• Title/Summary/Keyword: Ionized water

Search Result 150, Processing Time 0.029 seconds

The Effect of Commercially Available Mouth Rinsing Solution and Alkaline Ionized Water on the Oral Bacteria (시판되는 구강 양치액과 알칼리 이온수가 구강 내 세균에 미치는 효과)

  • Park, Seon-Nyeo;Jeong, Soon-Jeong;Jeong, Moon-Jin;Ahn, Yong-Soon;Choi, Yoo-Seok;Lim, Do-Seon
    • Journal of dental hygiene science
    • /
    • v.13 no.2
    • /
    • pp.213-221
    • /
    • 2013
  • The mouth rinsing solution currently on the market is used for oral hygiene and reduction of halitosis, and alkaline ionized water is used for drinking purposes. The aim of this germiculture and observation through a microscope is to investigate the effect they have on the oral bacteria, and the results are as follows. 1. The change in the number of cultivated bacteria before and after the use of gargle was most dramatic for Hexamedin. It showed the highest rate of decrease in bacteria by 71.29%, followed by Listerine with 62.25%, Caregargle with 42.26%, Garglin with 33.52%, saline solution with 21.62%, alkaline ionized water with 16.08% and distilled water with 7.67%. 2. After careful analysis of statistics, Hexamedin was found to result in a significant decrease in the number of bacteria after gargling (p<0.05). 3. From observing through an light microscope after gram staining, it was evident that both a number of cocci and a few of filamentous were present before the use of gargle, whereas mostly cocci was present after the use of gargle. 4. The difference in the pH of oral rinses and alkaline ionized water had no significant influence on the number of oral bacteria. In conclusion, Hexamedin and Listerine, with the rate of decrease of bacteria of co71.29% and 62.25% respectively, have proven to be highly effective when applied before dental treatment. Other oral rinses and alkaline ionized water are relatively less efficient in decreasing the number of oral bacteria. Also, the decrease of bacteria is more affected by the antibacterial component of oral rinses than by the change in pH.

A Study on the Characteristics of the High Concentration Ozone Generator for the Semiconductor Wafer Cleaning with the Ozone Dissolved De-ionized Water (반도체 웨이퍼의 오존 수(水) 세정을 위한 고농도 오존발생장치 특성 연구)

  • 손영수;함상용;문세호
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.52 no.12
    • /
    • pp.579-585
    • /
    • 2003
  • Recently the utilization of the ozone dissolved de-ionized water(DI-O3 water) in semiconductor wet cleaning process to replace the conventional RCA methods has been studied. In this paper, we propose the water-electrode type ozone generator which has the ozone gas characteristics of the high concentration and high purity to produce the high concentration DI-O3 water for the silicon wafer surface cleaning process. The ozone generator has the dual dielectric tube structure of silent discharge type and the water is both used to electrode and cooling water. We investigate the performance of the proposed ozone generator which has the design goal of the concentration of 7[wt%] and ozone generation quantity of 6[g/hr] at flow rate of 1[$\ell$/min). The experiment results show that the water electrode type ozone generator has the characteristics of 8.48[wt%] of concentration, 8.08[g/hr] of generation quantity and 76.2[g/kWh] of yield and it's possible to use the proposed ozone generator for the DI-O3 water cleaning process of silicon wafer surface.

Electrohydrodynamic Drop Formation Processes of a Needle-Centered Nozzle Electrode (침심 노즐전극의 전기 유체역학적 액적 형성과정)

  • Moon, Jae-Duk
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.10
    • /
    • pp.1807-1811
    • /
    • 2008
  • In this paper, the meniscus formation/deformation processes and conduction characteristics of the needle-centered ceramic nozzle electrode as an effective electrohydrodynamic (EHD) flow driving mechanisms for de-ionized water and silicone oil have been investigated. Results showed that the applied high voltage affected significantly on the processes, such as the drop formation mode, the deformation mode, the dripping mode, the jet mode, and the atomization mode. There was the EHD atomization mode for the de-ionized water while it was not occurred for the silicone oil, which, however, might be due to the lower electric conductivity and dielectric property of the oil than that of the water.

Influence of Alkyl Chain Length on Fragmentations and Ion-Molecule Reactions of Ionized c-C6H11-(CH2)nCO2H

  • Choi, Sung-Seen;So, Hun-Young
    • Bulletin of the Korean Chemical Society
    • /
    • v.26 no.11
    • /
    • pp.1711-1716
    • /
    • 2005
  • Fragmentations and ion-molecule reactions of ionized cyclohexane propionic acid and cyclohexane butyric acid were studied using FTMS and theoretical calculations. The difference in bond dissociation depending on the aliphatic chain length was investigated and mechanisms for the possible rearrangements depending on the aliphatic carbon length were suggested. The most abundant fragment ion of the ionized cyclohexane propionic acid was c-$C_6H_{11}CH_2\;^+$ formed from the molecular ion by the direct C-C bond cleavage, while that of the ionized cyclohexane butyric acid was c-$C_6H_9C(OH)=OH^+$ formed by rearrangement of the molecular ion from the acid to diol form and loss of propyl radical. Stabilities of the radical and distonic ions of $C_nH_{2n}O^{+\bullet}$ formed from the molecular ion were compared. Protonated molecules were dissociated into smaller ions by losing one or two water molecules. The $[nM + H]^+$, $[nM + H - H_2O]^+$, and $[nM + H - 2H_2O]^+$ with n = 2 and 3 were generated by solvation with the neutral molecules in the ICR cell at long ion trapping time.

A study on the Oxide CMP Characteristics using New Abrasive (새로운 연마제를 이용한 Oxide CMP 특성에 관한 연구)

  • Han, Sung-Min;Han, Sang-Jun;Park, Sung-Woo;Lee, Woo-Sun;Seo, Yong-Jin
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.11a
    • /
    • pp.378-379
    • /
    • 2006
  • CMP(chemical mechanical polishing) process has been attracted as an essential technology of multi-level interconnection. However, the COO(cost of ownership) is very high, because of high consumable cost. Especially, among the consumables, slurry dominates more than 40 %. So, we focused how to reduce the consumption of raw slurry. In this paper, $ZrO_2$, $CeO_2$, and $MnO_2$ abrasives were added de-ionized water (DIW) and pH control as a function of KOH contents. We have investigate the possibility of new abrasive for the oxide CMP application.

  • PDF

The Clinical Study on the Effect of Spread Acidic Ionized Water on Acnes Disease (산성수 도포가 면포에 미치는 임상적 연구)

  • Seo, Hyung-sik;Hong, Seok-hoon
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • v.16 no.1
    • /
    • pp.154-158
    • /
    • 2003
  • Objectives : The purpose of this study was to search liquid that mixing with powder drug on acnes disease. Conclusions : Out of acne patients who visited Oriental Medicine Hospital of Han-Seo University during December 2002 - February 2003, four female and five male were treated over four weeks. The average age were 21.44 years old. Before treatment, acne patients were sparsely with papules at the forehead, cheeks, lower jaw. After treatment during four weeks, seven acne patients change for the better, 77.8$\%$(mild improved 55.5$\%$, improved 11.1$\%$, much improved 11.1$\%$)

  • PDF

The Study of Thyristor Valve Water Cooling Control Systems (대전력 반도체 정류기 수냉식 냉각 설비 냉매 온도 제어시스템에 관한 연구)

  • 임익헌;류호선
    • Proceedings of the KIPE Conference
    • /
    • 1999.07a
    • /
    • pp.230-233
    • /
    • 1999
  • The design and implementation of thyristor water cooling control systems in considered in this pape Coolant water is pumped through the thyristor heat sinks where heat is transferred from the thyristo to the water. This water is then pumped through outdoor air-to-water heat exchangers where heat I transferred to the outside air. Since the water must be pure, it is filtered and de-ionized. Also the water temperature must be below dew-point temperature. Redundant pumps, outdoor heat exchangers, power supply system, controller monitoring system are provided for system reliability and availability.

  • PDF

Cleansing effect of the alkaline ionized water on microorganisms of the denture surface (알칼리 이온수의 의치 미생물에 대한 세정효과에 관한 연구)

  • Kim, Young-Mi;Choi, Yu-Sung;Cho, In-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.49 no.2
    • /
    • pp.138-144
    • /
    • 2011
  • Purpose: The purpose of this study was to evaluate the cleansing effect of recently developed alkaline ionized water, e-WASH, on microorganisms of the denture surface. Materials and methods: Removable partial and complete dentures were randomly assigned to the experimental group of 41 dentures, and the control group of 26. The denture was immersed in the e-WASH solution (experimental group), or tap water (control group) for 5 minutes. The plaque was collected from the denture surface before and after immersion, and smeared on the slide glass. Amount and motility of microorganisms were compared according to the morphology and strain of microorganisms, using the phase contrast microscope. Statistical analysis was accomplished with paired t-test and independent t-test at 95% confidence level (P<.05). Results: 1. The amount of cocci, bacilli, filamentous, spiral/comma, and the motility of bacilli, filamentous, and spiral/comma were decreased after denture cleansing with the alkaline ionized water, e-WASH (P<.05). But in the control group, only the amount of cocci showed a significant difference (P<.05), but no difference from the others. There were no differences in other analysis. 2. In the experimental group, the amount of cocci, bacilli, filamentous, spiral/comma, and the motility of bacilli, filamentous, and spiral/comma were smaller and more inactive compared to the control group (P<.05). Conclusion: These results indicated that the alkaline ionized water, e-WASH could effectively reduce the amount and motility of the experimented microorganisms on the denture surface, and that e-WASH could be recommended as an effective denture cleanser.