• Title/Summary/Keyword: JCI

Search Result 50, Processing Time 0.028 seconds

Comparison of Domestic and Foreign Standard Specifications on Form Design (국내외 표준 시방서의 거푸집 설계 관련 규정의 비교)

  • Jeon, Kyu-Nam;Choi, Sung-Yong;Baek, Dae-Hyun;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2010.05a
    • /
    • pp.29-31
    • /
    • 2010
  • This study investigated the typical standards of B kind of standard specification related to home and abroad forms design and compared them, and the results can be summarized as follows. In case of domestic standards, regulations on most forms design was described relatively in detail. and in case of CTEA among them, it included detailed contents of load conditions, lifting and subsidence. In case of abroad standards, the design regulations are only simply mentioned, not in detail, in ACI, CEB-FIP and BS, and JCI and JASS were similar to domestic KCI and KASS regulations. As to structural calculation in forms design regulations, most of domestic regulations included detailed matters on structural calculation, among them, CTEA shows the most detailed matters on it. On the other hand, it could be known that in case of abroad standards, most standards do not include matters on structural calculation except ACI, JCI and JASS.

  • PDF

Estimation of the Autogenous Shrinkage of the High Performance Concrete Containing Expansive Additive and Shrinkage Reducing Agent (팽창재와 수축저감제를 조차 사용한 고성능 콘크리트의 자기수축 해석)

  • Han, Min-Cheol
    • Journal of the Korea Institute of Building Construction
    • /
    • v.7 no.3
    • /
    • pp.123-130
    • /
    • 2007
  • This study investigated the fundamental properties and shrinkage properties of high performance concrete with water/binder ratio of 0, 30 and with combination of expansive additive and shrinkage reducing agent. According to the results, the fluidity of high performance concrete showed lower the using method in combination with expansive additive and shrinkage reducing agent than the separately using method of that, so the amount of superplasticizer increased when the adding ratio of expansive additive and shrinkage reducing agent increased. However the air content of concrete increased when used in combination with expansive additive and shrinkage reducing agent, so the amount of AE agent decreased. The compressive strength showed the highest at 5% of expansive additive, and decreased with an increase of the amount of shrinkage reducing agent. Furthermore, in order to reduce the shrinkage of high performance concrete, it was found that the using method in combination with expansive additive and shrinkage reducing agent was more effective than separately using method of that. Autogenous shrinkage was predicted using JCI model. Because JCI model is unable to consider the effect of EA and SRA, correction factor should be added to enhance the accuracy.

Clinical Nutrition Service in Korean Tertiary Hospitals and General Hospitals: Result of Nationwide Cross-Sectional Survey (국내 상급종합병원과 전국 분포 종합병원의 임상영양서비스 실태 조사 연구: 전국 규모 설문조사를 통하여)

  • Um, Mi Hyang;Park, Yoo Kyung;Lee, Song Mi;Lee, Seung Min;Lee, Eun;Cha, Jin A;Park, Mi Sun;Lee, Ho Sun;Rha, Mi Yong;Lyu, Eun Soon
    • Journal of the Korean Dietetic Association
    • /
    • v.20 no.3
    • /
    • pp.183-198
    • /
    • 2014
  • The purpose of this study was to investigate the status of clinical nutrition services provided at tertiary hospitals and general hospitals in Korea. In total, 157 questionnaires were distributed to the departments of nutrition at hospitals on September 2013. The results of this study are as follows. The median number of beds was 607 and average length of stay was 8 days. 63.1% of dietitians had over 5 years of career experience. Nutritional screening rate was 97% in tertiary hospitals but only 67.2% in general hospitals (P<0.001). The rate of equipment with computerized nutritional screening system was 100% in tertiary hospitals but 71.9% in general hospitals (P<0.001). Hospitals with the best regarding nutritional care were hospitals accredited by JCI (Joint Commission International). On the other hand, hospitals not accredited by the JCI but KOIHA (Korea Institute for Healthcare Accreditation) showed the lowest performance rate of nutritional care. Nutrition support teams (NSTs) were established in all tertiary hospitals but in only 73% of general hospitals (P<0.001). The rate of actively operating NSTs was 89% in tertiary hospitals but only 62% in general hospitals (P<0.001). There is a need to provide proper standardized clinical nutrition services as a primary treatment and we observed large variations in the quality of nutritional service between hospitals. Therefore, local solutions are needed to implement nutritional programs and policies for improved service and care.

An Experimental study on Autogenous Shrinkage strain of High-Strength Concrete (고강도 콘크리트의 자기수축 변형에 대한 실험적 연구)

  • 박신일;최진영;전철송;임병호;김화중
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2002.05a
    • /
    • pp.61-66
    • /
    • 2002
  • The autogenous shrinkage is a important phenomenon of high performance concrete since it may decrease the concrete member's durability by induce crack at early age. So the autogenous shrinkage behavior of high strength concrete was studied according to different replacement ratio of silica fume and fly ash. A linear measurement technique which was introduced by the JCI autogenous commitee was used.

  • PDF

Literature Study on the Durability Design Method of Reinforced Concrete Structure (철근콘크리트 구조물의 내구성 설계수법에 관한 문헌적 연구)

  • 신성우;이한승
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.04a
    • /
    • pp.421-426
    • /
    • 1999
  • The purpose of this study is to investigate the durability design method of reinforced concrete structure in order to establish a rationally combined design system of structural and durability design, that is to say performance-based design. In literature study, the integrated design of concrete structure studied JCI committe is very intensive durability design method for reinforced concrete structure. Specially, B root durability design method for selection of verification level is very effective method in the view of modeling of materials and structural properties to analyze safety and serviceability of RC structures.

  • PDF

Steel Fiber Reinforcing Effect Analysis of Slab Panel Structure and Assessment Technics of Toughness (강섬유보강 패널구조의 보강효과 분석 및 인성평가 기법)

  • Jeon, Chan-Ki;Park, Sun-Kyu
    • Magazine of the Korea Concrete Institute
    • /
    • v.11 no.2
    • /
    • pp.209-220
    • /
    • 1999
  • This paper is aimed to evaluate the effectiveness of flexural toughness of slab panel structures($60{\times}60{\times}10$) reinforced by steel fiber instead of wire mesh. Steel fiber used in this study is double hooked Dramix type fiber. And the fiber length is 60mm, diameter is 0.8mm, Various assessment methods of toughness index are used to estimate the proper effectiveness. In this experimental study, we find that Johnston, JCI-SF4 and EFNARC method are more effective to assess the flexural toughness of slab panels than the others. And the steel fiber is very effective alternative material to reinforce slab panel structures instead of wire mesh. Fiber volume fraction of 0.5~0.75% is more useful than the others in enhancing the post-peak energy absorption and toughness index by Johnston's $I_{5.5}$ assessment method. And the slab panels reinforcing with steel fiber are more resistant to crack propagation than wire mesh reinforcing slabs.

A Study on the Chloride ion Penetration Characteristic of Concrete containing Ground Granulated Blast Furnace Slag (고로슬래그미분말 치환 콘크리트의 염화물 침투특성에 관한 연구)

  • 김현수;지남용
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.05a
    • /
    • pp.997-1002
    • /
    • 2001
  • There are two types of chloride in concrete; one is added as concrete materials' chloride when concrete's mixing, and .the other is penetrated from the air and sea water in the sea-shore area. These chlorides penetrate into concrete, and they are accumulated inside the concrete with aging. This study aimed to evaluate the chloride ion penetration resistance of concrete containing GGBFS in the sea-shore area. Therefore, the specimens made with the replacement ratios(0, 0.30, 0.45, 0.60) of GGBFS were put into 3% NaCl solution according to the chloride accelerating test of JCI-SC3, and then investigated the weight changes, compressive strength, chloride ion with the depths of the specimens by aging. The result is that the diffusion coefficient of chloride ion is decreased with the increase of replacement ratios when compared to OPC

  • PDF

Review of Medical Services for Inbound Muslim Patients Associated with Global Healthcare Industry Activation - Focus on Nutrition Service - (글로벌헬스케어산업 활성화에 따른 방한 무슬림환자의 의료서비스에 관한 개관 -영양서비스를 중심으로-)

  • Bai, Young-Hee
    • Journal of the Korean Dietetic Association
    • /
    • v.21 no.4
    • /
    • pp.333-341
    • /
    • 2015
  • This article aimed to investigate problems relating to medical tourism based on a review of medical tourism reports and statistics in the global healthcare industry. To be a leading nation in the global healthcare industry, the needs and culture of many peoples, including Muslims, should be considered. Qualified medical services by JCI certification, including nutrition services, will provide opportunities to participate in the international and Asia medical tourism markets. In this article, the definitions of medical tourism, medical service, Halal and Haram, nutrition service for inbound Muslim patients, and Halal food supply in Korea were examined for medical service improvement. Mutual assistance between the government and private enterprise, sharing of medical service information, and construction of a cooperative network system are needed and should be supported by the government.

A Study on the Properties of Fiber Reinforced Porous Concrete for Pavement using Industrial By-product (산업부산물을 이용한 섬유보강 포장용 포러스콘크리트의 특성에 관한 연구)

  • Park Seong Bum;Lee Yoon Sun;Lee Jun;Jang Young Il;Kim Bong Kyun;Kim Jeong Hwan
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.11a
    • /
    • pp.699-702
    • /
    • 2005
  • This study evaluates the properties of porous concrete for pavement according to content of silica fume and steel fiber. The results of the test indicate that in every condition, the void ratio and the coefficient of water permeability of porous concrete for pavement satisfy both the domestic standards and proposition values. Among the properties of strength, the compressive strength satisfies the standards in the specification of KNHC as for every factor of mixture but in the case of the flexural strength, more than $0.6vol.\%$ of steel fiber satisfied the JCI proposition values. The case when silica fume and steel fiber are used simultaneously presents the strongest durability and Noise Reduction Coefficient is 0.48 to prove that it possesses almost $50\%$ sound absorption.

  • PDF

Bond Performance of Recycled PET Bottle Fiber Reinforced Concrete (폐 PET병을 이용한 콘크리트 보강 섬유의 부착특성)

  • Won, Jong-Pil;Park, Chan-Gi;Lee, Su-Jin;Kim, Jung-Hoon;Kim, Hwang-Hee;Lee, Jae-Young
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05b
    • /
    • pp.373-376
    • /
    • 2006
  • The purpose of this study was manufactured and evaluated the bond performance of recycled polyethylene terephthalate(PET) bottle fiber reinforced concrete. Four deformed recycled PET bottle fibers were manufactured and pullout test was conducted in accordance with the JCI-SF 8. Test parameters included four different type of fiber geometry and two types of mortar specimens. According to bond test results, it was found that embossing type recycled PET bottle fiber was significant improving the pullout load and interface toughness.

  • PDF