• Title/Summary/Keyword: Isolated grid

Search Result 73, Processing Time 0.024 seconds

Grid Independent Photovoltaic Fuel-Cell Hybrid System: Design and Control Strategy

  • Islam Saiful;Belmans Ronnie
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.5B no.4
    • /
    • pp.399-404
    • /
    • 2005
  • In this paper, a hybrid photovoltaic fuel-cell generation system employing an electrolyzer for hydrogen generation and battery for storage purpose is designed and simulated. The system is applicable for remote areas or isolated DC loads. Control strategy has been considered to achieve permanent power supply to the load via the photovoltaic/battery or the fuel cell based on the power available from the sun. MATLAB and SIMULINK have been used for the simulation work. A sensitivity analysis is conducted for various load level based on availability of solar radiation.

Design of Smart Mobility Charge Station with Non-isolated Grid-tied Single Phase System (비절연형 단상 계통 연계형 스마트 모빌리티 충전 시스템 설계)

  • Kim, Dae Won;Park, Sung-Min
    • Proceedings of the KIPE Conference
    • /
    • 2020.08a
    • /
    • pp.367-368
    • /
    • 2020
  • 미래 도시 교통 체계에 큰 변화를 줄 수 있는 매체로 스마트 모빌리티가 주목 받고 있다. 스마트 모빌리티 운용을 위해서는 효율적인 충전 시스템을 필요로 한다. 본 논문에서는 비절연형 단상 계통 연계형 태양광 발전 시스템에서의 스마트 모빌리티 충전 시스템 설계를 소개한다. 설계한 시스템의 회로 및 제어기 구성법은 Matlab/Simulink 시뮬레이션을 이용하여 해당 컨버터 및 인버터와 제어기 구성의 타당성을 보여준다.

  • PDF

Stationary Reference Frame Voltage Controller for Single Phase Grid Connected Inverter for Stand Alone Mode (계통 연계형 단상 인버터의 단독 운전 모드를 위한 정지좌표계 전압 제어기)

  • Hong, Chang-Pyo;Kim, Hag-Wone;Cho, Kwan-Yuhl;Lim, Byoung-Kuk
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.20 no.6
    • /
    • pp.517-525
    • /
    • 2015
  • A grid connected inverter must be operated as the main electricity source under an isolated condition caused by the grid problem. Conventionally, the dual loop controller is used for the grid inverter, and the controller is used for control under the stand-alone mode. Generally, the PI(Proportional - Integral) controller is highly efficient under a synchronous reference frame, and stable control can be available. However, in this synchronous frame-based control, high-quality DSP is required because many sinusoidal calculations are necessary. When the PI control is conducted under a stationary frame, the controller constructions are made simple so that they work even with a low-price micro controller. However, given the characteristics of the PI controller, it should be designed with the phase of reference voltage considered. Otherwise, the phase delay of the output voltage can occur. Although the current controller also has a higher bandwidth than the voltage controller, distortion of the voltage is difficult to avoid only by the rapid response of the PI controller, as a sudden load change can occur in the nonlinear load. In this study, a new control method that solves the voltage controller bandwidth problem and rapidly copes with it even in the nonlinear load situation is proposed. The validity of the proposed method is proved by simulation and experimental results.

A Study on the Potential Interference Analysis in the Isolated Grounding System by Field Tests (현장시험에 의한 독립접지 시스템의 전위간섭 해석에 관한 연구)

  • Kim, Kyung-Chul;Choi, Jong-Kee;Paik, Seung-Hyun;Park, Sang-Young;Kim, Jong-Uk
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.6
    • /
    • pp.145-151
    • /
    • 2004
  • The purpose of isolated grounding system is to protect own electrical facilities from the other grounding systems in order to avoid the potential interference between ground grid areas. But the physically close distances involved could lead to potential interference problems. The simplified equation for determining potential interferences based on the measured data under the case study grounding system is proposed in this paper. The results obtained with the equation to verify the accuracy have been compared with the results obtained from the CDEGS program.

6kW V2H Power Converter Using Isolated CLLC DAB Converter

  • Ko, Hyun-Seok;Hwangbo, Chan;Park, Seong-Mi;Park, Sung-Jun
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.25 no.4_1
    • /
    • pp.493-504
    • /
    • 2022
  • Recently, as interest in eco-friendliness grows, the supply of hybrid electric vehicles and pure electric vehicles (EVs) for improving fuel efficiency of automobiles is rapidly expanding. The average daily energy consumption of electric vehicles is less than 20 [%] of the total ESS capacity of the vehicle, and research on additional functions using the ESS of the vehicle is urgently needed to expand the supply of electric vehicles. V2H(Vehicle to Home), like V2G(Vehicle to Grid), includes the concept of cooperating with system stabilization using ESS of electric vehicles. In addition, it includes various operations that can realize home welfare, such as uninterrupted power supply in case of power outage at home, and power supply for home DC devices. Therefore, in order to expand the supply of eco-friendly electric vehicles, it is urgently required to develop a V2H system with various functions that can realize home welfare. In this paper, we propose a V2H system with a CLLC resonant converter and a non-isolated step-up converter that can solve different impedance and resonant frequencies depending on the power transfer direction. The proposed V2H system is 6 [kVA] applicable to 150-450 [V], the voltage range that can use the ESS voltage for electric vehicles, and is designed with a capacity that can handle instantaneous electricity use at home. In addition, in order to verify the feasibility, an experiment by Psim simulation and prototype production was performed.

Power Balancing Strategy in the Microgrid During Transient (마이크로그리드 과도상태 시 전력 수급 균형 전략)

  • Seo, Jae-Jin;Lee, Hak-Ju;Jung, Won-Wook;Won, Dong-Jun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.4
    • /
    • pp.707-714
    • /
    • 2010
  • When problems such as line fault, breakdown of a substation or a generator, etc. arise on the grid, the Microgrid is designed to be separated or isolated from the grid. Most existing DGs(Distributed Generators) in distribution system use rotating machine. However, new DGs such as micro gas turbine, fuel cell, photo voltaic, wind turbine, etc. will be interfaced with the Microgrid through an inverter. So the Microgrid may have very lower inertia than the conventional distribution system. By the way, the rate of change of frequency depends on the inertia of the power system. Moreover, frequency has a strong coupling with active power in power system. Because the frequency of the Microgrid may change rapidly and largely during transient, appropriate and fast control strategy is needed for stable operation of the Microgrid. Therefore, this paper presents a power balancing strategy in Microgrid during transient. Despite of strong power or frequency excursions, power balancing in the Microgrid can be maintained.

Development of 3kW Hybrid ESS with Function of Emergency Power Supply (비상전원 기능을 갖는 3kW급 하이브리드 ESS 개발)

  • Yang, Seok-Hyun;Kim, Min-Jae;Choi, Se-Wan;Cho, Jun-Seok
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.20 no.1
    • /
    • pp.11-18
    • /
    • 2015
  • This paper proposes a high-efficiency 3-kW hybrid ESS with emergency power supply. The proposed system enables efficient use of power from photovoltaic (PV) cells and energy storage system (ESS). The proposed system can operate as an uninterruptible power supply (UPS) when grid fault occurs, providing seamless transfer from grid-connected mode to stand-alone mode. The LLC converter for PV achieves ZVS turn-on of switches and ZCS turn-off of diodes, and the isolated bidirectional DC-DC converter for ESS achieves ZCS turn-off regardless of load condition, resulting in high efficiency. The efficiency and performance of the proposed hybrid ESS has been verified by a 3-kW prototype.

Analyzing the Impact of Supply Noise on Jitter in GBPS Serial Links on a Merged I/O-Core Power Delivery Network

  • Tan, Fern-Nee;Lee, Sheng Chyan
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.20 no.4
    • /
    • pp.69-74
    • /
    • 2013
  • In this paper, the impact of integrating large number of I/O (Input-Output) and Core power Delivery Network (PDN) on a 6 layers Flip-Chip Ball Grid Array (FCBGA) package is investigated. The impact of core induced supply noise on high-speed I/O interfaces, and high-speed I/O interface's supply noise coupling to adjacent high-speed I/O interfaces' jitter impact are studied. Concurrent stress validation software is used to induce SSO noise on each individual I/O interfaces; and at the same time; periodic noise is introduced from Core PDN into the I/O PDN domain. In order to have the maximum coupling impact, a prototype package is designed to merge the I/O and Core PDN as one while impact on jitter on each I/O interfaces are investigated. In order to understand the impact of the Core to I/O and I/O to I/O noise, the on-die noise measurements were measured and results were compared with the original PDN where each I/O and Core PDN are standalone and isolated are used as a benchmark.

Flow-induced Vibration of Transonic Turbine Cascades Considering Viscosity and Shock Wave Effects (점성 및 충격파효과를 고려한 천음속 터빈 케스케이드의 유체유발 진동해석)

  • Oh, Se-Won;Park, Oung;Kim, Dong-Hyun
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.16 no.9 s.114
    • /
    • pp.937-948
    • /
    • 2006
  • In this study, a fluid/structure coupled analysis system for simulating complex flow-induced vibration (FIV) phenomenon of cascades has been developed. The flow is modeled using Euler and Wavier-Stokes equations with different turbulent models. The fluid domains are modeled using the unstructured grid system with dynamic deformations due to the motion of structural boundary. The Spalart-Allmaras (S-A) and the SST ${\kappa}-{\omega}$ turbulent models are used to predict the transonic turbulent flows. A fully implicit time marching scheme based on the Newmark direct integration method is used in order to solve the coupled governing equations for viscous flow-induced vibration phenomena. For the purpose of validation for the developed FIV analysis system, comparison results for computational analyses of steady and unsteady aerodynamics and flutter analyses are presented in the transonic flow region. In addition, flow-induced vibration analyses for the isolated cascade and multi-blades cascade models have been conducted to show the physical fluid-structure interaction effects in the time domain.

Towards Cyber Security Risks Assessment in Electric Utility SCADA Systems

  • Woo, Pil Sung;Kim, Balho H.;Hur, Don
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.3
    • /
    • pp.888-894
    • /
    • 2015
  • This paper presents a unified model based assessment framework to quantify threats and vulnerabilities associated with control systems, especially in the SCADA (Supervisory Control and Data Acquisition) system. In the past, this system was primarily utilized as an isolated facility on a local basis, and then it started to be integrated with wide-area networks as the communication technology would make rapid progress. The introduction of smart grid, which is an innovative application of digital processing and communications to the power grid, might lead to more and more cyber threats originated from IT systems. However, an up-to-date power system often requires the real-time operations, which clearly implies that the cyber security would turn out to be a complicated but also crucial issue for the power system. In short, the purpose of this paper is to streamline a comprehensive approach to prioritizing cyber security risks which are expressed by the combination of threats, vulnerabilities, and values in the SCADA components.