and ROS-induced diseases.

BONE DENSITY AND HISTOMORPHOMETRY ASSESSMENT OF DENTAL IMPLANT USING COMPUTERIZED TOMOGRAPHY (컴퓨터 영상을 이용한 임플란트 식립부위의 골밀도와 조직학적 연구)

  • Son, Jang-Ho;Choi, Byung-Hwan;Park, Soo-Won;Cho, Yeong-Cheol;Sung, Iel-Yong;Lee, Ji-Ho;Byun, Ki-Jung
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.31 no.2
    • /
    • pp.136-142
    • /
    • 2009
  • Bone density in the recipient implant site seems to be an important factor for long term success of endosseous implants. Preoperative evaluation of bone density is very helpful to assist the clinician with the treatment planning of implant therapy. Accurate information on bone density will help the surgeon identify suitable implant sites, thereby improving the success rate of the procedure. Purpose; The aim of this study was to evaluate a correlation between bone density measured preoperatively with computerized tomography and histologically measured bone density by bone biopsy. Patients and methods; Twenty seven patients were selected. All the patients were in good health, with no systemic disorder and additional bone graft. Preoperatively the patients underwent CT scanning to evaluate Houmsfield Unit(HU). Each patients wore a surgical template for implant placement. During surgery 2mm in diameter and 6mm in length specimens were taken. Histomorphometric analysis was performed using digitalized image analysis software Axiovision 4.3. Also, the Resonance frequency analysis(RFA) and insertion torque values were recorded. Results; The highest histomorphometric values was found in the posterior mandible $32.3{\pm}3.8$, followed by $29.9{\pm}2.6$ for the posterior maxilla, $29.4{\pm}2.6$ for the anterior maxilla, $28.6{\pm}2.3$ for the anterior mandible(p=0.214). The hounsfield unit was $989.2{\pm}258.1$ in the posterior mandible, $845.0{\pm}241.5$ in the anterior maxilla, $744.5{\pm}92.6$ in the anterior mandible, $697.3{\pm}136.9$ in the posterior maxilla(p=0.045). This results may suggest that there are strong correlation between the histomorphometric values and hounsfield unit(r=0.760, p<0.05). The RF measurements were $81.9{\pm}2.4$ ISQ in the posterior mandible, $79.0{\pm}1.4$ ISQ in the anterior mandible, $78.3{\pm}4.6$ ISQ in the posterior maxilla, $76.5{\pm}5.0$ ISQ in the anterior maxilla(p=0.048). The insertion torque values was $43.2{\pm}4.2\;Ncm$ in the posterior mandible, $42.0{\pm}0.0\;Ncm$ in the anterior mandible, $41.3{\pm}4.1\;Ncm$ in the posterior maxilla, $40.8{\pm}3.8\;Ncm$ in the anterior maxilla(p=0.612). This results may suggest that there are statistical significance between the hounsfield unit and the insertion torque values(r=0.494, p<0.05), the histomorphometric values and the insertion torque values(r=0.689, p<0.05). But there was no correlation between histomorphometric values and ISQ. There was no statistical significance in age and gender effect on parameters. Conclusions; There was significant correlations between bone density and implant stability parameters. The bone density measurements using preoperative CT may help clinicians to predict primary stability before implant insertion, which is associated with implant survival rates.