• Title/Summary/Keyword: JIP analysis

Search Result 91, Processing Time 0.03 seconds

A Model Comparison Method for Hierarchical Loglinear Models

  • Hyun Jip Choi;Chong Sun Hong
    • Communications for Statistical Applications and Methods
    • /
    • v.3 no.3
    • /
    • pp.31-37
    • /
    • 1996
  • A hierarchical loglinear model comparison method is developed which is based on the well kmown partitioned likelihood ratio statistiss. For any paels, we can regard the difference of the geedness of fit statistics as the variation explained by a full model, and develop a partial test to compare a full model with a reduced model in that hierarchy. Note that this has similar arguments as that of the regression analysis.

  • PDF

SSD Power Consumption Analysis Tool (SSD 전력 소모 분석 도구)

  • Cho, Seok-Hei;Won, You-Jip
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2011.06b
    • /
    • pp.366-367
    • /
    • 2011
  • 오늘날 컴퓨터 시스템에서 중요하게 생각하는 분야 중 하나가 저전력이다. SSD는 기계적인 요소가 없어서 충격에 강하고 랜덤 읽기, 쓰기 성능이 HDD에 비해 좋아 HDD를 대체할 새로운 저장 장치로 여겨지고 있다. 또한 소모 전력도 HDD에 비해 작을 것으로 예측했다. 하지만 실제 소모량은 HDD와 크게 차이 나지 않았다. SSD의 소모 전력이 커진 원인을 파악하기 위해 SSD의 구성 요소를 파악하고 각 요소의 소모량을 시뮬레이터를 이용하여 분석했다. SSD의 전력 소모는 Flash Memory Controller, DRAM, NAND Flash 의 소모량이 90% 이상을 차지했다.

Tree-based Navigation Pattern Analysis

  • Choi, Hyun-Jip
    • Communications for Statistical Applications and Methods
    • /
    • v.8 no.1
    • /
    • pp.271-279
    • /
    • 2001
  • Sequential pattern discovery is one of main interests in web usage mining. the technique of sequential pattern discovery attempts to find inter-session patterns such that the presence of a set of items is followed by another item in a time-ordered set of server sessions. In this paper, a tree-based sequential pattern finding method is proposed in order to discover navigation patterns in server sessions. At each learning process, the suggested method learns about the navigation patterns per server session and summarized into the modified Rymon's tree.

  • PDF

Evaluation of High Order Statistical Parameter for Electrochemical Noise Analysis

  • Kim, Jong Jip
    • Corrosion Science and Technology
    • /
    • v.7 no.5
    • /
    • pp.296-299
    • /
    • 2008
  • High order statistical parameters were evaluated using the electrochemical noise data collected during corrosion of type 430 stainless steel coupled to a inert, platinum electrode in 3.5% NaCl solution. High order statistical parameters are shown to predict uniform corrosion properly. However, Localization index, skewness of current, kurtosis and skewness of potential are capable of predicting pitting corrosion only when the transients are large with long life time. Of the high order statistical parameters evaluated, kurtosis of current is found to be the most sensitive parameter for detecting uniform and pitting corrosion.

Phase Transition and Approximated Integral Equation for Radial Distribution Function

  • Yoon, Byoung-Jip;Jhon, Mu-Shik
    • Bulletin of the Korean Chemical Society
    • /
    • v.7 no.1
    • /
    • pp.20-23
    • /
    • 1986
  • A reduced condition for liquid-gas phase transition from the singularity of compressibility is derived using diagrammatic approach and is examined in the hard sphere system. The condition turns out that the Percus-Yevick and the Hyper-Netted-Chain approximation never conceive the idea of phase transition, and explains that the liquid-gas transition does not exist in hard sphere system. The solid-fluid transition is considered on the viewpoint of correlation function and diagrammatic analysis.

Theoretical Study on Structures and Energetics of Small Water Clusters

  • Park Yeong Jae;Kang Young Kee;Yoon Byoung Jip;Jhon Mu Shik
    • Bulletin of the Korean Chemical Society
    • /
    • v.3 no.2
    • /
    • pp.50-55
    • /
    • 1982
  • A study of small water clusters composed of two to seven molecules has been performed by using the revised empirical potential function for conformational analysis (REPFCA). Various structures of clusters have been investigated and the relative probability of cluster per molecule is discussed. In general, cyclic structures of water clusters are more favorable than open structures. It is found that cyclic pentamer is the most favorable unit structure in the water cluster.

Structural Analysis of Gas Generator Regenerative Cooling Chamber (재생냉각형 가스발생기 챔버 구조해석)

  • Ryu, Chul-Sung;Kim, Hong-Jip;Choi, Hwan-Seok
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.31 no.10
    • /
    • pp.1046-1052
    • /
    • 2007
  • Elastic-plastic structural analysis for regenerative cooling chamber of gas generator was performed. Uniaxial tension test was conducted for STS316L at room and high temperature conditions to get the material data necessary for the structural analysis of the chamber which was operated under thermal load and high internal pressure. Physical properties including thermal conductivity, specific heat and thermal expansion were also measured. The structural analysis for four different types of regenerative cooling chamber of gas generator revealed that increased cooling performance decreased the thermal load and strain of the cooling channel structure. The results propose that in order for the regenerative cooling gas generator chamber to have high structural stability with endurance to high mechanical and thermal loads, it is important for the chamber to be designed to have high cooling performance.

Acoustic Analysis for Design Optimization of Hub-Blade Baffle in Liquid Rocket Engine (액체로켓엔진에서 음향해석을 통한 허브-블레이드 배플 형상의 최적화)

  • Kim, Hong-Jip;Kim, Seong-Ku;Seol, Woo-Seok
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.8 s.227
    • /
    • pp.945-952
    • /
    • 2004
  • Acoustic characteristics of combustion chamber having various baffle configurations are numerically investigated by linear acoustic analysis to suggest reliable baffle specifications in first stage of KSLV-I. To determine the configuration of baffles, an acoustic modal analysis as well as the macroscopic analysis has been done. Hub has another effect of suppressing transverse acoustic mode by confining flow in baffled compartment over general effect of increase in acoustic damping of radial acoustic modes. So, a sufficient number of hub needs to be installed to obtain acoustic damping capacity. 3-blade configuration designed to suppress the first tangential mode has relatively low damping capacity, compared to 5 or 6-blade one. Optimum value of axial baffle length has been determined by comparing acoustic characteristics of combustion chamber having various baffle lengths.

Meta Analysis to Draw the Appropriate Regimen of Enzyme and Probiotic Supplementation to Pigs and Chicken Diets

  • Ohh, Sang-Jip
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.24 no.4
    • /
    • pp.573-586
    • /
    • 2011
  • Along with the recent changes in animal feed supply circumstances, many enzyme and probiotic feed supplements have been introduced and applied to pigs and chicken diets. Therefore, both selection of the appropriate feed supplements and their proper supplementation becomes critical to justify the supplementation. Meta-analysis was proposed as an appropriate tool to assess the large amount of relevant information. In this review, reliable data from recent publications was compounded then analyzed to determine the best practice of effective enzyme supplementation from the perspectives of animal species, age, characteristics of feed, target substrates, optimum multi enzymes combination and intended objectives. The results of the analysis suggested pratical methods of probiotic supplementation regarding intestinal microbiota, physiological limitation of probiotics, maximization of the probiotic benefit and synergism with prebiotic supplements.

Shaking Table Test of a Structure with Added Viscoelastic Dampers (점탄성 감쇠기가 설치된 구조물의 진동대 실험)

  • Kim., Jin-Koo;Kwon., Young-Jip
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.5 no.4
    • /
    • pp.197-203
    • /
    • 2001
  • This study presents the results of shaking table test of scaled model structures with added viscoelastic dampers, which are considered to be one of the most efficient means of upgrading existing structures against seismic loads. The experimental results were compared with those from analysis based on the linear modeling of viscoelastic dampers. The parameters obtained from free vibration test were utilized in the analysis. According to the results the added viscoelastic dampers turned out to be effective in reducing the responses of the model structures. It was also found that the analysis with linear modeling of viscoelastic dampers could simulate the test results accurately.

  • PDF