• Title/Summary/Keyword: Irradiation test

Search Result 681, Processing Time 0.028 seconds

COMPARATIVE ANALYSIS OF STRUCTURAL CHANGES IN U-MO DISPERSED FUEL OF FULL-SIZE FUEL ELEMENTS AND MINI-RODS IRRADIATED IN THE MIR REACTOR

  • Izhutov, Aleksey.L.;Iakovlev, Valeriy.V.;Novoselov, Andrey.E.;Starkov, Vladimir.A.;Sheldyakov, Aleksey.A.;Shishin, Valeriy.Yu.;Kosenkov, Vladimir.M.;Vatulin, Aleksandr.V.;Dobrikova, Irina.V.;Suprun, Vladimir.B.;Kulakov, Gennadiy.V.
    • Nuclear Engineering and Technology
    • /
    • v.45 no.7
    • /
    • pp.859-870
    • /
    • 2013
  • The paper summarizes the irradiation test and post-irradiation examination (PIE) data for the U-Mo low-enriched fuel that was irradiated in the MIR reactor under the RERTR Program. The PIE data were analyzed for both full-size fuel rods and mini-rods with atomized powder dispersed in Al matrix as well as with additions of 2%, 5% and 13% of silicon in the matrix and ZrN protective coating on the fuel particles. The full-size fuel rods were irradiated up to an average burnup of ${\sim}60%^{235}U$; the mini-rods were irradiated to an average burnup of ${\sim}85%^{235}U$. The presented data show a significant increase of the void fraction in the U-Mo alloy as the U-235 burnup rises from ~ 40% up to ~ 85%. The effect of irradiation test conditions and U-235 burnup were analyzed with regard to the formation of an interaction layer between the matrix and fuel particles as well as generation of porosity in the U-Mo alloy. Shown here are changes in distribution of U fission products as the U-235 burnup increases from ~ 40% up to ~ 85%.

A Study on the Improvement of Adhesion according to the Process Variables of Ion Beam in the Cu/Polyimide Thin Film (이온빔의 공정변수에 따른 Cu/Polyimide 박막의 접착력향상에 관한 연구)

  • Shin Youn-Hak;Kim Myung-Han;Choi Jae-Ha
    • Korean Journal of Materials Research
    • /
    • v.15 no.7
    • /
    • pp.458-464
    • /
    • 2005
  • In microelectronics packaging, the reliability of the metal/polymer interfaces is an important issue because the adhesion strength between dissimilar materials is often inherently poor. The modification of polymer surfaces by ion beam irradiation and rf plasma is commonly used to enhance the adhesion strength of the interface. T-peel strengths were measured using a Cu/polyimide system under varying $N_2^+$ ion beam irradiation conditions for pretreatment. The measured T-peel strength showed reversed camel back shape regarding the fixed metal-layer thickness, which was quite different from the results of the 90° peel test. The elementary analysis suggests that the variation of the T-peel strength is a combined outcome of the plastic bending work of the metal and polymer strips. The results indicate that the peel strength increases with $N_2^+$ ion beam irradiation energy at the fixed metal-layer thickness.

Channel Gap Measurements of Irradiated Plate Fuel and Comparison with Post-Irradiation Plate Thickness

  • James A. Smith;Casey J. Jesse;William A. Hanson;Clark L. Scott;David L. Cottle
    • Nuclear Engineering and Technology
    • /
    • v.55 no.6
    • /
    • pp.2195-2205
    • /
    • 2023
  • One of the salient nuclear fuel performance parameters for new fuel types under development is changes in fuel thickness. To test the new commercially fabricated U-10Mo monolithic plate-type fuel, an irradiation experiment was designed that consisted of multiple mini-plate capsules distributed within the Advanced Test Reactor (ATR) core, the mini-plate 1 (MP-1) experiment. Each capsule contains eight mini-plates that were either fueled or "dummy" plates. Fuel thickness changes within a fuel assembly can be characterized by measuring the gaps between the plates ultrasonically. The channel gap probe (CGP) system is designed to measure the gaps between the plates and will provide information that supports qualification of U-10Mo monolithic fuel. This study will discuss the design and the results from the use of a custom-designed CGP system for characterizing the gaps between mini-plates within the MP-1 capsules. To ensure accurate and repeatable data, acceptance and calibration procedures have been developed. Unfortunately, there is no "gold" standard measurement to compare to CGP measurements. An effort was made to use plate thickness obtained from post-irradiation measurements to derive channel gap estimates for comparison with the CGP characterization.

Proton induced Effects on Commercial Single-mode Optical Fibers (상용 단일모드 광섬유의 양성자 영향)

  • Kim, Jong-yeol;Kim, Young-woong;Ryu, Guk-been;Hwang, Young-gwan;Lee, Min-Woong;Song, Keun-young
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2022.10a
    • /
    • pp.623-625
    • /
    • 2022
  • In this paper, the proton induced attenuation characteristics were evaluated for 5 types of commercial single-mode optical fibers using a proton accelerator. The proton beam used in the irradiation test has a high energy of 100 MeV class, and the test was performed by setting the uniformity of the beam irradiation area to 10% or less. According to the type of optical fiber (internal material, impurities), the radiation induced attenuation by the proton irradiation showed a noticeable difference.

  • PDF

Experimental study on the effect of low energy laser irradiation in Langerhans cell of Lanaged rat oral mucosa (저출력 레이저 조사 백서구강점막 창상부 Langerhans 세포에 미치는 영향에 관한 실험적 연구)

  • Cho, Jae-O;Hanks, Carl T.
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.15 no.3
    • /
    • pp.217-228
    • /
    • 1993
  • The purpose or this study was to observe the histological alteration of Langerhans cells on wound healing process in applying low energy laser irradiation. For this study, 50 Spraque-Dewly rats, weighing 150Gm or more were devided into control, experimental control group(0), 47.5Hz(1), 190Hz(3), 380Hz(5), 760Hz(7), lased group. All the experimental animals were made excision wound on buccal mucosa, 2mm depth, and lased with stoma laser (904nm, semconductor type ASGaAI, Sedalac France) 47.5Hz, 380Hz, 960Hz, 3minutes one time respectively except experimental control group. After the experiment, experimental animals were sacrificed after 24hours, 48hours, 72hours on each. Taken specimens were embedden in paraffin, sectioned 6-8u in thickness. And the langerhans cell were detected using ant S-100 protein antibody, and histochemically processed with Avidin Biotin complex method. All the Langerhan cells were calculated under light microspe in 400 multiplication field and standard deviation, probability test between each group were evaluated using statistical analysis system(S.A.S)program. Following results were obtained. 1. Langerhan cells were increased in experimental control group compared to that in control group(P<0.01). 2. 24hour after experiments, Langerhans cell were decreased compare to that in control group and control experimental group 5, 1, 3. Probability test shows significance between control experimental and 5, 1, 3 group on a =0.05 range. 3. 48our after experiment, Langerhans cells were decreased compare to that on experimental control group, and probability test shows significance between control experimental and 3, 7, 5 group an a=0.05 range. 4. 72hour after experiments, Langerhans cells were decreased compare to that on experimental control group and probability test on group comparison shows significance between control experimental and 1, 5 and 1 between 3, 7 between 3, and 5, between 7, respeilively on a=0.05 range. 5. Langerhans cells number in experimental group were decreased compare to that on experimental control group in applying laser irradiation.

  • PDF

Quality Improvement of Chicken Breast Meat in a Group-Meal Service by Gamma Irradiation (감마선조사에 의한 단체급식용 닭 가슴살의 품질 개선)

  • Kim Jang-Ho;Jeon Jin-Yong;Ryu Sang-Ryeol;Lee Ju-Woon;Kim Jae-Hun;Oh Sang-Hee;Seo Ji-Hyun;Byun Myung-Woo
    • Food Science and Preservation
    • /
    • v.12 no.1
    • /
    • pp.28-35
    • /
    • 2005
  • The storage temperature significantly affected the microbiological quality of the chicken breast In the non-inadiated samples at $30^{\circ}C$, aerobic plate count (APC) and Echerichia coli count of the samples considerably increased during 3 days of storage and were eliminated by an irradiation at dose of 10 kGy or more. The APC and E coli count of the samples stored at $5^{\circ}C$ were reduced to below the limit of detection (< 2 log CFU/g) through the whole storage period by an irradiation at 5 kGy or mote. There was no significant difference in the TBA values between the non-inadiated and inadiated samples, which were not significantly higher in the irradiated samples than the non-inadiated samples during 2 weeks of storage at $5^{\circ}C$. According to the same-different test and acceptance test the sensory quality of the irradiated chicken breast was not significantly different from that of the non-inadiated sample even at 10 kGy. It is found that gamma irradiation is an effective tool to improve the quality of chicken breast in a group-meal service. It was also found that there was no evidence that an irradiation induced mutagenicity in the chicken breast meat.

Hygienic Quality and Genotoxicological Safety of Gamma Irradiated Pork (감마선조사에 의한 돈육의 위생화 및 유전독성학적 안전성 평가)

  • 강일준;윤정한;강영희;이효구;변명우
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.28 no.5
    • /
    • pp.1092-1098
    • /
    • 1999
  • Gamma irradiation was applied to pork for improving its hygienic quality and evaluating its possible genotoxicity. The effective dose of irradiation was 3 kGy in pork for the sterilization of all contaminated microorganisms tested. After 8 weeks of storage at 5oC, no growth of microorganisms except for psychrophile and total aerobic bacteria was observed in the more than 3 kGy irradiated pork. The genotoxicity of high dose irradiated pork(30 kGy) was evaluated by Salmonella typhimurium reversion assay, chromosomal aberration test and in vivo micronucleus assay. The results were negative in the bacterial reversion assay with S. typhimurium TA98, TA100, TA1535, TA1537. In chromosomal aberration tests with CHL cells and in vivo mouse micronucleus assay, no significant difference in the incidences of chromosomal aberration and micronuclei was seen between nonirradiated and 30 kGy irradiated porks. These results indicate that 30 kGy irradiated pork did not show any genotoxic effects under these experimental conditions.

  • PDF

Optical Reactivity Modification of Titanium Oxide coatings on Ceramic filters by Nitrogen ion Implantation

  • Kim, Hyeong-Jin;Park, Jae-Won
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.08a
    • /
    • pp.90-90
    • /
    • 2010
  • We investigated the modification of optical response properties of titanium dioxide (TiO2) coatings on the ceramic water-purification filters by using ultraviolet-visible absorption spectroscopy and X-ray diffraction. The TiO2 coatings were prepared on ceramic substrate by e-beam evaporation method. These amorphous TiO2 were turned into anatase phase by heat treatment at $700^{\circ}C$ for 2 hours. The doping of N atoms into the TiO2 coatings was done by using 70KeV of N+ ion implantation with the dose of $1.0{\times}1017$ ions/cm2, followed by post-irradiation heat treatment at $550^{\circ}C$ for 2 hours. Methylene blue test of TiO2 coatings to solar irradiation showed that the post-evaporation heated TiO2 was photocatalytic and N-doped TiO2 reacted to the visible part of solar irradiation.

  • PDF

Using Microwave Irradiation to Prepare New Poly(amide-imide)s Containing Tetrahydropyrimidinone, Tetrahydro-2-thioxopyrimidine, and Trimellitic Rings in Their Main Chains: Synthesis and Characterization

  • Faghihi Khalil;Hagibeygi Mohsen
    • Macromolecular Research
    • /
    • v.13 no.1
    • /
    • pp.14-18
    • /
    • 2005
  • Under irradiation in a microwave oven, six novel poly(amide-imide)s containing tetrahydropyrimidinone, tetrahydro-2-thioxopyrimidine moieties and trimellitic rings in their main chains were synthesized through the polycondensation reaction of N,N'-(4,4'-diphenylether)bis(trimellitimide) diacid chloride with six different derivatives of tetrahydropyrimidinone and tetrahydro-2-thioxopyrimidine in the presence of a small amount of a polar organic medium, such as o-cresol. The polycondensation proceeded rapidly and completed within 7-9 min, producing a series of new poly(amide-imide)s in high yield that showed inherent viscosities in the range 0.33-0.52 dL/g. These poly(amide-imide)s were characterized by elemental analysis, viscosity measurement, thermal gravimetric analysis, solubility test, and FT-IR spectroscopy. All of the polymers were soluble at room temperature in polar solvents such as N,N-dimethylacetamide, N,N-dimethylformamide, dimethylsulfoxide, tetrahydrofuran, and N-methyl-2-pyrrolidone.