Shaking Table Experimental Study on 3-Dimensional Floor Isolation in Main Control Room of Nuclear Power Plant (원전 주제어실 3차원 층 지진격리시스템의 진동대 실험 연구)

  • Lee, Kyung-Jin;Ham, Kyung-Won;Suh, Yong-Pyo;Yoon, Hyun-Do
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.12 no.1
    • /
    • pp.57-66
    • /
    • 2008
  • An experimental study was performed to evaluate seismic reduction performance and applicability of 3-dimensional floor isolation system to the main control room of nuclear power plant. A friction pendulum system(FPS) and air spring were designed and fabricated for 3-dimensional floor isolation system. Two kind of the partial experimental model of a main control room attached to the FPS and air spring were tested on the shaking table. The experimental model consisted of a control panel, a $2.5m{\times}2.5m$ access floor, four FPS and air springs. The artificial time histories based on the vertical and horizontal floor response spectrums(OBE, SSE) of the main control room were used as the earthquake input signals in the test. Compared to non-isolated system, the seismic response of experimental models using 3-dimensional floor isolation system were shown considerable seismic reduction performance.

Real-time hybrid simulation of smart base-isolated raised floor systems for high-tech industry

  • Chen, Pei-Ching;Hsu, Shiau-Ching;Zhong, You-Jin;Wang, Shiang-Jung
    • Smart Structures and Systems
    • /
    • v.23 no.1
    • /
    • pp.91-106
    • /
    • 2019
  • Adopting sloped rolling-type isolation devices underneath a raised floor system has been proved as one of the most effective approaches to mitigate seismic responses of the protected equipment installed above. However, pounding against surrounding walls or other obstructions may occur if such a base-isolated raised floor system is subjected to long-period excitation, leading to adverse effects or even more severe damage. In this study, real-time hybrid simulation (RTHS) is adopted to assess the control performance of a smart base-isolated raised floor system as it is an efficient and cost-effective experimental method. It is composed of multiple sloped rolling-type isolation devices, a rigid steel platen, four magnetorheological (MR) dampers, and protected high-tech equipment. One of the MR dampers is physically tested in the laboratory while the remainders are numerically simulated. In order to consider the effect of input excitation characteristics on the isolation performance, the smart base-isolated raised floor system is assumed to be located at the roof of a building and the ground level. Four control algorithms are designed for the MR dampers including passive-on, switching, modified switching, and fuzzy logic control. Six artificial spectrum-compatible input excitations and three slope angles of the isolation devices are considered in the RTHS. Experimental results demonstrate that the incorporation of semi-active control into a base-isolated raised floor system is effective and feasible in practice for high-tech industry.

Study on the Evaluation Method of Electrical Isolation Property for Hydrogen Fuel Cell Vehicle (수소연료전지자동차의 절연성능 평가방법에 관한 고찰)

  • Lee, Ki-Yeon;Kim, Dong-Ook;Kim, Hyang-Kon
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.22 no.6
    • /
    • pp.810-818
    • /
    • 2011
  • This paper analyzed the suitability about the isolation performance criteria which was based on human impedance and effect of current in IEC 60479-1 on the safety of human being was examined. The method of evaluation by megger and DC voltmeter was analyzed. The differences of isolation performance according to design of high-voltage system were analyzed. The factors which affect the insulation performance were analyzed for HFCV, EV, HEV, etc. through analysis of the isolation performance evaluation method. Finally, design for improved isolation performance was proposed.

Vibration Control of High-rise Building Structures using Top-story Isolation Systems (최상층면진시스템을 활용한 고층건물의 진동제어)

  • Kim, Tae-Ho;Kim, Hyun-Su
    • Journal of Korean Association for Spatial Structures
    • /
    • v.8 no.5
    • /
    • pp.75-82
    • /
    • 2008
  • In this study, the possibility of vibration control of high-rise building structures by applying top-story isolation has been investigated. To this end, El Centro NS (1940) earthquake load is applied to 20- and 50-story building structures for numerical analysis. Artificial wind loads are used to evaluate the serviceability of example structures against wind vibration. As the number of isolated stories of example buildings is changed, structural responses has been evaluated to investigate optimal isolated building mass. And the natural period of isolation systems for top-story isolation is varied to investigate the improvement of control performance compared with the fixed base structure. Based on the analytical results, the top-story isolation system can be used as a hued mass damper and effectively reduce the structural responses of high-rise buildings against wind and seismic loads.

  • PDF

Small Internal Antenna Using Multiband, Wideband, and High-Isolation MIMO Techniques

  • Kim, Sang-Hyeong;Jin, Zhe-Jun;Chae, Yoon-Byung;Yun, Tae-Yeoul
    • ETRI Journal
    • /
    • v.35 no.1
    • /
    • pp.51-57
    • /
    • 2013
  • In this paper, a small internal antenna for a mobile handset is presented using multiband, wideband, and high-isolation multiple-input multiple-output techniques. The proposed antenna consists of three planar inverted-F antennas (PIFAs) that operate in the global system for mobile communication (GSM900), the digital communication system (DCS), the personal communication system (PCS), the universal mobile telecommunication system (UMTS), and wireless local area network (WLAN) bands with a physical size of $40mm{\times}10mm{\times}10mm$. A resonator attached to the folded PIFA creates dual resonances, achieving a wide bandwidth of approximately 460 MHz, covering the DCS, PCS, and UMTS bands; a meander shorting line is used to improve impedance matching. Additionally, a modified neutralization link is embedded between diversity antennas to enhance isolation, which results in a 6-dB improvement in the isolation and less than 0.1 in the envelope correlation coefficient evaluated from the far-field radiation patterns. Simulation and measurements demonstrate very similar results for S-parameters and radiation patterns. Peak gains show 3.73 dBi, 3.77 dBi, 3.28 dBi, 2.15 dBi, and 5.86 dBi, and antenna efficiencies show 56.15%, 72.15%, 68.59%, 52.92%, and 82.93% for GSM900, DCS, PCS, UMTS, and WLAN bands, respectively.

Performance Analysis of High Efficiency DC-DC Chopper added in Electric Isolation (고효율 절연형 DC-DC 초퍼의 특성해석)

  • Kwak, Dong-Kurl;Lee, Bong-Seob;Kim, Choon-Sam;Jung, Do-Young;Kim, Soo-Kwang
    • Proceedings of the KIPE Conference
    • /
    • 2007.11a
    • /
    • pp.115-117
    • /
    • 2007
  • This paper is analyzed for DC-DC chopper performance of high efficiency added in electric isolation. The general converters of high efficiency are made that the power loss of the used switching devices is minimized. To achieve high efficiency system, the proposed chopper is constructed by using a partial resonant circuit. The control switches using in the chopper are operated with soft switching for a partial resonant method. The control switches are operated without increasing their voltage and current stresses by the soft switching technology. The result is that the switching loss is very low and the efficiency of chopper is high. And the proposed chopper is added in a electric isolation. When the power conversion system is required to electric isolation, the proposed chopper is adopted with system development of high efficiency. The soft switching operation and the system efficiency of the proposed chopper is verified by digital simulation and experimental results.

  • PDF

Vibrational Power Path Analysis with Rotational Terms Included and Its Application to Compressor System (회전 변형항을 고려한 진동파워 전달 경로별 기여도 분석 : 압축기계에의 응용)

  • Lee, Ho-Jung;Kim, Kwang-Joon
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.15 no.3 s.96
    • /
    • pp.280-289
    • /
    • 2005
  • A single degree of freedom system and transmissibility are key concepts in many problems of vibration isolation. In order to apply this approach, however, several assumptions must be satisfied, which are often not realistic. For examples, in practical systems, vibration transmissions at multi-point with multi-degree of freedom(translational and rotational DOF) take place and mobilities or impedances of receiver structures cannot be ignored any more especially over high frequency range. Therefore, a multi-dimensional treatment is required for accurate estimation of dynamic behavior of the system. In this paper, an approach using vibrational power flow is introduced to deal with analysis of multi-dimensional vibration isolation system in a more practical way and in aspects of vibration isolations and vibration path analysis. Procedures of this approach and some results of research for vibrational power path analysis with rotational terms included are presented. Difficulties in this method are also discussed.

Mechanism and Application of NMOS Leakage with Intra-Well Isolation Breakdown by Voltage Contrast Detection

  • Chen, Hunglin;Fan, Rongwei;Lou, Hsiaochi;Kuo, Mingsheng;Huang, Yiping
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.13 no.4
    • /
    • pp.402-409
    • /
    • 2013
  • An innovative application of voltage-contrast (VC) inspection allowed inline detection of NMOS leakage in dense SRAM cells is presented. Cell sizes of SRAM are continual to do the shrinkage with bit density promotion as semiconductor technology advanced, but the resulting challenges include not only development of smaller-scale devices, but also intra-devices isolation. The NMOS leakage caused by the underneath n+/P-well shorted to the adjacent PMOS/N-well was inspected by the proposed electron-beam (e-beam) scan in which VC images were compared during the in-line process step of post contact tungsten (W) CMP (Chemical Mechanical Planarization) instead of end-of-line electrical test, which has a long response time. A series of experiments based on the mechanism for improving the intra-well isolation was performed and verified by the inline VC inspection. An optimal process-integration condition involved to the tradeoff between the implant dosage and photo CD was carried out.

Seismic Design for Application of LNG Storage Tank Isolation System (LNG 저장탱크의 면진시스템 적용을 위한 내진설계)

  • Seo, Ki-Young;Park, Hyun-Jae;Kim, Nam-Sik;Kim, Jae-Min;Yang, Seong-Yeong
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.24 no.3
    • /
    • pp.227-235
    • /
    • 2014
  • The demand of natural gas is gradually increasing as a clean fuel in the world. Therefore, LNG storage tanks and related facilities of the importance of leading a community-based facility have emerged. The seismic design of LNG storage tank including seismic analysis have been developed steadily. But, the seismic analysis and design techniques for LNG storage tanks are lacking, in Korea. Consequently, it is necessary to develop an analysis model that LNG storage tanks in isolation system can describe the behavior. Further, LNG storage tank capable of ensuring safety and economy, it is necessary to develop design techniques. The studies have suggested seismic design procedures of LNG storage tanks with isolation system including triple-FPB and idealized complex hysteresis model of triple-FPB.

A Study on Soft Switching Buck-Boost Converter added Electric Isolation (소프트 스위칭에 의한 절연형 벅-부스트 컨버터에 관한 연구)

  • Kwak, Dong-Kurl;Jung, Do-Young;Lee, Bong-Seob;Choi, Shin-Hyeong;Kim, Sang-Hoon
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.922-923
    • /
    • 2008
  • This paper is proposed to a novel DC-DC buck-boost converter added electric isolation by using a soft switching method. To be achieved of high efficiency system, the proposed converter is constructed by using a partial resonant circuit. The control switches using in the converter are operated with soft switching for a partial resonant method. The controlling switches are operated without increasing their voltage and current stresses by the soft switching technology. The result is that the switching loss is very low and the converter efficiency is high. And the proposed converter is added in a electric isolation. When the power conversion system is required to electric isolation, the proposed converter is adopted with system development of high efficiency. The soft switching operation and the system efficiency of the proposed converter is verified by digital simulation and experimental results.

  • PDF