Study and Control of Photovoltaic Water Pumping System

  • Khlifi, Mohamed Arbi
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.1
    • /
    • pp.117-124
    • /
    • 2016
  • Solar photovoltaic pumping system is one of most important of renewable energy applications especially in rural areas. Besides, the control strategy for standalone solar pumping system based on induction motor and without DC/DC converter has been widely studied and discussed in the literature. This topology is of great concern due its economic issues, especially when a standard frequency converter (SFCs) with scalar control is used instead of a dedicated PV inverter. This paper proposes an external control module to generate SFCs frequency reference in order to ensure both maximum power point tracking (MPPT). We present method of modeling and control of photovoltaic pumping system based centrifugal pump controlled by new improved incremental conductance in order to optimize the price and operation of pumping system this MPPT algorithm have many advantages like can be eliminate proportional integral controller It is a low cost solution since it requires no additional power equipment. The induction motor driven pump that is powered by a solar array is controlled by the indirect field oriented control (IFOC). The effectiveness of the proposed approach is illustrated by simulations carried out under Matlab Software. The experimental results are compared with simulation results.

An Efficient FPGA based Real-Time Implementation Shunt Active Power Filter for Current Harmonic Elimination and Reactive Power Compensation

  • Charles, S.;Vivekanandan, C.
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.4
    • /
    • pp.1655-1666
    • /
    • 2015
  • This paper proposes a new approach of Field Programmable Gate Array (FPGA) controlled digital implementation of shunt active power filter (SAPF) under steady state and dynamic operations. Typical implementations of SAPF uses microprocessor and digital signal processor (DSP) but it limited for complex algorithm structure, absence of feedback loop delays and their cost can be exceed the benefit they bring. In this paper, the hardware resources of an FPGA are configured and implemented in order to overcome conventional microcontroller or digital signal processor implementations. This proposed FPGA digital implementation scheme has very less execution time and boosts the overall performance of the system. The FPGA controller integrates the entire control algorithm of an SAPF, including synchronous reference frame transformation, phase locked loop, low pass filter and inverter current controller etc. All these required algorithms are implemented with a single all-on chip FPGA module which provides freedom to reconfigure for any other applications. The entire algorithm is coded, processed and simulated using Xilinx 12.1 ISE suite to estimate the advantages of the proposed system. The coded algorithm is also defused on a single all-on-chip Xilinx Spartan 3A DSP-XC3SD1800 laboratory prototype and experimental results thus obtained match with simulated counterparts under the dynamic state and steady state operating conditions.

Test Results Grid Connection of 120 kW Power Generation System (120 kW급 태양광 발전시스템 설치 및 실 계통연계 운전 결과 평가)

  • Hwang, Jung-Hee;Ahn, Kyo-Sang;Lim, Hee-Cheon;Kim, Su-Chang;Kim, Sin-Sub
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.17 no.3
    • /
    • pp.338-346
    • /
    • 2006
  • In this paper, the test results of medium-size(120 kW class) PV system which was installed in the Taeahn thermal power station of Korea Western Power Co., Ltd., were summarized for developing the practical technology to applicate high voltage grid connection PV system. The 120 kW photovoltaic system which was consisted of 1,300 modules, PCS, and 150 kVA transformer station has been operated since Aug. 05, 2005. For verifying the modeling results of PV system, the operation data was compared with modeling results which was executed commercial PSCAD/EMTD and Psim tools. An equivalent circuit model of a solar cell has been also used for solar array modeling. A series of parameters required for array modeling have been estimated from general specification data of a solar module. A PWM voltage source inverter(VIS) and its current control scheme have been analyzed by using P&O (perturbation and Observation) MPPT algorithms technique.

Comparative Study between Two and Single-loop Control of Boost Converter for PVPCS (태양광용 부스트 컨버터의 2중 루프 제어 및 단일 루프 제어의 특성 비교)

  • Kim, Dong-Whan;Im, Ji-Hoon;Song, Seung-Ho;Choi, Ju-Yeop;An, Jin-Ung;Lee, Sang-Chul;Lee, Dong-Ha
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2012.03a
    • /
    • pp.153-159
    • /
    • 2012
  • In photovoltaic system, the characteristic of photovoltaic module such as open circuit voltage and short circuit current will be changed because of cell temperature and solar radiation. Therefore, a boost converter of the PV system connects between the output of photovoltaic system and DC link capacitor of grid connected inverter as controlling duty ratio for maximum power point tracking(MPPT). This paper shows the dynamic characteristic of the boost converter by comparing single-loop control algorithm and two-loop control algorithm using both analog and digital control. The proposed both compensation method has been verified with computer simulation and simulation results obtained demonstrate the validity of the proposed control schemes.

  • PDF

Development of Test Method for Flat Panel Display Life Time Prediction during Atmospheric Particle Exposure (평판디스플레이의 대기중 분진농도에 따른 수명예측 시험방법 개발)

  • Yoo, Dong-Hyun;Lee, Gun-Ho;Choi, Jung-Uk;Ahn, Kang-Ho
    • Journal of the Semiconductor & Display Technology
    • /
    • v.12 no.4
    • /
    • pp.45-48
    • /
    • 2013
  • The electronic device, such as flat panel display (FPD), is very important in our life as a means of communication between humans. Liquid crystal display (LCD), which is categorized as a flat panel display, has been used in many display products, especially in TV industry. An LED TV is composed of several electrical components, such as liquid critical module (LCM), analog to digital convertor (AD), power supplier, and inverter board. These modules are very vulnerable to particulate contamination, and causing malfunction or visibility degradation. In this study, we developed a test method for prediction of LCM's lifetime. The test system consists of carbon particle generation flame, dilution system, test chamber, and particle concentration monitoring instrument. Since the carbon particles are the most abundant in the atmosphere and easily absorb light, soot particles are used as a challenging material for this test. The concentration of generated soot particles is set around 4,000,000 #/cc, which is 400 times higher than that of usual atmospheric particles. Through this experiment, we deduced the relationship between the dust concentration and life time of the test specimen.

Development of 6kW ZVS Boost Converter by 4-Parallel Operation (4-병렬 제어 기법을 적용한 6kW 영전압 스위칭 승압형 컨버터 개발)

  • Rho, Min-Sik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.1
    • /
    • pp.86-92
    • /
    • 2009
  • This paper presents development of 6kw ZVS(Zero Voltage Switching) boost converter by 4-parallel operation. To realize a high capacity converter with 6 kw, 4-parallel operation of 1.5kW unit module is proposed in this paper. To meet high ratio input to output voltage, isolated type booster converter is designed. To achieve ZVS operation of 4-switches of full bridge and protect a voltage overshoot caused by switch turn-off, simple active-clamp circuit is applied to the primary side. For parallel operation of 4-modules, master-slave control method is proposed to achieve input current sharing of 4-unit converter modules accurately. For performance tests, simulation is carried out. Also, load and experimental tests of the developed booster converter, 230Vdc/6kW, are carried out under various conditions. For field tests, the developed converter is applied for boosting a battery power to high DC_link voltage for a VSI inverter which starts a micro-turbine(MT) installed in vehicle and it's performance is verified through high speed motoring a MT up to tens of thousands of rpm.

Development of Few-second 40 kV, 280 kW High Voltage Pulse Power Supply (수 초 지속 40 kV, 280 kW 고전압 펄스전원장치 개발)

  • Kim, S.C.;Nam, S.H.;Heo, H.;Heo, H.;Moon, C.;Kim, J.H.;Oh, S.S.;Yang, J.W.;Sho, J.H.
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.990-991
    • /
    • 2015
  • To drive a magnetron injection gun, thsi paper decribes a design, fabrication and analysis results of proposed compact capacitor charging power supply (CCPS) formed resonant full-bridge inverter for electron gun power supply (EGPS). EGPS needs the -40 kV output voltage and 280 kW output power for few seconds continuously and have to be designed for the rise and fall time to be less than 1 ms with the ripple stability of output voltage of lower than 1%. In order to meet the requirements, we used eight resonant full-bridge modules operated in parallel. Each resonant full-bridge module can supply the current of 0.9 A and the voltage of 40 kV, and is operated by N-phase shift switching pattern. In this paper, we present the design, simulation and test results of interleaved CCPS.

  • PDF

A Study on the Development of High-Speed Control Algorithm for the trapezoidal Brushless DC Motor (구형파 브러시리스 직류 전동기의 고속 운전 제어 알고리즘 개발에 관한 연구)

  • Choi Jae-Hyuk;Jang Hoon;Kim Jong-Sun;Yoo Ji-Yoon;Song Myung-Hyun;Lee Young-Sun
    • Proceedings of the KIPE Conference
    • /
    • 2002.07a
    • /
    • pp.435-438
    • /
    • 2002
  • The Objects of this paper are developing and also improving a high-speed driving system of bushless DC motor(BLDCM) with economical and practical performance. Because BLDC motors are manufactured that each motor can create proper torque for their individual purpose, it is difficult to increase over the rated speed when a motor speed (with it's rated road) is reaching to a maximum speed so the motor torque cannot be increased. This paper verifies the effects of Leading Angle Algorithm, that is proposed on this paper, with examining existing methods to maximize the torque of a motor in high-speed driving area. The arithmetic processor for this experiment is TMS320C240 DSP controller that is designed for a special purpose of motor control in Texis Instrument Inc., and the used Inverter is PM10CSJ060, a Intelligent Power Module of Mitsubishi Corporation.

  • PDF

Development of PSCAD/EMTDC Inverter Module for Simulating Grid-connect Wind Energy Conversion System (풍력발전 계통연계 모의를 위한 PSCAD/EMTDC 인버터 모듈 개발)

  • Kim, Seul-Ki;Kim, Eung-Sang;Park, Min-Won;Kim, Ji-Won;Jeon, Jin-Hong;Kim, Tae-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2002.04a
    • /
    • pp.204-206
    • /
    • 2002
  • 계통연계 풍력발전시스템의 특성을 고찰하기 위해서는 블레이드, wind turbine, 정류기, 인버터 등의 풍력발전시스템의 각 구성요소의 모델링과 적절한 제어 알고리즘에 대한 모의가 요구된다. 본 연구에서는 동기발전기를 풍력발전기로 사용하고 있는 계통연계형 풍력발전시스템의 출력 및 동특성을 모의하기 위한 전류제어형 전압원인버터의 PSCAD/EMTDC 모듈을 제시한다. 풍속의 가변특성에 의해 동기발전기에 들어오는 입력은 변하게 되고, 동기발전기가 동기주파수를 유지할 수 있도록 인버터에서는 이러한 입력과 동일한 출력을 낼 수 있어야 하며, 동시에 계통에서 허용하는 일정 전압과 계통주파수와 동일한 주파수를 갖는 출력을 공급해야 한다. 본 논문에서는 이를 위해 동기발전기의 주파수를 제어하는 전류제어형 전압원인버터 모듈을 소개한다. 모의를 통해 결과를 검증한다.

  • PDF

A Study on the Unit Type BIPV Design Method for Super-Tall Building Concentrating on the Solar Irradiance Incident on the Building Facades (수직면 일사량을 고려한 초고층 건축물 적용 Unit형 BIPV 설계 방안에 관한 연구)

  • Liu, Chun-De;Seo, Young-Seok;Oh, Min-Seok;Kim, Hway-Suh
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.370-375
    • /
    • 2011
  • BIPV시스템 분야는 다른 PV 적용 기술 분야에 비해 빠르게 성장하고 있으나 소형 건축물 위주로 적용되었으며, 초고층 건축물과 같이 수직적으로 높은 건축물의 외부환경조건에 대응하기 위한 BIPV의 적용 방안은 현재까지 연구되어지지 않았다. 국내의 경우 선진국에 비해 초고층 건축물에 대한 BIPV시스템 적용기술은 아직 초기 연구단계에 불과하다. 초고층 건축물의 고유의 특징을 고려하여 초고층 건축물 파사드에 입사하는 일사량의 분포가 균일하지 않을 것이라고 예측하고 실측을 진행하였으며, 실측 결과의 분석을 통하여 초고층 건축물에서의 BIPV시스템 최적 설계방안을 제시하였다. 결론적으로 본 연구에서는 초고층 건축물의 외벽에 입사하는 일사량을 고려한 Unit형 BIPV설계 방안을 제시하였으며, 특히, 측정된 일사량 데이터를 활용하여 초고층 건축물에 적합한 인버터의 선정의 대안을 제시하였다.

  • PDF