• Title/Summary/Keyword: J-inverter

Search Result 406, Processing Time 0.035 seconds

High Voltage Large Power Inverter for Induction Motor Drive (유도전동기 구동을 위한 고압 대용량 인버터)

  • Park, S.S.;Jung, J.J.;Kim, W.M.;Liu, H.Y.;Seong, H.H.;Cho, G.H.
    • Proceedings of the KIEE Conference
    • /
    • 1994.07a
    • /
    • pp.450-454
    • /
    • 1994
  • From a point of view in energy saving and improvement of productivity, inverter for large power induction motor drive is very important. In this thesis, we developed high voltage inverter for large power induction motor drive. We experimented the inverter with R-L series load, successfully, and are going to do the field test in the real plant.

  • PDF

A Study on Fuel Cell Inverter Operation for Distributed Generation (분산전원용 연료전지 인버터 운전에 관한 연구)

  • Jang S.J.;Lee T.W.;Song S.H.;Kim J.H.;Won C.Y.;Kim Y.H.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07b
    • /
    • pp.981-986
    • /
    • 2003
  • Recently, a fuel cell is remarkable for new generation system. The fuel cell generation system converts the chemical energy of a fuel directly into electrical energy. The fuel cell generation is characterized by low voltage and high current. For connecting to utility, it needs both a step up converter and an inverter. The step up converter makes DC link and the inverter changes D.C to A.C. In this paper, full bridge converter and the single phase inverter are designed and installed for fuel cell. Simulation and experiment verify that fuel cell generation system could be applied for the distributed generation.

  • PDF

3-Phase Pseudo-Random Carrier Modulation Technique for the Acoustic Noise Reduction of the 3-Phase Multi-Level Inverter Based Motor (3상 멀티 레벨 인버터 구동 유도 전동기의 소음저감을 위한 3상 준 랜덤 캐리어 변조기법)

  • Park, J.K.;Kim, J.N.;Jung, Y.G.;Lim, Y.C.
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.742-745
    • /
    • 2005
  • This paper describes a simple pseudo-random carrier modulation technique for the acoustic noise reduction of the three phase multi-level inverter based motor drives. The proposed method generates a new pseudo-random carrier by randomly synthesizing a carrier with fixed frequency and a carrier with opposition phase. To confirm the validity of the proposed method, a 130v three-phase multi-level inverter was Implemented and tested. The experimental results show that the output line voltage and acoustic noise harmonics spectra of an inverter have broadening effect of harmonics, as only simple synthesis of fixed frequency carries.

  • PDF

A Study on the Torque Control of Induction Motor using Voltage Source Inverter without speed Sensor (전압형 Inverter에 의한 속도검출기 없는 유도전동기 속도제어)

  • Hwang, L.H.;Kim, J.I.;Jang, B.G.;Lee, S.Y.;Na, S.K.;Kim, J.L.;Lee, C.S.;Cho, M.T.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.1130-1132
    • /
    • 2000
  • In this paper, For Control of the speed sensorless induction motor propose the method which is controled the motor by operating two axis current in input current of the inverter. This method determines frequency of inverter in order to stator electromotive force and E/F ratio for the setting magnetic flux, drives for speed control using a voltage power converter of the induction motor by means of voltage fed converter with current control ability.

  • PDF

Development of Inverter for Elevator Door Control (엘리베이터 자동문제어 인버터 개발)

  • Kim, J.K.;Choi, U.D.;Jung, M.K.;Choi, S.K.;Yun, J.H.;Han, S.B.
    • Proceedings of the KIEE Conference
    • /
    • 1995.07a
    • /
    • pp.308-310
    • /
    • 1995
  • Most of the elevator door controllers have been controlled by DC Motors as an actuator. Recently, The control system using AC induction motor and general purpose inverter has been applied to control of elevator door. But there are some difficulties in making use of this system, such as adjustment of door speed pattern, door open-close time, and security of passenger safety. In order to solve these problems, a special inverter has, been developed with an encoder feedback. From the result of field-test, we proved that a special inverter with encoder feedback device has come to considerable effect. Until now about 1,200 sets of these inverters are operated in Korea and about 100 sets are operated in South-east Asia.

  • PDF

A Study on Digital control of Inverter for UPS based on Disturbance Observer (외란관측기를 가지는 UPS용 인버터의 디지탈제어에 관한 연구)

  • Lee, C.D.;Kim, J.S.;Choi, S.Y.;Lee, J.C.;Woo, J.I.
    • Proceedings of the KIEE Conference
    • /
    • 1996.07a
    • /
    • pp.606-608
    • /
    • 1996
  • In this paper, a new control scheme based on deadbeat control with disturbance observer for voltage controlled Inverter system is proposed. The inverter system is modelled as the 4th-order system treating R load current variation caused by disturbance. So the disturbance observer exists in the state observer. By using the pole placement strategy, the observer estimates the state and disturbance variable of the next sampling instant. Simulation results so show that The proposed scheme has robust feature against disturbance.

  • PDF

Internal Model Control of UPS Inverter using Resonance Model

  • Park J. H.;Kim D. W.;Kim J. K.;Lee H. W.;Noh T. K.;Woo J. I.
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.184-188
    • /
    • 2001
  • In this paper, a new fully digital control method for single-phase UPS inverter, which is based on the double control loop such as the outer voltage control loop and inner current control loop, is proposed. The inner current control loop is designed and implemented in the form of internal model control and takes the presence of computational time-delay into account. Therefore, this method provides an overshoot-free reference-to-output response. In the proposed scheme, the outer voltage control loop employing P controller with resonance model implemented by a DSP is introduced. The proposed resonance model has an infinite gain at resonant frequency, and it exhibits a function similar to an integrator for AC component. Thus the outer voltage control loop causes no steady state error as regard to both magnitude and phase. The effectiveness of the proposed control system has been demonstrated by the simulation and experimental results respectively.

  • PDF

A Study on The Broken Rotor Bars in Induction Motor and The Control Characteristics in Inverter

  • Kim K. W.;Lee K. J.;Kwon J. L.;Kim J. K.;Choi K. S.;Lee H. S.;Chang S. G.
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.365-368
    • /
    • 2001
  • The advantage of the squirrel cage induction motor is the brush less rotor. This advantage for operation and maintenance turns out to be a disadvantage for the detection of the cage rotor bar and endring defects, which means that the detection of cage faults is due to the measurement and analysis of only the stator input signals. The monitoring task in an inverter drive is complicated mainly because the voltage and current waveforms are nonsinusoidal and the high dv/dt values from fast switching inverterd distort the measurements. In this paper, we are going to discuss the detection method of broken rotor bar of the inverter fed squirrel cage induction motor by the motor current signature analysis(MCSA) and the opening terminal voltage signal analysis.

  • PDF

A study on digital signal method of PWM signal by switching position function (PWM 신호의 스위칭 함수에 의한 디지탈 방식에 관한 연구)

  • Chung, Y.T.;Lee, J.S.;Bae, S.J.;Baek, J.H.
    • Proceedings of the KIEE Conference
    • /
    • 1988.07a
    • /
    • pp.148-150
    • /
    • 1988
  • The output characteristics of VSI by transistor depend upon bias signal with drive circuit. As the CTI is one of the VSI, takes case PWM output voltage. This Inverter operation is based upon position and negative of sinusoldal PWM signal by carrier triangular wave and compared sine one. Besides, the Inverter operation system required digital signal for microprocessor, sampling method of Inverter driver signals study for get rid of generated signal is error. In the paper, the method of 3 level PWM signal for CTI was studied. This method of signals depend upon caculated switching position of natural sampling with $10^{-6}$ modulation error for time flowchart programs.

  • PDF