Acceptance Testing and Commissioning of Robotic Intensity-Modulated Radiation Therapy M6 System Equipped with InCiseTM2 Multileaf Collimator

  • Yoon, Jeongmin;Park, Kwangwoo;Kim, Jin Sung;Kim, Yong Bae;Lee, Ho
    • 한국의학물리학회지:의학물리
    • /
    • 제29권1호
    • /
    • pp.8-15
    • /
    • 2018
  • This work reports the acceptance testing and commissioning experience of the Robotic Intensity-Modulated Radiation Therapy (IMRT) M6 system with a newly released $InCise^{TM}2$ Multileaf Collimator (MLC) installed at the Yonsei Cancer Center. Acceptance testing included a mechanical interdigitation test, leaf positional accuracy, leakage check, and End-to-End (E2E) tests. Beam data measurements included tissue-phantom ratios (TPRs), off-center ratios (OCRs), output factors collected at 11 field sizes (the smallest field size was $7.6mm{\times}7.7mm$ and largest field size was $115.0mm{\times}100.1mm$ at 800 mm source-to-axis distance), and open beam profiles. The beam model was verified by checking patient-specific quality assurance (QA) in four fiducial-inserted phantoms, using 10 intracranial and extracranial patient plans. All measurements for acceptance testing satisfied manufacturing specifications. Mean leaf position offsets using the Garden Fence test were found to be $0.01{\pm}0.06mm$ and $0.07{\pm}0.05mm$ for X1 and X2 leaf banks, respectively. Maximum and average leaf leakages were 0.20% and 0.18%, respectively. E2E tests for five tracking modes showed 0.26 mm (6D Skull), 0.3 mm (Fiducial), 0.26 mm (Xsight Spine), 0.62 mm (Xsight Lung), and 0.6 mm (Synchrony). TPRs, OCRs, output factors, and open beams measured under various conditions agreed with composite data provided from the manufacturer to within 2%. Patient-specific QA results were evaluated in two ways. Point dose measurements with an ion chamber were all within the 5% absolute-dose agreement, and relative-dose measurements using an array ion chamber detector all satisfied the 3%/3 mm gamma criterion for more than 90% of the measurement points. The Robotic IMRT M6 system equipped with the $InCise^{TM}2$ MLC was proven to be accurate and reliable.

Planning and Dosimetric Study of Volumetric Modulated Arc Based Hypofractionated Stereotactic Radiotherapy for Acoustic Schwannoma - 6MV Flattening Filter Free Photon Beam

  • Swamy, Shanmugam Thirumalai;Radha, Chandrasekaran Anu;Arun, Gandhi;Kathirvel, Murugesan;Subramanian, Sai
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제16권12호
    • /
    • pp.5019-5024
    • /
    • 2015
  • Background: The purpose of this study was to assess the dosimetric and clinical feasibility of volumetric modulated arc based hypofractionated stereotactic radiotherapy (RapidArc) treatment for large acoustic schwannoma (AS >10cc). Materials and Methods: Ten AS patients were immobilized using BrainLab mask. They were subject to multimodality imaging (magnetic resonance and computed tomography) to contour target and organs at risk (brainstem and cochlea). Volumetric modulated arc therapy (VMAT) based stereotactic plans were optimized in Eclipse (V11) treatment planning system (TPS) using progressive resolution optimizer-III and final dose calculations were performed using analytical anisotropic algorithm with 1.5 mm grid resolution. All AS presented in this study were treated with VMAT based HSRT to a total dose of 25Gy in 5 fractions (5fractions/week). VMAT plan contains 2-4 non-coplanar arcs. Treatment planning was performed to achieve at least 99% of PTV volume (D99) receives 100% of prescription dose (25Gy), while dose to OAR's were kept below the tolerance limits. Dose-volume histograms (DVH) were analyzed to assess plan quality. Treatments were delivered using upgraded 6 MV un-flattened photon beam (FFF) from Clinac-iX machine. Extensive pretreatment quality assurance measurements were carried out to report on quality of delivery. Point dosimetry was performed using three different detectors, which includes CC13 ion-chamber, Exradin A14 ion-chamber and Exradin W1 plastic scintillator detector (PSD) which have measuring volume of $0.13cm^3$, $0.009cm^3$ and $0.002cm^3$ respectively. Results: Average PTV volume of AS was 11.3cc (${\pm}4.8$), and located in eloquent areas. VMAT plans provided complete PTV coverage with average conformity index of 1.06 (${\pm}0.05$). OAR's dose were kept below tolerance limit recommend by American Association of Physicist in Medicine task group-101(brainstem $V_{0.5cc}$ < 23Gy, cochlea maximum < 25Gy and Optic pathway <25Gy). PSD resulted in superior dosimetric accuracy compared with other two detectors (p=0.021 for PSD.

방사선 근접치료에 있어서 핵자기공명영상을 이용한 3차원 방사선 선량분포도의 가시화를 위한 polymer 젤의 이용 (The Use of Polymer Gel for the Visualization of 3-D Dose Distribution in Brachytherapy Using Magnetic Resonance Imaging)

  • 강해진;조삼주;정은기;강승희;오영택;전미선;권수일
    • 한국의학물리학회지:의학물리
    • /
    • 제9권4호
    • /
    • pp.207-215
    • /
    • 1998
  • 방사선의 측정방법으로 현재까지 여러 방법들이 쓰여져 왔다. 여기에는 필름을 이용하는 방법, TLD를 이용하는 방법, 전리함(ion chamber)을 이용하는 방법 등이 대체로 가장 많이 쓰여지는 방법이다. 그러나 본 연구에서는 새로운 방사선측정 방법이 시도되었다. 고분자 젤과 핵자기공명영상 (MRI)을 이용한 방법이 그 것이다. 본 연구의 목적은 방사선 측정을 위한 고분자 젤을 합성하고 합성된 젤을 사용하여 젤의 방사선 흡수선량과의 관계를 MRI 영상으로부터 구해서, 이 결과를 근접치료에 쓰이는 seed 선원의 선량분포를 측정하여 가시화 시키는데 있다. 이를 위해 지름 12 cm 원통형 팬텀에 젤을 합성하고, 이 젤을 뇌정위 방사선수술에 쓰이는 30 mm 콜리메이터를 이용하여 여러 단계의 선량을 젤에 조사하였다. 이렇게 조사된 젤은 MRI 을 촬영하였고 이렇게 촬영된 MRI 영상으로부터 젤팬텀의 각 위치의 횡이완시간 (T$_2$ time)을 영상분석 소프트웨어를 이용하여 계산하였다. 그 결과 젤의 홉수선량과 횡이완시간과는 17 Gy 근처까지는 거의 반비례 ($R^2$=0.993)하는 것을 알 수 있었으며, 이 보다 높은 흡수선량에 대해서는 또 다른 관계가 있음을 알 수 있었다. 또 이것을 이용하여 HDR afterloading system 의 Ir-192 seed 선원에 의한 선량분포와 2 mCi Ir-192 seed 선원에 의한 선량분포를 측정하였다. 그리고 이 것을 각각 치료계획컴퓨터에 의한 선량분포곡선과 비교하였다. 본 연구의 결과로는 고분자 젤을 이용한 방사선의 측정방법을 시도하여 홉수선량과 젤의 특성과의 관계를 밝혔으며, 실제로 그접치료에 쓰이는 seed 선원에 의한 선량분포 곡선을 얻는데 적용하였다.

  • PDF

Water Phantom 속 Conventional X-ray 중심축상의 깊이 선량 백분율 (Central Axis Percentage Depth-Dose in a Water Phantom Irradiated by Conventional X-rays)

  • 김원식;하석호;황선태;오장진;전재식
    • Journal of Radiation Protection and Research
    • /
    • 제12권1호
    • /
    • pp.1-11
    • /
    • 1987
  • X-선 target 으로 부터 water phantom($30{\times}30{\times}30cm^3$) 표면까지 1m이고 이 지점에서 비임 크기가 $5cm{\phi},\;10cm{\phi},\;15cm{\phi}$인 경우 phantom 표면으로 부터 X-선 중심축을 따라 깊이 2.5cm의 기준점으로 부터깊이 20cm까지 2.5cm 간격으로 깊이-선량 백분율, P(%)을 추정하였다. 사용된 X-선 인가전압 및 전류는 $150{\sim}250kV$ 및 5 mA 이었고 물속 흡수선량률, $\dot{D}_w$은 NE 2571 공동전리함의 조사선량 교정인자 $N_x$로부터 구한 공기 kerma 고정인자 $N_k$를 이용하여 결정하였다. 기준조사선량룰 $\dot{X}_c$은 Exradin A-2공동 전리함을 일본 ETL로부터 교정하여 X-선 선질을 ETL 교정선질과 같도록 반가층을 결정한 후에 측정되었다. 한편, 흡수선량 및 깊이-선량 백분율 측정의 정확도를 검증하기 위해 phantom 속 깊이 5 cm되는 교정점에서 물속흡수선량률, $\dot{D}_w$$N_k$로부터 산출한 값과 Burlin의 일반화된 공동이론을 이용하여 계산한 값을 비교해 보았으며, $N_k$로부터 결정된 깊이-선량 백분율 P(%)을 BJR Suppl. 로부터 구한 값과 비교해 본 결과는 좋은 일치를 보였다.

  • PDF

중성자, 감마선, 엑스선 방사선 측정 및 통합 제어 시스템 개발 (Development of Neutron, Gamma ray, X-ray Radiation Measurement and Integrated Control System)

  • 고태영;이주현;이승호
    • 전기전자학회논문지
    • /
    • 제21권4호
    • /
    • pp.408-411
    • /
    • 2017
  • 본 논문에서는 중성자, 감마선, 엑스선 등의 방사선을 측정하는 통합 제어 시스템을 제안한다. 제안하는 시스템은 원격 또는 네트워크상으로 측정 및 분석한 데이터를 디스플레이를 통해 모니터링 및 제어할 수 있는 장비로서, 현장에 가지 않고도 시스템 각 구성 부분의 상태를 보고 변경하여 원격으로 감시 및 관리할 수 있다. 제안하는 시스템은 감마선/엑스선 센서부, 중성자 센서부, 주제어 임베디드 시스템부, 전용 디스플레이 장치 및 GUI부, 원격 UI부 등으로 구성된다. 감마선/엑스선 센서부는 NaI(Tl) Scintillation Detector를 사용하여 저준위의 감마선 및 엑스선을 측정한다. 중성자 센서부는 Proportional Counter Detector(저준위 중성자)와 Ion Chamber Type Detector(고준위 중성자)를 사용하여 중성자를 측정한다. 주제어 임베디드 시스템부는 방사선을 검출하여 초단위로 샘플링하고 누적된 펄스 및 전류값에 대한 방사선량으로 변환한다. 전용 디스플레이 장치 및 GUI부는 방사선 측정 결과와 변환된 방사선량 및 방사능량 측정 수치를 출력하고, 사용자에게 제어 조건 설정 및 검출부에 대한 캘리브레이션 기능을 제공한다. 원격 UI부는 측정된 값들을 취합, 저장하여 원격 감시 시스템에 전달한다. 제안된 시스템의 성능을 평가하기 위하여 공인시험기관에서 실험한 결과는 중성자 검출부는 ${\pm}8.2%$ 이하의 측정 불확도가 측정되었고, 감마선, 엑스선 검출부는 7.5%이하의 불확도가 측정되어 국제 표준인 ${\pm}15%$ 이하에서 정상동작 됨이 확인되었다.

복부 일반촬영시 초점-필름간거리 변화가 피폭선량 및 화질에 미치는 영향 (Effects on Patient Exposure Dose and Image Quality by Increasing Focal Film Distance in Abdominal Radiography)

  • 김유현;권수일
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제21권1호
    • /
    • pp.52-58
    • /
    • 1998
  • We can and must improve the diagnostic images using available knowledge and technology. At the same time we must strive to reduce the patient's integral and entrance radiation dose. Reducing the integral dose to the patient during the radiologic procedure is a primary concern of the patient, especially the pediatric patient, the radiologist and the technologist. A 100cm focal film distance generally is used for most over-table radiography. The early x-ray tubes and screen film combinations required long exposures, which often resulted in motion artifacts. But nowaday, we have the generators and x-ray tubes that can deliver the energy necessary in a very short time and the receptors that can record the information just as rapidly. And, we performed this studies to evaluate the patient exposure dose and the image quality by increasing focal film distance in diagnostic radiography. There are many factors which affected to exposure factor, but we studied to verify of FFD increase, only. Effect of increasing the focal film distance to a 140 cm distance was tested as follows; 1. The focal film distances were set at 100, 120, and 140cm. 2. A 18cm acryl(tissue equivalent) phantom was placed on the table top. 3. An Capintec 192 electrometer with PM 05 ion chamber was placed at the entrance surface of the phantom, and exposure were made at each focal film distances. 4. The procedure was repeated in the same manner as above except the ion chamber was placed beneath the phantom at the film plane. 5. Exit exposure were normalize to 8mR for each portions of the experiment. Based on the success of the empirical measurements, a detailed mathematical analysis of the dose reduction was performed using the percent depth dose data. The results of this study can be summerized as followings ; 1) Increasing FFD from 100 cm to 140 cm, we would create a situation that would have a significant effect on the overall quality of radiograph and achive the 17.42% reduction of entrance dose and the 18.95% reduction of integral dose that the patient receives. 2) Thickness of Al step wedge for equal film density increased with the long distance. 3) Increasing FFD, Magnification of image was lowered. 4) Resolution of image also increased with the FFD. As the results described above, we strongly recommend using the long FFD to provide better information for our patients and profession in abdomen radiographic studies.

  • PDF

가상쐐기와 기존쐐기의 물리적 특성 비교 (Physical Characteristics Comparison of Virtual Wedge Device with Physical Wedge)

  • 조정근;최계숙;임청환;김정구;정홍량;이정옥;이만구
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제24권2호
    • /
    • pp.49-52
    • /
    • 2001
  • We compared the characteristics of Siemens virtual wedge device with physical wedges for clinical application. We investigated the characteristics of virtual and physical wedges for various wedge angles (15, 30, 45, and 60) using 6- and 15-MV photon beams. Wedge factors were measured in water using an ion chamber for various field sizes and depths. In case of virtual wedge device, as upper jaw moves during irradiation, wedge angles were estimated by accumulated doses. These measurements were performed at off-axis points perpendicular to the beam central axis in water for a $15\;cm\;{\times}\;20\;cm$ radiation field size at the depth of 10 cm. Surface doses without and with virtual or physical wedges were measured using a parallel plate ion chamber at surface. Field size was $15\;cm\;{\times}\;20\;cm$ and a polystyrene phantom was used. For various field sizes, virtual and physical wedge factors were changed by maximum 2.1% and 3.9%, respectively. For various depths, virtual and physical wedge factors were changed by maximum 1.9% and 2.9%, respectively. No major difference was found between the virtual and physical wedge angles and the difference was within 0.5. Surface dose with physical wedge was reduced by maximum 20% (x-ray beam : 6 MV, wedge angle : 45, SSD : 80 cm) relative to one with virtual wedge or without wedge. Comparison of the characteristics of Siemens virtual wedge device with physical wedges was performed. Depth dependence of virtual wedge factor was smaller than that of physical wedge factor. Virtual and physical wedge factors were nearly independent of field sizes. The accuracy of virtual and physical wedge angles was excellent. Surface dose was found to be reduced using a physical wedge.

  • PDF

차세대 리소그래피 빛샘 발생을 위한 플라스마 집속장치의 아르곤 아크 플라스마의 방출 스펙트럼 진단 (Emission spectroscopic diagnostics of argon arc Plasma in Plasma focus device for advanced lithography light source)

  • 홍영준;문민욱;이수범;오필용;송기백;홍병희;서윤호;이원주;신희명;최은하
    • 한국진공학회지
    • /
    • 제15권6호
    • /
    • pp.581-586
    • /
    • 2006
  • 차세대 리소그래피 기술인 극자외선(EUV : Extreme Ultraviolet) 빛샘 연구의 기초단계로써, 동축타입의 전극구조가 설치된 다이오드 챔버를 통해 Ar 플라스마를 생성하였으며, 방출 분광기술(emission spectroscopy)를 이용하여 방출된 가시광선 영역의 빛을 조사하였다. 장치의 입력 전압을 0.5kV씩 변화를 주어 $2\sim3.5kV$까지 인가를 했으며 이극챔버의 최적 압력인 330mTorr 일 때 각 전압에 따른 방출 분광선 데이터를 얻었다. 이때 Ar I과 Ar II 방출선을 관측하였으며 국소적인 열적평형 (LTE ; Local Thermodynamic Equilibrium) 상태의 가정 하에 볼츠만 도표(Boltzmann plot)와 사하(Saha) 방정식을 이용해 Ar I 및 Ar II의 전자온도와 이온 밀도를 각각 계산하였다. 각 입력전압에 대해 이온밀도는 Ar I과 Ar II에서 각각 $\sim10^{15}/cc$$\sim10^{13}/cc$의 값으로 계산되었다.

천장 개방형 RT 사용시설의 방사선 안전성 평가 연구 (A Study on the Evaluation of Radiation Safety in Opened-Ceiling-Facilities for Radiography Testing)

  • 허성회;박원석;허승욱;민병인
    • 한국방사선학회논문지
    • /
    • 제16권6호
    • /
    • pp.741-749
    • /
    • 2022
  • 산업체에서 용접구조물을 파괴 없이 품질을 검증하는 방사선투과검사는 압도적으로 많이 이용되지만, 방사선을 이용함에 따라 많은 안전사항이 요구된다. 방사선투과검사 작업종사자는 검사부재의 이동유무에 따라 감마선조사기인 운반용기에 내장된 Iridium-192 방사선원을 사용시설 내 혹은 사용시설 외의 장소에서 이동시켜 작업을 수행 한다. 일반적인 사용시설은 두꺼운 콘크리트로 외부와 방사선을 전면 차단한 시설이지만, 검사부재의 취급이 용이하지 않은 등의 사유로 천장이 개방된 사용시설이 있다. 일반적인 사용시설은 외부가 모두 차단되어 이론적인 선량 평가 방법을 통하여 건설하여도 무방하지만, 천장이 개방된 경우 스카이샤인효과로 인하여 단순 이론적인 계산 방법으로 방사선 안전성을 평가하는 것은 적합하지 않다. 따라서 본 연구에서는 실제 현장에서 해당 시설의 방사선 안전성을 이온챔버형 방사선측정기와 누적선량계형인 OSLD를 통하여 평가하고, 실제 평가 환경을 몬테카를로 시뮬레이션 코드인 플루카를 이용하여 모델링 및 평가를 하였다. 해당 시설에서 조사방향에 따라 시설 경계의 방사선량은 규제기관에서 정하는 기준을 만족하기 어려웠고, 추가의 방법을 통하여 방사선 안전성을 확보할 수 있었다. 또한, Iridium-192 선원을 이용한 시뮬레이션 결과가 실제 측정값과 유효한 결과임을 확인할 수 있었다.

Dual-energy 컴퓨터단층촬영에서 장비 제공선량과 측정선량 비교 (Comparison of Estimated and Measured Doses of Dual-energy Computed Tomography)

  • 김영균;김연민
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제41권5호
    • /
    • pp.405-411
    • /
    • 2018
  • We will provide basic data on the evaluation of patient dose in terms of DECT quality control by comparing the equipment-provided dose with the measured dose according to the configuration method of the X-ray generator by the manufacturer of the dual-energy CT unit. For computed tomography (CT) equipment, Discovery 750HD, Aquilion ONE GENESIS Edition, and Somatom Definition Flash were used. The $CTDI_{vol}$ value was measured by inserting the Unfors Xi ion chamber into a 32 cm PMMA acryl Phantom. The results of estimated $CTDI_{vol}$ DECT and measured $CTDI_{vol}$ showed that the dose difference between DECT 80 + 140 kVp of G company was at least 0.51% and -1.90% max, and measured $CTDI_{vol}$ was slightly lower (p<0.05). The difference of 80 + 140 kVp of S company was the minimum of 5.84% and the maximum of 7.52% (p<0.05). The measured $CTDI_{vol}$ was less than estimated $CTDI_{vol}$. The C company's 80 + 135 kVp showed a difference of at least 7.58% and a maximum of 13.58% (P<0.05), and all of measured $CTDI_{vol}$ was less. The linearity of exposure dose for all DECT equipment was very linearly reflected with $R^2$ being 0.97 or above, and the measured dose of the ionization chamber was less than the predicted dose of the monitor.