• Title/Summary/Keyword: JG-1a

Search Result 29, Processing Time 0.032 seconds

Measurement of Bubble Size in Flotation Column using Image Analysis System (이미지 분석시스템을 이용한 부선컬럼에서 기포크기의 측정)

  • An, Ki-Seon;Jeon, Ho-Seok;Park, Chul-Hyun
    • Resources Recycling
    • /
    • v.29 no.6
    • /
    • pp.104-113
    • /
    • 2020
  • Bubble size in froth flotation has long been recognized as a key factor which affects the bubble residence time, the bubble surface area flux (Sb) and the carrying rate (Cr). This paper presents method of bubble size measurement, relationship between operating variables and gas dispersion properties in flotation column. Using high speed camera and image analysis system, bubble size has been directly measured as a function of operating parameters (e.g., superficial gas rate (Jg), superficial wash water rate (Jw), frother concentration) in flotation column. Relationship compared to measured and estimated bubble size was obtained within error ranges of ±15~20% and mean bubble size was 0.718mm. From this system the empirical relationship to control the bubble size and distribution has been developed under operating conditions such as Jg of 0.65~1.3cm/s, Jw of 0.13~0.52cm/s and frother concentration of 60~200ppm. Surface tension and bubble size decreased as frother concentration increased. It seemed that critical coalescence concentration (CCC) of bubbles was 200ppm so that surface tension was the lowest (49.24mN/m) at frother concentration of 200ppm. Bubble size tend to increase when superficial gas rate (Jg) decreases and superficial wash water rate Jw and frother concentration increase. Gas holdup is proportional to superficial gas rate as well as frother concentration and superficial wash water rate (at the fixed superficial gas rate).

Study on the Electric Potentials at Biophysical Meridian System (경락 전위를 이용한 경락의 생체물리학적 연구)

  • Choi Hwan-Soo;Nam Bong-Hyun
    • Korean Journal of Acupuncture
    • /
    • v.19 no.2
    • /
    • pp.1-12
    • /
    • 2002
  • Objectives : Assuming That the Characteristic of Meridian System Has Been Similar to This of Electric Potentials in Human Body and That Measurements of Electric Potential at Well and Sea Points in Branches of the Twelve Meridians Will Be Representative of Measurements of the Twelve Meridians, to Measure the Electric Potentials in Healthy Volunteers(HG), Patients Diagnosed As a Cerebral Infarction(CG), a Arrhythmia(AG), a Other Intervertebral Disc Disorder(IG), and a Joint Disorder(JG), and Then to Find Out the Characteristic of Biophysical Meridian System, Finally to Compare with the Results of the Electric Potential in Those Groups. Methods : We Selected Who HG Were Diagnosed by a Blood Test, Urine Examination and Differentiation of Syndromes by Five Viscera among Volunteers, CG by CT and Wind-Syndrome Caused by Hyperactivity of the Liver-Yang, AG by EKG, CT, and Deficiency or the Heart Blood, IG by X-ray or CT and Pain in Waist, and JG by X-ray and Knee Pain. Their Electric Potential of Well and Sea Points in the Meridians Were Measured by hysiograph. Results and Conclusions : Measurements Were Analyzed by Factor Analysis, Analysis of Variance, and Logistic Regression Model, We Obtained That Most of the Results, In Conclusion, Hold Good for the Classical Meridian Doctrine.

  • PDF

Optimal Conditions for Pretreated Sample for Sr Isotope Analysis by MC-ICP-MS: A Comparison Between Eichrom (SR-R50-S)'s and Bio-Rad(AG®50W-X8)'s Resins (다검출기 유도결합 플라즈마 질량분석기에 의한 Sr 동위원소 분석을 위해 전처리된 시료의 최적 조건: Eichrom사 Sr 수지(SR-R50-S)와 Bio-Rad사 수지(AG®50W-X8) 비교)

  • Myoung Jung, Kim;Seung-Gu, Lee
    • Korean Journal of Mineralogy and Petrology
    • /
    • v.35 no.4
    • /
    • pp.507-520
    • /
    • 2022
  • The Sr isotope ratio, which is used as basic data for rock formation time, crustal and mantle evolution studies, is determined by mass spectrometer such as thermal ionization mass spectrometry (TIMS) or multi-detector inductively coupled plasma mass spectrometry (MC-ICP-MS). In this technical report, we compared how incomplete chemical separation of elements affects the determination of Sr isotope ratios. For the experiment, commercial resin, NBS987(NIST SRM987) Sr isotope standard, and rock standard samples from the Geological Survey of Japan (GSJ) such as JG1a, JB3 and JA1 were used. As a result of the comparative experiment, it was clearly observed that the measured values of 87Sr/86Sr change when Rb remains due to incomplete separation of the NBS987 Sr isotope standard sample as well as the rock standard samples of GSJ. This indicates that complete separation is an important factor since the calculated value deviates from the true value even though correction for isotope interference by isobar is performed when measuring the isotope ratio with MC-ICP-MS. This also suggests that, when reporting the measurement result of Sr isotope ratio using MC-ICP-MS, the measurement strength of 85Rb should be reported together with the measurement strength of all isotopes of Sr so that isotope interference by isobar can be judged.

Anticancer Effects of Ganjang with Different Aging Periods (숙성 기간에 따른 간장의 항암 효과)

  • Hur, Jinyoung;Kim, Min Jung;Hong, Sang Pil;Yang, Hye Jeong
    • Journal of the Korean Society of Food Culture
    • /
    • v.35 no.2
    • /
    • pp.215-223
    • /
    • 2020
  • Ganjang and doenjang are known as major fermented soy-based foods in Koreans. Current investigations have proved that fermented soybean foods impart anti-cancer, anti-obesity, and anti-diabetic effects. The aim of this study was to evaluate the anti-cancer activities of commercialized soy food, Ganjang, as a function of aging period. The test groups were classified into four time periods-short (under 5 years, S group), mid (under 10 years, M group), long (under 15 years, L group), and eternal (over 15 years, E group). The anti-cancer effects of Ganjang were determined by cell cytotoxicity assay of three types of cancer cell lines and splenocyte proliferation assay. Besides these assays, we also analyzed NK cell activity for cancer immunotherapy. The results show that the anti-cancer effect increased in the S and M period aging groups for all three cancer cell lines. Interestingly, similar to the anti-cancer result, splenocyte proliferation and NK activity showed the highest effect in the S and M groups. In contrast, Japanese ganjang-treated (JG1, JG2) groups and E group showed significantly reduced splenocyte proliferation. Collectively, these results suggest that the short and middle periods of traditional fermented Ganjang might have potential anti-cancer activities.

Designing of a Novel Core-Shell-Structured Co-free Cathode Material with Enhanced Thermal and Structural Stability for Lithium Ion Batteries

  • Shin, Ji-Woong;Nam, Yun-Chae;Son, Jong-Tae
    • Journal of the Korean Electrochemical Society
    • /
    • v.22 no.4
    • /
    • pp.172-176
    • /
    • 2019
  • The first commercialized cathode material, $LiCoO_2$, suffers from disadvantages such as high cost and toxicity and also possesses safety problems. The nickel-rich $LiNi_{0.9}Mn_{0.1}O_2$ cathode material, used as an alternative to $LiCoO_2$, has highly reversible capacity and high energy density. So, the nickel-rich $LiNi_{0.9}Mn_{0.1}O_2$ cathode material is widely used as an alternative to $LiCoO_2$ due to its highly reversible capacity and high energy density. However, $LiNi_{0.9}Mn_{0.1}O_2$ has several disadvantages as well, such as poor cycle performance and poor thermal instability. To address these problems, we synthesized a new material, $LiNi_{0.5}Mn_{0.5}O_2$, as a shell on the surface of a core to suppress the surface degradation. The new material showed high structural and thermal stabilities and could also maintain a high capacity. The capacity retention of the core-shell cathode (87.7%) was better than that of the core cathode (76.9%) after 50 cycles. Analysis using differential scanning calorimetry revealed that the heat generation in the core-shell cathode ($65.9Jg^{-1}$) was lower than that in the core cathode ($559.7Jg^{-1}$).

Optimization of different factors for an Agrobacterium-mediated genetic transformation system using embryo axis explants of chickpea (Cicer arietinum L.)

  • Sadhu, Suman Kalyan;Jogam, Phanikanth;Gande, Kranthikumar;Banoth, Raghu;Penna, Suprasanna;Peddaboina, Venkataiah
    • Journal of Plant Biotechnology
    • /
    • v.49 no.1
    • /
    • pp.61-73
    • /
    • 2022
  • In this study, we developed a reliable and efficient Agrobacterium-mediated genetic transformation system by applying sonication and vacuum infiltration to six chickpea cultivars (ICCV2, ICCV10, ICCV92944, ICCV37, JAKI9218, and JG11) using embryo axis explants. Wounded explants were precultured for 3 days in shoot induction medium (SIM) before sonication and vacuum infiltration with an Agrobacterium suspension and co-cultivated for 3 days in co-cultivation medium containing 100 µM/l of acetosyringone and 200 mg/l of L-cysteine. Responsive explants with putatively transformed shoots were selected using a gradual increase in kanamycin from 25 mg/l to 100 mg/l in selection medium to eliminate escapes. Results showed optimal transformation efficiency at a bacterial density of 1.0, an optical density at 600 nm wavelength (OD600), and an infection duration of 30 min. The presence and stable integration of the β-glucuronidase (gusA) gene into the chickpea genome were confirmed using GUS histochemical assay and polymerase chain reaction. A high transformation efficiency was achieved among the different factors tested using embryo axis explants of cv. JAKI 9218. Of the six chickpea cultivars tested, JAKI9218 showed the highest transformation efficiency of 8.6%, followed by JG11 (7.2%), ICCV92944 (6.8%), ICCV37 (5.4%), ICCV2 (4.8%), and ICCV10 (4.6%). These findings showed that the Agrobacterium-mediated genetic transformation system will help transfer novel candidate genes into chickpea.

Lead isotope measurement of geological reference materials using thermal ionization mass spectrometry (열이온화질량분석기를 이용한 암석표준시료에 대한 납 동위원소 분석)

  • Lee, Hyo Min;Jo, Hui Je;Kim, Taehoon
    • Analytical Science and Technology
    • /
    • v.33 no.6
    • /
    • pp.245-251
    • /
    • 2020
  • Lead (Pb) has been shown to be a useful tracer of contamination sources and geochemical processes such as age dating and crustal evolution. These studies require a chromatographic technique for Pb separation from geological samples. This paper presents a comparison study on the effect of eluent concentration between 6M HCl and 8M HCl on the separation of Pb from Pb resin. The results showed that the separation of Pb using 6M HCl as the eluent was not effective compared to the separation using 8M HCl. To verify this method, we measured the Pb isotopic compositions of the Pb isotopic standard (NIST NBS981) and geological reference materials (BCR-2, GSP-2, and JG-1a) using a thermal ionization mass spectrometer (TIMS). The results correspond well with the reported values within the error range, implying that this method can be useful.

Experimental study on flow pattern transitions for inclined two-phase flow (경사각 이상유동양식 천이에 관한 실험적 연구)

  • Kwak, Nam-Yee;Kim, Man-Woong;Lee, Jae-Young
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.3021-3026
    • /
    • 2007
  • In this paper, experimental data on flow pattern transition of inclination angles from 0-90 are presented. A test section is constructed 2 mm long and I.D 1inch using transparent material. The test section is supported by aluminum frame that can be placed with any arbitrary inclined angles. The air-water two-phase flow is observed at room temperature and atmospheric condition using both high speed camera and void impedance meter. The signal is sampled with sampling rate 1kHz and is analyzed under fully-developed condition. Based on experimental data, flow pattern maps are made for various inclination angles. As increasing the inclination angels from 0 to 90, the flow pattern transitions on the plane jg-jf are changed, such as stratified flow to plug flow or slug flow or plug flow to bubbly flow. The transition lines between pattern regimes are moved or sometimes disappeared due to its inclined angle.

  • PDF

Electrical and Chemical Properties of ultra thin RT-MOCVD Deposited Ti-doped $Ta_2O_5$

  • Lee, S. J.;H. F. Luan;A. Mao;T. S. Jeon;Lee, C. h.;Y. Senzaki;D. Roberts;D. L. Kwong
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.1 no.4
    • /
    • pp.202-208
    • /
    • 2001
  • In Recent results suggested that doping $Ta_2O_5$ with a small amount of $TiO_2$ using standard ceramic processing techniques can increase the dielectric constant of $Ta_2O_5$ significantly. In this paper, this concept is studied using RTCVD (Rapid Thermal Chemical Vapor Deposition). Ti-doped $Ta_2O_5$ films are deposited using $TaC_{12}H_{30}O_5N$, $C_8H_{24}N_4Ti$, and $O_2$ on both Si and $NH_3$-nitrided Si substrates. An $NH_3$-based interface layer at the Si surface is used to prevent interfacial oxidation during the CVD process and post deposition annealing is performed in $H_2/O_2$ ambient to improve film quality and reduce leakage current. A sputtered TiN layer is used as a diffusion barrier between the Al gate electrode and the $TaTi_xO_y$ dielectric. XPS analyses confirm the formation of a ($Ta_2O_5)_{1-x}(TiO_2)_x$ composite oxide. A high quality $TaTi_xO_y$ gate stack with EOT (Equivalent Oxide Thickness) of $7{\AA}$ and leakage current $Jg=O.5A/textrm{cm}^2$ @ Vg=-1.0V has been achieved. We have also succeeded in forming a $TaTi_x/O_y$ composite oxide by rapid thermal oxidation of the as-deposited CVD TaTi films. The electrical properties and Jg-EOT characteristics of these composite oxides are remarkably similar to that of RTCVD $Ta_2O_5, suggesting that the dielectric constant of $Ta_2O_5$ is not affected by the addition of $TiO_2$.

  • PDF

Evaluation of LA-ICP-MS Whole Rock Trace Element Analysis Using Fused Glass Bead of Silicate Rocks (규산염 암석의 알칼리 용융 유리원판에 대한 LA-ICP-MS 전암 미량원소 분석법 평가)

  • Kim, Myong Jung;Kim, Taehoon;Park, Kye-Hun;Lee, Ye Ji;Yang, Yun Seok;Moon, Jeongjin
    • The Journal of the Petrological Society of Korea
    • /
    • v.24 no.2
    • /
    • pp.141-147
    • /
    • 2015
  • Using laser-ablation inductively coupled plasma mass spectrometry (LA-ICP-MS), we evaluated the reliability of trace element abundance data measured from the silicate rock references of JR-3, JG-3, JGb-1 and JB-1b using glass discs made by alkali fusion. For 28 elements including rare earth elements, relative standard deviations (RSD) are better than 7% in case when the concentrations of the elements in the rock samples are greater than 10 ppm. However, RSD shows somewhat increased values for the concentrations less than 10 ppm, but never exceeds 25%. Compared with previously reported averages of the compiled abundance data, our data display satisfactory results for the most cases with differences less than 10%. We suggest that LA-ICP-MS analysis using fused glass beads is a reliable, precise and time-saving method of trace element analysis for the silicate rocks spanning from mafic to felsic compositions.