• Title/Summary/Keyword: Iopamidol

Search Result 13, Processing Time 0.027 seconds

Physicochemical Analysis according to Temperature Changes of Iopamidol and Ioversol Formulation Contrast Agents (Iopamidol과 Ioversol 제제 조영제의 온도변화에 따른 물리화학적 분석)

  • Han, Beom-Hee
    • Journal of radiological science and technology
    • /
    • v.43 no.4
    • /
    • pp.273-280
    • /
    • 2020
  • In this study, the P contrast agent of Iopamidol, which is a nonionic iodide contrast agent most commonly used as a vascular contrast agent in medical institutions, and the O contrast agent of Ioversol, were studied. The physicochemical changes according to the temperature change were compared and analyzed using the Bruker Avance 500MHz Nuclear Magnetic Resonance Spectrometer owned by the Korea Basic Science Institute (KBSI). There was no physical or chemical change in the O contrast medium of Ioversol formulation in temperature change. However, in the P contrast agent of Iopamidol, a doublet peak began to appear in the 1.1 ppm region of the sample at 60℃, and the doublet peak was clearly observed in the sample at 80℃. As a result of this study, 1H-NMR analysis revealed that the P contrast agent of the Iopamidol formulation was dissociated from chemical bonds as it rose to a high temperature of 60℃ or higher, resulting in the formation of foreign substances. It was evaluated that the O contrast agent of Ioversol formulation had physico-chemical stability than the P contrast agent of Iopamidol formulation. As shown in this study, it is necessary to analyze the physical and chemical changes of contrast agents according to various environmental factors.

Comparative Analysis of Image Quality and Adverse Events between Iopamidol 250 and Ioversol 320 in Hepatic Angiography for Transcatheter Arterial Chemoembolization (경동맥 화학색전술을 위한 간동맥 혈관조영술에서 Ioversol 320과 비교한 Iopamidol 250의 영상 화질 비교 분석과 조영제 유해반응 평가)

  • Min Jae Gu;Jae Hyuck Yi;Young Hwan Kim;Hee Jung Lee;Ung Rae Kang;Seung Woo Ji
    • Journal of the Korean Society of Radiology
    • /
    • v.81 no.1
    • /
    • pp.166-175
    • /
    • 2020
  • Purpose This study aimed to compare the image quality and adverse events between Iopamidol 250 and Ioversol 320 usage during transcatheter arterial chemoembolization (TACE) for hepatocellular carcinoma (HCC). Materials and Methods Medical records and hepatic angiography from 113 patients who underwent TACE with Iopamidol 250 (44 patients) and Ioversol 320 (69 patients) were retrospectively reviewed. Vessel perception on hepatic angiography was graded into three categories by two radiologists for hepatic subsegmental arteries, the right gastroepiploic artery, right gastric artery, and pancreaticoduodenal artery. Imaging concordance was assessed by comparing the number of detected HCCs on hepatic angiography and CT. The adverse events before and after hepatic angiography were evaluated. Results The mean vessel perception scores were 2.92 and 2.94 for Iopamidol 250 and Ioversol 320, respectively. The imaging concordance was 31 (70.5%) and 46 (66.7%) patients for Iopamidol 250 and Ioversol 320, respectively. There were no statistical differences in vessel perception or imaging concordance (p > 0.05). One and six patients experienced nausea for Iopamidol 250 and Ioversol 320, respectively. There was no statistical difference in adverse events (p = 0.24). Conclusion Iopamidol 250 can be used in hepatic angiography for TACE without significant difference in image quality or occurrence of adverse events from Ioversol 320.

1H-NMR Analysis according to the Storage Period after the Use of Iopamidol and Ioversol Formulations Contrast Agents (Iopamidol과 Ioversol 제제 조영제의 사용 후 보관 기간에 따른 1H-NMR 분석)

  • Han, Beom-Hee
    • Journal of radiological science and technology
    • /
    • v.44 no.3
    • /
    • pp.239-245
    • /
    • 2021
  • Since the side effects of contrast agents occur in many ways, hospitals must clearly identify the contrast agents and know how to manage them. Storage of contrast media It is common practice to store contrast media in a warm room to reduce viscosity and improve patient comfort. However, it is important to recognize that long-term storage at high temperatures can shorten the shelf life of a product. Therefore, in this study, the presence or absence of chemical changes according to the storage period after using the contrast medium was analyzed. As the analysis equipment, a 500 MHz Nuclear Magnetic Resonance Spectrometer of Bruker Avance (Germany) possessed by Korea Basic Science Institute (KOREA BASIC SCIENCE INSTITUTE; KBSI) was used. For the X-ray iodide contrast medium, Pamiray contrast medium of Iopamidol and Optiray contrast medium of Ioversol, samples remaining after 7 days, 20 days, 30 days, and 1 year were collected, By acquiring the spectrum from the 1H-NMR spectrometer of the contrast medium stimulated by It was compared and analyzed with the standard sample. In conclusion, depending on the storage period of the contrast medium, no peaks of physical and chemical changes were observed in both the Pamiray contrast medium of Iopamidol and the Optiray contrast medium of Ioversol after 7 days, 20 days, 30 days, and 1 year after use.

A Comparison of Iopamidol with Iopromide and Iohexol Contrast Media in Hepatic CT Angiography in Beagle Dogs (비글견의 간 CT 혈관조영상에서의 Iopamidol과 Iopromide, Iohexol 조명제의 비교실험)

  • Jeong Yu-Cheol;Lim Chang-Yun;Kim Gyeong-Min;Lee Sung-Ok;Jung Joo-Hyun;Chang Jin-Hwa;Oh Sun-Kyoung;Song Kyoung-Jin;Yoon Jung-Hee;Choi Min-Cheol
    • Journal of Veterinary Clinics
    • /
    • v.23 no.2
    • /
    • pp.129-132
    • /
    • 2006
  • The purpose of this paper was to compare the clinical efficacy of iopamidol and iopromide, iohexol nonionic contrast media in terms of their image quality in Beagle dogs with hepatic CT angiography and their application in veterinary clinics. With 9 Beagle dogs, contrast media of iopamidol (pamiray-$300^(R)$) and iopromide (ultravist-$300^(R)$, iohexol (omnipaque-$300^(R)$) were induced intravenously (600 mg I/kg, BW) and CT angiography was done under general anesthesia. CT scan included scout, pre-contrast and cine examinations. During CT angiography, peak HU (Hounsfield unit) and peak time were examined on each site (ROI; region of interest) of the aorta, caudal vena cava, potral vein and liver parenchyma. Any side effects were also examined. After experiments, it was found that there were no significant changes of HU and maximal enhancing time of each ROIs of aorta, caudal vena cava, portal vein and liver parenchyma between these contrast media. And any side effects were not noted. So it is concluded that iopamidol has similiar contrast enhancement like as iopromide and iohexol in hepatic angiography and and it is thought to be useful for evaluation of the abdominal organs by CT scan in veterinary clinics.

Safety Evaluation of Iopamidol Contrast Medium Used for Radiological Examination of a Local Clinic in Korea (방사선 검사에 사용되는 조영제 Iopamidol의 안전성 평가)

  • Park, Chang-Mook;Lee, Bo-Reum;Song, Tea-Bum;Jang, Je-Kwan;Lee, Yu-Jeung;Lee, Myung-Koo;Lim, Sung-Cil
    • YAKHAK HOEJI
    • /
    • v.53 no.6
    • /
    • pp.328-333
    • /
    • 2009
  • Contrast media are substances that are used to enhance the contrast of structures or fluids within the body in medical imaging. Those are commonly used to enhance the visibility of blood vessels and the gastrointestinal tract. The aim of this study is to evaluate patients who got injected iopamidol, developed as one of contrast medium regarding changes in cardiovascular system and especially, adverse drug reactions. This study were performed on randomly selected a total of 51 patients (range of 15~85 years old) who got injected contrast medium, Iopamidol at a P hospital in Gyeonggi province from September 22nd, 2008 to January 24th, 2009. Data were collected by questionnaire though person to person. We analyzed the data by SPSS (Version 12. for windows). Methods of analysis were frequency and cross analysis. In results, 19.6% (n=10) were founded for adverse drug reactions of contrast medium. 25.0% (n=4) of 10 patients who had adverse drug reactions of contrast medium had took abdomen contrast test. 2 patients of those took contrast test for chest. Also, 3.9% (n=2) patients felt vomiting and nausea after injection of contrast medium. In conclusion, 19.6% patients experienced adverse drug reaction of contrast medium. Therefore, when taking radiation test, we should make efforts to minimize adverse drug reactions to achieve suitable and effective treatment.

Comparison of Radiograpic Contrast Techniques and Contrast Media on Dacryocygtorhinography in Dogs (개에서 누낭비강조영술시 조영방법 및 조영제의 비교)

  • Seo Kang-Moon;Cheong Jong-Tae;Kweon Oh-Kyeong;Sung Jai-Ki;Nam Tchi-Chou
    • Journal of Veterinary Clinics
    • /
    • v.11 no.1
    • /
    • pp.359-368
    • /
    • 1994
  • This study was undertaken to evaluate image quality and level of discomfort during examination with various contrast media(meglumine ioxitalamate: Telebrix $30^{\circledR}$ , diatrizoate sodium: Hypaque $50^{\circledR}$, sodium ioxaglate + meglumine ioxaglate: Hexabrix , iopamidol: Iopamiro $300^{\circledR}$ , iodized poppyseed oil: $Lipiodol^{\circledR}$ and barium sulfate: Baritop$^{\circledR}$and various radiographic contrast techniques(eye dropping: group 1, single injection to the superior punctum: group 2 and continuous injection to the superior punctum: group 3) on dacryocystorhinography in dogs. The results were as follows; 1. The Image quality of radiographic contrast technique of continuous Injection of contrast media(group 3) was better than the other techniques. 2. Average scores for dacryocystorhinography quality of sodium ioxaglate + meglumine ioxaglate, iopamidol, barium sulfate, iodized Poppyseed oil, meglumine ioxitalamate and diatrizoats sodium were 3.67${\pm}$0.47, 3.67${\pm}$0.47, 3.50${\pm}$0.50, 3.33${\pm}$0.75, 2.50${\pm}$0.50 and 2.50${\pm}$0.76, respectively in group 3. 3. Diatrizoate sodium produced more discomfort than the other media. It was considered that the best radiographic contrast technique of dacryocystorhinography was continuous injection of contrast media to the superior punctum and sodium ioxaglate + meglumine ioxaglate, iopamidol, iodized Poppyseed oil and barium sulfate were the excellent contrast media for dacryocystorhinography in dogs.

  • PDF

How Computed Tomography Contrast Media and Magnetic Resonance Imaging Contrast Media Affect the Changes of Uptake Counts of 201Tl

  • Lee, Jin-Hyeok;Lee, Hae-Kag;Cho, Jae-Hwan;Cheon, Miju
    • Journal of Magnetics
    • /
    • v.19 no.4
    • /
    • pp.372-377
    • /
    • 2014
  • The purpose of the study is to investigate how uptake counts of $^{201}Tl$ of radioisotopes in the human body could change, when taking computed tomography and magnetic resonance imaging right after injecting contrast media. $^{201}Tl$ radioisotope substances of iodine contrast medium, which is a computed tomography contrast medium, and paramagnetic contrast medium, which is an magnetic resonance imaging contrast medium, were used as study materials. First, $^{201}Tl$ was put into 4 cc of normal saline in test tube, and then a computed tomography contrast medium of Iopamidol$^{(R)}$ or Dotarem$^{(R)}$, was put into 2 cc of normal saline in test tube. An magnetic resonance imaging contrast medium of Primovist$^{(R)}$ or Gadovist$^{(R)}$ was also put into 2 cc of normal saline in test tube. Each contrast medium was distributed to make $^{201}Tl$ as 3 mCi, with a total of 4 cc. Gamma camera, low energy high resolution collimator, and pinhole collimator were used to obtain images. The uptake count of $^{201}Tl$ was measured with 1000 frames of images, and obtained after 10 times of repetition. This study revealed that the use of Gadovist$^{(R)}$, which is an magnetic resonance imaging contrast medium, showed the smallest number of uptake count, after measuring $^{201}Tl$ uptake count by low energy high resolution collimator. On the other hand, the use of Iopamidol$^{(R)}$, which is a computed tomography contrast medium, showed the biggest difference in uptake count, when measuring $^{99m}Tc$ uptake count by Pinhole collimator. When examining with gamma camera, using contrast medium and $^{201}Tl$, identifying the changes of uptake count is very important for improving the value of diagnosis.

Influence of Iodinated Contrast Media and Paramagnetic Contrast Media on Changes in Uptake Counts of 99mTc

  • Cho, Jae-Hwan;Lee, Jin-Hyeok;Park, Cheol-Soo;Lee, Sun-Yeob;Lee, Jin;Moon, Deog-Hwan;Lee, Hae-Kag
    • Journal of Magnetics
    • /
    • v.19 no.3
    • /
    • pp.248-254
    • /
    • 2014
  • The purpose of this study is to figure out how uptake counts of technetium ($^{99m}Tc$) among radioisotopes in the human body are affected if computed tomography (CT), magnetic resonance imaging (MRI) and isotope examination are performed consecutively. $^{99m}Tc$ isotope material, iodinated contrast media for CT and paramagnetic contrast media for magnetic resonance (MR) were used as experimental materials. First, $^{99m}Tc$ was added to 4 cc normal saline in a test tube. Then, 2 cc of CT contrast media such as $Iopamidol^{(R)}$ and $Dotarem^{(R)}$ were diluted with 2 cc normal saline, and 2cc of MRI contrast media such as $Primovist^{(R)}$ and $Gadovist^{(R)}$ were diluted with 2 cc normal saline. Each distributed contrast media was a total of 4 cc and included 10m Ci of $^{99m}Tc$. A gamma camera, a LEHR (Low energy high resolution) collimator and a pin-hole collimator were used for image acquisition. Image acquisition was repeated a total of 6 times and 120 frames were obtained and uptake counts of $^{99m}Tc$ were measured (from this procedure). In this study, as a result of measuring the uptake counts of $^{99m}Tc$ using the LEHR collimator, the uptake counts were less measured in all contrast media than normal saline as a reference. In particular, the lowest uptake counts were measured when $Gadovist^{(R)}$, contrast media for MRI, was used. However, the result of measuring the uptake counts of $^{99m}Tc$ using the pin-hole collimator showed higher uptake counts in all contrast media, except for $Iopamidol^{(R)}$, than normal saline as a reference. The highest uptake counts were measured particularly when $Primovist^{(R)}$, contrast media for MRI, was used. In performing the gamma camera examination using contrast media and $^{99m}Tc$, it is considered significant to check the changes in the uptake counts to improve various diagnosis values.

Influence of Iodinated Magnetic Resonance Contrast Media and Isotope 99mTc on Changes of Computed Tomography Number

  • Kim, Sang-Beom;Lee, Jin-Hyeok;Ahn, Jae-Ouk;Cho, Jae-Hwan
    • Journal of Magnetics
    • /
    • v.20 no.3
    • /
    • pp.302-307
    • /
    • 2015
  • The purpose of the study was to identify how isotope and magnetic resonance imaging (MRI) contrast media impact on noise to computed tomography (CT) examination. For the study, divide the phantoms to two groups: 1) saline, saline + different kinds of contrast agent without $^{99m}Tc$ administration; 2) $^{99m}Tc$ administration: saline, saline + different kinds of contrast agent with $^{99m}Tc$ administration. CT contrast agent was used for Iopamidol$^{(R)}$ and Dotarem. And MRI contrast agent was used for Primovist$^{(R)}$ and Gadovist$^{(R)}$. To obtain an image, we used CT scanner. With an obtained image, we set the $1cm^2$ region of interest in the middle of bottle to measure the noise and CT number. As a result, there was no difference in CT number before and after inserting $^{99m}Tc$ into all contrast media including Normal Saline. However, when it comes to Noise, there was a difference before and after inserting $^{99m}Tc$ into every contrast media except MRI contrast media such as Primovist$^{(R)}$ and Gadovist$^{(R)}$.

Digital subtraction angiography(DSA) of hepatic artery using selective catheterization technique in beagle dogs (비글견에서 선택적 카테터 삽관법을 이용한 간동맥의 디지털 감산 혈관조영술)

  • Chang, Dong-woo;Yun, Young-min;Kim, Bong-kyeong;Lee, Young-won;Yoon, Jung-hee;Kweon, Oh-kyeong;Seong, Je-kyung
    • Korean Journal of Veterinary Research
    • /
    • v.39 no.3
    • /
    • pp.665-671
    • /
    • 1999
  • The aim of this study was to establish selective hepatic artery catheterization technique through percutaneous femoral artery puncture and to offer digital subtraction angiography (DSA) of hepatic artery in beagle dogs. Percutaneous femoral artery puncture was performed with Sheldinger's method. Microferret$^{TM}$-18 Infusion catheter(William, Cook, Europe) was introduced into abdominal aorta. Then, under fluoroscopy, iopamidol 370(Bracco, Italy) was injected to identify celiac artery and 'J' shaped guide wire was introduced into celiac artery. Catheter could be introduced into celiac artery through guide wire. In this manner, catheter was located at the insertion of hepatic artery and DSA was performed. In DSA of beagle dogs, hepatic artery which was divided into lateral branch, right-medial branch, right-lateral branch of hepatic artery, cystic artery and gastroduodenal artery was opacified without superimposition of any other body structure and so was the parenchyme of liver afterward. In autopsy angiographic finding of resected liver, cystic artery, caudate branch, lateral branch, right-medial branch, right-lateral branch and quadrate branch of hepatic artery were identified. It was concluded that selective hepatic artery catheterization technique was a minimally invasive method that facillitated the approach of hepatic artery and DSA was an excellent tool to visualize the vessle of liver in dogs.

  • PDF