A hybrid mid-story seismic isolation system with a smart damper has been proposed to mitigate seismic responses of tall buildings. Based on previous research, a hybrid mid-story seismic isolation system can provide effective control performance for reduction of seismic responses of tall buildings. Structural design of the hybrid mid-story seismic isolation system is generally performed after completion of structural design of a building structure. This design concept is called as an iterative design which is a general design process for structures and control devices. In the iterative design process, optimal design solution for the structure and control system is changed at each design stage. To solve this problem, the integrated optimal design method for the hybrid mid-story seismic isolation system and building structure was proposed in this study. An existing building with mid-story isolation system, i.e. Shiodome Sumitomo Building, was selected as an example structure for more realistic study. The hybrid mid-story isolation system in this study was composed of MR (magnetorheological) dampers. The stiffnessess and damping coefficients of the example building, maximum capacity of MR damper, and stiffness of isolation bearing were simultaneously optimized. Multi-objective genetic optimization method was employed for the simultaneous optimization of the example structure and the mid-story seismic isolation system. The optimization results show that the simultaneous optimization method can provide better control performance than the passive mid-story isolation system with reduction of structural materials.
Keywords
Hybrid mid-story isolation system; Simultaneous optimization technique; Structural design; Seismic response reduction; Smart structural control system; Multi-objective optimization;
Citations & Related Records
Times Cited By KSCI : 4  (Citation Analysis)
연도 인용수 순위
1 Spencer, B. F. Jr., & Nagarajaiah, S., "State of the Art of Structural Control", Journal of Structural Engineering, Vol.129, No.7, pp.845-856, 2003   DOI
2 Martelli, A., Clemente, P., Stefano, A. D., Forni, M., & Salvatori, A., "Recent Development and Application of Seismic Isolation and Energy Dissipation and Conditions for Their Correct Use", Perspectives on European Earthquake Engineering and Seismology, pp.449-488, 2014
3 Hur, M. W., Ann, T. S., Son, J. W., & Kim, C. S., "Construction of Isolation Device for DONG-IL High-Vill New City", Review of Architecture and Building Science, Vol.54, No.5, pp.81-86, 2010
4 Tsuneki, Y., Torii, S., Murakami, K., & Sueoka, T. (2008). Middle-Story Isolated Structural System of High-Rise Building. Proceedings of the 14th World Conference on Earthquake Engineering, China
5 Choi, W. S., Jung, K. B., & Roh, J. W., "Nong-Hyup Integrated IT Center, Construction Project, Uiwang-si", Review of Architecture and Building Science, Vol.61 No.1, pp.63-67, 2016
6 Sueoka, T., Torii, S., & Tsuneki, Y. (2004). The Application of Response Control Design using Middle-Story Isolation System to High-Rise Builsing. Proceedings of the 13th World Conference on Earthquake Engineering, Canada
7 Kim, H. S., & Kang, J. W., "Vibration Control Performance Evaluation of Hybrid Mid-Story Isolation System for a Tall Building", Journal of Korean Association for Spatial Structures, Vol.18, No.3 pp.37-44, 2018   DOI
8 Park, K. S., & Koh, H. M., "Preference-based optimum design of an integrated structural control system using genetic algorithms", Advances in Engineering Software, Vol.35, No.2, pp.85-94, 2004   DOI
9 Ok, S. Y., Park, K. S., Song, J. H., & Koh, H. M., "Multi-Objective Integrated Optimal Design of Hybrid Structure-Damper System Satisfying Target Reliability", Journal of the Earthquake Engineering Society of Korea, Vol.12, No.2, pp.9-22, 2008   DOI
10 Kim, H. S., & Kang, J. W., "Study of Integrated Optimal Design of Smart Top-Story Isolation and Building Structures in Regions of Low-to-Moderate Seismicity", Journal of the Korea Institute for Structural Maintenance and Inspection, Vol.17, No.5, pp.13-21, 2013   DOI
11 Park, K. S., Koh, H. M., & Hahm, D., "Integrated optimum design of viscoelastically damped structural systems", Engineering Structures, Vol.26, No.5, pp.581-591, 2004   DOI
12 Mele, E., & Faiella, D., "Inter-Story Isolation Systems (IIS) for Tall Buildings: Design Considerations", Structural Engineering, CTBUH Journal, Issue 2, pp.34-41, 2018
13 Sues, R. H., Mau, S. T., & Wen, Y. -K., "Systems Identifcation of Degrading Hysteretic Restoring Forces", Journal of Engineering Mechanics, Vol.114, No.5, pp.833-846, 1988   DOI
14 Ok, S. Y., Kim, D. S., Koh, H. M., & Park, K. S., "GA-Based Optimal Design for Vibration Control of Adjacent Structures with Linear Viscous Damping System", Journal of Earthquake Engineering Society of Korea, Vol.11, No.1, pp.11-19, 2007
15 Deb, K., Pratap, A., Agarwal, S., & Meyarivan, T., "A Fast and Elitist Multiobjective Genetic Algorithm: NSGA-II", IEEE Transactions on Evolutionary Computation, Vol.6, No.2, pp.182-197, 2002   DOI