• Title/Summary/Keyword: Ion Pair Liquid Chromatography

Search Result 20, Processing Time 0.02 seconds

Determination of Veterinary Antibiotic Residues: III. Analytical Methods_A Review (시료 중 잔류 항생제 분석 방법: III. 기기 분석 방법)

  • Kim, Chansik;Ryu, Hong-Duck;Chung, Eu Gene;Kim, Yongseok;Rhew, Doug Hee
    • Journal of Korean Society on Water Environment
    • /
    • v.32 no.6
    • /
    • pp.649-669
    • /
    • 2016
  • This study explored the analytical conditions for 21 veterinary antibiotics which have been popularly sold in South Korea in 2014 but have not yet been targeted in EPA method 1694. Most of the selected antibiotics were separated by a reverse-phase C18 column with a combination of (buffered) water and organic polar solvent, which was commonly methanol and acetonitrile in the gradient elution mode. Volatile additives such as formic acid, ammonium acetate and ammonium formate were usually added to the mobile phases to minimize asymmetrical and tailing of antibiotics' peaks and to increase their ionization in mass spectrometry. The analytical methods of aminoglycoside antibiotics were distinct from those of the other antibiotics in terms of adoption of ion-pair chromatography (IPC) and hydrophilic interaction liquid chromatography (HILIC) capable of retaining and separating extremely polar compounds due to their hydrophilicity. Trifluoroacetic acid or heptafluorobutyric acid was frequently added to the mobile phase as an ion-pair reagent for the IPC. Tandem mass spectrometry was numerously applied to the detection of antibiotics using positive electrospray ionization (ESI) and the selected reaction monitoring (SRM) mode. All reviewed analytical methods had been/were validated by evaluating recovery, limits of detection and quantification, decision limit or detection capability of the methods.

Mass Spectrometric Analysis for Discrimination of Diastereoisomers

  • Manshoor, Nurhuda;Weber, Jean-Fré
    • Mass Spectrometry Letters
    • /
    • v.6 no.4
    • /
    • pp.99-104
    • /
    • 2015
  • A liquid chromatography mass spectrometry (LC-MS) system was used to identify and distinguish oligostilbene diastereoisomers. A polyphenolic extract from Neobalanocarpus heimii known to be rich in oligostilbenes of various degrees of condensation was used as test material. Fourteen oligostilbenes were isolated from this extract on a fully automated semi-preparative HPLC system. Out of these, two pairs of dimers, one pair of trimers, two pairs of tetramers and a group of four tetramers with similar skeleton were identified as diastereoisomers. Their structures and configurations were established by spectroscopic methods. All isolated compounds were subjected to an LC-MS/MS to study their fragmentation patterns. The experiments were performed on a liquid chromatography-mass spectrometry (LC-MS) with electrospray-ionization (ESI) interface in positive mode. MS/MS spectra of each pure compound were recorded by direct infusion in identical conditions and their product ion spectra were analysed. Some subtle yet significant differences were observed between the spectra of oligostilbenes from the various diastereoisomeric series.

Analysis of Tertiary Amines and Quaternary Ammonium Salts in Electrolyte Solutions of Electrolytic Capacitors by Ion-Pair Liquid Chromatography (전해커패시터 전해액 중 3차 아민과 4차 암모늄염의 이온쌍 액체크로마토그래피에 의한 분석)

  • Chung, Yongsoon;Chang, Cheolkyu;Lee, Jeongmi;Lee, Younghoon;Kim, Seong Ho
    • Analytical Science and Technology
    • /
    • v.10 no.4
    • /
    • pp.231-239
    • /
    • 1997
  • We developed a procedure that can effectively separate and determine tertiary amines and quaternary ammonium salts in some samples with reverse phase ion-pair high performance chromatography, employing indirect spectrophotometric detection method. Detection and ion-pairing reagents used in this study were benzyl trimethylammonium chloride (BTMACl) and sodium dodecyl sulfate(DDSANa), respectively. Eluting the electrolyte solutions of some commercial electrolytic capacitors with a MeOH(40):water(60) eluent (pH 8.5 adjusted with NH4Cl-NH3 buffer) containing 0.010M DDSANa and 0.004 M BTMACl through Supelco LC-18 or ${\mu}$-Bondapak phenyl column, amines and ammonium salts contained in the sample were successfully separated and determined. Varying the composition, especially the content of quaternary ammonium salts, of electrolyte solutions based on this analysis. we could prepare the low impedance(0.08~0.13) electrolytic capacitors with excellent electrical properties and it was a confirmation that the analysis is favorable.

  • PDF

Determination of Aconitine and Related Alkaloids in Processed Buza (부자류 생약의 성분인 아코니틴과 관련 알칼로이드의 정량)

  • 엄동옥;한상욱;신현덕
    • YAKHAK HOEJI
    • /
    • v.44 no.2
    • /
    • pp.135-140
    • /
    • 2000
  • Determination of Aconitum alkaloids in processed Buza (Cho-0, Salted Buza, Moist-heating Buza, Limed Buza), which had been prepared from the raw tubers of Aconitum chiisanenseb(Ranunculaceae), was established using visible spectrophotometry and high-performance liquid chromatography (HPLC) method especially for Aconitine analysis. Aconitum alkloids were reacted with tetra- thiocy-anatocobalt[II] complex ion to form a stable ion pair. The reaction product was insoluble in water but freely soluble in several organic solvents. 1.2-Dichloroethane was the best extracting solvent among the examined solvents. Spectrophotometry of Aconitum alkaloids at nax. 625 was carried out. The HPLC method for aconitine was carried out using Radial PAK-CN column with gradient solvent system by solvent mixture of acetonitrile and phosphate buffer (pH 3.0) at 4$0^{\circ}C$ and 254 nm. Linear relationship was found between absorbance response and concentration of aconitine in range of 0.45 mM~0.9 mM ($r^2$=0.9949) by spectrophotometry and 0.3 mM~1.2mM($r^2$=0.9983) by HPLC method. These methods have been found to be suitable and reproducible for routine analysis of Aconitum alkaloids and its pharmaceutical preparations.

  • PDF

Application of extraction chromatographic techniques for separation and purification of emerging radiometals 44/47Sc and 64/67Cu

  • Vyas, Chirag K.;Park, Jeong Hoon;Yang, Seung Dae
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.2 no.2
    • /
    • pp.84-95
    • /
    • 2016
  • Considerably increasing interest in using the theranostic isotopes/ isotope pairs of radiometals like $^{44/47}Sc$ and $^{64/67}Cu$ for diagnosis and/or therapeutic applications in the nuclear medicine procedures necessitates its reliable production and supply. Separation and purification of no-carrier-added (NCA) isotopes from macro quantitates of the irradiated target matrix along with other impurities is a cardinal procedure amongst several other steps involved in its production. Multitudinous methods including but not limited to liquid-liquid (solvent) extraction, extraction chromatography (EXC), ion exchange, electrodeposition and sublimation are routinely applied either solitarily or in combination for the separation and purification of radioisotopes depending on their production routes, radioisotope of interest and impurities involved. However, application of EXC though has shown promises towards the numerous separation techniques have not received much attention as far as its application prospects in the field of nuclear medicine are concerned. Advances in the recent past for application of the EXC resins in separation and purification of the several medically important radioisotopes at ultra-high purity have shown promising behavior with respect to their operation simplicity, acidic and radiolytic stability, separation efficiencies and speedy procedures with the enhanced and excellent extraction abilities. In this mini review we will be talking about the recent developments in the application and the use of EXC techniques for the separation and purification of $^{44/47}Sc$ and $^{64/67}Cu$ for medical applications. Furthermore, we will also discuss the scientific and practical aspects of EXC in the view of separation of the NCA trace amount of radionuclides.

Analysis of Aminoglycoside Antibiotics in Meat and Cell Culture Medium Coupled with Direct Injection of an Ion-pairing Reagent (이온쌍 시약 직접 주입법을 활용한 육류 및 세포배양액 내 아미노글리코사이드계 항생제 분석)

  • Kyung-Ho Park;Song-Yi Gu;Geon-Woo Park;Jong-Jib Kim;Jong-soo Lee;Sang-Gu Kim;Sang-Yun Lee;Hyang Sook Chun
    • Journal of Food Hygiene and Safety
    • /
    • v.38 no.5
    • /
    • pp.319-331
    • /
    • 2023
  • Aminoglycoside antibiotics, also known as aminoglycosides (AGs), are veterinary drugs effective against a wide range of gram-negative and gram-positive bacteria. Owing to their recent use in cultured meats, it has become essential to establish an analytical method for safety management. AGs are highly polar compounds, and ion-pair reagents (IPRs) are used to ensure component separation. Owing to the high possibility of potential mechanical problems resulting from IPR addition to the mobile phase, an analytical method in which IPRs are added directly to the vial was explored. In this study, methods for analyzing 10 AGs via liquid chromatography-tandem mass spectrometry (LC-MS/MS) with the addition of two IPRs were validated for selectivity, detection limit, quantitation limit, recovery, and precision. The detection limit was 0.0001-0.0038 mg/kg, the quantification limit was 0.004-0.011 mg/kg, and the linearity (R2) within the concentration range of 0.01-0.5 mg/kg was over 0.99. Recovery and precision (expressed as relative standard deviation) evaluated in the two matrices (beef and cell culture media) ranged from 70.7% to 120.6% and 0.2% to 24.7%, respectively. The validated AG analytical method was then applied to 15 meats prepared from chicken, beef, and pork, and 6 culture media and additives used in cultured meat. No AGs were detected in any of the 15 meats distributed in Korea; however, streptomycin and dihydrostreptomycin were detected at levels ranging from 695.85 to 1152.71 mg/kg and 6.35 to 11.11 mg/kg, respectively, in the culture media additives. The LC-MS/MS method coupled with direct addition of IPRs to the vial can provide useful basic data for AG analysis and safety evaluation of meats as well as culture media and additives for cultured meats.

Simultaneous Determination of Water-Soluble Vitamins (Vitamin $B_1$, $B_2$, $B_3$, $B_6$ and C) in Dietary Supplements by High-Performance Liquid Chromatography (영양보충용 식품 중 수용성비타민(Vitamin $B_1$, $B_2$, $B_3$, $B_6$ and C)의 HPLC를 이용한 동시분석법)

  • Suh, Hee-Jae;Kim, So-Hee
    • The Korean Journal of Food And Nutrition
    • /
    • v.24 no.3
    • /
    • pp.414-421
    • /
    • 2011
  • 시중에 유통 중인 영양보충용 제품의 수용성 비타민 $B_1$(thiamin), $B_2$(riboflavin), $B_3$(nicotinic acid and nicotine amide), $B_6$(pyridoxine), C(ascorbic acid)의 신속한 동시분석 방법을 확립하기 위하여 본 연구를 실시하였다. 영양보충용 제품은 정제, 연질캅셀, 분말, 액상의 4가지 제형에 대해 27종의 제품을 구입한 후, Ion-pair 분리기법을 사용하여 HPLC-UVD를 이용한 동시분석 방법을 검토하였다. 비타민 $B_1$, $B_2$, $B_3$, $B_6$, C의 HPLC에 의한 동시분석 조건을 검토한 결과, 이동상은 0.02% triethylamine, 17.5% 메탄올, $5{\mu}M$ sodium hexanesulfonic acid가 함유된 pH 3.5(acetic acid로 조절)의 수용액을 사용하였고, 용출시간은 다른 피크의 영향을 받지 않도록 30분으로 하였다. 수용성 비타민의 회수율은 96% 이상이었다. 본 연구에 의해 확립된 수용성 비타민의 동시분석 조건은 검량선의 직선성, 정밀성, 정확성, 기기적합성 등이 USP 및 ICH 기준에 적합하여 HPLC의 동시분석 방법으로 합당하였다. 수용성 비타민의 추출 용매는 제형에 따라 약간의 차이를 보이긴 했으나, 물이나 산성조건을 갖춘 HPLC의 이동상이 에탄올이나 메탄올보다 높은 추출 효율을 보였다. 초음파 추출기에 의한 추출 시간은 20분이 가장 적당하였다. 본 연구의 결과는 수용성 비타민의 신속한 추출 및 분석에 매우 효율적으로 이용될 것으로 기대된다.

Qualitative and quantitative analysis of furosine in fresh and processed ginsengs

  • Li, Yali;Liu, Xiaoxu;Meng, Lulu;Wang, Yingping
    • Journal of Ginseng Research
    • /
    • v.42 no.1
    • /
    • pp.21-26
    • /
    • 2018
  • Background: Furosine (${\varepsilon}$-N-2-furoylmethyl-L-lysine, FML) is an amino acid derivative, which is considered to be an important indicator of the extent of damage (deteriorating the quality of amino acid and proteins due to a blockage of lysine and a decrease in the digestibility of proteins) during the early stages of the Maillard reaction. In addition, FML has been proven to be harmful because it is closely related to a variety of diseases such as diabetes. The qualitative analysis of FML in fresh and processed ginsengs was confirmed using HPLC-MS. Methods: An ion-pair reversed-phase LC method was used for the quantitative analysis of FML in various ginseng samples. Results: The contents of FML in the ginseng samples were 3.35-42.28 g/kg protein. The lowest value was observed in the freshly collected ginseng samples, and the highest value was found in the black ginseng concentrate. Heat treatment and honey addition significantly increased the FML content from 3.35 g/kg protein to 42.28 g/kg protein. Conclusion: These results indicate that FML is a promising indicator to estimate the heat treatment degree and honey addition level during the manufacture of ginseng products. The FML content is also an important parameter to identity the quality of ginseng products. In addition, the generation and regulation of potentially harmful Maillard reaction products-FML in ginseng processing was also investigated, providing a solid theoretical foundation and valuable reference for safe ginseng processing.

Quantitative determination of inosine 5'-monophosphate dehydrogenase activity in human peripheral blood mononuclear cells by ion-pair reversed-phase high-performance liquid chromatography (이온쌍 역상 HPLC를 이용한 인체 말초혈액단핵구에서 이노신 5'-일인산 탈수소효소 활성의 정량적 측정)

  • Shin, Hye-Jin;Kwon, Soon-Ho;Park, Ji-Myeong;Kwon, Soon-Hyo;Lee, Kyoung-Ryul;Kim, Young-Jin;Lee, Sang-Hoo
    • Analytical Science and Technology
    • /
    • v.23 no.6
    • /
    • pp.531-536
    • /
    • 2010
  • A quantitative analytical method has been established for the measurement of inosine 5'-monophosphate dehydrogenase (IMPDH) activity in human peripheral blood mononuclear cells (PBMCs) by ion-pair reversed-phase high performance liquid chromatography equipped with ultraviolet detection (HPLC/UV). IMPDH is a ${\beta}$-nicotinamide adenine dinucleotide hydrate (NAD+)-dependent dehydrogenase in which the enzyme converts inosine 5'-monophosphate (IMP) into xanthosine 5'-monophosphate (XMP). Its activity was measured by quantifying a HPLC chromatogram corresponding to XMP produced during the incubation of lysed PBMCs with IMP as a substrate and $NAD^+$ as a coenzyme. XMP produced was detected at a wavelength of 260 nm. The mobile phase was composed of a mixture of 37 mM potassium dihydrogen phosphate containing 7 mM tetra-n-butylammonium hydrogen sulfate adjusted to pH 5.5 and methanol (85:15, v/v) with a flow rate of 1 mL/min. The calibration curve was linear ($r^2$=0.999999) in the range of $0.2-50.0\;{\mu}M$ and the limit of quantification (LOQ) was $0.2\;{\mu}M$. The intra- and inter-day precisions were between 0.88-1.47% and 0.85-5.24%, respectively. The intra- and inter-day accuracies were between 98.74-99.99% and 99.95-101.65%, respectively. IMPDH activity in 11 Korean healthy volunteers ranged from 18.29 to 36.60 nmol/h/mg protein (mean = $27.70{\pm}6.28\;nmol/h/mg$ protein).

Optimization of HPLC Method and Clean-up Process for Simultaneous and Systematic Analysis of Synthetic Color Additives in Foods (식품 중 타르색소의 동시분석 및 계통분석을 위한 HPLC 분석조건 및 정제과정 확립)

  • Park, Sung-Kwan;Hong, Yeun;Jung, Yong-Hyun;Lee, Chang-Hee;Yoon, Hae-Jung;Kim, So-Hee;Lee, Jong-Ok
    • Korean Journal of Food Science and Technology
    • /
    • v.33 no.1
    • /
    • pp.33-39
    • /
    • 2001
  • To develop a method for separation process using Sep-pak $C_18$, simultaneous and systematic analysis of 8 permitted and 11 non-permitted synthetic food colors in Korea, optimization of analysis conditions for reverse phase ion-pair high performance liquid chromatography was carried out. For the best result of Sep-pak $C_18$ separation the pH of color standard mixture solution was $5{\sim}6$ and 0.1% HCl-methanol solution were set as eluent. The colors eluated from Sep-pak $C_18$ cartridge were determined and confirmed by high performance liquid chromatography with a photodiode array detector at 420 nm for yellow colors type, at 520 nm for red colors type, at 600 nm for blue and green colors type and at 254 nm for mixed colors. Conditions for HPLC analysis were as follows: column, Symmetry $C_18$ (5 m, 3.9 mm $i.d.{\times}150\;mm$); mobile phase, 0.025 M ammonium acetate (containing 0.01 M tetrabutylammonium bromide) : acetonitrile : methanol (65 : 25 : 10) and 0.025 M ammonium acetate(containing 0.01 M tetrabutylammonium bromide) : acetonitrile : methanol (40 : 50 : 10); flow rate, 1 mL/min. It takes 35 minutes for simultaneaus analysis and 18 minutes for systematic analysis. The detection limits range of each colors were $0.01{\sim}0.05\;{\mu}g/g$.

  • PDF