• 제목/요약/키워드: Iridium-192

검색결과 25건 처리시간 0.026초

방사선 이리디움(Ir-192) 근접치료의 임상적 응용 (The Clinical Application of Radioactive Iridium (Ir-192) Brachytherapy)

  • 유성열
    • 대한방사선치료학회지
    • /
    • 제3권1호
    • /
    • pp.11-18
    • /
    • 1989
  • Brachytherapy is known to be a good modality to achieve local control as a boost treatment following limited external irradiation, which may reduce the external beam related complication particularly in head and neck cancer. The authors developed iridium-192 ribbons recently to replace the radium needles in the field of brachytherapy. Total of 48 cases of head and neck and pelvic-perineal cancer patients had been treated with Ir-192 ribbons during last two years from October 1986 to September 1988, and the results were analyzed to assess the applicability of the fabricated sources. The conclusion is as follows; 1. Iridium implant resulted excellent tumor control effect in clinical application. 2. Iridium is superior than radium and cecium in brachytherapy because of easier to use and lesser exposure to the personnel. 3. Afterloading technique is useful to modify dose distribution, to expand treatment site and method, and to develop interstitial hyperthermia.

  • PDF

두경부암에서 방사성이리디움 삽입치료의 효과 (The Effect of Iridium-192 Implant in the Treatment of Head and Neck Cancer)

  • 류성렬;고경환;조철구
    • 대한두경부종양학회지
    • /
    • 제4권1호
    • /
    • pp.13-19
    • /
    • 1988
  • Brachytherapy is known to be a good modality to achieve local control as a boost treatment following limited external irradiation, which may reduce the external beam related acute radiation sickness, particularly in head and neck cancer. The authors developed iridium-192 ribbons recently to replace the radium needles. Total of 13 head and neck cancer patients had been treated with Ir-192 ribbons during last one year from October 1986 to September 1987, and the results were analysed to assess the applicability of the fabricated sources. The conclusion is as follows; 1) Iridium implant achieved 54% (7/13) of complete response and 69% (9/13) of overall response rate in head and neck cancer. 2) Iridium is superior to radium and cecium in brachytherapy because of easier to use and lesser exposure to the personnel. 3) Afterloading technique is useful to modify dose distribution, to expand treatment site and method, and to develop interstitial hyperthermia.

  • PDF

고분자량 아민에 의한 이리듐 제1염화주석 착물에 추출 및 분광광도법에 의한 이리듐의 정량법 (Spectrophotometric Determination of Iridium After Extraction of the Stannous-Chloro Complex by High Molecular Weight Amine)

  • 강형건;정구순
    • 대한화학회지
    • /
    • 제19권5호
    • /
    • pp.343-350
    • /
    • 1975
  • 염산수용액중에 존재하는 이리듐을 그 분자량 아민(Alamine 336)의 벤젠용액으로 추출한 바 20${\sim}$100${\mu}g$의 이리듐을 정량적으로 추출할 수 있음을 알았고 이때 이리듐 추출의 가능성에 관하여는 방사성 추적자(Ir-192)를 써서 확인하였다. 유기층에 추출된 화학종의 흡광도를 파장 322.5nm에서 측정한 결과 본 방법은 이리듐의 정량을 위한 미량분석법으로 사용할수 있음을 알았다. 이리듐이 아민층에 추출되는 메카니즘에 대한 설명을 시도하였다.

  • PDF

천장 개방형 RT 사용시설의 방사선 안전성 평가 연구 (A Study on the Evaluation of Radiation Safety in Opened-Ceiling-Facilities for Radiography Testing)

  • 허성회;박원석;허승욱;민병인
    • 한국방사선학회논문지
    • /
    • 제16권6호
    • /
    • pp.741-749
    • /
    • 2022
  • 산업체에서 용접구조물을 파괴 없이 품질을 검증하는 방사선투과검사는 압도적으로 많이 이용되지만, 방사선을 이용함에 따라 많은 안전사항이 요구된다. 방사선투과검사 작업종사자는 검사부재의 이동유무에 따라 감마선조사기인 운반용기에 내장된 Iridium-192 방사선원을 사용시설 내 혹은 사용시설 외의 장소에서 이동시켜 작업을 수행 한다. 일반적인 사용시설은 두꺼운 콘크리트로 외부와 방사선을 전면 차단한 시설이지만, 검사부재의 취급이 용이하지 않은 등의 사유로 천장이 개방된 사용시설이 있다. 일반적인 사용시설은 외부가 모두 차단되어 이론적인 선량 평가 방법을 통하여 건설하여도 무방하지만, 천장이 개방된 경우 스카이샤인효과로 인하여 단순 이론적인 계산 방법으로 방사선 안전성을 평가하는 것은 적합하지 않다. 따라서 본 연구에서는 실제 현장에서 해당 시설의 방사선 안전성을 이온챔버형 방사선측정기와 누적선량계형인 OSLD를 통하여 평가하고, 실제 평가 환경을 몬테카를로 시뮬레이션 코드인 플루카를 이용하여 모델링 및 평가를 하였다. 해당 시설에서 조사방향에 따라 시설 경계의 방사선량은 규제기관에서 정하는 기준을 만족하기 어려웠고, 추가의 방법을 통하여 방사선 안전성을 확보할 수 있었다. 또한, Iridium-192 선원을 이용한 시뮬레이션 결과가 실제 측정값과 유효한 결과임을 확인할 수 있었다.

근접방사선치료 시 몬테카를로 전산모사를 이용한 인체전산팬텀의 우측 폐와 주변 장기 선량평가 (Evaluation of Absorbed Dose for the Right Lung and Surrounding Organs of the Computational Human Phantom in Brachytherapy by Monte Carlo Simulation)

  • 이준성;김양수;김민걸;김정수;이선영
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제43권6호
    • /
    • pp.443-451
    • /
    • 2020
  • This study is to evaluate absorbed dose from right lung for brachytherapy and to estimate the effects of tissue heterogeneities on dose distribution for Iridium-192 source using Monte Carlo simulation. The study employed Geant4 code as Monte Carlo simulation to calculate the dosimetry parameters. The dose distribution of Iridium-192 source in solid water equivalent phantom including aluminium plate or steel plate inserted was calculated and compared with the measured dose by the ion chamber at various distances. And the simulation was used to evaluate the dose of gamma radiation absorbed in the lung organ and other organs around it. The dose distribution embedded in right lung was calculated due to the presence of heart, thymus, spine, stomach as well as left lung. The geometry of the human body was made up of adult male MIRD type of the computational human phantom. The dosimetric characteristics obtained for aluminium plate inserted were in good agreement with experimental results within 4%. The simulation results of steel plate inserted agreed well with a maximum difference 2.75%. Target organ considered to receive a dose of 100%, the surrounding organs were left the left lung of 3.93%, heart of 10.04%, thymus of 11.19%, spine of 12.64% and stomach of 0.95%. When the statistical error is performed for the computational human phantom, the statistical error of value is under 1%.

Ir-192 밀봉선원의 표면오염 방지 (Microscopic Examination of Fracture Particles on the Surface of Ir-192 Sealed Source and Ultrasonic Cleaning)

  • 국일현;박춘득;구자호
    • 방사선산업학회지
    • /
    • 제9권2호
    • /
    • pp.91-102
    • /
    • 2015
  • The iridium disc, generally used in industrial radiography, is examined to find the fracture morphology and fine particles remaining on the shear blank surface. Randomly selected 1,200 discs were observed under a scanning electron microscope tilted more than $45^{\circ}$. Fracture surfaces are classified into three groups: (1) surface fall-out, (2) fracture on the edge and (3) multi-step brittle fracture, which shows the mutual relationship between the fracture morphology and remaining particles. Fracture particles were removed by cleaning the discs in a ultrasonic bath with acetone and collected at the bottom. Removed number of the particles were counted for each different group of fracture surfaces. Followings are conclusions: (1) About 80.5% of discs (966/1,200), have sound plastic shear surfaces with particles remained. (2) About 2% discs accompany surface fall-out's having large particles tens of ${\mu}m$, which is stable not to be pulled out even after the considerably long time of ultrasonic cleaning. (3) About 5% discs contain the fractures on the edge and the particles are removed thoroughly within 30 minutes. (4) 234 discs out of 1,200 discs have multi-step fracture surfaces whose particles never removed in a short period of time but come out very slowly. Such a disc having multiple-step fracture is attributed to the promate cause to the 'leaker'. It is noted here that the discs having mutiple-step fractures should be treated separately with special care, and it is need to study how to treat them.

Computed Radiography 시스템에 $^{192}Ir$$^{75}Se$ 동위원소를 적용하여 촬영한 비파괴검사 영상 비교 (Comparison of Non-Destructive Testing Images using $^{192}Ir$ and $^{75}Se$ with Computed Radiography System)

  • 강상묵;최창일;이승규;박상기;김용균
    • Journal of Radiation Protection and Research
    • /
    • 제35권1호
    • /
    • pp.26-33
    • /
    • 2010
  • 비파괴검사 분야의 방사선 검사(RT) 방식은 image plate (IP)를 사용한 Computed Radiography(CR) 영상시스템의 도입에 따라 필름 방식의 아날로그 영상이 점차 디지털 영상으로 교체되고 있다. 비파괴검사에서 결함을 효과적으로 검출할 수 있는 영상의 품질은 촬영 조건, 영상획득매체, 사용 선원의 종류 및 촬영 거리, 검사체 두께등이 영향을 미친다. 본 논문에서는 비파괴 검사 분야에 적용할 수 있는 감마선원의 기본 특성을 조사하였고, FUJI사에서 개발한 CR 영상 시스템에 $^{75}Se$, $^{192}Ir$ 동위원소를 적용하여 영상을 획득하였다. 획득된 영상의 gray scale을 이미지 소프트웨어를 통해 추출한 후에 대조도 및 신호대잡음비를 계산하고 비교 분석하였다. 또한 투과도계를 이용한 비교 영상을 통하여 식별도를 분석하였다.

방사성동위원소 추적자를 이용한 표사이동 추적실험 (A Study on the Sediment Transport using Radioisotope Tracer)

  • 최병종;정성희;김종범;이종섭
    • 한국해안해양공학회지
    • /
    • 제16권3호
    • /
    • pp.162-170
    • /
    • 2004
  • 산업공정의 가동 중 효율 및 문제점 진단을 위한 방사성동위원소 추적자 이용기술과 기반장비의 연구결과를 바탕으로 연안에서 표사의 거동 추적실험을 수행하였다. 이를 위하여 원자로에서 중성자 조사를 통하여 방사화되는 소량의 iridium을 포함하는 표지모래를 사용하였다. 표지모래는 산화물 제조법으로 제조되었으며, 실험 현지의 자연사(2.65)와 유사한 비중(=2.6)을 갖도록 하였다. 방사화된 표지모래를 운반하고 실험 현장에서 해저에 투입할 수 있도록 전용 용기와 투입된 표지모래로부터 방출되는 방사선을 검출하기 위한 계측장비를 제작하였다. 또한, GPS로부터 수신되는 위치신호와 해저의 계측장비로부터 전송되는 방사선 계측신호를 동시에 수신할 수 있는 데이터 수집장치와 컴퓨터 응용프로그램을 제작하였다. 표지모래의 시간에 따른 공간적 분포변화를 측정하기 위하여 각 투입지점에 대하여 3회씩 추적실험을 실시하였다. 실험 결과데이터는 방사선 계측의 실제 위치를 계산하여 반영하고 방사성추적자의 자연감쇄 효과를 보정한 후 분석에 활용되었다. 방사성 표지모래를 이용한 시범실험으로부터 방사성추적자 기술의 연안환경의 보존과 개발을 위한 중요한 역할의 가능성을 확인하였다.

Ralstron 선원대체형 Iridium-192 선원의 선량모델링과 응용 (Dose modeling and its Application of Ir-192 for substitution of Ralstron Brachytherapy source)

  • 김옥배;최태진;김진희;이호준;박정호;김성규;조운갑;한현수
    • 한국의학물리학회지:의학물리
    • /
    • 제11권2호
    • /
    • pp.131-139
    • /
    • 2000
  • 국내도입 원격제어 근접조사장치인 Ralstron(Shimatsu, Japan) 의 코발트-60선원을 이리디움 192 선원으로 대체하고자 선원을 설계하고, 선원주위의 선량분포를 유도하였다. 이리디움 선원의 물리적크기는 직경1.5mm, 높이 1.5mm 로 370MBq(loci)를 목표로 설계하였으며, 외경은 3mm 이고, 크기는 13m이며, 캡슐의 재질은 SUS316L 이다. 선원 선원자체흡수와 스테인리스 스틸 캡슐에 의한 선량감쇠는 61.2%로 나타났으며, 단위방사능당 감마상수는 4.69R$cm^2$/mCi-hr였다. 조직선량은 공기중흡수선량 변환과 조직산란보정을 통해 구하였으며, 조직흡수선량변환계수는 이리디움의 에너지스펙트럼을 이용하여 공기에 대한 조직의 질량에너지흡수계수비 ($\mu$$_{en}$ )$^{tissue}$ air= 1.112 를 얻었다. 고안 선원에 대한 선량분포는 선원을 2,338개의 선원으로 분할하고, 각 분할선원에서 주위에 도달되는 선량을 이산적으로 누적 평가하여 임상에서 사용할 수 있도록 선량도표를 제공하였다.

  • PDF

원격강내조사용 Co-60 선원의 대체용 Ir-192 선원의 조사선량결정 및 선량 등방성조사 (Determination of Exposure Dose Rate and Isotropic Distributions of Substitute High Dose Rate Ir-192 Source for Co-60 Brachytherapy Source)

  • 최태진;원철호;김옥배;김시운;김금배;조운갑;한현수;박경배
    • 한국의학물리학회지:의학물리
    • /
    • 제9권1호
    • /
    • pp.55-64
    • /
    • 1998
  • 고선량률 원격 강내조사 선원은 전량 외국에서 수입되어 왔으며, 최근 Co-60 소선원의 공급부진으로 초기 도입시의 치료시간에 비해 4내지 5배의 시간을 조사하게 되어 대체용 선원의 개발이 크게 요구되고 있다. 이 연구는 국내 하나로 원자로의 중성자를 이용하여 $^{191}$ Ir(n,Υ)$^{192}$ Ir 핵반응을 일으켜 Ir-192 선원 2.87 Ci (밀봉 1.012 Ci)를 생산하고, 고선량률 원격 강내조사선원의 선량특성을 조사하였다. 제작선원에 대한 조사선량률은 아크릴 지지체의 중앙에 아크릴 아프리케이터를 고정하고 선원의 중심으로부터 각각 5, 10, 20 cm 거리에 전리함을 설치하여 일정시간 선원을 노출시켜 측정한 결과 6.36 $\pm$ 0.147 Rm$^2$/GBq-hr (2.350 $\pm$ 0.054 R$cm^2$/mCi-hr)을 결정하였으며, 측정오차는 1$\sigma$ 는 2.2% 였다. 계산선량은 조사선량률 상수 4.69 R$cm^2$/h-mCi 와 Ir-192 에너지 스펙트럼을 이용한 선원자체 및 철에 대한 질량흡수계수를 통해 구했으며, 실제 측정선량과 평균 3.8 % 오차범위에서 일치하였다. 선량 등방성은 선원의 측방향과 축 및 대각선방향으로 전리함을 이용하여 측정한 결과 3 % 이내 균등한 선량을 나타내었으며, 필름선량에서도 균등선량분포를 확인할 수 있었으며, Co-60 선원과 유사한 선량분포를 얻었을 수 있었다. 특히 본 연구의 선량특성조사는 강내조사선량선원 대체용의 선원개발과 선량계획 전산화의 근거가 될 것으로 믿는다.

  • PDF