• Title/Summary/Keyword: Iridium-192 source

Search Result 13, Processing Time 0.027 seconds

Evaluation of Absorbed Dose for the Right Lung and Surrounding Organs of the Computational Human Phantom in Brachytherapy by Monte Carlo Simulation (근접방사선치료 시 몬테카를로 전산모사를 이용한 인체전산팬텀의 우측 폐와 주변 장기 선량평가)

  • Lee, Jun-Seong;Kim, Yang-Soo;Kim, Min-Gul;Kim, Jung-Soo;Lee, Sun-Young
    • Journal of radiological science and technology
    • /
    • v.43 no.6
    • /
    • pp.443-451
    • /
    • 2020
  • This study is to evaluate absorbed dose from right lung for brachytherapy and to estimate the effects of tissue heterogeneities on dose distribution for Iridium-192 source using Monte Carlo simulation. The study employed Geant4 code as Monte Carlo simulation to calculate the dosimetry parameters. The dose distribution of Iridium-192 source in solid water equivalent phantom including aluminium plate or steel plate inserted was calculated and compared with the measured dose by the ion chamber at various distances. And the simulation was used to evaluate the dose of gamma radiation absorbed in the lung organ and other organs around it. The dose distribution embedded in right lung was calculated due to the presence of heart, thymus, spine, stomach as well as left lung. The geometry of the human body was made up of adult male MIRD type of the computational human phantom. The dosimetric characteristics obtained for aluminium plate inserted were in good agreement with experimental results within 4%. The simulation results of steel plate inserted agreed well with a maximum difference 2.75%. Target organ considered to receive a dose of 100%, the surrounding organs were left the left lung of 3.93%, heart of 10.04%, thymus of 11.19%, spine of 12.64% and stomach of 0.95%. When the statistical error is performed for the computational human phantom, the statistical error of value is under 1%.

A Study on the Evaluation of Radiation Safety in Opened-Ceiling-Facilities for Radiography Testing (천장 개방형 RT 사용시설의 방사선 안전성 평가 연구)

  • Sung-Hoe, Heo;Won-Seok, Park;Seung-Uk, Heo;Byung-In, Min
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.6
    • /
    • pp.741-749
    • /
    • 2022
  • Radiography-Testing that verify the quality of welding structures without destruction are overwhelmingly used in industries, but many safety precautions are required as radiation is used. The workers for Radiography-Testing perform the inspection by moving the Iridium-192 radiation source embedded in the transport container of the gamma-ray irradiator within or outside the facility. The general facility is completely blocked about radiation from the outside with thick concrete, but if it is difficult for worker to handle object of inspection, facilities ceiling can be opened. A general facility may be constructed using a theoretical dose evaluation method because all exterior facilities are blocked, but if the ceiling is open, it is not appropriate to evaluate radiation safety with a simple theoretical calculation method due to the skyshine effect. Therefore, in this study, the radiation safety of the facility was evaluated in the actual field through an ion chamber survey-meter and an accumulated dose-meter called as OSLD, and the actual evaluation environment was modeled and evaluated using the Monte Carlo simulation code as FLUKA. According to the direction of the irradiation, the radiation dose at the facility boundary was difficult to meet the standards set by the regulatory authority, and radiation safety could be secured through additional methods. In addition, it was confirmed that the simulation results using the Iridium-192 source were valid evaluation with the actual measured results.

Determination of Exposure Dose Rate and Isotropic Distributions of Substitute High Dose Rate Ir-192 Source for Co-60 Brachytherapy Source (원격강내조사용 Co-60 선원의 대체용 Ir-192 선원의 조사선량결정 및 선량 등방성조사)

  • 최태진;원철호;김옥배;김시운;김금배;조운갑;한현수;박경배
    • Progress in Medical Physics
    • /
    • v.9 no.1
    • /
    • pp.55-64
    • /
    • 1998
  • In recent, the demand of development of the high dose rate brachytherapy source increased for substitute for Co-60 source by iridium source, since the supplying Co-60 source is very depressed and the high dose rate brachytherapy sources are entirely imported from the abroad. This study investigated the exposure rates and isotropic dose distributions for the Ir-192 source produced from $\^$191/Ir(n,r)$\^$192/Ir by nuclear reactor in Korea Atomic Energy Research Institute. The activity of source was obtained an 1.012 Ci (the initial activity without encapsulation was 2,87Ci) by measurement with encapsuled stainless steel. The exposure rate of provided Ir-192 source was determined on 6.36 ${\pm}$ 0.147 Rm$^2$/h-GBq (2.350 ${\pm}$ 0.054 Rcm$^2$/mCi-hr) within ${\pm}$ 2.2% discrepancy with IC-10 ion chamber (0.14 cc) which was mounted on the acrylic jig to 5, 10 and 20 cm from the center of source. The calculated doses with 22 most significant spectrum lines were corrected with intrinsic efficiency of the germanium detector were compared to measured exposure dose rates within ${\pm}$3.8 % discrepancy. The authors confirmed the high dose rate Ir-192 source could be replaced the long decayed Co-60 source via investigation of the isotropic dose distributions in lateral, source axis and diagonal direction of source center are very closed to within 3% uncertainties. Especially, this exposure rate constant and isotropic dose distribution will be fundamental to build the high dose rate source and develop the computed therapy planning system.

  • PDF

Dose modeling and its Application of Ir-192 for substitution of Ralstron Brachytherapy source (Ralstron 선원대체형 Iridium-192 선원의 선량모델링과 응용)

  • 김옥배;최태진;김진희;이호준;박정호;김성규;조운갑;한현수
    • Progress in Medical Physics
    • /
    • v.11 no.2
    • /
    • pp.131-139
    • /
    • 2000
  • We designed high dose rate Ir-192 source which was prepared for substitute the Co-60 source in Ralstron unit (Simatsu, Japan) which is supplied for cervical cancer treatment. The source dimension is 1.5 mm in a diameter and 1.5mm thickness of cylinder and encapsulated with 3 mm diameter of stainless steel(SUS316L) to substituted for the Co-60 source size. The Ir-192 source was prepared the dose model for tissue dose computation through the experimental determination of apparent activity and applied the empirical tissue correction factors extended to 20cm distance. The tissue dose model was applied the 4.69 R/cm-mCi-hr gamma constant and the ratio of energy absorption coefficient of water to that of air showed 1.112 include filteration of the self-absorptions. In this experiments, we prepared the dose computation software to clinical usefulness.

  • PDF

Microscopic Examination of Fracture Particles on the Surface of Ir-192 Sealed Source and Ultrasonic Cleaning (Ir-192 밀봉선원의 표면오염 방지)

  • Kuk, Il Hiun;Park, Chun Deuk;Koo, Ja Ho
    • Journal of Radiation Industry
    • /
    • v.9 no.2
    • /
    • pp.91-102
    • /
    • 2015
  • The iridium disc, generally used in industrial radiography, is examined to find the fracture morphology and fine particles remaining on the shear blank surface. Randomly selected 1,200 discs were observed under a scanning electron microscope tilted more than $45^{\circ}$. Fracture surfaces are classified into three groups: (1) surface fall-out, (2) fracture on the edge and (3) multi-step brittle fracture, which shows the mutual relationship between the fracture morphology and remaining particles. Fracture particles were removed by cleaning the discs in a ultrasonic bath with acetone and collected at the bottom. Removed number of the particles were counted for each different group of fracture surfaces. Followings are conclusions: (1) About 80.5% of discs (966/1,200), have sound plastic shear surfaces with particles remained. (2) About 2% discs accompany surface fall-out's having large particles tens of ${\mu}m$, which is stable not to be pulled out even after the considerably long time of ultrasonic cleaning. (3) About 5% discs contain the fractures on the edge and the particles are removed thoroughly within 30 minutes. (4) 234 discs out of 1,200 discs have multi-step fracture surfaces whose particles never removed in a short period of time but come out very slowly. Such a disc having multiple-step fracture is attributed to the promate cause to the 'leaker'. It is noted here that the discs having mutiple-step fractures should be treated separately with special care, and it is need to study how to treat them.

Development of $^{192}Ir$ Small-Focal Source for Non-Destructive Testing Application by Using Enriched Target Material (고농축 표적을 이용한 비파괴검사용 $^{192}Ir$ 미세초점선원 개발)

  • Son, K.J;Hong, S.B.;Jang, K.D.;Han, H.S.;Park, U.J.;Lee, J.S.;Kim, D.H.;Han, K.D.;Park, C.D.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.27 no.1
    • /
    • pp.31-37
    • /
    • 2007
  • A $^{192}Ir$ small-focal source has been developed by using the HANARO reactor and the radioisotope production facility at the Korea Atomic Energy Research Institute (KAERI). The small-focal source with the dimension of 0.5 mm in diameter and 0.5 mm in length was fabricated as an aluminum-encapsulated form by a specially designed pressing equipment. For the estimation of the radioactivity, neutron self-shielding and ${\gamma}-ray$ self-absorption effects on the measured activity was considered. From this estimation, it is realized that $^{192}Ir$ small-focal sources over 3 Ci activities can be produced from the HANARO. Field performance tests were performed by using a conventional source and the developed source to take images of a computer CPU and a piece of a carbon steel. The small-focal source showed better penetration sensitivity and geometrical sharpness than the conventional source does. It is concluded from the tests that the focal dimension of this source is small enough to maximize geometrical sharpness in the image taking for the close proximity shots, pipeline crawler applications and contact radiography.

Comparison of Non-Destructive Testing Images using $^{192}Ir$ and $^{75}Se$ with Computed Radiography System (Computed Radiography 시스템에 $^{192}Ir$$^{75}Se$ 동위원소를 적용하여 촬영한 비파괴검사 영상 비교)

  • Kang, Sang-Mook;Chol, Chang-Il;Lee, Seung-Kyu;Park, Sang-Ki;Kim, Yong-Kyun
    • Journal of Radiation Protection and Research
    • /
    • v.35 no.1
    • /
    • pp.26-33
    • /
    • 2010
  • A computed Radiography (CR) system by use of reusable Image Plate (IP) offers a convenient and reliable way to replace a conventional film-screen system for NDT (non-destructive testing) field. The quality of a radiography to detect a defect of welded objects depends on the procedure embracing several factors such as measurement conditions, image plate type/class, radiation energy, radiation type, and source to image plate distance. Also, the ability of images to detect a flaw reduces with increasing object thickness. In the study, the properties of gamma ray source were summarized for NDT field and inspection images of CR image system manufactured by FUJI were acquired using $^{75}Se$ and $^{192}Ir$ with welded objects. We analyzed the gray scale of hole defect image by using XCAP image processing program and calculated the image contrast and SNR in definition. Also the sesitivities of image quality indicator(IQI) were calculated for hot and cooling tube image of $^{75}Se$ and $^{192}Ir$.

EVALUATION OF BRACHYTHERAPY FACILITY SHIELDING STATUS IN KOREA OBTAINED FROM RADIATION SAFETY REPORTS

  • Keum, Mi Hyun;Park, Sung Ho;Ahn, Seung Do;Cho, Woon-Kap
    • Nuclear Engineering and Technology
    • /
    • v.45 no.5
    • /
    • pp.695-700
    • /
    • 2013
  • Thirty-eight radiation safety reports for brachytherapy equipment were evaluated to determine the current status of brachytherapy units in Korea and to assess how radiation oncology departments in Korea complete radiation safety reports. The following data was collected: radiation safety report publication year, brachytherapy unit manufacturer, type and activity of the source that was used, affiliation of the drafter, exposure rate constant, the treatment time used to calculate workload and the HVL values used to calculate shielding design goal values. A significant number of the reports (47.4%) included the personal information of the drafter. The treatment time estimates varied widely from 12 to 2,400 min/week. There was acceptable variation in the exposure rate constant values (ranging between 0.469 and 0.592 ($R{\cdot}m^2/Ci{\cdot}hr$), as well as in the HVLs of concrete, steel and lead for Iridium-192 sources that were used to calculate shielding design goal values. There is a need for standard guidelines for completing radiation safety reports that realistically reflect the current clinical situation of radiation oncology departments in Korea. The present study may be useful for formulating these guidelines.

Rectal Complication Following Radical Radiotherapy in Carcinoma of the Uterine Cervix (자궁경부암에서 근치적 방사선치료 후의 직장 합병증)

  • Kim Won-Dong;Park Woo-Yoon
    • Radiation Oncology Journal
    • /
    • v.24 no.1
    • /
    • pp.44-50
    • /
    • 2006
  • Puroose: This study evaluated the late rectal complications in cervix cancer patients following treatment with external beam radiotherapy (EBRT) and high dose rate intracavitary radiation (HDR ICR). The factors affecting the risk of developing late rectal complications and its incidence were analyzed and discussed. Materials and Methods: The records of 105 patients with cervix cancer who were treated with radical radiotherapy using HDR ICR between July, 1995 and December, 2001 were retrospectively reviewed. The median dose of EBRT was 50.4Gy $(41.4{\sim}56.4 Gy)$ with a daily fraction size of 1.8Gy. A total of $5{\sim}7$ (median: 6) fractions of HDR ICR were given twice weekly with a fraction size of $4{\sim}5 Gy$ (median: 4Gy) to A point using an Ir (Iridium)-192 source. The median dose of ICR was 24 Gy $(20{\sim}35 Gy)$. During HDR ICR, the rectal dose was measured in vivo by a semiconductor dosimeter. The median follow-up period was 32 months, ranging from 5 to 84 months. Results: Of the 105 patients, 12 patients (11%) developed late rectal complications: 7 patients with grade 1 or 2, 4 patients with grade 3 and 1 patient with grade 4. Rectal bleeding was the most frequent chief complaint. The complications usually began to occur $5{\sim}32$ (median: 12) months after the completion of radiotherapy. Multivariate analysis revealed that the measured cumulative rectal BED over 115 Gy3 (Deq over 69 Gy) and the depth (D) of a 5 Gy isodose volume more than 50 mm were the independent predictors for late rectal complications. Conclusion: With evaluating the cumulative rectal BED and the depth of a 5 Gy isodose volume as predictors, we can individualize treatment planning to reduce the probability of late rectal complications.

High-Dose-Rate Brachytherapy for Uterine Cervical Cancer : The Results of Different Fractionation Regimen (자궁경부암의 고선량률 근접치료 : 분할선량에 따른 결과 비교)

  • Yoon, Won-Sup;Kim, Tae-Hyun;Yang, Dae-Sik;Choi, Myung-Sun;Kim, Chul-Yong
    • Radiation Oncology Journal
    • /
    • v.20 no.3
    • /
    • pp.228-236
    • /
    • 2002
  • Purpose : Although high-dose-rate (HDR) brachytherapy regimens have been practiced with a variety of modalities and various degrees of success, few studies on the subject have been conducted. The purpose of this study was to compare the results of local control and late complication rate according to different HDR brachytherapy fractionation regimens in uterine cervical cancer patients. Methods and Materials : From November 1992 to March 1998, 224 patients with uterine conical cancer were treated with external beam irradiation and HDR brachytherapy. In external pelvic radiation therapy, the radiation dose was $45\~54\;Gy$ (median dose 54 Gy) with daily fraction size 1.8 Gy, five times per week. In HDR brachytherapy, 122 patients (Group A) were treated with three times weekly with 3 Gy to line-A (isodose line of 2 cm radius from source) and 102 patients (Group B) underwent the HDR brachytherapy twice weekly with 4 or 4.5 Gy to line-A after external beam irradiation. Iridium-192 was used as the source of HDR brachytherapy. Late complication was assessed from grade 1 to 5 using the RTOG morbidity grading system. Results : The local control rate (LCR) at 5 years was $80\%$ in group A and $84\%$ in group B (p=0.4523). In the patients treated with radiation therapy alone, LCR at 5 years was $60.9\%$ in group A and $76.9\%$ in group B (p=0.2557). In post-operative radiation therapy patients, LCR at 5 years was $92.6\%$ In group A and $91.6\%$ in group B (p=0.8867). The incidence of late complication was $18\%$ (22 patients) and $29.4\%$ (30 patients), of bladder complication was $9.8\%$ (12 patients) and $14.7\%$ (15 patients), and of rectal complication was $9.8\%$ (12 patients) and $21.6\%$ (22 patients), in group A and B, respectively. Lower fraction sized HDR brachytherapy was associated with decrease in late complication (p=0.0405) (rectal complication, p=0.0147; bladder complication, p=0.115). The same result was observed in postoperative radiation therapy patients (p=0.0860) and radiation only treated patients (0=0.0370). Conclusion : For radiation only treated patients, a greater number of itemized studies on the proper fraction size of HDR brachytherapy, with consideration for stages and prognostic factors, are required. In postoperative radiation therapy, the fraction size of HDR brachytherapy did not have much effect on local control, yet the incidence of late complication increased with the elevation in fraction size. We suggest that HDR brachytherapy three times weekly with 3 Gy could be an alternative method of therapy.