• Title/Summary/Keyword: Ionization rate

Search Result 265, Processing Time 0.029 seconds

Quantitative Analysis of the Seventeen Marker Components in Dangguisu-san Using Ultra-performance Liquid Chromatography Coupled to Electrospray Ionization Tandem Mass Spectrometry (LC-MS/MS를 이용한 당귀수산 추출물 중 17종 성분의 함량분석)

  • Seo, Chang-Seob;Shin, Hyeun-Kyoo
    • YAKHAK HOEJI
    • /
    • v.58 no.3
    • /
    • pp.158-164
    • /
    • 2014
  • Dangguisu-san is a well-known traditional Korean herbal medicine prescription and has been widely used to treat ecchymosis, blood stagnation, and pain resulting from physical shock in Korea. In this study, an ultra-performance liquid chromatography-electrospray ionization-mass spectrometer method was established for the simultaneous determination of the 17 biomarker components in Dangguisu-san. All analytes were separated on an UPLC BEH $C_{18}$ ($100{\times}2.1$ mm, $1.7{\mu}m$) column and maintained at $45^{\circ}C$. The mobile phase consisted of two solvent systems, 0.1% (v/v) formic acid in water (A) and acetonitrile (B) by gradient flow. The injection volume was $2.0{\mu}l$ and the flow rate was 0.3 ml/min with detection at mass spectrometer. Calibration curves of the 17 biomarker components were acquired with $r^2$ values ${\geq}0.9951$. The values of limit of detection and quantification of all analytes were 0.02~6.32 ng/ml and 0.05~18.95 ng/ml, respectively. The amounts of the 17 components in Dangguisu-san sample were $3.17{\sim}13,224.50{\mu}g/g$.

Study on the Various Size Dependence of Ionization Chamber in IMRT Measurement to Improve Dose-accuracy (세기조절 방사선치료(IMRT)의 환자 정도관리에서 다양한 이온전리함 볼륨이 정확도에 미치는 영향)

  • Kim, Sun-Young;Lee, Doo-Hyun;Cho, Jung-Keun;Jung, Do-Hyeung;Kim, Ho-Sick;Choi, Gye-Sook
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.18 no.1
    • /
    • pp.1-5
    • /
    • 2006
  • Purpose: IMRT quality assurance(Q.A) is consist of the absolute dosimetry using ionization chamber and relative dosimetry using the film. We have in general used 0.015 cc ionization chamber, because small size and measure the point dose. But this ionization chamber is too small to give an accurate measurement value. In this study, we have examined the degree of calculated to measured dose difference in intensity modulated radiotherapy(IMRT) based on the observed/expected ratio using various kinds of ion chambers, which were used for absolute dosimetry. Materials and Methods: we peformed the 6 cases of IMRT sliding-window method for head and neck cases. Radiation was delivered by using a Clinac 21EX unit(Varian, USA) generating a 6 MV x-ray beam, which is equipped with an integrated multileaf collimator. The dose rate for IMRT treatment is set to 300 MU/min. The ion chamber was located 5cm below the surface of phantom giving 100cm as a source-axis distance(SAD). The various types of ion chambers were used including 0.015cc(pin point type 31014, PTW. Germany), 0.125 cc(micro type 31002, PTW, Germany) and 0.6 cc(famer type 30002, PTW, Germany). The measurement point was carefully chosen to be located at low-gradient area. Results: The experimental results show that the average differences between plan value and measured value are ${\pm}0.91%$ for 0.015 cc pin point chamber, ${\pm}0.52%$ for 0.125 cc micro type chamber and ${\pm}0.76%$ for farmer type 0.6cc chamber. The 0.125 cc micro type chamber is appropriate size for dose measure in IMRT. Conclusion: IMRT Q.A is the important procedure. Based on the various types of ion chamber measurements, we have demonstrated that the dose discrepancy between calculated dose distribution and measured dose distribution for IMRT plans is dependent on the size of ion chambers. The reason is small size ionization chamber have the high signal-to-noise ratio and big size ionization chamber is not located accurate measurement point. Therefore our results suggest the 0.125 cc farmer type chamber is appropriate size for dose measure in IMRT.

  • PDF

Dependence of Device Performance and Reliability on Channel Direction in PMOSFET's (PMOSFET에서 채널 방향에 대한 소자 성능 의존성)

  • Bok, Jung-Deuk;Park, Ye-Ji;Han, In-Shik;Kwon, Hyuk-Min;Park, Byoung-Seok;Park, Sang-Uk;Lim, Min-Gyu;Chung, Yi-Sun;Lee, Jung-Hwan;Lee, Hi-Deok
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.23 no.6
    • /
    • pp.431-435
    • /
    • 2010
  • In this paper, we investigated the dependence of device performance and hot carrier lifetime on the channel direction of PMOSFET. $I_{D.sat}$ vs. $I_{Off}$ characteristic of PMOSFET with <100> channel direction is greater than that with <110> channel direction because carrier mobility of <100> channel direction is greater than that of <110> channel direction. However, hot carrier lifetime for <110> channel direction is much lower than that with <110> channel due to the greater impact ionization rate in the <100> channel direction. Therefore, concurrent consideration of reliability characteristics and device performance is necessary for channel strain engineering of MOSFETs.

Simultaneous analysis of sulfonamides in beef and pork by high performance liquid chromatography and electrospray ionization mass spectrometry (HPLC와 LC/MS에 의한 식육내 잔류 설파제의 동시 분석법)

  • 정봉수;박준조;금모래;김인경;박병옥;한정희
    • Korean Journal of Veterinary Service
    • /
    • v.27 no.1
    • /
    • pp.17-29
    • /
    • 2004
  • A multiresidual analysis was performed to determine 12 sulfonamides(sulfacetamide, sulfadiazine, sulfisomidine, sulfathiazole, sulfapyridine, sulfamerazine, sulfamethazine, sulfamonomethoxine, sulfisoxazole, sulfamethoxazole, sulfaquinoxaline, and sulfadimethoxine) in beef and pork simultaneously. The multiresidual analysis for the sulfonamides currently used was able to analyze 5 kinds of sulfonamides at the same time. The method of this 12 sulfonamides multiresidual analysis in this study was matrix solid-phase dispersion(MSPD) by high performance liquid chromatography (HPLC) and liquid chromatography mass spectrometry (LC/MS). The recovery rate of the materials was measured by MSPD method with 3 different extraction solvents; Dichloromethane, DCM: Ethylacetate(3:1), DCM:EA(9:1). Also, samples (84 beef and 205 pork samples) which were positive by EEC-4 plate test from 2001 to 2003 were tested to investigate the kinds of sulfonamides using HPLC. The results from the study were as follows; 1. The recovery rate of the materials was measured by MSPD method with 3 different extraction solvents; Dichloromethane, DCM:Ethylacetate(3:1), DCM:EA(9:1). The method of extraction solvent with DCM:ethyl acetate(9:1) was the most excellent(87.7∼99.3%) in separation and reappearance. 2. In the LC/MS analysis. of sulfonamides, signal to noise ratio was showed relatively high in the positive mode and special ion in the quality analysis was determined via [M+H]$\^$+/ and m/z 156. A spectrum of sulfonamides was showed from all 12 sulfonamides. 3. The samples positive by the EEC-4 plate, a screening test method, were categorized by sulfonamides through Charm II and confirmed the kinds of sulfonamides through HPLC. 1) Among 84 beef samples positive by EEC-4 plate, 20 samples were positive by Charm II and identified as 7 sulfamethazine, 9 sulfadimethoxine, 1 sulfamonomethoxine and 3 unknown status. 2) Among 205 pork samples positive by EEC-4 plate, 42 samples were positive by Charm II and identified as 19 sulfamethazine, 1 sulfadimethoxine, 4 sulfamonomethoxine and 5 unknown status.

Diamond Schottky Barrier Diodes With Field Plate (필드 플레이트가 설계된 다이아몬드 쇼트키 장벽 다이오드)

  • Chang, Hae Nyung;Kang, Dong-Won;Ha, Min-Woo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.4
    • /
    • pp.659-665
    • /
    • 2017
  • Power semiconductor devices required the low on-resistance and high breakdown voltage. Wide band-gap materials opened a new technology of the power devices which promised a thin drift layer at an identical breakdown voltage. The diamond had the wide band-gap of 5.5 eV which induced the low power loss, high breakdown capability, low intrinsic carrier generation, and high operation temperature. We investigated the p-type pseudo-vertical diamond Schottky barrier diodes using a numerical simulation. The impact ionization rate was material to calculating the breakdown voltage. We revised the impact ionization rate of the diamond for adjusting the parallel-plane breakdown field at 10 MV/cm. Effects of the field plate on the breakdown voltage was also analyzed. A conventional diamond Schottky barrier diode without field plate exhibited the high forward current of 0.52 A/mm and low on-resistance of $1.71{\Omega}-mm$ at the forward voltage of 2 V. The simulated breakdown field of the conventional device was 13.3 MV/cm. The breakdown voltage of the conventional device and proposed devices with the $SiO_2$ passivation layer, anode field plate (AFP), and cathode field plate (CFP) was 680, 810, 810, and 1020 V, respectively. The AFP cannot alleviate the concentration of the electric field at the cathode edge. The CFP increased the breakdown voltage with evidences of the electric field and potential. However, we should consider the dielectric breakdown because the ideal breakdown field of the diamond is higher than that of the $SiO_2$, which is widely used as the passivation layer. The real breakdown voltage of the device with CFP decreased from 1020 to 565 V due to the dielectric breakdown.

A Study on the Flame Behavior of Substitute Fuel of Gasoline Engine (가솔린엔진용 대체연료의 화염거동에 관한 연구)

  • Yang, Jeong-Gyu;Ryu, Jeong-In
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.21 no.2
    • /
    • pp.157-166
    • /
    • 1985
  • The Purpose of this study are to investigate the characteristics of the flame behavior of gasoline-methanol blended fuels in spark ignition engine. Ionization probe were installed at the cylinder head and piston in order to measure flame speed. Other parameter such as engine performance, fuel consumption rate and exhaust gas were measured. The results were as follows. 1. In the case of increase methanol contents in blend fuel, flame propagation speed were increased, and thermal efficiency of the engine were increased due to decrease of energy consumption rate. 2. In the case of fixed equivalance ratio, NO sub(X) in exhaust gas were increased in accordance with increase of spark advance, and mean effective pressure were decreased in accordance with increase of methanol contents. 3. CO and HC concentration were decreased in accordance with increase of methanol contents.

  • PDF

LONG-SLIT SPECTROSCOPY OF PARSEC-SCALE JETS FROM DG TAURI

  • Oh, Heeyoung;Pyo, Tae-Soo;Yuk, In-Soo;Park, Byeong-Gon
    • Journal of The Korean Astronomical Society
    • /
    • v.48 no.2
    • /
    • pp.113-123
    • /
    • 2015
  • We present observational results from optical long-slit spectroscopy of parsec-scale jets of DG Tau. From HH 158 and HH 702, the optical emission lines of Hα, [O i] λλ6300, 6363, [N ii] λλ6548, 6584, and [S ii] λλ6716, 6731 are obtained. The kinematics and physical properties (i.e., electron density, electron temperature, ionization fraction, and mass-loss rate) are investigated along the blueshifted jet up to 650′′ distance from the source. For HH 158, the radial velocity ranges from −50 to −250 km s−1. The proper motion of the knots is 0.′′196 − 0.′′272 yr−1. The electron density is ∼104 cm−3 close to the star, and decreases to ∼102 cm−3 at 14′′ away from the star. Ionization fraction indicates that the gas is almost neutral in the vicinity of the source. It increases up to over 0.4 along the distance. HH 702 is located at 650′′ from the source. It shows ∼ −80 km s−1 in the radial velocity. Its line ratios are similar to those at knot C of HH 158. The mass-loss rate is estimated to be about ∼ 10−7 M yr−1, which is similar to values obtained from previous studies.

Study of Solvent Effects on the Ionization of tert-butyl Halide in MeOH-DMSO Mixtures (MeOH-DMSO 혼합용매중에서 tert-butyl halide의 이온화에 미치는 용매효과)

  • Yeol Sakong;Shi Choon Kim;Jin Sung Kim;Bon Su Lee
    • Journal of the Korean Chemical Society
    • /
    • v.29 no.1
    • /
    • pp.45-51
    • /
    • 1985
  • Rate constants and activation parameters for the methanolysis of t-butyl halide (t-BuCl, t-BuBr, t-BuI) in various MeOH-DMSO mixtures were measured by conductometric method. Taft's solvatochromic parameters, such as polarity-polarizability(SPP's), ${\pi}^{\ast}$, hydrogen bond donor (HBD) acidity, ${\alpha}$, and hydrogen bond acceptor (HBA) basicity, ${\beta}$ of the solvents, were determined by the so called solvatochromic method using five indicators. The variation of methanolysis rate with the solvent composition was discussed on the basis of the activation parameters and the correlation of the rates with the solvatochromic parameters. It is concluded that the polarity-polarizability, HBD acidity and HBA basicity of the mixtures had an effect on the ionization of t-butyl halide cooperatively, also that the specific interaction between the leaving groups and the solvents, such as ion-dipole and hydrogen bond acceptor-donor interaction, is the most important factor of solvent effects on the stabilization of transition states.

  • PDF

High-Dose-Rate Electron-Beam Dosimetry Using an Advanced Markus Chamber with Improved Ion-Recombination Corrections

  • Jeong, Dong Hyeok;Lee, Manwoo;Lim, Heuijin;Kang, Sang Koo;Jang, Kyoung Won
    • Progress in Medical Physics
    • /
    • v.31 no.4
    • /
    • pp.145-152
    • /
    • 2020
  • Purpose: In ionization-chamber dosimetry for high-dose-rate electron beams-above 20 mGy/pulse-the ion-recombination correction methods recommended by the International Atomic Energy Agency (IAEA) and the American Association of Physicists in Medicine (AAPM) are not appropriate, because they overestimate the correction factor. In this study, we suggest a practical ion-recombination correction method, based on Boag's improved model, and apply it to reference dosimetry for electron beams of about 100 mGy/pulse generated from an electron linear accelerator (LINAC). Methods: This study employed a theoretical model of the ion-collection efficiency developed by Boag and physical parameters used by Laitano et al. We recalculated the ion-recombination correction factors using two-voltage analysis and obtained an empirical fitting formula to represent the results. Next, we compared the calculated correction factors with published results for the same calculation conditions. Additionally, we performed dosimetry for electron beams from a 6 MeV electron LINAC using an Advanced Markus® ionization chamber to determine the reference dose in water at the source-to-surface distance (SSD)=100 cm, using the correction factors obtained in this study. Results: The values of the correction factors obtained in this work are in good agreement with the published data. The measured dose-per-pulse for electron beams at the depth of maximum dose for SSD=100 cm was 115 mGy/pulse, with a standard uncertainty of 2.4%. In contrast, the ks values determined using the IAEA and AAPM methods are, respectively, 8.9% and 8.2% higher than our results. Conclusions: The new method based on Boag's improved model provides a practical method of determining the ion-recombination correction factors for high dose-per-pulse radiation beams up to about 120 mGy/pulse. This method can be applied to electron beams with even higher dose-per-pulse, subject to independent verification.

Quality Correction for Ir-192 Gamma Rays in Air Kerma Strength Dosimetry Using Cylindrical Ionization Chambers (원통형 전리함을 이용한 Ir-192 선원에 대한 공기커마세기 측정 시 선질보정에 관한 연구)

  • Jeong, Dong-Hyeok;Kim, Jhin-Kee;Kim, Ki-Hwan;Oh, Young-Kee;Kim, Soo-Kon;Lee, Kang-Kyoo;Moon, Sun-Rock
    • Progress in Medical Physics
    • /
    • v.20 no.1
    • /
    • pp.30-36
    • /
    • 2009
  • The quality correction in the air kerma dosimetry for Ir-192 using farmer type ionization chambers calibrated by Co-60 quality is required. In this study we determined quality factor ($k_u$) of two ionization chambers of PTW-N30001 and N23333 for Ir-192 source using dosimetric method. The quality factors for energy spectrum of microSelectron were determined as $k_u$=1.016 and 1.017 for PTW-N30001 and N23333 ionization chambers respectively. We applied quality factors in air kerma dosimetry for microSelectron source and compared with reference values. As a results we found that the differences between reference air kerma rate and measured it with and without quality correction were about -0.5% and -2.0% respectively.

  • PDF