• Title/Summary/Keyword: Isolation efficiency

Search Result 308, Processing Time 0.026 seconds

High Efficiency High-Step-up Single-ended DC-DC Converter with Small Output Voltage Ripple

  • Kim, Do-Hyun;Kim, Hyun-Woo;Park, Joung-Hu;Jeon, Hee-Jong
    • Journal of Power Electronics
    • /
    • v.15 no.6
    • /
    • pp.1468-1479
    • /
    • 2015
  • Renewable energy resources such as wind and photovoltaic power generation systems demand a high step-up DC-DC converters to convert the low voltage to commercial grid voltage. However, the high step-up converter using a transformer has limitations of high voltage stresses of switches and diodes when the transformer winding ratio increases. Accordingly, conventional studies have been applied to series-connect multioutput converters such as forward-flyback and switched-capacitor flyback to reduce the transformer winding ratio. This paper proposes new single-ended converter topologies of an isolation type and a non-isolation type to improve power efficiency, cost-effectiveness, and output ripple. The first proposal is an isolation-type charge-pump switched-capacitor flyback converter that includes an extreme-ratio isolation switched-capacitor cell with a chargepump circuit. It reduces the transformer winding number and the output ripple, and further improves power efficiency without any cost increase. The next proposal is a non-isolation charge-pump switched-capacitor-flyback tapped-inductor boost converter, which adds a charge-pump-connected flyback circuit to the conventional switched-capacitor boost converter to improve the power efficiency and to reduce the efficiency degradation from the input variation. In this paper, the operation principle of the proposed scheme is presented with the experimental results of the 100 W DC-DC converter for verification.

Edge Isolation Effects on Silicon Solar Cells using a Laser Scribing Process (레이저 스크라이빙 공정을 이용한 실리콘 태양전지의 측면분리 효과)

  • Joo, Jae-Hong;Jung, Soon-Won;Kim, Kwang-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.5
    • /
    • pp.851-856
    • /
    • 2017
  • Research on the edge isolation process of typical polycrystalline silicon solar cells was carried out using laser scribing equipment. The voltage-current characteristics of the solar cell before and after laser scribing were analyzed using a solar simulator. Current density and efficiency increased as the fill factor of the solar cell remained constant after the laser scribing process. The efficiency of the solar cell can be increased in a short time by the edge isolation process performed via a laser scribing process. The polycrystalline silicon solar cell was made into a series electrode, and the efficiency of the solar cell increased because the width of the solar cell was narrowed and the active region was widened by the laser scribing process.

Performance Analysis of High Efficiency DC-DC Chopper added in Electric Isolation (고효율 절연형 DC-DC 초퍼의 특성해석)

  • Kwak, Dong-Kurl;Lee, Bong-Seob;Kim, Choon-Sam;Jung, Do-Young;Kim, Soo-Kwang
    • Proceedings of the KIPE Conference
    • /
    • 2007.11a
    • /
    • pp.115-117
    • /
    • 2007
  • This paper is analyzed for DC-DC chopper performance of high efficiency added in electric isolation. The general converters of high efficiency are made that the power loss of the used switching devices is minimized. To achieve high efficiency system, the proposed chopper is constructed by using a partial resonant circuit. The control switches using in the chopper are operated with soft switching for a partial resonant method. The control switches are operated without increasing their voltage and current stresses by the soft switching technology. The result is that the switching loss is very low and the efficiency of chopper is high. And the proposed chopper is added in a electric isolation. When the power conversion system is required to electric isolation, the proposed chopper is adopted with system development of high efficiency. The soft switching operation and the system efficiency of the proposed chopper is verified by digital simulation and experimental results.

  • PDF

A Vibration Isolation System Design for a Vibration-sensitive Equipment (정밀 가공 장비를 위한 방진 시스템 설계 사례)

  • Hong, Seok-In;Kim, Ho-Sang;Lee, Dae-Hee;Lee, Kyung-Don;Jang, Han-Kee
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.16 no.3 s.108
    • /
    • pp.307-312
    • /
    • 2006
  • In this study a vibration isolation system with the cradle-type support was designed so as to reduce the transient vibration due to positioning motion of the moving mass on worktable as well as to achieve the desired isolation efficiency on the floor vibration. The design procedure was performed in the two steps. The first step to select appropriate isolators to meet the isolation efficiency, and the second step is to reduce the transient vibration of the worktable by adopting the cradle-type support. After the application of the selected isolators with the cradle-type support to the system it was shown that the required vibration criterion(VC-D) was easily satisfied and that the undesirable transient vibration was reduced remarkably.

Foundation size effect on the efficiency of seismic base isolation using a layer of stone pebbles

  • Banovic, Ivan;Radnic, Jure;Grgic, Nikola
    • Earthquakes and Structures
    • /
    • v.19 no.2
    • /
    • pp.103-117
    • /
    • 2020
  • The effect of the foundation size on the efficiency of seismic base isolation using a layer of stone pebbles is experimentally investigated. Four scaled models of buildings with different stiffnesses (from very stiff to soft) were tested, each with the so-called small and large foundation, and exposed to four different accelerograms (different predominant periods and durations). Tests were conducted so that the strains in the model remained elastic and afterwards the models were tested until collapse. Each model was tested for the case of the foundation being supported on a rigid base and on an aseismic layer. Compared to the smaller foundation, the larger foundation results in a reduced rocking effect, higher earthquake forces and lower bearing capacity of the tested models, with respectable efficiency (reduced strain/stress, displacement and increase of the ultimate bearing capacity of the model) for the considered seismic base isolation compared to the foundation on a rigid base.

Experimental Study on Railway Vibration Isolation of a Large Structure using Isolation Materials (방진재를 이용한 대형구조물의 철도 진동에 관한 실험적 연구)

  • Ryu, Bong-Jo;Lee, Hong-Gi;Koo, Kyung-Wan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.6
    • /
    • pp.1286-1292
    • /
    • 2011
  • The paper deals with the vibration isolation of a large structure using an experimental technology. In the case of vibration isolation for the vicinity of a subway or a railroad station, most of vibration isolation techniques using isolation materials with high isolation efficiency only, have been applied. Therefore, the quantitative evaluation and design technologies are required for a vibration isolation of large structures. In this study, firstly, vibration characteristics due to train or subway are analyzed. Secondly, the performance of existing vibration isolation materials such as precision isolation material, elastomer is estimated through the experiments. Thirdly, the performance of a tire isolation material and its frame is tested and evaluated. Finally, it is shown that tire isolation materials can be applied to the vibration isolation or vibration reduction of large structures.

Comparison of Seismic Retrofit Efficiencies of Base Isolation Systems for Existing Bridges

  • 조효남;엄원석
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.10a
    • /
    • pp.81-86
    • /
    • 2000
  • In recent modern protective systems have been introduced to reduce the vulnerability of bridges to seismic events. These protective systems include base isolation devices of different types, damping devices and active control devices. The objective of this study is to analytically evaluate the efficiency of a seismic retrofit scheme using base isolation systems, such as lead rubber bearings and sliding isolators. In this study, a triaxial model was used, which is capable of accurately developing the behavior of sliding isolators including the influence of the changing vertical force and velocity on the friction coefficients. Seismic response analyses of the bridge before and after retrofit were carried out by using a three-dimensional nonlinear seismic analysis program, IDARC-BRIDGE. To evaluate the efficiency of a retrofit scheme using triaxial isolators, a comparative study of performances of above two base isolation systems was conducted, and the numerical results show that the triaxial isolation solution can effectively reduce the sheat forces at the piers for the vertical ground motion.

  • PDF

A Study on Soft Switching Buck-Boost Converter added Electric Isolation (소프트 스위칭에 의한 절연형 벅-부스트 컨버터에 관한 연구)

  • Kwak, Dong-Kurl;Jung, Do-Young;Lee, Bong-Seob;Choi, Shin-Hyeong;Kim, Sang-Hoon
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.922-923
    • /
    • 2008
  • This paper is proposed to a novel DC-DC buck-boost converter added electric isolation by using a soft switching method. To be achieved of high efficiency system, the proposed converter is constructed by using a partial resonant circuit. The control switches using in the converter are operated with soft switching for a partial resonant method. The controlling switches are operated without increasing their voltage and current stresses by the soft switching technology. The result is that the switching loss is very low and the converter efficiency is high. And the proposed converter is added in a electric isolation. When the power conversion system is required to electric isolation, the proposed converter is adopted with system development of high efficiency. The soft switching operation and the system efficiency of the proposed converter is verified by digital simulation and experimental results.

  • PDF

A Development of Vibration Isolation Technology for a Large Structure using Experimental Research (실험적 기법을 이용한 대형구조물 교통진동 차진기술 개발)

  • Ryu, B.J.;Lee, H.G.;Son, S.W.;Lee, G.S.;Han, H.H.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.537-542
    • /
    • 2006
  • This paper deals with the vibration isolation techniques for a large structure using experimental research. In the case of vibration isolation for the vicinity of a subway or a railroad station, most of vibration isolation techniques using isolation materials with high isolation efficiency only, have been applied. Therefore, the quantitative evaluation and design technologies are required for a vibration isolation of large structures. In this study, firstly, vibration characteristics due to train or subway are analyzed. Secondly, the performance of existing vibration isolation materials such as precision isolation material, elastomer is estimated through the experiments. Thirdly the performance of tire isolation material and its frame is tested and evaluated.

  • PDF

A Study on Isolated DC-DC Converter of DCM (절연형 DCM DC-DC 컨버터에 관한 연구)

  • Kwak, D.K.;Lee, B.S.;Kim, C.S.;Shim, J.S.;Yu, J.H.;Son, J.H.
    • Proceedings of the KIPE Conference
    • /
    • 2010.07a
    • /
    • pp.15-16
    • /
    • 2010
  • This paper is study on a high efficiency DC-DC converter of discontinuous conduction mode (DCM) added electric isolation. The converters of high efficiency are generally made that the power losses of the used semiconductor switching devices is minimized. To achieve high efficiency system, the proposed converter is constructed by using a quasi resonant circuit. The control switches using in the converter are operated with soft switching by quasi resonant method. The control switches are operated without increasing their voltage and current stresses by the soft switching technology. The result is that the switching loss is very low and the efficiency of the system is high. The proposed converter is also added electric isolation which is used a pulse transformer. When the power conversion system is required electric isolation, the proposed converter is adopted with the converter system development of high efficiency. The soft switching operation and the system efficiency of the proposed converter are verified by digital simulation and experimental results.

  • PDF