• Title/Summary/Keyword: Ion-Exchange

Search Result 2,134, Processing Time 0.027 seconds

Comparative Study on Recovery of Nickel by Ion Exchange and Electrodialysis (이온교환과 전기투석을 이용한 니켈회수의 비교연구)

  • Sim, Joo-Hyun;Seo, Hyung-Joon;Seo, Jae-Hee;Kim, Dae-Hwan
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.6
    • /
    • pp.640-647
    • /
    • 2006
  • It is difficult to treat wastewater involved in heavy metal in electroplating industry. Recently, many industries adopt the clean technology to prevent production of pollutant in the process or reuse after the appropriate pollutant treatment. In this study, we estimate the ability of recovery of nickel and the efficiency using lab-scale ion exchange and electrodialysis process with electroplating industry wastewater. In the ion exchange experiments with 5 types of resin, the result showed that S 1467(gel-type strong acidic cation exchange resin) has the highest exchange capacity. And it showed that the 4 N HCl has the highest in regeneration efficiency and maximum concentration in the regeneration experiments with various kinds md concentration of the regenerant. During the electrodialysis experiments, we varied the current density, the concentration of electrode rinse solution, the flow rate of concentrate and electrode rinse solution in order to find the optimum operating condition. As a result, we obtained $250A/m^2$ of current density, 2 N $H_2SO_4$ of concentration of electrode rinse solution, 30 mL/min of flow rate of concentrate and electrode rinse solution as the best operating conditions. We performed the scale-up experiments on the basis of ion exchange and electrodialysis experiments. And we obtained the experimental result that exchange capacity of S 1467 was 1.88 eq/L resin, and regeneration efficiency was 93.7% in the ion exchange scale-up experiment, we also got the result that concentration and dilution efficiency increased, and current efficiency kept constant in the scale-up experiments.

A study on the optimization of Ion Exchange Resin operating conditions for removal of KCl from CKD extract (CKD 추출액내 KCl 제거를 위한 이온교환수지 조업조건 최적화 연구)

  • Jang, Younghee;Lee, Ye Hwan;Kim, Jiyu;Park, Il Gun;Lee, Ju-Yeol;Park, Byung Hyun;Kim, Seong-Cheol;Lee, Sang Moon;Kim, Sung Su
    • Journal of the Korean Applied Science and Technology
    • /
    • v.36 no.4
    • /
    • pp.1088-1095
    • /
    • 2019
  • The CKD extract is wastewater from which KCl in CKD has been removed to reuse CKD as a cement raw material, and tried to reuse no extracts due to problems such as wastewater treatment facility expansion. As a result of removing KCl by the ion exchange method, the pH of the extract after ion exchange decreased from 12.7 to less than pH 2, and it was confirmed that H+ of the cation exchange resin was dissolved in the extract through ion exchange. In addition, the selectivity of the ion exchange was removed in the order of Ca2+, K+, it was determined that the increase in the contact time to remove the K+ ions. The batch system had a contact time of 6 times or more, compared to the continuous system, and showed 4 times of K+ removal efficiency and 7 times of Cl- removal efficiency. It was showed by analyzing the pH of the extract that more H+ of the cation exchange resin was extracted than OH- of anion exchange resin as the pH of the extract was changed.

Study on the Preparation of Polyvinyl Chloride Anion Exchange Membrane as a Separator in the Alkaline Water Electrolysis (알칼리 수전해용 격막으로서 폴리염화비닐(polyvinyl chloride) 음이온교환막의 제조에 관한 연구)

  • Park, Jong-Ho;Bong, Soo-Yeon;Ryu, Cheol-Hwi;Hwang, Gab-Jin
    • Membrane Journal
    • /
    • v.23 no.6
    • /
    • pp.469-474
    • /
    • 2013
  • An anion exchange membrane was prepared for a separator in the alkaline water electrolysis. An anion exchange membrane was prepared by the chloromethylation and amination of polyvinyl chloride (PVC) used as a base polymer. The membrane properties of the prepared anion exchange membrane such as the membrane resistance and ion exchange capacity were measured. The minimum membrane resistance of the prepared anion exchange membrane was $2.9{\Omega}{\cdot}cm^2$ in 1M NaOH aq. solution. This membrane had 2.17 meq./g-dry-membrane and 43.4% for the ion exchange capacity and water content, respectively. The membrane properties of the prepared anion exchange membrane was compared with that of the commercial anion exchange membrane. The membrane resistance decreased in the order; AHT>IOMAC> Homemade membrane> AHA>APS=AFN. The ion exchange capacity decreased in the order; Homemade membrane>AFN>APS>AHT>AHA>IOMAC.

Electrochemical Characteristics of Ion-Exchange Membrane and Charged Mosaic Membrane (복합 하전 모자이크 막과 이온교환 막의 전기적화학적 특성)

  • Yang, Wong-Kang;Song, Myung-Kwan;Cho, Young-Suk
    • Membrane Journal
    • /
    • v.17 no.1
    • /
    • pp.37-43
    • /
    • 2007
  • The effect of anionic and cationic exchange polymer layer on the chronopotentiometry (CP) and current voltage curves (I-V) of charged composite membrane are investigated. Also, the ion transport near the interface between electrolyte and ionic exchange polymer membranes (anionic and cationic ones) and charged mosaic polymer composite membrane is studied. The results show that both anionic and cationic polymer exchange membranes exhibit lower voltage drop over range of applied current density and possess favorable industrial application potentials, especially at low KCl concentration. While the charged mosaic polymer composite membrane didn't show any current-voltage change, irrespective to the type and the concentration of used electrolyte. CP and I-V measurements are effectively used to give some fundamental understanding for ion transport behavior of ion exchange polymer membrane near the interlace.

Excess proton catalyzed H/D exchange reaction at the ice surface

  • Moon, Eui-Seong;Kang, Heon
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.333-333
    • /
    • 2011
  • We studied the H/D exchange kinetics of pure and acid dopped water-ice film by using the techniques of reactive ions scattering (RIS) and low energy sputtering (LES) with low kinetic energy cesium ion beam (<35 eV). From RIS, neutral water isotopomers were detected in the form of cesium-molecule ion clusters, $CsX^+$ (X= $H_2O$, HDO, $D_2O$). Ionic species, like $H_3O^+$, $DH_2O^+$, $D_2HO^+$, $D_3O^+$, adsorbed on the surface were ejected via LES process. Those techniques allowed us to trace the isotopomeric populations of water-ice film. To show the catalytic effect of excess proton in the H/D exchange reaction, our study was conducted with two types of water-ice films. In film 1, about 0.5 BL of $H_2O$ was adsorbed on HCl (0.1 ML) dopped $D_2O$ (8 BL) film. In film 2, similar amount of $H_2O$ used in film 1 was adsorbed on pure $D_2O$ film. Kinetic data were obtained from each film type for 90-110 K (film 1) and 110-130 K (film 2) and fitted with numerically integrated lines. Through the Arrhenius plot of kinetic coefficient deduced from fitting of the H/D exchange reaction, the activation energy of film 1 and 2 were estimated to be $10{\pm}3kJmol^{-1}$ and $17{\pm}4kJmol^{-1}$. This activation barrier difference could be understood from detailed pictures of H/D exchange. In film 2, both the formation of ion pair, $H_3O^+$ and OH. and proton transfer were needed for the H/D exchange. However, in film 1, only proton transfer was necessary but ion pair formation was not, so this might reduce the activation energy.

  • PDF

Ion Exchange of Ultrafiltrated Soybean Cooking Water for the Production of Soy-oligosaccharides (대두올리고당 생산을 위한 한외여과 대두침출액의 이온교환)

  • Ku, Kyung-Hyung;Park, Dong-June;Mok, Chul-Kyoon
    • Korean Journal of Food Science and Technology
    • /
    • v.27 no.3
    • /
    • pp.313-317
    • /
    • 1995
  • Ion exchange process was optimized to purify ultrafiltrated bean cooking water(BCW) for the production of soy-oligosaccharides. The ultrafiltrated BCW with cutoff MW(COMW) 20,000 membrane was treated with various ion exchange resins. Protein and ash were mostly removed by anion and cation exchange resins, respectively. Based upon removing capabilities for ash and protein, a cation exchange resin(SK1B) and an anion exchange resin(WA30) were selected. Protein and ash were more efficiently removed at low extract/resin ratios(ERR), but part of the oligosaccharides were concomitantly lost. When 2-step-ultrafiltrated BCW first with COMW 20,000 membrane and successively with COMW 5,000 membrane was treated with a mixed resin(SK1B : WA30 =1 : 2) at ERR 5.0, most oligosaccharides were recovered in a clear protein- and ash-free liquid.

  • PDF

A Review Based on Ion Separation by Ion Exchange Membrane (이온교환막을 통한 이온분리에 대한 총설)

  • Assel, Sarsenbek;Patel, Rajkumar
    • Membrane Journal
    • /
    • v.32 no.4
    • /
    • pp.209-217
    • /
    • 2022
  • Ion exchange membrane (IEM) is an important class of membrane applied in batteries, fuel cells, chloride-alkali processes, etc to separate various mono and multivalent ions. The membrane process is based on the electrically driven force, green separation method, which is an emerging area in desalination of seawater and water treatment. Electrodialysis (ED) is a technique in which cations and anions move selectively along the IEM. Anion exchange membrane (AEM) is one of the important components of the ED process which is critical to enhancing the process efficiency. The introduction of cross-linking in the IEM improves the ion-selective separation performance due to the reduction of free volume. During the desalination of seawater by reverse osmosis (RO) process, there is a lot of dissolved salt present in the concentrate of RO. So, the ED process consisting of a monovalent cation-selective membrane reduces fouling and improves membrane flux. This review is divided into three sections such as electrodialysis (ED), anion exchange membrane (AEM), and cation exchange membrane (CEM).

Studies on Preparation and Ion Exchange Characteristics of Humic Acid Membranes (Humic Acid 분리막의 제조와 이온교환 특성에 관한 연구)

  • 이용택
    • Membrane Journal
    • /
    • v.7 no.3
    • /
    • pp.136-141
    • /
    • 1997
  • Humic acid has been extracted and purified from biologically nondegradable humic substances. Using the ion exchange capability of carboxylic acids which are the main component of the humic acids, a membrane was prepared with poly(viny1 alcohol). Its transport behavior of biologically active ions, $K^+$and $Na^+$, were investigated. The ion transport velocity increased with hydrogen ion concentration, especially, in the range of $10^-1$~$10^0$. The selectivity increased with increasing the concentrations of $K^{+}$ and Na$^{+}$, In particular, the transport velocity of $K^+$ increased twice compared to that of $Na^+$ at the 100 hydrogen ion concentration. In this regards, humic acid may be used as a new material for ion exchange membranes.

  • PDF