• 제목/요약/키워드: J-inverter

검색결과 406건 처리시간 0.03초

3상 PWM 전압형 인버터에 발생하는 누설전류와 동상모드 전압의 억제 (The Suppression of both leakage current and common-mode voltage occurring three phase PWM voltage type inverter)

  • 문상필;서기영;권순걸;김주용;김영문;김해제;김종실
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 B
    • /
    • pp.1515-1517
    • /
    • 2005
  • In this paper, we represent both occurrence reason of Surge-voltage and Leakage-current of AC drive system which is operated by Voltage-type PWM Inverter. It generates a compensating voltage which has the same amplitude as, but the opposite phase to, the common-mode voltage produced by the PWM inverter. The compensating voltage is superimposed on the inverter output by a common-mode transformer. As a result, the common-mode voltage applied to the load is canceled completely. The design method of the active common-mode noise canceler is also presented in detail. Therefore, we try to describe the method controling both of them and all of the proprieties are proved by our experiment.

  • PDF

인버터 열펌프의 주파수 및 모세관 길이 변화에 따른 시스템 성능특성의 실험적 연구 (An experimental study on the performance of inverter heat pump with a variation of frequency and capillary size)

  • 최종민;김용찬;김종엽;배영돈
    • 설비공학논문집
    • /
    • 제9권1호
    • /
    • pp.64-72
    • /
    • 1997
  • An experiment study was performed to investigate the optimum cycle of an inverter heat pump as a function of frequency. The performance of the inverter heat pump with the rated cooling capacity of 4141W(3550kcal/h) was measured with a variation of frequency, indoor and outdoor temperature, and length of capillary tube in the psychrometric test room. As a base case, the inverter heat pump with the standard capillary length of 1000mm which was optimum size for the frequency of 60Hz and ARHRAE Test condition A was tested by varying frequency from 30Hz to 80Hz. Then, the optimum cycle was invesigated by varying the length of capillary tube at each frequency levels of 30, 60 and 80Hz. Based on the experimental data, the change of system characteristics between the optimum and the base case were analyzed for each selected frequency levels. Generally, for low frequency level(30Hz), the longer length of the capillary tube compared with the standard size showed the higher EER, while for high frequency level(80Hz) the shorter length of the capillary tube showed the higher EER.

  • PDF

SRM의 여자전압제어를 위한 5-레벨 인버터 (5-Level Inverter for Excitation Voltage Control of SRM)

  • 이상훈;박성준;안진우
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 추계학술대회 논문집 학회본부 B
    • /
    • pp.294-296
    • /
    • 2000
  • Energy recovery in the regenerative region is very important when SRM(Switched Reluctance Motor) is used in traction drive. This is because that to reduce energy loss during mechanical braking and/or to have a high efficiency drive during braking. To control excitation voltage in motor operation and regenerative voltage in the generator operation in the SRM, multi-level voltage control is effective. This paper suggests multi-level inverter which is useful for motoring and regenerative operation in SRM.

  • PDF

35kJ/s 고전압 커패시터 충전장치 개발 (The Development of 35kJ/s High Voltage Capacitor Charger)

  • 장성록;류홍제;김종수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.988-989
    • /
    • 2008
  • This paper describes a rapid pulsed power charging system for pulsed power application. It is capable of charging 35kJ/s energy up to 0.47uF 25kV within 3ms and maximum pulse repetition rate of 300 pps can be achieved. The charger is designed based on three-phase series resonant inverter followed by air cooled set-up transformers thus it has many advantages of lower weight, small size and high efficiency compared with large bulky traditional pulse charger system. Detail design procedure of resonant inverter and high voltage transformers is explained. Experimental results carried out at different condition and its results shows 90% efficiency at full load condition.

  • PDF

현장 적용형 Mash seam 용접기의 개발 (Development of a Mash Seam Welder for the Factory Application)

  • 이왕하;박상국
    • 제어로봇시스템학회논문지
    • /
    • 제10권5호
    • /
    • pp.411-414
    • /
    • 2004
  • In this paper, a power controller and 3 phase voltage source inverter are proposed for the improvement of weldability of large scaler Mash seam welder. The welder system is designed for the low cost and the improvement of weldability. For this system, the thyristor convertor has performed constant current controlling in the output terminal by using PAM type inverter. We have simulated our algorithm and made a prototype welder for experiment. Through the experiment, we have confirmed the improvement of weldability of our system.

Grid-Connected Photovoltaic Inverter with Zero-Current-Switching

  • Choi Hang-Seok;Cho Y. J.;Kim J. D.;Cho B. H.
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 Proceedings ICPE 01 2001 International Conference on Power Electronics
    • /
    • pp.251-255
    • /
    • 2001
  • This paper presents a new zero current switching (ZCS) inverter for grid-connected photovoltaic system. The proposed circuit provides zero current switching condition for all the switches, which reduces switching losses significantly. It is controlled to extract maximum power from the solar array and to provide sinusoidal current into the mains. Analysis, small signal modeling and design procedure are presented. The validity of the proposed system is verified by experimental results from the 1.2kW prototype inverter operating at 40kHz.

  • PDF

ELEVATOR 구동용 VECTOR 제어 인버터 (Vector Controlled Inverter for Elevator Drive)

  • 신현주;장성영;이선재;이상동
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1991년도 하계학술대회 논문집
    • /
    • pp.627-630
    • /
    • 1991
  • This study is about vector controlled inverter for high quality elevator drive that is to improve the settling accuracy of elevator car and passenger's comfort in commercial buildings. In this study, an instantaneous space vector control type inverter was used to reduce the torque ripple ant to improve the velocity follow-up. This method calculates Instantaneous actual output torque and flux of induction motor by voltage and current, then compares them with a reference values by a speed regulator. The outputs of comparators select a switching mode, for an optimal voltage vector. Also, this study used IGBT (Insulated Gate Bipolar-Transistor), a high speed switching element, to reduce sound noise level, and DSP (Digital Signal Processor) was used to improve the reliability of the control circuit by fully digitalization.

  • PDF

2상 고주파 인버터에 의한 초음파 모터 제어 (Control of Ultrasonic Motor Using Two-Phase High Frequency Inverter)

  • 허정윤;조금배;백형래;오금곤;정헌상;유권종
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 A
    • /
    • pp.462-464
    • /
    • 1994
  • In this paper, noble electrical equivalent circuit ultrasonic motor is applied by model of parallel one from mechanical equation of piezoelectric device and characteristics estimation is done by equivalent converter. Uitrasonic motor is driven by oscillation circuit of two-phase high frequency inverter. Operating frequency of inverter is described by tracking control method of resonance frequency, according to change of load, temperature etc.

  • PDF

병렬공진형 직류 링크 인버터의 특성 개선에 관한 연구 (A Study on Improving Characteristics in the Parallel Resonant DC Link Inverter)

  • 백주원;유동욱;김종수;임근희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 A
    • /
    • pp.429-431
    • /
    • 1994
  • A parallel resonant dc link inverter, one of the many resonant inverters, has some superior characteristics in camparision with other resonant inverters. But loss of the resonant oscillation and occurrence of high peak voltage in the resonant capacitor of these inverters are serious problems. In this paper, we investigate a control method for resonant dc link inverters which can overcome these problems. Experimental results are presented to show superior operation of the resonant dc link inverter using the proposed control method.

  • PDF

인터넷 웹 기반 환경에서의 태양광용 인버터 원격제어시스템 개발에 관한 고찰 (Study of Internet Web-Based Photovoltaic Inverter Remote Control System)

  • 최주엽;조경신;최익;유권종;정영석;김기현
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 추계학술대회 논문집
    • /
    • pp.63-66
    • /
    • 2001
  • This paper aims at developing remote control system to control and monitor distributed various devices such as photovoltaic Inverter system through internet. TCP/IP (Transmission Control Protocol/Internet Protocol) and photovoltaic inverter system operated in a row are adopted for network management protocol and applied device, respectively. For controlling and monitoring distributed devices in real-time, java-environment software is constructed. Also, HelloDevice, general-use interface controller between network device and applied device is proposed. Finally, serial communication such as RS-232C is used between controller and applied device.

  • PDF