• Title/Summary/Keyword: Iodine-131

Search Result 138, Processing Time 0.027 seconds

False-positive I-131 Scan by Contaminated Muffler in a Patient with Thyroid Carcinoma (갑상선암 환자에서 방사성 옥소로 오염된 목도리에 의한 위양성 소견)

  • Seo, Han-Kyung;Kim, Min-Woo;Jeong, Hwan-Jeong;Sohn, Myung-Hee
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.40 no.1
    • /
    • pp.51-52
    • /
    • 2006
  • A 39-year-old female patient who had undergone a total thyroidectomy for a papillary thyroid carcinoma underwent a whole body scan with I-131. The I-131 scan was performed 72 hours after administering 185 MBq (5 mCi) of an I-131 solution. The anterior image of the head, neck, and upper chest showed multiple areas of increased uptake in the mediastinal area considering of functional metastasis. However, radioactivity was not evident in the image taken after removing her clothes and muffler. The image obtained after placing the muffler on the pallet showed that the radioactivity was still present. It is well known that artifacts on an I-131 scan can be produced by styling hair sputum, drooling during sleep, chewing gum, and paper or a cloth handkerchief that is contaminated with the radioactive iodine from either perspiration or saliva. This activity might be mistaken for a functional metastasis. Therefore, it is essential that an image be obtained after removing the patient's clothes. In this study, artifacts due to a contaminated muffler on the I-131 scan were found. These mimicked a functional metastasis of the mediastinal area in a patient with a papillary thyroid carcinoma.

Medical Therapeutic Effect of Hyperthyroidism - Comparison of antithyroid therapy and $^{131}I$ Therapy - (갑상선기능항진증(甲狀腺機能亢進症)의 내과적(內科的) 치료효과(治療效果) - 방사성동위원소(放射性同位元素) ($^{131}I$)치료(治療)와 항갑상선제(抗甲狀腺劑) 치료(治療)의 비교검토(比較檢討) -)

  • Lee, Kyu-Bo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.14 no.2
    • /
    • pp.35-40
    • /
    • 1980
  • In order to compare the therapeutic effect as well as side effects between antithyroid therapy and radioiodine therapy in hyperthyroidism, the author evaluated 111 cases of hyperthyroidism which were composed of 57 patients with antithyroid treatment, 23 patients with combined treatment comprising of antithyroid and radioactive iodine ($^{131}I$) and 31 patients with treatment of $^{131}I$ alone. The $^{131}I$ treatment was limited to older age, above 20 years of age, and not employed in patients with pregnancy and lactation. The patients treated with antithyroid belonged to relatively younger age, and also milder in symptoms and thyroid function tests. The remission rate of antithyroid therapy group was 97.8% within 16 months. Among them the early remission rate occured within 4 months was found to be 21.7%. The combined therapy group, having prescribed more severe cases, showed the remission rate to be 75% within 16 months. The remission rate of $^{131}I$ therapy group revealed 90.9% within 16 months. Among them the early remission rate taking place within 4 months disclosed 16.7%. The side effects of antithyroid drug, propylthiouracil, were noted as follows: itching (2.7%) skin rashes (1.3%), and adverse enlargement of goiter (10.7%). The side effects $^{131}I$ therapy were transient hypothyroidism(3.9%) permanent hypothyroidism (7.8%) and itching (2.0%).

  • PDF

Comparison of Thallium-201, Tc-99m MIBI and I-131 Scan in the Follow-up Assessment after I-131 Ablative Therapy in Differentiated Thyroid Cancer (방사성 옥소 치료 후 분화된 갑상선암 추적관찰에서 Thallium-201 스캔, Tc-99m MIBI 스캔과 I-131 스캔 검사 결과의 비교)

  • Kwon, Jae-Sung;Lee, Sung-Keun;Kim, Doe-Min;Park, Sae-Jong;Jang, Kyong-Sun;Kim, Eun-Sil;Kim, Chong-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.6
    • /
    • pp.493-501
    • /
    • 1999
  • Purpose: We conducted a comparative study to evaluate the diagnostic values of T1-201, Tc-99m MIBI and I-131 scans in the follow-up assessment after ablative I-131 therapy in differentiated thyroid cancer. Materials and Methods: The study population consisted of 20 patients who underwent surgical removal of thyroid cancer and ablative radioactive iodine therapy, and followed by one or mote times of I-131 retreatments (33 cases). In all patients, T1-201, Tc-99m MIBI, diagnostic and therapeutic I-131 scans were performed and the results were analyzed retrospectively. Also serum thyroglobulin levels were measured in all patients. The final diagnosis of recurrent or metastatic thyroid cancer was determined by clinical, biochemical, radiologic and/or biopsy findings. Results: Positive rates (PR) of Tc-99m MIBI, T1-201, diagnostic and therapeutic I-131 scans in detecting malignant thyroid tissue lesions were 70% (19/27), 54% (15/28), 35% (17/48) and 63% (30/48), respectively. The PR in the group of 20 cases (28 lesions) who underwent concomitant T1-201 and I-131 scans were in the order of therapeutic 131 scan 71%, T1-201 scan 54% and diagnostic I-131 scan 36%. There was no statistically significant difference between T1-201 and diagnostic I-131 scans (p>0.05). In the group of 20 cases (27 lesions) who underwent concomitant Tc-99m MIBI and I-131 scans, the PR were in the order of Tc-99m MIBI scan 70%, I-131 therapeutic scan 52% and I-131 diagnostic scan 33%. The PR of Tc-99m MIBI was significantly higher than that of diagnostic I-131 scan (p<0.05). Conclusion: Tc-99m MIBI scan is superior to diagnostic I-131 scan in detecting recurrent or metastatic thyroid cancer following ablation therapy in patients with differentiated thyroid cancer. T1-201 scan did not showed significantly higher positive rate than diagnostic I-131 scan. Instead of diagnostic I-131 scan before the I-131 retreatment, Tc-99m MIBI scan without discontinuing thyroid hormone replacement would be a prudent and effective approach in the management of these patients.

  • PDF

Analysis of Diffuse Hepatic Visualization after Iodine-131 Treatment in Patients with Thyroid Carcinoma (갑상선암 환자에서 전절제술 후 I-131 치료에서 미만성 간침착 정도의 분석)

  • Jung Jin-Hyung;Bae Keum-Seok;Kang Seong-Joon
    • Korean Journal of Head & Neck Oncology
    • /
    • v.16 no.2
    • /
    • pp.206-211
    • /
    • 2000
  • Objectives: Any uptake of I-131 after total thyroidectomy means the remant thyroid tissue or distant metastasis of the thyroid cancer. However diffuse hepatic uptake of I-131 without abnormal uptake was showen in many cases on I-131 whole body scan. The aim of this study was to classify the liver uptake after I-131 scan and to evaluate the analysis of this finding. Materials and Methods: Between 1982 and 1998, 104 patients(l4 males, 90 females) with normal liver function underwent I-131 scan after total thyroidectomy. Prospectively we reviewed the films of the whole body scan and analysed the correlations between results of radioiodine uptake, pathologic diagnosis, prognostic factors, lymphatic metastasis, and thyroid function test. Result: Diffuse hepatic uptake was found in 44 of 104(42%) patients. 10 of 39(26%) patients on I-131 100mCi, and 34 of 63(54%) on I-131 150mCi showed hepatic uptake. 52 of 104(50%) patients was locally invasive thyroid cancer. The rate of the hepatic uptake was no significant differences with the thyroid hormone levels(T3, Free T4) and thyroglobulin between uptake group and non-uptake group. Conclusion: The rate of I-131 uptake was high in high-dose radioiodine treatment group. However, we can not find any correlation among the thyroid functions, the extent of metastasis or the extent of local invasion. We need further study to find out the causes of the hepatic uptake of I-131 after total thyroidectomy, besides liver metabolism of I-131 attached thyroid hormones.

  • PDF

Capture of Volatile Organic Iodine Species Using Mordenites

  • Tejaswini Vaidya;John P. Stanford;Nicolene van Rooyen;Krishnan Raja;Vivek Utgikar;Piyush Sabharwall
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.21 no.2
    • /
    • pp.205-224
    • /
    • 2023
  • The emission of off-gas streams from used fuel recycling is a concern in nuclear energy usage as they contain radioactive compounds, such as, 3H, 14C, 85Kr, 131I, and 129I that can be harmful to human health and environment. Radioactive iodine, 129I, is particularly troublesome as it has a half-life of more than 15 million years and is prone to accumulate in human thyroid glands. Organic iodides are hazardous even at very low concentrations, and hence the capture of 129I is extremely important. Dynamic adsorption experiments were conducted to determine the efficiency of sodium mordenite, partially exchanged silver mordenite, and fully exchanged silver mordenite for the removal of methyl iodide present at parts per billion concentrations in a simulated off-gas stream. Kinetic analysis of the system was conducted incorporating the effects of diffusion and mass transfer. The possible reaction mechanism is postulated and the order of the reaction and the values of the rate constants were determined from the experimental data. Adsorbent characterization is performed to investigate the nature of the adsorbent before and after iodine loading. This paper will offer a comprehensive understanding of the methyl iodide behavior when in contact with the mordenites.

Effects of Antithyroid Drugs on Accidentally Internal Contamination of Iodine-131 (Iodine-131 체내오염 사고에 대한 항갑상선제의 효과)

  • Chung, In-Yong;Kim, Tae-Whan;Chin, Soo-Yil;Yun, Taik-Koo
    • Journal of radiological science and technology
    • /
    • v.11 no.1
    • /
    • pp.63-69
    • /
    • 1988
  • In case of occuring the atomic energy accidents the proper medical treatments should be necessary. As the aim of the basic data for protective actions, the present studies were carried out to evaluate the decontamination of radioiodine by the administration of the antithyroid drugs (KI, NaI) and isotonic saline. Some recommended methods of decorporating radioiodine were investigated using 450, NIH-GP mice, each injected intraperitoneally with $1{\mu}Ci$ of $NaI^{131}$ as the internal contamination and treated with 2mg/0.2ml-saline of NaI and 2.6mg/0.2ml-saline of KI as the antithyroid drugs. Accordingly, effects of antithyroid drugs for internal contamination were: 1. Administration of NaI and KI caused to rapidly excrete internal radioiodine as the antithyroid drugs and decrease in whole body retention was reduced than in the saline group. 2. After internal contamination NaI and KI were to be administered for radioprotective effects as quickly as possible. 3. Decrease in body-retention made temporary shifts with enough fluids (water), however, as far as radioprotective effects is concerned, saline was not more significant than in the other group (NaI and KI). 4. Regarding to thyroid protective effects NaI, KI and saline were significant in effectively order.

  • PDF

An Experimental Study on Airborne Contamination and Decontamination for $Na^{131}I$ Solution ($Na^{131}I$에 의(依)한 오염도(汚染度) 및 오염제거(汚染除去)의 실험적(實驗的) 연구(硏究))

  • Chu, Sung-Sil;Park, Chang-Yun
    • Journal of Radiation Protection and Research
    • /
    • v.9 no.2
    • /
    • pp.112-117
    • /
    • 1984
  • A lot of radioisotopes are applied to medical fields. It's very important to measure the activities on airborne radioiodine discharged in air from $Na^{131}I$ solutions and from patients treated with radioiodine. Also surface decontamination is another one important problem to be completly solved in the isotope laboratory where there is always the possibility of radiation contamination. The Authors measured the activities on airborne radioiodine with RI collector and scintillation counter. 1. The mean accumulative activity of airborne radioiodine discharged into air from $Na^{131}I$ solution was measured as $1.3{\times}10^{-3}/hr$ rate, and the maximum value was $1.8{\times}10^{-3}/hr$. 2. Radioactivity rate per hour of airborne iodine discharged into air from patients treated with $Na^{131}I$ was measured as $6.2{\times}10^{-5}/hr$ at 8 hour after administration of radioiodine and decreased into $2{\times}10^{-6}/hr$ after 24 hour. 3. Metalic surfaces such as stainless steel or aluminum are decontaminated 5 to 6 times more rapidly than wood and concrete surfaces. 4. Decontamination with wet wiping with detergent was 9 to 10 times more rapidly than dry wiping method, but dry wiping was useful for the first step to prevent spreading and flowing from liquid radioactive materials.

  • PDF

Charge-Transfer Complex Formation of Amines with Organic Halides (II) Complex Forming Tendency by Various Electron Acceptors (아민과 有機할로겐 化合物間의 Charge Transfer Complex 形成에 關한 硏究 (II) Electron Acceptor 에 따른 Charge Transfer Complex 形成能에 關한 硏究)

  • Kim, Yoo-Sun;Oh, Jung-Hee
    • Journal of the Korean Chemical Society
    • /
    • v.11 no.4
    • /
    • pp.126-131
    • /
    • 1967
  • Various amines (Triethylamine, Diethylamine, Dimethylaniline, Pyridine and Diphenylamine) and electron acceptors (Carbontetrachloride, iodine monochloride and iodine) were reacted in the hexane solvent system to form a charge transfer complex in each case. The tendency of forming a charge transfer complex by these electron acceptors was proportional to the basicity of amines and the different type of complex was formed as the polarity of electron donor had markedly changed, which were identified by ultraviolet spectrophotometry. A correlation between the formation of complex and the basicity of amine and the polarity of electron acceptor was discussed.

  • PDF

Studies on the Effects of Injected Amount of I131 in Uptake and Release Rate by Thyroid in Guinea Pigs 1. On the Influence of Injected Amount of Redioiodine-131 in Uptake and Release Rate by Thyroid in Male Guinea Pigs (방사성옥도(放射性沃度)(I131)의 주입량(注入量)이 기니픽 갑상선(甲狀腺)에의 섭취(攝取) 및 방출률(放出率)에 미치는 영향(影響)에 관(關)한 연구(硏究) 제(第)1보(報) 방사성옥도(放射性沃度)(I131)의 주입량(注入量)이 웅(雄)기니픽 갑상선(甲狀腺)에서의 섭취(攝取) 및 방출률(放出率)에 미치는 영향(影響))

  • Chung, Yung Chai;Shim, Sang Chil;Lee, Heung Shik
    • Korean Journal of Veterinary Research
    • /
    • v.6 no.1
    • /
    • pp.24-30
    • /
    • 1966
  • In order to observe the effect of the injected radioactive iodine-$I^{131}$ on the uptake in thyroid of normal male guinea pigs and P.B.$I^{131}$ conversion ratio of $I^{131}$ in serum, 24 matured male guinea pigs were divided in 4 groups and $35{\mu}c$, $70{\mu}c$, $140{\mu}c$ and $280{\mu}c$ per kg of body weight respectively were injected subcutaneously. 1. The uptake rates of radioactveiodine-$I^{131}$ by external counts of thyroidal uptake reached the maximum level of uptake in 24 hours after injection. 2. As the injected amount increases, the uptake rates of maximum levels and release rate were increased. 3. Uptake rate in the removed thyroid have shown no statistical in the $35{\mu}c$ and $70{\mu}c$ groups of injected guinea pigs. 4. There was no statistical significance in $140{\mu}c$ and $280{\mu}c$ groups of injected guinea pigs. 5. P.B.$I^{131}$ conversion ratio of $I^{131}$ in serum was not in proportion to injected amounts: 61.0%(35), 70.2%(70), 75.3%(140) and 64.8%(280).

  • PDF

Indigenous Radiosynthesis of [131I]Iodobenzylguanidine ([131I]mIBG) for Neuroblastoma Imaging

  • Nadeem Ahmed Lodhi;Muhammad Irfan;Muhammad Nasir Saddique;Kahkshan Bashir Mir;Naseer Ahmed;Shazia Fatima;Mumtaz Khan;Muhammad Wasim;Samina Roohi
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.8 no.2
    • /
    • pp.71-76
    • /
    • 2022
  • Indigenous diagnostic dose of 131I-labeled meta-iodobenzylguanidine ([131I]mIBG) was prepared via Cu+ catalyzed isotope exchange reaction generated in situ by sodium metabisulfite for imaging of neuroblastoma tumor. [131I]mIBG was produced in overall 85-90% radiochemical yield. The average amount of radioactivity of [131I]mIBG was 2164 MBq (1998-2331MBq) with an average specific activity > 1000 MBq/mg at the end of synthesis. The radiochemical purity was ≥ 99.9% after purification through Dowex-1 × 8 ion exchange resin (100-150 mesh) at the date of preparation. The stability of [131I]mIBG at concentration 480-555 MBq/mL was > 97% at 4 ℃ after 4 days. The room temperature (25 ℃) stability of [131I]mIBG was > 98% after 24 h. Biodistribution of [131I]mIBG in patient showed uptake in salivary glands, liver, spleen and excreted though urinary bladder. Neuroendocrine medicated uptake into tumor lesion and metastatic sites were noted which strongly correlate with the morphological abnormalities of patient.