• 제목/요약/키워드: Inverter design

검색결과 1,196건 처리시간 0.026초

PWM 인버터용 SNUBBER 설계 (Design of Snubber for PWM Inverter)

  • 오진석
    • 한국안전학회지
    • /
    • 제8권4호
    • /
    • pp.95-100
    • /
    • 1993
  • In power transistor switching circuit have shunt snubber(dv/dt limiting capacitor) and series snubber (di/dt limiting inductor). The shunt snubber is used to reduce the turn-off switching loss and the series snubber is used to reduce the turn-on switching loss. Design procedures are derived for selecting the capacitance, inductor and resistance to limit the peak voltage and current values. The action of snubber is analyzed and applied to the design for safety PWM inverter.

  • PDF

고주파 공진형 인버터식 X선 발생장치의 설계 (Design of High Frequency Resonant Inverter Type X-Ray Generator)

  • 이성길;박수강;백형래;정수복
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제51권1호
    • /
    • pp.34-39
    • /
    • 2002
  • Most X-ray generator had been used do rectifier type transformer high tension generator which is supplied in a clinical diagnosis. But it is difficult to miniaturize and become light weight. Also, because the ripple rate of tube voltage is high, X-ray generating efficiency is very low. Therefore, it is supplied gradually from abroad being developed high tension generator for inverter type X-ray generator which use semi-conductor switching element for electric power that have high speed switching ability to solved these problem. But, semi-conductor element of big capacity are used by X-ray tube's big consumption power and diffusion is difficult in the small size hospital because production cost is ascending by doing digital control through DSP and product price becomes expensive. Therefore, in this paper, design and manufactured CR type voltage divider for feedback control of tube voltage of high frequency resonance type inverter and high tension transformer for high frequency to apply economical diffusion type X-ray generator which have wide output voltage and load extent. It is Proved do X-ray generator and stability of X-ray tube's output characteristics through an experiment.

고속전철용 추진제어장치의 냉각용 인버터를 위한 제동초퍼 회로 설계 및 제어 (Design and Control of Braking Chopper Circuit for Ventilation Inverter of Traction Control System)

  • 조성준
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2011년도 전력전자학술대회
    • /
    • pp.314-315
    • /
    • 2011
  • This paper introduces the design and control method of braking chopper circuit which can supply input power to ventilation inverter of traction control system. The DC input voltage from auxiliary block (static inverter) is normally used as an input of ventilation inverter. It converts DC input to AC output voltage to drive cooling fans for traction control system and traction motors. The electrical braking force is very important for high speed train to guarantee safety even though the train is running in the dead section where the pantograph voltage is not supplied. When the high speed train decelerate speed in dead section, the regenerative energy is dissipated by braking resistor. This paper proposed the braking chopper control method to implement rheostatic braking function and the appropriate chopper circuit for supplying voltage source to ventilation inverter during rheostatic braking mode. The proposed chopper circuit makes it possible for traction control system to regenerate power continuously regardless of the existence of pantograph voltage. The feasibility of proposed braking chopper control and circuit were proven by inertia load test and actual train field test.

  • PDF

Design of a Hybrid Controller for the Three-phase Four-leg Voltage-source Inverter with Unbalanced Load

  • Doan, Van-Tuan;Kim, Ki-Young;Choi, Woojin;Kim, Dae-Wook
    • Journal of Power Electronics
    • /
    • 제17권1호
    • /
    • pp.181-189
    • /
    • 2017
  • The three-phase four-leg voltage-source inverter topology is an interesting option for the three-phase four-wire system. With an additional leg, this topology can achieve superior performance under unbalanced and nonlinear load conditions. However, because of the low bandwidth of conventional controllers in high-power inverter applications, the system cannot guarantee a balanced output voltage under the unbalanced load condition. Most of the methods proposed to solve this problem mainly use the multiple synchronous frame method, which requires several controllers and a large amount of computation because of frame transformation. This study proposes a simple hybrid controller that combines proportional-integral (PI) and resonant controllers in the synchronous frame synchronized with the positive-sequence component of the output voltage of the three-phase four-leg inverter. The design procedure for the controller and the theoretical analysis are presented. The performance of the proposed method is verified by the experimental results and compared with that of the conventional PI controller.

평판형 및 아치형 태양광발전 시스템의 성능평가 분석 (The Performance Evaluation Analysis of PV System for Arch and Flat-Plate Type)

  • Zheng-GuoPiao;최연옥
    • 전기학회논문지
    • /
    • 제64권7호
    • /
    • pp.1012-1018
    • /
    • 2015
  • The studies on the operating performance analysis or design about the fixed tilt angle flat-plate photovoltaic (PV) system are still lively going off. However the operating property analysis about the arch type PV system which means PV array were designed as round type is dissatisfied. In this paper, we theoretically established the factors which are cause of the deterioration in performance of arch type PV system. In addition, we use the Solar Pro simulation tools to design both flat-plate type and arch type 30kW PV systems. The simulations about arch type PV system applied two ways such as central inverter and string inverter were conducted. The performance ratio (PR) of the PV system with flat-plate type shows the highest value 74[%] when the tilt angle is 30°. In case of arch type, when applying central inverter method, PR value shows approximately 73[%] and no more difference with arch type of the PV array. This value shows 1[%] decrease compare with the flat-plate type. However when applying string inverter methods, the average PR value shows 80 % and 6% improved than the central inverter method.

태양광 발전시스템에서 사용하는 마이크로인버터용 무선지능형제어기 설계 및 구현 (Design and Implementation of Wireless Intelligent Controller for Micro-Inverter in Solar Power Systems)

  • 한성택
    • 디지털산업정보학회논문지
    • /
    • 제15권4호
    • /
    • pp.9-17
    • /
    • 2019
  • Sun power generation systems which use large capacity centralized inverters have loss of power generation due to cloud and building shadows, pollution, cell deterioration, etc. To minimize loss of power generation, decentralized solar power systems using multiple micro-inverters are being proposed as an alternative. A distributed solar power system consisting of a system-connected system uses power line communication to collect data from the micro-inverters. Power line communication has the advantage of using power lines without separate lines for data transmission, but in distributed solar power generation systems that use a large number of micro-inverters, the bit error rate is less reliable due to the phenomenon caused by limited transmission power, high load interference and noise, variable signal attenuation, and impedance characteristics. So we proposed wireless intelligent controller for micro-inverter that is used to build distributed solar power systems. and we design and implement that. Further, the proposed wireless intelligent controller for micro-inverter was used to establish a small-volume solar power plant to check its function and operation.

Design and Implementation of a Low Cost Grid-Connected 5 kVA Photovoltaic System with Load Compensation Capability

  • Mejdar, Reza Seifi;Salimi, Mahdi;Zakipour, Adel
    • Journal of Power Electronics
    • /
    • 제16권6호
    • /
    • pp.2306-2314
    • /
    • 2016
  • Design and implementation of a low cost grid-connected 5kVA solar photovoltaic (PV) system is proposed in this paper. Since the inverter is a major component of the PV system, the B4 inverter used in this paper reduces the total cost of the PV system. In order to eliminate the massive transformer, the PV system is connected to the grid through IGBT switches. In addition to injection of active power into the grid, the B4 inverter can compensate reactive power and reduce harmonics of the nonlinear loads. A TMS320F28335 DSP processor is used for effective control of the B4 inverter. Various features of this processor enable the implementation of the necessary control algorithms. As a first step, the PV system is simulated and evaluated in Matlab/Simulink. In the second step, hardware circuits are designed and implemented based on the simulation results. The operation of the PV system has been evaluated under balanced, unbalanced, linear and nonlinear loads which proves its accuracy and efficiency.

압전 변압기를 이용한 멀티 램프 구동용 인버터 설계 (Design of Inverter for Driving the Multi-lamp using an Piezoelectric Transformers)

  • 조성구;임영철;양승학
    • 전력전자학회논문지
    • /
    • 제10권2호
    • /
    • pp.130-137
    • /
    • 2005
  • LCD는 광변조기능을 가지는 수광 소자로서 발광원인 백라이트를 필요로 하는데 일반적으로 냉음극 방전램프(CCFL: Cold Cathode Fluorescent Lamp)가 사용된다. 기존의 권선형 변압기를 이용한 인버터를 구성하여 멀티램프를 구동하고 있지만 이는 코어나 권선 손실에 의한 효율 저하와 부피나 중량의 증가, 그리고 과열에 의한 화재의 위험성을 가지고 있다. 이러한 문제들을 해결하기 위해 본 논문에서는 압전 변압기를 이용한 멀티램프 구동용 인버터를 설계 지침에 따라 구성하였다. 인버터 하나로 압전 변압기를 병렬로 연결하는 방식을 이용하였고, 또한 전류 부담이 적은 외관 전극 형광 램프(EEFL: External Electrode Fluorescent Lamp)를 이용한 멀티램프 구동 방법이 압전 인버터에 적용 가능한지를 확인하였다.

Design and Research on High-Reliability HPEBB Used in Cascaded DSTATCOM

  • Yang, Kun;Wang, Yue;Chen, Guozhu
    • Journal of Power Electronics
    • /
    • 제15권3호
    • /
    • pp.830-840
    • /
    • 2015
  • The H-bridge inverter is the fundamental power cell of the cascaded distribution static synchronous compensator (DSTATCOM). Thus, cell reliability is important to the compensation performance and stability of the overall system. The concept of the power electronics building block (PEBB) is an ideal solution for the power cell design. In this paper, an H-bridge inverter-based “plug and play” HPEBB is introduced into the main circuit and the controller to improve the compensation performance and reliability of the device. The section that discusses the main circuit primarily emphasizes the design of electrical parameters, physical structure, and thermal dissipation. The section that presents the controller part focuses on the principle of complex programmable logic device -based universal controller This section also analyzes typical reliability and anti-interference issues. The function and reliability of HPEBB are verified by experiments that are conducted on an HPEBB test-bed and on a 10 kV/± 10 Mvar DSTATCOM industrial prototype.

Controller Design for a Quick Charger System Suitable for Electric Vehicles

  • Jeong, Hae-Gwang;Lee, Kyo-Beum
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권5호
    • /
    • pp.1122-1130
    • /
    • 2013
  • This paper proposes a new design for quick battery charger systems for electric vehicles that consists of a three-phase inverter and a full-bridge converter which use the phase-shift method. The 3-phase inverter controls the input and DC-link voltage by use of a current controller and a voltage controller. The full-bridge converter transfers the DC-link voltage to a fixed output voltage. Designs for the output-side converter and controller for improved performance are proposed in this paper. Design schemes for the filter and controller of an input-side inverter are also presented. Furthermore, the paper proposes a compensation method for the offset current that is caused by switch failure and circuit problems. Simulations and experiments have been performed on a 50kW-battery charger system that is suitable for vehicles. The presented results verify the validity of the proposed method and the superiority of the system over conventional methods.