• Title/Summary/Keyword: Inverter noise

Search Result 254, Processing Time 0.031 seconds

Study of PI and SI using Current Source of Inverter (Inverter의 Current Source를 이용한 전원 및 신호 무결성에 관한 연구)

  • Baek, E-Rang;Park, Mun-Hwan;Kim, Jong-Min;Lee, June-Sang;Nah, Wan-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.41-42
    • /
    • 2011
  • 전원부의 Current에 Inductance적으로 유도되어 추가된 Voltage Noise를 측정할 때, 기존의 측정방법에서는 IBIS 1개만을 측정에 사용하기 때문에 Output Current의 정확한 값을 측정하지 못하였다. High Frequency를 사용하는 Device가 증가하고 이에 따른 SI의 정확한 검증에 대한 필요성이 커짐에 따라, 본 연구에서는 Switching Current Source로 Inverter를 사용하여 신뢰할 수 있는 모델을 구현하고 이를 검증한다.

  • PDF

Modeling of a novel power control scheme for Photovoltaic solar system

  • Park, Sung-Joon
    • Journal of information and communication convergence engineering
    • /
    • v.6 no.4
    • /
    • pp.417-420
    • /
    • 2008
  • Solar electric systems have very little impact on environment, making them one of the cleanest power-generating technologies available. While they are operating, PV systems produce no air pollution, hazardous waste, or noise, and they require no transportable fuels. In PV system design, the selection and proper installation of appropriately-sized components directly affect system reliability, lifetime, and initial cost. In this research, we have studied the PWM(Pulse Width Modulation) signals. I proposed an efficient photovoltaic power interface circuit incorporated with a DC-DC converter and a sine-pwm control method full-bridge inverter. In grid-connected solar power systems, the DC-DC converter operates at high switching frequency to make the output current a sine wave, whereas the full-bridge inverter operates at low switching frequency which is determined by the ac frequency. Thus, it can reduce the switching losses incurred by the full-bridge inverter. Full-bridge converter is controlled by using microprocessor control method, and its operation is verified through computer aided simulations.

A Inverter Design of Reversible Power Converter (가역 전력변환기의 인버터 설계)

  • Chun, J.H.;Lee, H.W.;Baek, S.H.;Kwak, D.K.
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.8-13
    • /
    • 2005
  • In this paper discusses single-phase DC-AC Inverter design of reversible power converter that driven by binary combination at different transformer winding ratio by BCD code level. It has a advantage that constructs a control system simply and obtain load current of good quality without filter circuit and free from noise or isolation for lower switching frequency. In this research, study on current type converter and inverter circuit that consist for possibility of AC-DC/DC-AC multi-level reversible converter.

  • PDF

Study of harmonic reduction method in PWM Inverter of washing machine BLDC motor that use single current sensor (단일 전류 감지기를 이용한 세탁기 BLDC 모터의 PWM Inverter 에서 고조파 저감방법에 관한 연구)

  • Kim, Hwa-Sung;Yoo, Ji-Yoon
    • Proceedings of the KIPE Conference
    • /
    • 2007.11a
    • /
    • pp.142-144
    • /
    • 2007
  • This paper proposes problem improvement in existing method about three-phase current reconstruction method and present minimum voltage injection method and Smooth voltage injection method in single current sensor for washing machine motor drive. So, presented wash noise improvement method through ripple reduction in inverter. The simulation and experimental results are given to show the effectiveness of the proposed method for reconstructing the phase currents and reducing the noises.

  • PDF

Study on the Parallel Resonant Inverter of an High Frequency Induction Heating System which the Frequency Tracking and the Power Regulation is possible (주파수 추종과 정전력 제어가 가능한 고주파 유도가열기의 병렬 공진형 인버터에 대한 연구)

  • 김남수;김태언;김승철;임영도
    • Proceedings of the IEEK Conference
    • /
    • 2002.06e
    • /
    • pp.63-66
    • /
    • 2002
  • This paper has been studied the parallel resonant inverter which controlling the constant power and tracking the load resonant frequency with PLL is possible, in order to minimize switching losses. The current-fed full-bridge type parallel resonant inverter of an induction heating system was composed of IGBT in switching device. For regulating the output power of an induction heating system, the Fuzzy controller is used. The Fuzzy controller makes the control signal for a stable power regulating control and when reference is changed, it is superior to adaptability. It has been evaluated a stable behavior for a noise with switching and a load disturbance.

  • PDF

A Study on the LCC-HB Type Resonant Inverter Using ZVS (ZVS를 이용한 LCC형 하프.브릿지 고주파 공진 인버터에 관한 연구)

  • Kim, Jong-Hae;Lee, Yeung-Sik;Seo, Chul-Sik;Kim, Dong-Hee;Oh, Seung-Hun;Ahn, Hang-Mok
    • Proceedings of the KIEE Conference
    • /
    • 1998.07f
    • /
    • pp.1863-1865
    • /
    • 1998
  • A class-D zero voltage switching (called soft-switching) inverter with only one capacitor in parallel with both FET, along with an approximate analysis and experimental results, is introduced. The inverter offers both zero turn-on and zero turn-off switching losses, yielding high efficiency at high frequencies. In addition, soft switching reduces switching noise associated with the high frequency ringing at the swithching instants.

  • PDF

Soft Switching Inverter with An Auxiliary Active Quasi-Resonant DC Link Snubber for AC Servo Motor Drive

  • Mun, Sang-Pil;Kim, Chil-Ryong;Lee, Jong-Kurl;Park, Man-Kyu;Kwon, Soon-Kurl
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.3
    • /
    • pp.79-87
    • /
    • 2008
  • This paper presents a simple circuit topology of the auxiliary active quasi-resonant DC link snubber-assisted three phase voltage source soft-switching inverter for small scale PM motor drive applications. The pulse processing drive circuit interface and its soft-switching operation are discussed from an experimental point of view. Moreover, its conductive noise is measured and evaluated for electrical AC servo motor drive as compared with that of the conventional hard switching inverter.

A study on the high frequency resonant inverter for sealing wax using a leaks (누설자속을 이용한 sealing-wax용 고주파 공진 인버터에 관한 연구)

  • Won, J.S.;Kim, D.H.;Noh, C.K.;Min, B.J.;Kim, K.S.;Jung, S.K.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.1165-1167
    • /
    • 2000
  • This paper describes a current fed high frequency resonant inverter used as the power supply for sealing-wax. The proposed inverter can reduce switching losses, noise and voltage stress at turn-on and turn-off. The analysis of proposed circuit uses normalized parameter and characteristic estimation which is needed in each step before design is generally described according to normalized frequency ($\mu$), coefficient of coupling($\kappa$) and all parameters. The theoretical analysis is proved through experiment and this circuit shows that it can be used practically as the power supply system for sealing wax and DC-DC converter.

  • PDF

The Analysis for the Characteristics of Switching Surge of Adjustable Speed Drive by Inverter (인버터에 의한 가변속 구동장치의 스위칭 써지 특성 분석)

  • Song, Seung-Youp;Kim, Jae-Chul;Lee, Do-Hoon;Sin, Jung-Eun;Im, Tae-Hoon
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.241-243
    • /
    • 2003
  • By development of power electronics technology, the increasing of inverter's switching frequency lead to the development of speed control technology of induction motor. But the surge voltage including harmonic component in output waveform can cause the motor to generate power losses, torque ripple, acoustic noise and oscillation. This paper is analyzed the characteristics for switching surge of adjustable speed drive and is presented the problem by inverter.

  • PDF

The Suppression of both Leakage-current and Surge voltage occuring Variable-speed AC Drives (가변속 AC 드라이브 시스템에 발생하는 누설전류와 서지전압의 억제)

  • Park Jin-Min;Lee Hyun-Woo;Kim Young-Mun;Mun Sang-Phil;Suh Ki-Young
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.1232-1234
    • /
    • 2004
  • In this paper, we represent both occurrence reason of Surge-voltage and Leakage current of AC drive system which is operated by Voltage-type PWM Inverter. It generates a compensating voltage which has the same amplitude as, but the opposite phase to, the common-mode voltage produced by the PWM inverter. The compensating voltage is superimposed on the inverter output by a common-mode transformer. As a result, the common-mode voltage applied to the load is canceled completely. The design method of the active common-mode noise canceler is also presented in detail. Therefore, we try to describe the method controling both of them and all of the proprieties are proved by our experiment.

  • PDF