Hybrid fault detection and isolation for uncertainty system (불확실성을 고려한 시스템에서의 복합형 이상검출 및 격리)

  • 유호준;김대우;권오규
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1997.10a
    • /
    • pp.1432-1435
    • /
    • 1997
  • This paper proposes a fault detection and isolation metho by combining the parameter estimation method[4] with the observer method[2] to use merits of both methods. To verify the performance of the method proposed some simulations applied to remotely piloted vehicle are performed.

  • PDF

Development of a Practical Two-Microphone Impedance Tube Method for Sound Transmission Loss Measurement of Sound Isolation Materials

  • Ro, Sing-Nam;Hwang, Yoon;Lee, Dong-Hoon
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.11 no.3
    • /
    • pp.105-113
    • /
    • 2003
  • This study developed a practical two-microphone impedance tube method to measure the sound transmission loss of sound isolation materials without the use of an expensive reverberation room or an acoustic intensity probe. In order to evaluate the validation and applicability of the two-microphone impedance tube method, sound transmission losses for several sound isolation materials with different surface density and bending stiffness were measured, and the measured values were compared with the results from the reverberation room method and the theory. From the experimental results, it was found that the accuracy of sound transmission loss obtained by the impedance tube method depends upon the diameter size of the impedance tube (i.e., tested sample size). For sound isolation materials having relatively large bending stiffness such as acryl, wood, and aluminum plates, it was found that the impedance tube method proposed by this study was not valid to measure the sound transmission loss. On the other hand, for sound isolation materials having relatively small bending stiffness such as rubber, polyvinyl, and asphalt sheets, the comparisons of transmission loss between the results from the impedance tube method and the theory showed a good agreement within the range of the frequencies satisfying the normal incidence mass law. Therefore, the two-microphone impedance tube method proposed by this study can be an effective measurement method to evaluate the sound transmission loss for soft sound isolation sheets having relatively small bending stiffness.

Effect of Preantral Follicle Isolation Technique on In Vitro Follicular Development in Mice

  • Lim, Hyun-Joo;Kim, Dong-Hoon;Im, Gi-Sun;Park, Sung-Jai;Son, Jun-Kyu;Baek, Kwang-Soo;Kwon, Eung-Gi
    • Journal of Embryo Transfer
    • /
    • v.26 no.4
    • /
    • pp.223-227
    • /
    • 2011
  • The objective of this study was to compare of different isolation method of mouse preantral follicles, and to examine in vitro development of mouse preantral follicles isolated by different method. Preantral follicles were mechanically or enzymatically extracted from mouse ovaries. Mechanical isolation method used fine gauge needles and enzymatic method of isolating follicles used collagenase. The recovered preantral follicles were cultured for 10 days in alpha-minimal essential medium (${\alpha}$-MEM) + 5% FBS + Insulin-Transferrin-Selenium (ITS) + 100 mIU/ml FSH. The collected primary follicles by enzymatic treatment were higher than mechanical method. Others stage preantral follicle by mechanical isolation were higher than enzymatic method. After 10 days of culture, no statistical differences were shown in survival rates of preantral follicle among the 2 culture groups. The metaphase II rates of the oocytes were significantly higher (p<0.05) in mechanical method (17.8%) than in enzymatic method (5.1%). These results suggest that the isolation method of choice depends on the target stage preantral follicles and mechanical isolation is an optimal method of preantral folliclesin a culture of mouse preantral follicle.

A Study on the Salmonella spp. isolation method in the sewage specimens (하수중의 Salmonella spp. 분리방법에 관한 비교연구)

  • 김성수;염종화
    • Journal of environmental and Sanitary engineering
    • /
    • v.10 no.3
    • /
    • pp.35-44
    • /
    • 1995
  • This study was carried out in order to compare the methods for Salmonella spp. isolation from sewage and to settle the most appropriate conditions for that isolation. The direct enrichment method was more effective than the pre- enrichment method for Salmonella spp. isolation. The rate of detection was much higher when the specimens were enriched at $41.5^{\circ}C$ than when at $35^{\circ}C$. Usage of XLBG agar medium showed better results for Salmonella isolation than that of SS medium. It can be suggested that the most effective combination for Salmonella spp. isolation was the direct centrifugation(3,000 rpm 100m1)- direct enrichment($41.5^{\circ}$C)-usage of XLBG medium.

  • PDF

A Robust Fault Isolation Filter Design Based on Left Eigenstructure Assignment and its Application to Flight System (좌 고유구조지정법 기반 결실 고장 분리 필터 설계 및 비행체 시스템에의 응용)

  • Lee, Dae-Yung;Park, Jae-Weon
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.7 no.5
    • /
    • pp.384-392
    • /
    • 2001
  • In this paper, we propose a novel robust fault isolation filter design method using the left eigenstructure assignment scheme proposed by the authors. The proposed method guarantees that the ${\gamma}$ simultaneous faults can be isolated when the number of available outpur measurements is ${\gamma}$. Moreover, if there exist redundant output measurements, the eigenvaluses of te filter system can be assigned to the desired position or the filter can be designed robustly to, the system parameter variation. Liu & Si developed a filter design method which has the same purpose, fault isolation. However their method cannot use the redundant freedom of the output matrix C. The proposed filter can use the redundant freedom of the matrix C effectively. Beside this in this paper, an eigenstructure assignment methodology that satisfies the required fault isolation conditions is also proposed. The proposed fault isolation filter was applied for isolating the simultaneous faults to a VTOL aircraft in order to verify the fault isolation performance.

  • PDF

Evaluation method of isolation performance for MIMO isolation table using singular value of transmissibility matrix (전달율 행렬의 특이치를 이용한 다입력/다출력 제진대계의 절연성능 평가법)

  • Sun, Jong-Oh;Kim, Kwang-Joon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2012.04a
    • /
    • pp.324-329
    • /
    • 2012
  • Isolation tables are widely used for precision equipments and their isolation performances have been usually expressed and evaluated by transsmissibility. However, transmissibility is a concept for 1-degree of freedom(DOF) system. In practice, isolation tables are supproted by more than 4 springs. Each spring is subjected to vertical and horizontal ground vibrations, and also the table has more than 1-DOF. Therefore, isolation tables should be treated as multi-input/multi-output(MIMO) system of which isolation performance is expressed by transmissibility matrix. However, the matrix is too complicated to be an index for a system. In this paper, maximum singular value of transmissibility matrx is suggested as a simple performance index of a MIMO isolation system. Physical meaning of singular value is explained using a simple a 2-DOF isolation table. Furthermore, maximum singular values of passive, 3-DOF active and 6-DOF active isolation tables are obtained through experiments, and their meaning are explained and compared with each other.

  • PDF

Eigenstructure Assignment Method for Disturbance Suppression and Fault Isolation (외란 억제 및 고장 분리를 위한 고유구조 지정기법)

  • Seo, Young-Bong;Park, Jae-Weon
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.8 no.5
    • /
    • pp.357-362
    • /
    • 2002
  • The underlying principle of fault detection via unknown input observer is to make the state estimation error independent of disturbances(or unknown inputs). In this paper, we present a systematic method that can exactly assign the eigenstructure with disturbance suppression and fault isolation capability. A desired eigenstructure for both fault isolation and disturbance suppression is obtained by an optimization method. For the dual purposes, terms for fault isolation and far disturbance suppression are included in the employed objective function for the optimization. The proposed scheme is applied to a simple example to confirm the usefulness of the method.

Design theory and method of LNG isolation

  • Sun, Jiangang;Cui, Lifu;Li, Xiang;Wang, Zhen;Liu, Weibing;Lv, Yuan
    • Earthquakes and Structures
    • /
    • v.16 no.1
    • /
    • pp.1-9
    • /
    • 2019
  • To provide a simplified method for the base isolation design of LNG tanks, such as $16{\times}104m^3$ LNG tanks, we conducted a derivation and calculation example analysis of the dynamic response of the base isolation of LNG storage tanks, using dynamic response analysis theory with consideration of pile-soil interaction. The ADINA finite element software package was used to conduct the numerical simulation analysis, and compare it with the theoretical solution. The ground-shaking table experiment of LNG tank base isolation was carried out simultaneously. The results show that the pile-soil interaction is not obvious under the condition of base isolation. Comparing base isolation to no isolation, the seismic response clearly decreases, but there is less of an effect on the shaking wave height after adopting pile top isolation support. This indicates that the basic isolation measures cannot control the wave height. A comparison of the shaking table experiment with the finite element solution and the theoretical solution shows that the finite element solution and theoretical solution are feasible. The three experiments are mutually verified.

Simultaneous Optimization of Hybrid Mid-Story Isolation System and Building Structure (하이브리드 중간층 지진 격리 시스템과 빌딩 구조물의 동시 최적화)

  • Kim, Hyun-Su;Kang, Joo-Won
    • Journal of Korean Association for Spatial Structures
    • /
    • v.19 no.3
    • /
    • pp.51-59
    • /
    • 2019
  • A hybrid mid-story seismic isolation system with a smart damper has been proposed to mitigate seismic responses of tall buildings. Based on previous research, a hybrid mid-story seismic isolation system can provide effective control performance for reduction of seismic responses of tall buildings. Structural design of the hybrid mid-story seismic isolation system is generally performed after completion of structural design of a building structure. This design concept is called as an iterative design which is a general design process for structures and control devices. In the iterative design process, optimal design solution for the structure and control system is changed at each design stage. To solve this problem, the integrated optimal design method for the hybrid mid-story seismic isolation system and building structure was proposed in this study. An existing building with mid-story isolation system, i.e. Shiodome Sumitomo Building, was selected as an example structure for more realistic study. The hybrid mid-story isolation system in this study was composed of MR (magnetorheological) dampers. The stiffnessess and damping coefficients of the example building, maximum capacity of MR damper, and stiffness of isolation bearing were simultaneously optimized. Multi-objective genetic optimization method was employed for the simultaneous optimization of the example structure and the mid-story seismic isolation system. The optimization results show that the simultaneous optimization method can provide better control performance than the passive mid-story isolation system with reduction of structural materials.

Fault Detection And Isolation Of Two DC-DC Converters Parallel Operation By ZCT Method (ZCT방식을 이용한 두 개의 컨버터 병렬 운전 시고장 검출 및 분리)

  • 박상은
    • Proceedings of the KIPE Conference
    • /
    • 2000.07a
    • /
    • pp.172-176
    • /
    • 2000
  • The paper presents the fault detection and isolation of two DC-DC converters parallel operation by ZCT method. Two experimental prototype converters were designed and implemented for evaluation of fault tolerant system. The experimental results show that fault detection and isolation circuit works very well.

  • PDF