• 제목/요약/키워드: Inverter module

검색결과 242건 처리시간 0.023초

Differential Power Processing System for the Capacitor Voltage Balancing of Cost-effective Photovoltaic Multi-level Inverters

  • Jeon, Young-Tae;Kim, Kyoung-Tak;Park, Joung-Hu
    • Journal of Power Electronics
    • /
    • 제17권4호
    • /
    • pp.1037-1047
    • /
    • 2017
  • The Differential Power Processing (DPP) converter is a promising multi-module photovoltaic inverter architecture recently proposed for photovoltaic systems. In this paper, a DPP converter architecture, in which each PV-panel has its own DPP converter in shunt, performs distributed maximum power point tracking (DMPPT) control. It maintains a high energy conversion efficiency, even under partial shading conditions. The system architecture only deals with the power differences among the PV panels, which reduces the power capacity of the converters. Therefore, the DPP systems can easily overcome the conventional disadvantages of PCS such as centralized, string, and module integrated converter (MIC) topologies. Among the various types of the DPP systems, the feed-forward method has been selected for both its voltage balancing and power transfer to a modified H-bridge inverter that needs charge balancing of the input capacitors. The modified H-bridge multi-level inverter had some advantages such as a low part count and cost competitiveness when compared to conventional multi-level inverters. Therefore, it is frequently used in photovoltaic (PV) power conditioning system (PCS). However, its simplified switching network draws input current asymmetrically. Therefore, input capacitors in series suffer from a problem due to a charge imbalance. This paper validates the operating principle and feasibility of the proposed topology through the simulation and experimental results. They show that the input-capacitor voltages maintain the voltage balance with the PV MPPT control operating with a 140-W hardware prototype.

고주파 공진형 인버터를 이용한 유도가열형 2단 히터 (Development a Two Step Heater Using Induction Heating Based on o High Frequency Resonant Inverter)

  • 신대철;권혁민
    • 조명전기설비학회논문지
    • /
    • 제19권7호
    • /
    • pp.81-86
    • /
    • 2005
  • 제안한 유도가열 시스템은 증류탑 장치에 사용되는 특수충진체에 의한 열교환기술과 IH(Induction-Heating) 전자유도가열용의 특수한 고주파 전력회로 기술을 응용한 차세대 가열방식이다. 특히 일체의 연소과정이 없다는 점에서 작업환경의 개선이 가능하며 본 기술은 IGBT 대응의 고주파 인버터를 사용하여 상용교류로부터 수[kHz]의 고주파교류(HFAC)를 발생시킬 수 있다. 본 논문에서는 1.5[kW]급 하프-브릿지 공진형 인버터 시스템과 공진부하의 동작해석, 특성분석 및 본 시스템을 이용한 2단가열 과열증기 발생장치의 개발과 시스템의 응용에 대해 논하였다.

5[kW]급 풀-브릿지 고주파 공진형 인버터를 이용한 고효율 유도가열 히터 개발 (Development a High-Efficiency Induction Heating Heater using a 5[kW] Class Full-Bridge High Frequency Resonant Inverter)

  • 권혁민;신대철
    • 전력전자학회논문지
    • /
    • 제10권5호
    • /
    • pp.481-487
    • /
    • 2005
  • 제안한 유도가열 시스템은 증류탑 장치에 사용되는 특수충진체에 의한 열교환기술과 IH(Induction-Heating)전자유도가열용의 특수한 고주파 전력회로 기술을 응용한 차세대 가열방식이다. 특히 일체의 연소과정이 없다는 점에서 작업환경의 개선이 가능하며 본 기술은 IGBT대응의 고주파 인버터를 사용하여 상용교류로부터 수[kHz]의 고주파 교류를 발생시킬 수 있다. 본 논문에서는 절연체 용기 내에 특수 스텐레스 발열체부하를 수납하여 용기 외부의 고주파 공진형 인버터 접속의 워킹코일로부터 비접촉 상태로 전자유도 와전류를 구조체에 흘림으로서 발열하게 되는 새로운 유체가열방식을 제안한다. 그리고 5[kW]급 풀-브릿지 공진형 인버터 시스템과 공진부하의 동작해석, 특성분석 및 본 시스템을 이용한 고효율 스팀 발생장치의 개발과 시스템의 응용에 대해 논하였다.

공진형 인버터를 이용한 2단 유도가열 시스템의 주파수제어에 관한 연구 (A Study on the Frequency Control on the Induction Heating System Using Two Step Resonant Inverter)

  • 유재훈;신대철
    • 조명전기설비학회논문지
    • /
    • 제22권1호
    • /
    • pp.95-103
    • /
    • 2008
  • 제안한 유도가열 시스템은 증류탑 장치에 사용되는 특수충진체에 의한 열교환기술과 IH(Induction-Heating) 전자유도가열용의 특수한 고주파 전력회로 기술을 응용한 차세대 가열방식이다. 특히 일체의 연소과정이 없다는 점에서 작업환경의 개선이 가능하며 본 기술은 IGBT대응의 고주파 인버터를 사용하여 상용교류로부터 수[kHz]의 고주파교류(HFAC)를 발생시킬 수 있다. 본 논문에서는 1.5[kW]급 하프-브릿지 공진형 인버터 시스템과 공진부하의 동작해석, 특성분석 및 본 시스템을 이용한 2단 가열 과열증기 발생장치의 개발과 시스템의 응용에 대해 논하였다.

The New Smart Power Modules for up to 1kW Motor Drive Application

  • Kwon, Tae-Sung;Yong, Sung-Il
    • Journal of Power Electronics
    • /
    • 제9권3호
    • /
    • pp.464-471
    • /
    • 2009
  • This paper introduces a new Motion-$SPM^{TM}$ (Smart Power Modules) module in Single In-line Package (SIP), which is a fully optimized intelligent integrated IGBT inverter module for up to 1kW low power motor drive applications. This module offers a sophisticated, integrated solution and tremendous design flexibility. It also takes advantage of pliability for the arrangement of heat-sink due to two types of lead forms. It comes to be realized by employing non-punch-through (NPT) IGBT with a fast recovery diode and highly integrated building block, which features built-in HVICs and a gate driver that offers more simplicity and compactness leading to reduced costs and high reliability of the entire system. This module also provides technical advantages such as the optimized cost effective thermal performances through IMS (Insulated Metal Substrate), the high latch immunity. This paper provides an overall description of the Motion-$SPM^{TM}$ in SIP as well as actual application issues such as electrical characteristics, thermal performance, circuit configurations and power ratings.

순시전압강하 보상 기능을 가지는 무정전전원공급장치의 개발 (Development of Uninterruptible Power Supply with Voltage Sag Restorer Function)

  • 박종찬;손진근
    • 전기학회논문지P
    • /
    • 제63권2호
    • /
    • pp.95-101
    • /
    • 2014
  • In this paper, UPS, with a built-in instantaneous sag drop compensation features, was developed to improve performance. The improved UPS, using instantaneous moving average method, compensates by quickly measuring the voltage and series inverter of half-bridge type, using line-interactive method that links with the voltage of the battery and power source, was developed. In addition, by developing a parallel inverter that uses a high-efficiency PWM switching method, overall UPS system was enhanced. To verify the performance of the proposed algorithm, single-phase 5[kVA] UPS systems were designed and the experimental system was constructed. The low-cost type of Cortex-M3 module CPU STM32F103R8T6 (32[bit]) is attached and the switching time of mode transfer was set within 4 [ms]. THD of the linear load operates in less than 3[%], and the stability of the output voltage operates in approximately ${\pm}2[%]$ range. The superior performance of the operations was confirmed with the system set as above.

An Improved SPWM Strategy to Reduce Switching in Cascaded Multilevel Inverters

  • Dong, Xiucheng;Yu, Xiaomei;Yuan, Zhiwen;Xia, Yankun;Li, Yu
    • Journal of Power Electronics
    • /
    • 제16권2호
    • /
    • pp.490-497
    • /
    • 2016
  • The analysis of the switch status of each unit module of a cascaded multi-level inverter reveals that the working condition of the switch of a chopper arm causes unnecessary switching under the conventional unipolar sinusoidal pulse width modulation (SPWM). With an increase in the number of cascaded multilevel inverters, the superposition of unnecessary switching gradually occurs. In this work, we propose an improved SPWM strategy to reduce switching in cascaded multilevel inverters. Specifically, we analyze the switch state of the switch tube of a chopper arm of an H-bridge unit. The redundant switch is then removed, thereby reducing the switching frequency. Unlike the conventional unipolar SPWM technique, the improved SPWM method greatly reduces switching without altering the output quality of inverters. The conventional unipolar SPWM technique and the proposed method are applied to a five-level inverter. Simulation results show the superiority of the proposed strategy. Finally, a prototype is built in the laboratory. Experimental results verify the correctness of the proposed modulation strategy.

Phase Angle Control in Resonant Inverters with Pulse Phase Modulation

  • Ye, Zhongming;Jain, Praveen;Sen, Paresh
    • Journal of Power Electronics
    • /
    • 제8권4호
    • /
    • pp.332-344
    • /
    • 2008
  • High frequency AC (HFAC) power distribution systems delivering power through a high frequency AC link with sinusoidal voltage have the advantages of simple structure and high efficiency. In a multiple module system, where multiple resonant inverters are paralleled to the high frequency AC bus through connection inductors, it is necessary for the output voltage phase angles of the inverters be controlled so that the circulating current among the inverters be minimized. However, the phase angle of the resonant inverters output voltage can not be controlled with conventional phase shift modulation or pulse width modulation. The phase angle is a function of both the phase of the gating signals and the impedance of the resonant tank. In this paper, we proposed a pulse phase modulation (PPM) concept for the resonant inverters, so that the phase angle of the output voltage can be regulated. The PPM can be used to minimize the circulating current between the resonant inverters. The mechanisms of the phase angle control and the PPM were explained. The small signal model of a PPM controlled half-bridge resonant inverter was analyzed. The concept was verified in a half bridge resonant inverter with a series-parallel resonant tank. An HFAC power distribution system with two resonant inverters connected in parallel to a 500kHz, 28V AC bus was presented to demonstrate the applicability of the concept in a high frequency power distribution system.

병실 냉.난방장치용 태양 위치 추적기를 이용한 태양광 발전시스템에 관한 연구 (A study on Photovoltaic System to Considers a Solar Position Tracker for Air Conditioner a Clinic room)

  • 황락훈;나승권
    • 한국산학기술학회논문지
    • /
    • 제8권6호
    • /
    • pp.1355-1362
    • /
    • 2007
  • 본 논문에서는 태양광 발전의 효율을 높이기 위하여 센서와 마이크로프로세서를 이용한 태양광 위치추적 장치를 설계하여 고정 방식의 태양광 발전과 위치 추적 방식의 태양광 발전에 대하여 비교해 보았으며, 태양전지에 대한 특성 해석과 수학적 모델링을 통한 시뮬레이션을 행하여 태양전지 특성 사양과 비교해 보았다. 또한 전력변환 시스템을 Boost 컨버터와 전압형 인버터로 구성하여 각각에 대하여 실험하였으며, Boost 컨버터 제어에서 최대 전력점 추적을 위해 일정전압 제어법을 사용하였다. 인버터의 제어에서는 SPWM(Sinusoidal Pulse Width Modulation) 제어법을 사용하여 실험하여 좋은 결과를 나타내었다.

  • PDF

최대출력추종 제어를 포함한 단상 태양광 인버터를 위한 새로운 입출력 고조파 제거법 (A Novel Input and Output Harmonic Elimination Technique for the Single-Phase PV Inverter Systems with Maximum Power Point Tracking)

  • Amin, Saghir;Ashraf, Muhammad Noman;Choi, Woojin
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2019년도 전력전자학술대회
    • /
    • pp.207-209
    • /
    • 2019
  • This paper proposes a grid-tied photovoltaic (PV) system, consisting of Voltage-fed dual-active-bridge (DAB) dc-dc converter with single phase inverter. The proposed converter allows a small dc-link capacitor, so that system reliability can be improved by replacing electrolytic capacitors with film capacitors. The double line frequency free maximum power point tracking (MPPT) is also realized in the proposed converter by using Ripple Correlation method. First of all, to eliminate the double line frequency ripple which influence the reduction of DC source capacitance, control is developed. Then, a designing of Current control in DQ frame is analyzed and to fulfill the international harmonics standards such as IEEE 519 and P1547, $3^{rd}$ harmonic in the grid is directly compensated by the feedforward terms generated by the PR controller with the grid current in stationary frame to achieve desire Total Harmonic Distortion (THD). 5-kW PV converter and inverter module with a small dc-link film capacitor was built in the laboratory with the proposed control and MPPT algorithm. Experimental results are given to validate the converter performance.

  • PDF