• 제목/요약/키워드: Ir-inserted

검색결과 24건 처리시간 0.022초

An Isothermal Temperature Source with a Large Surface Area using the Metal-Etched Microwick-Inserted Vapor Chamber Heat Spreader

  • Go, Jeong-Sang;Kim, Kyung-Chun
    • Journal of Mechanical Science and Technology
    • /
    • 제18권4호
    • /
    • pp.681-688
    • /
    • 2004
  • For use of the thermal cycle of the biochemical fluid sample, the isothermal temperature source with a large surface area was designed, fabricated and its thermal characterization was experimentally evaluated. The comprehensive overview of the technology trend on the temperature control devices was detailed. The large surface area isothermal temperature source was realized by using the vapor chamber heat spreader. The cost-effectiveness and simple manufacturing process were achieved by using the metal-etched wick structure. The temperature distribution was quantitatively investigated by using IR temperature imaging system at equivalent temperatures to the PCR thermal cycle. The standard deviation was measured to be within 0.7$^{\circ}C$ for each temperature cycle. This concludes that the presented isothermal temperature source enables no temperature gradient inside bio-sample fluid. Furthermore it can be applied to the cooling of the electronic devices due to its slimness and low thermal spreading resistance.

PTMSP-NaA Zeolite 복합막에 의한 수소-질소 기체 분리에 관한 연구 (Separation of H2 and N2 Gases by PTMSP-NaA Zeolite Composite Membranes)

  • 김옥수;윤석일
    • 멤브레인
    • /
    • 제25권2호
    • /
    • pp.107-114
    • /
    • 2015
  • PTMSP에 0~50 wt% NaA Zeolite를 첨가하여 PTMSP-NaA Zeolite 복합막을 제조하고, PTMSP-NaA Zeolite 복합막의 특성을 FT-IR, $^1H$-NMR, GPC, DSC, TGA, SEM에 의해서 조사하였다. PTMSP-NaA Zeolite 복합막의 수소와 질소에 대한 투과도와 선택성을 NaA Zeolite 함량에 따라 조사하였다. TGA측정에 의하면 PTMSP에 NaA Zeolite가 첨가되었을 때 복합막의 감량이 완결되는 온도는 낮아졌고, 감량(wt%)도 작아졌다. SEM관찰에 의하면 NaA Zeolite는 PTMSP-NaA Zeolite 복합막 내에 $2{\sim}5{\mu}m$ 크기로 분산되어 있었다. PTMSP-NaA Zeolite 복합막에 대한 $N_2$$H_2$의 투과도는 NaA Zeolite 함량이 증가하면 증가하였다. 그리고 PTMSP-NaA Zeolite 복합막의 $N_2$에 대한 $H_2$의 선택성은 NaA Zeolite함량이 증가하면 감소하였다.

A Study on the Crevice Corrosion for Ferritic Stainless Steel by Micro Capillary Tube Method

  • Na Eun-Young;Ko Jae-Yong;Baik Shin-Young
    • 전기화학회지
    • /
    • 제7권4호
    • /
    • pp.179-182
    • /
    • 2004
  • The aim of this study is to investigate the initiation and propagation of crevice corrosion for ferritic stainless steel in artificial crevice based on micro capillary tube method. The 430 stainless steel in artificial crevice is potentiostatically polarized in different sodium chloride solutions. Potentiodynamic and potentiostatic polarization data were measured in situ. The potentials in the crevice were measured by depth profile using the 0.04 mm diameter micro capillary tube inserted in the crevice. The potentials in the crevice ranged from -220 mV to -360 mV vs SCE from opening to bottom of crevice, which are lower than the external surface potential, -200 mV vs SCE. Such a potential drop induced the change of the metal surface state from passive to active. The surface of metal is located in passive state in -200 mV but the inner surface keeps active state below -220 mV, Thus these results show that the It drop mechanism in the crevice was more objective for evaluation and the method was easier to reproduce. Therefore the potential drop is one of the reasons for crevice corrosion by measuring the potentials in narrow crevice with a new micro measuring system.

Fabrication and characterization of disposable golf tees using biodegradable polymer through 3D printing

  • Jihyuk Jung;Kwang Sun Huh;Jungho Jae;Kwang Se Lee
    • 청정기술
    • /
    • 제29권3호
    • /
    • pp.172-177
    • /
    • 2023
  • Many studies have been conducted on the indiscriminate use of plastic due to the environment problems it has caused all over the world. This problem can be mitigated by using eco-friendly/biodegradable plastics that can be decomposed by microorganisms or enzymes. This study focused on addressing the plastic golf tees that are thrown away at golf courses. In order to replace conventional golf tees (ABS) with a more eco-friendly alternative, this study explored a biodegradable plastic and 3D printing method for producing golf tees. Among the biodegradable plastics, PLA (polylactic acid) was found to be a good candidate as an eco-friendly material because it is biodegradable by microorganisms. Thus, golf tees were prepared by using PLA via 3D printing, and the physical and chemical properties of the tees were evaluated. The amorphous region of PLA was confirmed through XRD. Also, FT-IR showed the unique peak of PLA without impurities. It was confirmed through an optical microscope that the specific surface area and roughness had increased. This structure plays a role in firmly fixing the golf tee when it is inserted into the ground. In addition, it was possible to improve the compressive load compared to ABS golf tees while also decreasing the compressive stretching.

지방족 에스터-카보네이트 공중합체의 합성 (Synthesis of Aliphatic Ester-Carbonate Copolymer)

  • 김동국;김기섭;장영욱
    • 공업화학
    • /
    • 제7권5호
    • /
    • pp.970-976
    • /
    • 1996
  • 생분해성 지방족폴리에스터인 poly(butylene succinate) (PBS)의 기계적 물성을 변화시키기 위해서 에스터 주쇄 구조에 카보네이트 구조를 도입시킨 에스터-카보네이트 공중합체를 합성하였다. 이 공중합체는 일단계에서 succinic acid와 1,4-butanediol(BD)을 에스터 반응시켜 oligo(butylene succinate)를 합성하였고, 이 단계에서 oligohexamethylenecarbonate biol(OHMCG)을 첨가하고 고진공하에서 축중합하여 제조하였다. 촉매로는 titanium(IV) isopropoxide(TIP)를 사용하였다. 합성된 공중합체의 구조는 FT-IR과 $^1H$-NMR을 이용하여 확인하였으며, 열적, 기계적 물성은 각각 DSC와 UTM을 이용하여 조사하였다. 고분자량의 공중합체를 얻을 수 있는 적정 촉매양은 succinic acid에 대해서 1wt%였다. Diol 혼합물의 몰비(BD:OHMCG)가 249:1~149:1일 때, 높은 점도를 갖는 공중합체를 얻을 수 있었다 또한, OHMCG의 함량이 증가함에 따라 공중합체의 용융점은 계속 감소하였다. 혼합물의 몰비가 149:1인 경우의 공중합체의 물성은 PBS에 비해 초기탄성율은 약간 감소하였지만 파단신장율은 2배 정도 증가되었다.

  • PDF

위식도 역류 실시간 모니터링 마이크로 와이어 pH 전극 개발 (Development of Micro Wired pH Electrode for Real-Time Monitoring for Gastroesophageal Reflux)

  • 김응보;이규진;소상균;정연호;박정호;김남희
    • 대한의용생체공학회:의공학회지
    • /
    • 제38권6호
    • /
    • pp.277-284
    • /
    • 2017
  • This paper presents an implantable pH measurement electrode for wireless gastroesophageal reflux measurement. Usually, gastroesophageal reflux is diagnosed by a catheter-type wire connection between the esophagus and the diagnostic device which brings many side effects such as restriction of daily living, pain, and discomfort in the nasal cavity and pharynx of patients. In order to solve these issues, researchers have been studied a wireless measurement method and a micro-sized pH electrode for human body insertion is necessary. Commercial glass packaged pH meter is formed by a sensing and a reference electrodes in a KCl solution. However, if the glass meter is inserted into the human body, there are risks of leakage of the solution, breakage of the glass package, injury of the body elements. Therefore, the solution should be solidified on the micro-sized noble metal wire which has a characteristic of biocompatible. After solidified wire fabrication, the designed meter was tested for feasibility of measurement and the result was well agreed with pH values of commercial pH meter. Potentials in pH 1 to 12 solution was measured to obtain the sensitivity of the sensor with linearity. And we have designed a simulation of gastroesophageal reflux with symptom frequency, interval, and duration time in pH 2 solution. The proposed sensor has capable to get the same potential for 24 measurements in 3 days, and it has sensed same pH values of 2 for one hour with every 10 minutes. Furthermore, the sensor was survived for 48 hours with reasonable potentials in the acid solution.

PTMSP-NaY Zeolite 복합막에 의한 수소-질소 기체 분리에 관한 연구 (Separation of $H_2$ and $N_2$ Gases by PTMSP-NaY Zeolite Composite Membranes)

  • 김옥수;홍세령
    • 멤브레인
    • /
    • 제24권4호
    • /
    • pp.285-291
    • /
    • 2014
  • PTMSP[Poly(1-trimethylsilyl-1-propyne)]-NaY zeolite 복합막이 PTMSP에 0~50 wt% NaY zeolite를 첨가하여 제조되었다. 이 막들의 특성을 FT-IR, $^1H$-NMR, GPC, DSC, TGA, SEM에 의해서 조사하였다. 기체투과 실험은 $23{\sim}26^{\circ}C$, $2kgf/cm^2$에서 행하였고, 복합막에 대한 수소와 질소의 투과선택성은 NaY zeolite 함량에 따라 조사하였다. TGA 측정에 의하면 PTMSP에 NaY zeolite가 첨가되었을 때 PTMSP의 열적 안정성은 향상되었다. SEM 관찰에 의하면 NaY zeolite는 PTMSP-NaY zeolite 복합막 내에 약 $1.5{\mu}m$ 크기로 분산되어 있었다. PTMSP-NaY zeolite 복합막에 대한 $N_2$$H_2$의 투과도는 NaY zeolite 함량이 증가하면 증가하였다. 그리고 PTMSP-NaY zeolite 복합막의 $N_2$에 대한 $H_2$의 선택성은 NaY zeolite 함량이 증가하면 감소하였다.

선형열처리법으로 직접 접합된 Si 기판 및 산화된 Si 기판의 접합 특성 (Bonding Characteristics of Directly Bonded Si wafer and Oxidized Si wafer by using Linear Annealing Method)

  • 이진우;강춘식;송오성;류지호
    • 한국재료학회지
    • /
    • 제10권10호
    • /
    • pp.665-670
    • /
    • 2000
  • 실온에서 직접 접합된 실리콘 기판의 접합강도를 향상기키기 위하여 기존의 고온 로내 열처리법을 대체할 수 있는 선형 열처리법을 개발하였다. 한 개의 열원과 타원형 반사경으로 구성된 선형 열처리법은 접합면의 간격이 열처리 온도의 증가와 더불어 감소하는 특성과 온도 증가와 더불어 접합면에 생성된는 기체상의 밀도가 증가하는 현상을 응용하여 접합면의 기체상을 밀도차이를 이용하여 기판 외부로 방출시키는 방법으로 Si$\mid$$\mid$Si 기판쌍 및 Si$\mid$$\mid$$SiO_2/Si$ 기판쌍의 직접 접합에 적용하여 보았다. IR camera와 HRTEM으로 직접 관찰한 접합면은 실온에서 접합면에 침투한 외부 불순물에 의한 비접합 영역을 제외하고는 자제 생성된 기체상에 의한 비접합 영역은 나타나지 않았고 매우 깨끗한 접합계면을 나타내었다. 접합된 기판쌍을 Crack opening법과 인장시험법을 적용하여 접합 강도를 측정하였다. 접합 강도는 열처리 온도의 증가와 더불어 점차로 증가하였고 두 측정방법 모두 동일한 경향성을 나타내었다.

  • PDF

근접방사선치료용 CsPbBr3 선량계 제작 및 적용가능성 평가 (Development and Feasibility Evaluation of CsPbBr3 Dosimeter for Brachytherapy)

  • 양승우;박성광
    • 한국방사선학회논문지
    • /
    • 제16권4호
    • /
    • pp.405-410
    • /
    • 2022
  • 근접방사선치료에서는 종양조직을 사멸시키기 위하여 선원을 인체 내부에 삽입하기 때문에 선원의 위치 정확성을 정확히 파악하는 것이 중요하다. 본 연구에서는 기존 사용되는 검출기 재료로 사용되는 물질보다 저렴하고 제조 공정이 간단하여 기존 물질들을 대체할 수 있는 CsPbBr3를 사용하여 근접방사선치료용으로 사용가능한 선량계를 개발하고자 하였다. 그리고 192Ir 선원에서의 재현성, 선형성, 거리의존성 분석하여 선량계의 기초 성능을 평가하였다. 재현성 평가 결과, RSD는 1.36%로 기준치 1.5%를 만족하였다. 선형회귀분석에 따른 선형성 평가결과, 0.9993의 R2값으로 기준치 0.9990 이상의 R2이 제시되었다. 거리의존성 평가결과 거리가 멀어짐에 따라 지수적으로 일정하게 감소하는 신호값을 확인하였다. 재현성, 선형성, 거리의존성 평가결과에 기준 이상의 성능을 제시하여 제작된 CsPbBr3 선량계가 근접방사선치료용 선량계로 활용 가능한 것으로 보여주었다.

Spacer에 따른 백색 유기 전기 발광 소자의 전기적 특성에 관한 연구 (White organic light-emitting diodes with various spacers inserted between blue and red emissive layers)

  • 박정현;이석재;김구영;서지현;서지훈;윤승수;이승희;김영관
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 추계학술대회 논문집
    • /
    • pp.402-403
    • /
    • 2007
  • High-efficiency white organic light-emitting diodes (WOLEDs) were fabricated with two emissive layers and a spacer was sandwiched between two phosphorescent dyes which were, bis(3,5-Difluoro-2-(2-pyridyl)phenyl-(2-carboxypyridyl) iridium III (FIrpic) as the blue emission and bis(5-acetyl-2-phenylpyridinato-N,C2') acetylacetonate $((acppy)_2Ir(acac))$ as the red emission. This spacer effectively prevented a triple-triple energy transfer between the two phosphorescent emissive layers with blue and red emission that was showed a improved lifetime. The white device showed Commission Internationale De L'Eclairage $(CIE_{x,y})$ coordinates of (0.33, 0.42) at $22400\;cd/m^2$, a maximum luminance of $27300\;cd/m^2\;at\;0.388\;mA/cm^2$, and a maximum luminous efficiency of 26.9 cd/A.

  • PDF