• Title/Summary/Keyword: Ion extraction

Search Result 605, Processing Time 0.023 seconds

Extraction Equilibria and Solvent Sublation for Determination of Ultra Trace Bi(Ⅲ), In(Ⅲ) and TI(Ⅲ) in Water Samples by Ion-Pairs of Metal-2-Naphthoate Complexes and Tetrabutylammonium Ion

  • Kim, Young-Sang;Choi, Yoon-seok;Lee, Won
    • Bulletin of the Korean Chemical Society
    • /
    • v.23 no.10
    • /
    • pp.1381-1391
    • /
    • 2002
  • The solvent sublation using ion pairs of metal-2-naphthoate(2-HNph) and tetrabutyl ammonium ($TBA^+$) ion has been studied for the concentration and determination of ultra trace Bi(III), In(III) and Tl(Ⅲ) ions in water samples. The partition coefficients ($K_p$) and the extraction percentages of 2-HNph and the ion pairs to methyl isobutyl ketone (MIBK) were obtained as basic data. After the ion pair $TBA^+$·M$(Nph)_4^-$ was formed in water samples, the analytes were concentrated by the solvent sublation and the elements were determined by GF-AAS. The pH of the sample solution, the amount of the ligand and counter ion added and stirring time were optimized for the efficient formation of the ion pair. The type and amount of optimum surfactant, bubbling time with nitrogen and the type of solvent were investigated for the solvent sublation as well. 10.0 mL of 0.1 M 2-HNph and 2.0 mL of 0.1 M $TBA^+$ were added to a 1.0 L sample solution at pH 5.0. After 2.0 mL of 0.2%(w/v) Triton X-100 was added, the ion pairs were extracted into 20.0 mL MIBK in a flotation cell by bubbling. The analytes were determined by a calibration curve method with measured absorbances in MIBK, and the recovery was 80-120%.

Ammonium Ion Binding Property of Naphtho-Crown Ethers Containing Thiazole as Sub-Cyclic Unit

  • Kim, Hong-Seok;Do, Kyung-Soon;Kim, Ki-Soo;Shim, Jun-Ho;Cha, Geun-Sig;Nam, Hak-Hyun
    • Bulletin of the Korean Chemical Society
    • /
    • v.25 no.10
    • /
    • pp.1465-1470
    • /
    • 2004
  • A short and efficient synthesis, solvent extraction and potentiometric measurements of new thiazole-containing naphtho-crown ethers are reported. The naphthalene moiety enhances the ammonium ion selectivity over potassium ion. The selectivity of ${NH_4}^+/K^+$ follows the trend $3\;{\approx}\;2\;>\;1$, indicating that the differences in conformational changes of 2 and 3 in forming ammonium complexes affect little on the resulting ammonium/potassium extraction selectivity ratio. The ammonium ion-selective electrodes were prepared with noctylphenyl ether plasticized poly(vinyl chloride) membranes containing 1-4 the effect of one naphthalene unit introduced on either right (2) or left (3) side of thiazolo-crown ether on their potentiometric properties (e.g., ammonium ion selectivity over other cations, response slopes, and detection limits) were not apparent. However, the ammonium ion selectivity of 1, 2 and 3 over other alkali metal and alkaline earth metal cations is 10-100 times higher than that of nonactin.

Ion-Pair Extraction of Boron Complex Anions (Ⅱ). Effect of Fluoride and Bifluoride Ions (붕소 착물 음이온의 이온쌍 추출 (제2보). $F^-$$HF_2^-$-이온의 영향)

  • Hyung-Soo Song;Hai-Dong Kim;Kim Kang-Jin
    • Journal of the Korean Chemical Society
    • /
    • v.27 no.6
    • /
    • pp.411-418
    • /
    • 1983
  • The effects of existing anions in hydrofluoric acid solutions, $F^-$ and $HF_2$on the extraction of methylene blue-$BF_4^-$ ion-pair into 1,2-dichloroethane have been investigated by spectrophotometry. The absorbance of the extracted ion-pair is found to be independent of $F^-$ion up to $10^{-2}$ molar concentration, which implies that $F^-$ion dose not directly interfere with the extraction. However, $HF_2^-$ ion competes with $BF_4^-$ion for methylene blue and the extraction constant for methylene blue-H$F_2$ion-pair is calculated to be 8.5 at $25^{\circ}C$.

  • PDF

Removal of Potassium from Molasses by Solvent Extraction and Ion Exchange

  • Wang, Lingyun;Nam, Sang-Ho;Lee, Manseung
    • Bulletin of the Korean Chemical Society
    • /
    • v.35 no.9
    • /
    • pp.2711-2716
    • /
    • 2014
  • The high content of potassium in molasses limits its usage as a raw material for stock feed. Moreover, its high viscosity makes it difficult to develop an efficient removal process. In this study, ion exchange and solvent extraction experiments have been performed to investigate the removal of potassium from a mixture of molasses with water. Cationic exchange resins (AG50W-X8 and Diphonix) showed a high loading percentage of potassium but the occurrence of breakthrough in few bed volumes was a drawback to the industrial application. Among the cationic extractants (D2EHPA, PC 88A, Cyanex 272) tested in this study, saponified PC 88A was found to be the best extractant for the removal of potassium. Batch simulation studies on a three stage counter current extraction confirmed that 85% of potassium was removed from 50 wt % molasses solution in water by using saponifed PC 88A.

CU+ ION EXTRACTION FROM A MODIFIED BERNAS ION SOURCE IN A METAL-ION IMPLANTER

  • Hong, In-Seok;Lee, Hwa-Ryun;Trinh, Tu Anh;Cho, Yong-Sub
    • Nuclear Engineering and Technology
    • /
    • v.41 no.5
    • /
    • pp.709-714
    • /
    • 2009
  • An ion implanter, which can serve as a metal-ion supply, has been constructed and performance tested. Copper ions are generated and extracted from a Bernas ion source with a heating crucible that provides feed gases to sustain the plasma. Sable arc plasmas can be sustained in the ion source for a crucible temperature in excess of $350^{\circ}C$. Stable extraction of the ions is possible for arc Currents less than 0.3 A. Arc currents increase with the induced power of a block cathode and the transverse field in the ion source. $Cu^+$ ions in the extracted beam are separated using a dipole magnet. A $20{\mu}A$ $Cu^+$ ion current can be extracted with a 0.2 A arc current. The ion current can support a dose of $10^{16}ions/cm^2$ over an area of $15\;cm^2$ within a few hours.

Extraction Spectrophotometric Determination of Antihistamines with Picric Acid (피크린 산에 의한 항히스타민제의 추출분광광도 정량)

  • 신태용;엄동옥
    • YAKHAK HOEJI
    • /
    • v.37 no.2
    • /
    • pp.119-123
    • /
    • 1993
  • A spectrophotomertic method is proposed for the determination of antihistamines. The method is based on solvent extraction of the ion pair formed between antihistamines and colored picric acid into chloroform. The binding state of antihistamines-picric acid complexes were presumed by IR and $^{1}$H-NMR spectra as intermolecular hydrogen bonding. This method was applicable to the determination of antihistamines in the pharamaceutical preparations.

  • PDF

Determination of Total Glycyrrhetic Acid in Glycyrrhizae Radix by Second Derivative UV Spectrometry

  • Song, Seung-Bae;Choi, Jung-Kap;Yoo, Gyurng-Soo
    • Archives of Pharmacal Research
    • /
    • v.13 no.2
    • /
    • pp.174-179
    • /
    • 1990
  • Second derivative (D2) spectrometry using ion-pair extraction technique was development for the determination of total glycyrrhetic acid (GA) in Glycyrrhizae Radix, Glycyr-rhizin (G) obtained from Glycyrrhizae Radix was hydrolyzed into GA in 2 N-HCI and methanol (1:1) and extracted from aqueous phase in the form of an ion-pair complex with tetrapentylammonium bromide (TPA) as a counter ion. Maximum D2 amplitude (Z value) was obtained when 1000-fold or greater molar ratio of TPA was used at pH 11. Reaction an effective extraction solvent of the ion-pair complex. The linearity of standard curve of ion-pair GA was obtained in the range of 4.120 $\mu$g/ml as GA. Assayed contents of GA in dry powder by D2 UV spectrometry and HPLC method were 5.31 $\pm$ 0.04% and 5.20 $\pm$ 0.008%, respectively.

  • PDF

Development of a High Brightness Ion Beam Extraction System using Micro-size Aperture (마이크로 사이즈 인출구경을 이용한 고휘도 이온빔 인출 시스템 개발)

  • Kim Yoon-Jae;Park Dong-Hee;Jeong Hyeong-Seol;Hwang Yong-Seok
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.19-23
    • /
    • 2005
  • In order to develop a high brightness ion source using plasma, the ion beam extraction system with an aperture of $100{\mu}m$ in diameter has been designed and constructed. It is observed that over 500nA of He ion beam current can be extracted. With such an optimized condition, $\~10^3\;A/cm^2sr$ beam brightness can be measured by emittance scanner, which is believed to be a promising result for developing next generation FIB.

  • PDF

Simultaneous Analysis of Semi-Volatile Organic Base/Neutral Priority Pollutants in Soil (토양 중의 비휘발성 염기/중성 유기 Priority Pollutants 동시 분석에 관한 연구)

  • Lee, Seung Seok;Park, Gyo Beom;Lee, Seok Geun
    • Journal of the Korean Chemical Society
    • /
    • v.38 no.6
    • /
    • pp.418-426
    • /
    • 1994
  • This study was aimed at the detection of 40 semi-volatile organic base/neutral compounds from soil among 129 priority pollutants listed by EPA. Two extraction procedures, sonication extraction and Soxhlet extraction, were studied as a extraction and concentration method for priority pollutants in soil. Extracts were analyted by GC/MS-SIM(selected ion monitoring). The analytical methods were tested by standard compounds spiked into blank soil. Accuracy and precision of the methods were measured by calculation of mean recovery and mean relative standard deviation. And the method detection limits were estimated.

  • PDF

Simultaneous Analysis of Semi-Volatile Organic Acid Priority Pollutants in Soil (토양 중의 비휘발성 산성 유기 Priority Pollutants 동시분석에 관한 연구)

  • Lee, Seung Seok;Park, Gyo Beom;Lee, Seong Geun
    • Journal of the Korean Chemical Society
    • /
    • v.38 no.3
    • /
    • pp.246-253
    • /
    • 1994
  • The simultaneous analysis of 11 semi-volatile organic acid compound which are listed as priority pollutants by EPA, were performed by GC/MS-SIM(selected ion monitoring). Two extraction procedures, sonication extraction and Soxhlet extraction, were studied as an extraction and concentration method for priority pollutants in soil. Accurecy and precision of the methods were measured by the calculation of mean recovery, mean relative standard deviation, and method detection limit. Finally, limitations and prospects were discussed.

  • PDF