• 제목/요약/키워드: Island power system

검색결과 248건 처리시간 0.031초

Optimization of Wind Power Dispatch to Minimize Energy Storage System Capacity

  • Nguyen, Cong-Long;Lee, Hong-Hee
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권3호
    • /
    • pp.1080-1088
    • /
    • 2014
  • By combining a wind turbine with an energy storage system (ESS), we are able to attenuate the intermittent wind power characteristic making the power derived from a wind farm dispatchable. This paper evaluates the influence of the phase delay of the low-pass filter in the conventional smoothing power control on the ESS capacity; longer phase delays require a larger ESS capacity. In order to eliminate the effect of the phase delay, we optimize the power dispatch using a zero-phase low-pass filter that results in a non-delayed response in the power dispatch. The proposed power dispatching method significantly minimizes the ESS capacity. In addition, the zero-phase low-pass filter, which is a symmetrical forward-reverse finite impulse response type, is designed simply with a small number of coefficients. Therefore, the proposed dispatching method is not only optimal, but can also be feasibly applied to real wind farms. The efficacy of the proposed dispatching method is verified by integrating a 3 MW wind turbine into the grid using wind data measured on Jeju Island.

Insulation Design and Reliability Evaluation of ±80kV HVDC XLPE Cables

  • Jung, Chae-Kyun;Park, Hung-Sok;Kang, Ji-Won
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권3호
    • /
    • pp.1002-1008
    • /
    • 2014
  • This paper describes insulation design and its reliability evaluation of ${\pm}80kV$ HVDC XLPE cable. Recently, the construction of HVDC transmission system, which is combined overhead line with underground cable, has been completed. This system is installed with existing 154 kV AC transmission line on the same tower. In this paper, the lightning transient analysis is firstly reviewed for selection of basic impulse insulation level and nominal insulation thickness. Then the electrical performance tests including load cycle test and superimposed impulse test based on CIGRE TB 496 are performed to evaluate the reliability of newly designed HVDC cable. There is no breakdown for ${\pm}80kV$ HVDC XLPE cable during electrical performance test. Finally, this system is installed in Jeju island based on successful electrical performance test (Type test). After installation tests are also successfully completed.

전압-주파수-구역을 고려한 에너지 최적화 네트워크-온-칩 설계 방법론 (Voltage-Frequency-Island Aware Energy Optimization Methodology for Network-on-Chip Design)

  • 김우중;권순태;신동군;한태희
    • 대한전자공학회논문지SD
    • /
    • 제46권8호
    • /
    • pp.22-30
    • /
    • 2009
  • 네트워크 온 칩 (Network-on-Chip, NoC) 기술은 기존 시스템-온-칩(System-on-Chip, SoC) 설계에서 IP 블록 수 증가와 이에 수반된 상호 연결 네트워크 복잡화 및 데이터 대역폭 제한 등의 문제점을 해결하기 위한 새로운 설계 패러다임이다. 더불어 동작 주파수 증가에 따른 급격한 전력 소모 클럭 신호의 분배와 동기화 문제 역시 중요한 이슈이며, 이에 대한 대안으로 광역적으로는 비동기, 국부적으로는 동기식 (Globally Asynchronous Locally Synchronous, GALS) 인 시스템 설계 방법론이 저전력 기술과 결합되어 에너지 소모를 줄이고 모듈적인 설계를 위해서 고려되어 왔다 GALS 방식의 설계 스타일은 정밀한 시스템 수준 전력 관리를 적용하기 위해 최근 소개되고 있는 전압 주파수 구역 (Voltage-Frequency-Island, VFI) 의 개념과 매우 잘 어울린다. 본 논문에서는 VFI를 적용한 NoC 시스템에서 최적의 전압선택을 통해 에너지 소모를 최소화하는 효율적인 알고리즘을 제시한다. 최적의 코어(또는 처리 소자) 전압과 VFI를 찾기 위해 통신량을 고려한 코어 그래프 분할, 통신-경쟁 시간을 고려한 타일 매핑, 전력 변화량을 고려한 코어의 동적 전압 조절 그리고 효율적인 VFI 병합 및 VFI 동적 전압 재 조절을 포함한다. 본 논문에서 제안한 설계 방법론은 기존 연구결과 대비 평균적으로 10.3%의 에너지 효율 향상이 있다는 것을 실험 결과를 통해 보여준다.

주파수 안정도 개선을 위한 디지털 조속기 제어기 개발 (Design of Digital Governor Controller for Frequency Stability Improvement)

  • 이상훈;최상규;이화춘;송성근
    • 조명전기설비학회논문지
    • /
    • 제26권9호
    • /
    • pp.64-72
    • /
    • 2012
  • The interest in wind power generation area such as developing and operating wind-diesel pilot complex in remote and island regions that have difficulty in having power plant and connecting to power system is growing rapidly in the world. We have installed and researched the hybrid system in Sekgok Pilot Complex to meet the new generation system. From the monitored data of the system, the performance of each diesel power plant is outstanding. However, step out problem was detected with respect to load sharing and synchronization with decentralized power supply. An advanced controller design having better response time and stability is needed to solve such problem. In this paper, we proposed the algorithm, through digital controller of Governor, which is applied to hybrid system. As a result, we obtained the stable frequency value in variable loading conditions. Also, we proved the advanced response time and stability through the simulation and experiment by applying additional current signal to the control algorithm.

Development of a User-Friendly Application for Voltage Sag Analysis

  • Park Chang-Hyun;Jang Gil-Soo;Kim Chul-Hwan;Kim Jae-Chul
    • Journal of Electrical Engineering and Technology
    • /
    • 제1권2호
    • /
    • pp.145-152
    • /
    • 2006
  • This paper presents a windows application for voltage sag analysis and effective data visualization. The developed Voltage Sag Analysis Tool (VSAT) was designed by using the Object-Oriented Programming (OOP) concept and C++ programming language. The VSAT provides basic functions for voltage sag analysis such as power flow analysis, short circuit analysis and stochastic analysis. In particular, the VSAT provides effective data visualization through computer graphics and animation. Analysis results are expressed realistically and intuitively on geographical display. The Graphic User Interface (GUI) of VSAT was designed specifically for voltage sag analysis. In this paper, the development and implementation of VSAT is presented. In order to demonstrate the capabilities of VSAT, it is used to analyze the Jeju Island power system in South Korea.

한반도 풍력 자원 지도의 공간 해상도가 풍력자원 예측 정확도에 미치는 영향에 관한 수치연구 (Numerical Study on the Impact of the Spatial Resolution of Wind Map in the Korean Peninsula on the Accuracy of Wind Energy Resources Estimation)

  • 이순환;이화운;김동혁;김민정;김현구
    • 한국환경과학회지
    • /
    • 제18권8호
    • /
    • pp.885-897
    • /
    • 2009
  • In order to make sure the impact of spatial resolution of wind energy map on the estimation of wind power density in the Korean Peninsula, the comparison studies on the characteristics of wind energy map with three different spatial resolutions were carried out. Numerical model used in the establishment of wind map is MM5 (5th generation Mesoscale Model) with RBAPS (Regional Data Assimilation and Prediction System) as initial and boundary data. Analyzed Period are four months (March, August, October, and December), which are representative of four seasons. Since high spatial resolution of wind map make the undulation of topography be clear, wind pattern in high resolution wind map is correspond well with topography pattern and maximum value of wind speed is also increase. Indication of island and mountains in wind energy map depends on the its spatial resolution, so wind patterns in Heuksan island and Jiri mountains are clearly different in high and low resolutions. And area averaged power density can be changed by estimation method of wind speed for unit area in the numerical model and by treatment of air density. Therefore the studiable resolution for the topography should be evaluated and set before the estimation of wind resources in the Korean Peninsula.

단독운전검출을 위한 능동적 주파수 변화 정궤환기법 (Active Frequency Drift Positive Feedback Method for Anti-islanding)

  • 소정훈;정영석;유권종;유병규;이기옥;최주엽
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 B
    • /
    • pp.1684-1686
    • /
    • 2005
  • As photovoltaic(PV) power generation systems become more common, it will be necessary to investigate islanding detection method for PV systems. Islanding of PV systems can cause a variety of problems and must be prevented. However, if the real and reactive power of load and PV system are closely matched, islanding detection by passive methods becomes difficult. Also, most active methods lose effectiveness when there are several PV systems feeding the same island. The active frequency drift positive feedback method(AFDPF) enables islanding detection by forcing the frequency of the voltage in the island to drift up or down. In this paper the research for the minimum value of chopping fraction gain applied digital phase-locked-loop(DPLL) to AFDPF considering output power quality and islanding prevention performance are performed by simulation and experiment in IEEE Std 929-2000 islanding test.

  • PDF

장주기 대용량 전력저장장치의 부하이전에 대한 실계통 적용 경제성 평가 연구 (An Economic Assessment of Large-scale Battery Energy Storage Systems in the Energy-Shift Application to Korea Power System)

  • 박종배;박용기;노재형;장병훈;윤용범
    • 전기학회논문지
    • /
    • 제64권3호
    • /
    • pp.384-392
    • /
    • 2015
  • This paper presents an economic assessment of large-scale Li-ion battery energy storage systems applied to Korean power system. There are many applications of the battery energy storage systems (BESSs) and they can provide various benefits to power systems. We consider BESSs to the energy time-shift application to Korean power system and evaluate the benefits from the application of BESS in the social perspective. The mixed integer programming (MIP) algorithm is used to resolve the optimal operation schedule of the BESS. The social benefits can include the savings of the fuel cost from generating units, deferral effects of the generation capacity, delay of transmission and distribution infra construction, and incremental CO2 emission cost impacts, etc. The economic evaluation of the BESS is separately applied into Korean power systems of the Main-land and Jeju island to reflect the differences of the load and generation patterns.

풍력발전기와 BESS를 결합한 전력계통의 공급신뢰도 기여함수 (Development of Reliability Contribution Function of Power System including Wind Turbine Generators combined with Battery Energy Storage System)

  • 오웅진;이연찬;최재석;윤용범;장병훈;차준민
    • 전기학회논문지
    • /
    • 제65권3호
    • /
    • pp.371-381
    • /
    • 2016
  • This paper presents a study on reliability assessment and new contribution function development of power system including Wind Turbine Generator(WTG) combined with Battery Energy Storage System(BESS). This paper develops and proposes new reliability contribution function of BESS installed at wind farms. The methodology of reliability assessment, using Monte Carlo Simulation(MCS) method to simulate sample state duration, is proposed in detail. Forced Outage Rate(FOR) considered probabilistic approach for conventional generators is modelled in this paper. The penetration of large wind power can make risk to power system adequacy, quality and stability. Although the fluctuation of wind power, BESS installed at wind farms may smooth the wind power fluctuation. Using small size system as similar as Jeju island power system, a case study of reliability evaluation and new proposed contribution function of power system containing WTG combined with BESS is demonstrated in this paper, which would contributes to BESS reliability contribution and assessment tools of actual power system in future.

전기자동차 부하 특성을 고려한 마이크로그리드의 최적 전원 구성에 관한 연구 (A Study on the Optimal Resource Configuration Considering Load Characteristics of Electric Vehicles in Micro Grid Environment)

  • 황성욱;채우규;이학주;윤상윤;김정훈
    • 전기학회논문지
    • /
    • 제64권2호
    • /
    • pp.228-231
    • /
    • 2015
  • In power system research fields, one of current key issues is the construction and commercialization of micro grid site which is called green island, carbon zero island, energy independent island, building micro grid, etc. and various affiliated technologies have been being vigorously developed to realize. In addition, various researches about electric vehicles (EVs) are in progress and it is expected to penetrate rapidly with the next a few years. Some new load models should be developed integrating with electric vehicle loads because the EVs' deployment could cause the change of load composition rate on power system planning and operations. EVs are also resources for micro grid as well as distributed generation and demand response so that various supply and demand side resources should be considered for micro grid researches. In this paper, the load composition rate of residential sectors is prospected considering the deployment of EVs and the resource configuration of micro grid is optimized based on net present cost. In the optimization, the load patten of case studies includes EV's charging characteristics and various cases are simulated comparing micro grid environment and normal condition. HOMER is used to compare various cases and economic effects.