• Title/Summary/Keyword: Ion selective membrane

Search Result 204, Processing Time 0.024 seconds

A Study on Particle and Crystal Size Analysis of Lithium Lanthanum Titanate Powder Depending on Synthesis Methods (Sol-Gel & Solid-State reaction) (분말 합성법(Sol-Gel & Solid-State reaction)에 따른 Lithium Lanthanum Titanate 분말의 입자 및 결정 크기 비교 분석에 관한 연구)

  • Jeungjai Yun;Seung-Hwan Lee;So Hyun Baek;Yongbum Kwon;Yoseb Song;Bum Sung Kim;Bin Lee;Rhokyun Kwak;Da-Woon Jeong
    • Journal of Powder Materials
    • /
    • v.30 no.4
    • /
    • pp.324-331
    • /
    • 2023
  • Lithium (Li) is a key resource driving the rapid growth of the electric vehicle industry globally, with demand and prices continually on the rise. To address the limited reserves of major lithium sources such as rock and brine, research is underway on seawater Li extraction using electrodialysis and Li-ion selective membranes. Lithium lanthanum titanate (LLTO), an oxide solid electrolyte for all-solid-state batteries, is a promising Li-ion selective membrane. An important factor in enhancing its performance is employing the powder synthesis process. In this study, the LLTO powder is prepared using two synthesis methods: sol-gel reaction (SGR) and solid-state reaction (SSR). Additionally, the powder size and uniformity are compared, which are indices related to membrane performance. X-ray diffraction and scanning electron microscopy are employed for determining characterization, with crystallite size analysis through the full width at half maximum parameter for the powders prepared using the two synthetic methods. The findings reveal that the powder SGR-synthesized powder exhibits smaller and more uniform characteristics (0.68 times smaller crystal size) than its SSR counterpart. This discovery lays the groundwork for optimizing the powder manufacturing process of LLTO membranes, making them more suitable for various applications, including manufacturing high-performance membranes or mass production of membranes.

Electrode Characteristics of K+ Ion-Selective PVC Membrane Electrodes with AC Impedance Spectrum (AC 임피던스 분석법을 이용한 K+ 이온선택성 PVC막 전극 특성)

  • Kim, Yong-Ryul;An, Hyung-Hwan;Kang, An-Soo
    • Applied Chemistry for Engineering
    • /
    • v.9 no.6
    • /
    • pp.870-877
    • /
    • 1998
  • With impedance spectrum measurements, impedance was studied in the interface between sample solutions for $K^+-ion$ selective PVC membrane electrode containing neutral carriers [dibenzo-18-crown-6 (D18Cr6) and valinomycine (Val)]. Response characteristics of electrode were examined by measuring AC impedance spectra that were resulted from the chemical structure and the content of carrier, variation of plasticizer, membrane thickness, doping of base electrolytes, and concentration variation of sample solution. Transport characteristics of PVC membrane electrode were also studied. It was found that the equivalent circuit for the membrane in $K^+$ solution could be expressed by a series combination of solution resistance and a parallel circuit consisting of the bulk resistance and geometric capacitance of the membrane system. But the charge transfer resistance and Warburg resistance were overlapped a little in the low concentration and low frequency ranges. The carrier, D18Cr6 was best for electrode and impedance characteristics, and ideal electrode characteristics were appeared especially in case of doping of the base electrolyte[potassium tetraphenylborate(TPB)]. The optimum carrier content was about 3.23 wt% in case of D18Cr6 and Val. DBP was best as a plasticizer. As membrane thickness decreased the impedance characteristics was improved, but electrode characteristics were lowered for membrane thickness below the optimum. In the case of D18Cr6, the selectivity coefficients by the mixed solution method for the $K^+$ ion were the order of $NH_4{^+}>Ca^{2+}>Mg^{2+}>Na^+$.

  • PDF

Removal of Cd(II) from water using carbon, boron nitride and silicon carbide nanotubes

  • Azamat, Jafar;Hazizadeh, Behzad
    • Membrane and Water Treatment
    • /
    • v.9 no.1
    • /
    • pp.63-68
    • /
    • 2018
  • Molecular dynamics simulations were used to study the removal of Cd(II) as a heavy metal from wastewater using armchair carbon nanotube, boron nitride nanotube and silicon carbide nanotubes under applied electric field. The system contains an aqueous solution of $CdCl_2$ as a heavy metal and a (7,7) nanotube as a nanostructured membrane, embedded in a silicon nitride membrane. An external electric field was applied to the considered system for the removal of $Cd^{2+}$ through nanotubes. The simulation results show that in the same conditions, considered armchair nanotubes were capable to remove $Cd^{2+}$ from wastewater with different ratios. Our results reveal that the removal of heavy metals ions through armchair carbon, boron nitride and silicon carbide nanotubes was attributed to the applied electric field. The selective removal phenomenon is explained with the calculation of potential of mean force. Therefore, the investigated systems can be recommended as a model for the water treatment.

Determination of Verapamil with ISE based on Ion Exchanger (이온교환체 전극을 이용한 베라파밀 정량)

  • Lee, Eun-Yup;Kim, Dong-O;Chang, Seung-Hyun;Hur, Moon-Hye;Ahn, Moon-Kyu
    • YAKHAK HOEJI
    • /
    • v.40 no.2
    • /
    • pp.135-140
    • /
    • 1996
  • Ion-selective poly(vinyl chloride)(PVC) membrane electrodes for the determination of the calcium antagonist verapamil and its pharmaceutical preparations were described. Verapam il-superchrome garnet Y(SGY), lumogallion(LG), acid red 97(AR97), Dragendorff(DD) and Meyer reagent ion pairs were inverstigated as an electroactive compound for membrane electrode. Stable potentiometric response was obtained with azo dye at pH 6.5-4.0 and with DD, and Meyer reagent at pH 6.5-3.0. The best plasticizer was 49w/w% 2-nitrophenyl octyl ether for azo dye, and 65.3w/w% tri(n-butyl) citrate for DD and Meyer reagent. Potentiometric response slopes of optimized membrane electrodes based on SGY, LG, AR97, DD, and Meyer complex for verapamil were 52.49, 54.88, 50.81, 54.13 and 49.31 mV/dec., respectively. Lower limits of linear range were $1.0{\times}10^6M$ for SGY, LG, and AR97, while those for DD and Meyer reagent were $4{\times}10^{-6}M$. Detection limits for all these electrodes were $1{\times}10^{-5}M,\;4{\times}10^{-6}M,\;1.8{\times}10^{-6}M,\;8{\times}10^{-7}M,\;and\;1{\times}10^{-6}M$ with relative standard deviation of 2.56, 3.6, 3.96, 2.56, 3.20%, respectively.

  • PDF

Conceptual Design of Pretreatment Process for SIES Using Membrane Process (막분리 공정을 이용한 SIES 전처리설비 개념 설계)

  • 이상진;양호연;신상운
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2003.11a
    • /
    • pp.15-20
    • /
    • 2003
  • During operation process of SIES(Selective ion exchange system) at Kori Unit 2, it was impossible to remove radionuclides such as ion form and Ag-110m, etc., because activated carbon and ion exchange resin of this system are fouled easily by suspended solids and oils in liquid radwaste that was flowed in this system. In this study, an experiment to improve quality of water which was flowed in SIES was performed. and design data of Scale-up pretreatment process were secured. Also, each module design for Microfiltration and Nanofiltration unit of the pretreatment process for SIES was performed.

  • PDF

Alteration of Ion Selectivity by Mutations within the Pore-forming Region of Small Conductance $Ca^{2+}$-activated $K^+$ Channels

  • Heun Soh;Park, Chul-Seung
    • Proceedings of the Korean Biophysical Society Conference
    • /
    • 2001.06a
    • /
    • pp.36-36
    • /
    • 2001
  • Small conductance $Ca^{2+}$-activated $K^{+}$ channels (or S $K_{Ca}$ channels) are a group of $K^{+}$-selective ion channels activated by sub-micromolar concentrations of intracellular $Ca^{2+}$ independent of membrane voltage. We expressed a cloned S $K_{Ca}$ channel, rSK2, in Xenopus oocytes and investigated the monovalent cation selectivity of the channels. We have used site-directed mutagenesis and macro-channel recordings to identify amino acid residues influencing the ion selectivity.(omitted)d)

  • PDF

Numerical study of effect of membrane properties on long-cycle performance of vanadium redox flow batteries

  • Wei, Zi;Siddique, N.A.;Liu, Dong;Sakri, Shambhavi;Liu, Fuqiang
    • Advances in Energy Research
    • /
    • v.4 no.4
    • /
    • pp.285-297
    • /
    • 2016
  • Fundamental understanding of vanadium ion transport and the detrimental effects of cross-contamination on vanadium redox flow battery (VRFB) performance is critical for developing low-cost, robust, and highly selective proton-conducting membranes for VRFBs. The objective of this work is to examine the effect of conductivity and diffusivity, two key membrane parameters, on long-cycle performance of a VRFB at different operating conditions using a transient 2D multi-component model. This single-channel model combines the transport of vanadium ions, chemical reactions between permeated ions, and electrochemical reactions. It has been discovered that membrane selecting criterion for long cycles depends critically on current density and operating voltage range of the cell. The conducted simulation work is also designed to study the synergistic effects of the membrane properties on dynamics of VRFBs as well as to provide general guidelines for future membrane material development.

Background Non-Selective Cation Channels in Rat Atrial Myocytes

  • Youm, Jae-Boum;Zhang, Yin-Hua;Ho, Won-Kyung;Earm, Yung-E
    • Proceedings of the Korean Biophysical Society Conference
    • /
    • 1998.06a
    • /
    • pp.38-38
    • /
    • 1998
  • Resting membrane potential of atrial myocytes is less negative than K+ equilibrium potential, suggesting the presence of ion channels carrying inward currents. We investigated the background Na$\^$+/ current in rat atrial myocytes using both conventional whole cell voltage clamp technique and single channel recording.(omitted)

  • PDF

Hydrogen ion-selective membrane electrodes based on tetrabenzylalkylenediamine (Tetrabenzylalkylenediamine을 이용한 수소이온 선택성 막전극)

  • Kim, Jae-Woo;Cho, Dong-Hoe;Jeong, Seong-Suk;Chung, Koo-Chun;Park, Myon-Yong
    • Analytical Science and Technology
    • /
    • v.10 no.3
    • /
    • pp.161-167
    • /
    • 1997
  • This is on hydrogen ion-selective memebrane electrodes which were made of tetrabenzylmethylenediamine (TBMDA), tetrabenzylethylenediamine (TBEDA), tetrabenzylpropylenediamine(TBPDA) and tetrabenzylhexylenediamine(TBHDA) as neutral carriers. Their response potentials to carbon number between amino groups showed linear selectivities to hydrogen ion in the range of pH 1~pH 9, pH 2~pH 9, pH 3~pH 9 and pH 4~pH 9 and slopes were 48mV/pH, 52mV/pH, 64mV/pH, 59mV/pH respectively. The interferences effect on the cations were measured to alkali metal ions($Li^+$, $Na^+$, $K^+$), alkaline earth metal ions ($Mg^{2+}$, $Ca^{2+}$, $Sr^{2+}$, $Ba^{2+}$), transition metals ions($Cu^{2+}$, $Ni^{2+}$, $Co^{2+}$) and anions($I^-$, $Br^-$, ${NO_3}^-$, $SCN^-$), and selectivity coefficients were measured by separate-solution method. The membrane electrode made of TBMDA among the electrodes showed the best selectivity in acidic solution.

  • PDF