• Title/Summary/Keyword: Isotope dilution mass spectrometry (ID-MS)

Search Result 32, Processing Time 0.026 seconds

Optimization of Microwave-Assisted Method for Accelerated Glycated Hemoglobin Quantification from Amino Acids to Proteins

  • Tran, Thi Thanh Huong;Jeong, Ji-Seon
    • Mass Spectrometry Letters
    • /
    • v.8 no.3
    • /
    • pp.53-58
    • /
    • 2017
  • Glycated hemoglobin ($HbA_{1c}$) has been commonly used to screen and diagnose for patients with diabetes mellitus. Here the accelerated procedure of microwave-assisted sample treatment from acid hydrolysis to enzyme digestion followed by isotope dilution liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS) was optimized and applied to measure $HbA_{1c}$ in an effort to speed up analysis time. First, two signature peptides of $HbA_{1c}$ and hemoglobin $A_0$ were certified with amino acid analysis by setting optimized acid hydrolysis conditions to $150^{\circ}C$, 1.5 h and $10{\mu}M$ sample concentration in 8 M hydrochloric acid. Consequently, the accurate certified peptides above were used as calibration standards to implement the proteolytic procedure with endoproteinase Glu-C at $37^{\circ}C$, 700 W for 6 h. Compared to the traditional method, the microwave heating not only shortened dramatically sample preparation time, but also afforded comparable recovery yields. The optimized protocol and analytical conditions in this study are suitable for a primary reference method of $HbA_{1c}$ quantification with full SI-traceability and other similar proteins in complex biological samples.

An analysis of benzoic acid, methyl paraben and butyl paraben in soy sauce using isotope dilution liquid chromatography mass spectrometry (동위원소희석 질량분석법을 이용한 간장 중의 안식향산, 메틸파라벤, 부틸파라벤의 분석)

  • Ahn, Seonghee
    • Analytical Science and Technology
    • /
    • v.31 no.6
    • /
    • pp.225-231
    • /
    • 2018
  • Benzoic acid, methyl paraben, and butyl paraben are preservatives that have been used in pharmaceutical, cosmetic, and food products. However, as their toxicities for human have been reported, many nations and organizations including Korea have established a regulation limit for thier usage of these preservatives in food products. The present study developed the isotope dilution liquid chromatography mass spectrometry method for accurate determination of three target preseratives in soysauce. In this study, the isotope dilution liquid chromatography mass spectrometry method was developed for accurate determination of three target preservatives in soy sauce. LC separation was optimized considering the pKa of benzoic acid which is lower than those of methyl and butyl parabens. A C18 column was used with 5 mM ammonium acetate and methanol as mobile phases. Mass spectrometry was operated in negative mode and selected reaction monitoring mode (SRM). Soy sauce sample was cleaned-up with C18 SPE cartridge for removing matrix inferences and color material. Optimized conditions and the method were validated with soy sauce reference materials for the analysis of food preservatives from Health Science Authority in Singapore. The measured values of benzoic acid, methyl and butyl paraben agreed well with reference values within their uncertainties.

Quantification of cholesterol in human serum by isotope dilution liquid chromatography/mass spectrometry (동위원소희석 액체크로마토그래피/질량분석법에 의한 혈청 내 콜레스테롤의 정량)

  • Shin, Hyesun;Lee, Hwashim;Lee, Gaeho
    • Analytical Science and Technology
    • /
    • v.21 no.6
    • /
    • pp.502-509
    • /
    • 2008
  • An ID LC/MS (isotope dilution liquid chromatography/mass spectrometry) was used as a primary method for the quantitative analysis of cholesterol in human serum. The separation of cholesterol was carried out by Thermo ODS hypersil $C^{18}$ column. The mobile phase was 100% methanol, and flow rate was $0.3m{\ell}/min$. Cholesterol and cholesterol-$3,4-13C_2$ were monitored at m/z 369.4 and 371.3, which correspond to $[M-H_2O+H]^+$ respectively. In order to verify the measurement method, NIST SRM 909b was analyzed. The results agreed well with certified values within uncertainty. The four kinds of serum certified reference material were prepared and certified. The repeatabilities of measurement were ranged from 0.1 to 0.8% (RSD), which were relatively good. The reproducibility between independent measurement run was below 0.24% (RSD). The expanded uncertainty was about 1.43% within the 95% confidence interval.

Analysis of sorbic acid in tea-drink using isotope dilution liquid chromatography tandem mass spectrometry (ID-LC/MS/MS) (동위원소희석 액체 크로마토그래피-질량분석법을 이용한 차음료 중의 소르빈산의 분석)

  • Ahn, Seong-Hee;Lee, In-Sun;Kim, Byung-Joo
    • Analytical Science and Technology
    • /
    • v.25 no.1
    • /
    • pp.25-32
    • /
    • 2012
  • Isotope dilution mass spectrometry (ID-MS) based on liquid chromatography tandem mass spectrometry (LC/MS/MS) was developed for the accurate determination of sorbic acid in tea-drink. An isotope analogue of sorbic acid, $^{13}C_2$-sorbic acid, was obtained by custom synthesis. MS was operated in the negative mode with selected reaction monitoring (SRM) mode of $[M-H]^-$ ${\rightarrow}$ $[M-CO_2H]^-$ channel at m/z 111 ${\rightarrow}$ 67 for sorbic acid and at m/z 113 ${\rightarrow}$ 68 for its isotope analogue. Chromatographic separation was accomplished with a C18 column and an isocratic mobile phase of 55% of 50 mM ammonium acetate (pH 4.5) and 45% of methanol. Homogeneous reference materials were prepared for validation of this method, including repeatability and reproducibility tests, by fortifying tea-drink with sorbic acid in our laboratory. Repeatability and reproducibility studies showed that the ID-LC/MS method is a reliable and reproducible method which provides less than 3.8% of relative standard deviation (RSD) for the analysis of sorbic acid.

Study of improving precision and accuracy by using an internal standard in post column isotope dilution method for HPLC-ICP/MS (후 컬럼 동위원소 희석법을 적용한 HPLC-ICP/MS에서의 정량분석에서 내부 표준물을 이용한 정확도와 정밀도의 개선연구)

  • Joo, Mingyu;Park, Myungsun;Pak, Yong-Nam
    • Analytical Science and Technology
    • /
    • v.27 no.3
    • /
    • pp.140-146
    • /
    • 2014
  • An internal standard was used in PCID (post column isotope dilution) to improve the accuracy and precision in quantification of various chemical species. The error occurring in the column was the largest in HPLC-ICP/MS (high performance liquid chromatography-inductively coupled plasma/mass spectrometry) when PCID and other traditional quantification methods were compared with each other. Internal standard was effective in correcting the loss of sample in the column to improve accuracy and precision. When applied to SeMet, using MeSecys or $Se^{4+}$ as an internal standard, relative errors were reduced from 31% and 13% to less than 1%, while standard deviations were reduced from 5.1% and 6.9% to 1.5% and 0.2%, respectively. Positive aspects of using an internal standard in PCID were compared with other quantitative techniques and discussed in detail.

Development of a Nutritional Supplement Certified Reference Material for Elemental Analysis

  • Lee, Jong Wha;Heo, Sung Woo;Kim, Hwijin;Lim, Youngran;Lee, Kyoung-Seok;Yim, Yong-Hyeon
    • Mass Spectrometry Letters
    • /
    • v.9 no.4
    • /
    • pp.105-109
    • /
    • 2018
  • A certified reference material (CRM) for the analysis of inorganic nutrients in nutritional supplements has been developed. Accurate mass fractions of chromium (Cr), iron (Fe), copper (Cu), and zinc (Zn) were determined by isotope dilution inductively coupled plasma mass spectrometry (ID ICP/MS). The measurement results were used to assign certified values for the CRM, which were metrologically traceable to the definitions of the measurement units in the International System of Units (SI). Production of a candidate reference material (RM) and the certification processes are summarized. Each nutrient in the CRM showed good homogeneity, which was estimated using relative standard deviations of the measurement results of twelve bottles in a batch. This CRM is expected to be an important reference to improve reliability and comparability of nutrient analyses in nutritional supplements and related samples in analytical laboratories.

Quantitative Analysis of Isoflavones and Lignans in Sea Vegetables Consumed in Korea Using Isotope Dilution Gas Chromatography-Mass Spectrometry

  • Lee, Young-Joo;Adlercreutz, Herman;Kwon, Hoon-Jeong
    • Food Science and Biotechnology
    • /
    • v.15 no.1
    • /
    • pp.102-106
    • /
    • 2006
  • The phytoestrogens including isoflavones (genistein, daidzein, biochanin A, formononetin, and glycitein), coumestrol, and lignans (secoisolariciresinol, matairesinol, and anhydrosecoisolariciresinol) were quantified in edible sea vegetables from Korea. Sea vegetable samples were collected based on domestic consumption data. After hydrolysis of phytoestrogen glycosides in prepared samples, aglycones of phytoestrogens were extracted with diethyl ether and analyzed with isotope dilution gas chromatography-mass spectrometry in selected ion monitoring mode (ID-GC-MS-SIM). Total samples included 19 samples representing eight species. Most of the samples showed rather low concentrations, ranging from not determinated to $79.2\;{\mu}g/kg$ for isoflavones and from 106.4 to $694.8\;{\mu}g/kg$ for lignans. The daily intake of phytoestrogen from sea vegetables, estimated from the present data and domestic consumption data, was about $0.13\;{\mu}g/day$ for isoflavones and $2.0\;{\mu}g/day$ for lignans. When we compared these results with those from legumes, sea vegetables would not be considered the major source of phytoestrogens in the Korean diet.

Development of Isotope Dilution-Liquid Chromatography/Tandem Mass Spectrometry as a Candidate Reference Method for the Determination of Folic Acid in Infant Milk Formula

  • Jung, Min-Young;Kim, Byung-Joo;Boo, Doo-Wan;So, Hun-Young
    • Bulletin of the Korean Chemical Society
    • /
    • v.28 no.5
    • /
    • pp.745-750
    • /
    • 2007
  • An isotope dilution-liquid chromatography/tandem mass spectrometric method was developed as a candidate reference method for the accurate determination of folic acid in infant milk formula. Sample was spiked with 13C5-folic acid and then extracted with phosphate buffer (pH 6) solution. The extract was further cleaned up by deproteinization followed by a C18 solid-phase extraction cartridge. The extract was analyzed by using LC/ ESI/MS/MS with selectively monitoring the collisionally induced dissociation channels of m/z 442 → m/z 295 and m/z 447 → m/z 295, which are the neutral glutamyl loss from the [M+H]+ ions of folic acid and 13C5-folic acid, respectively. LC/MS/MS chromatograms showed substantially reduced background from chemical noises compared to LC/MS chromatograms. Repeatability and reproducibility studies showed that the LC/MS/ MS method is a reliable and reproducible method which can provide less than 1.5 relative percentage of method precision.

Accurate determination of chloramphenicol in meat by isotope dilution liquid chromatography mass spectrometry (ID-LC/MS) (동위원소희석 액체크로마토그래피-질량분석법을 이용한 육류 중 클로람페니콜의 정밀한 정량 분석에 관한 연구)

  • Song, Hye-Min;Kim, Byung-Joo;Jeong, Hyuk;Ahn, Seong-Hee
    • Analytical Science and Technology
    • /
    • v.23 no.6
    • /
    • pp.524-530
    • /
    • 2010
  • Chloramphenicol is one of the most effective antibiotics for treatment of food-producing animals for typhoid fever. However, it has been reported that it caused severe side effects such as aplastic anemia in human, therefore the use of chloramphenicol for food-producing animal is prohibited by European Union and other countries. In this study, the analytical method using isotope dilution liquid chromatography-mass spectrometry (ID-LC/MS) was established for accurate determination of chloramphenicol in meat. Chloramphenicol was extracted with ethylacetate from porcine and solid phase extraction cartridge was used for enhancing the recovery. The residue of chloramphenicol in porcine was analyzed using the liquid chromatography mass spectrometer (LC/MS) interfaced with electrospray ionization source. Analysis was performed in negative mode with selected reaction mornitoring mode at m/z 321${\rightarrow}$257 of $[M-H]^-$ ${\rightarrow}$ $[M-H-(HCOCl)]^-$ and m/z 326 ${\rightarrow}$ 262 channels for its isotope. The established method was tested using fortified samples at the level of 0.2 1, 10, $25\;{\mu}g$/kg and analytical results agreed with the gravimetrically fortified values within their uncertainties. This method was validated by analyzing a certified reference material, BCR 445, from IRMM (Institute for Reference Materials and Measurement). Our measurement values agreed with the certified value within their uncertainties. The uncertainty of our measured value was much lower than that the certified value from IRMM.

Development of Isotope Dilution-Liquid Chromatography/Tandem Mass Spectrometry as a Candidate Reference Method for the Determination of Acrylamide in Potato Chips

  • Park, Sun-Young;Kim, Byung-Joo;So, Hun-Young;Kim, Yeong-Joon;Kim, Jeong-Kwon
    • Bulletin of the Korean Chemical Society
    • /
    • v.28 no.5
    • /
    • pp.737-744
    • /
    • 2007
  • An isotope dilution-liquid chromatography/tandem mass spectrometric method was developed as a candidate reference method for the accurate determination of acrylamide in potato chips, starch-rich foodstuff cooked at high temperature. Sample was spiked with 13C3-acrylamide and then extracted with water. The extract was further cleaned up with an Oasis HLB solid-phase extraction (SPE) cartridge and an Oasis mixed-phase cation exchange (MCX) SPE cartridge. The extract was analyzed by using LC/ESI/Tandem MS in positive ion mode. LC with a medium reversed-phase (C4) column was optimized to obtain adequate chromatographic retention and separation of acrylamide. MS was operated to selectively monitor [M+H]+ ions of the analyte and its isotope analogue at m/z 72 and m/z 75, respectively. Sample was also analyzed by the LC/MS with selectively monitoring the collisionally induced dissociation channels of m/z 72 → m/z 55 and m/z 75 → 58. Compared to the LC/MS chromatograms, the LC/MS/MS chromatograms showed substantially reduced background chemical noises coming from solvent clusters formed during ESI spray processes and interferences from sample matrix. Repeatability and reproducibility studies showed that the LC/MS/MS method is a reliable and reproducible method which can provide a typical method precision of 1.0% while the LC/MS results are influenced by chemical interferences.