• 제목/요약/키워드: Inverter Filter

검색결과 529건 처리시간 0.034초

저역통과 LC필터를 가진 전브리지형 인버터의 특성과 응용에 대한 연구 (A Study on the Application and Characteristics of a Full Bridge Inverter with Low Pass LC Filter)

  • 박진길;노영오;신원길
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제17권5호
    • /
    • pp.99-111
    • /
    • 1993
  • In this paper, the current waveform and dynamic characteristics of the proposed system which is composed of a full bridge inverter and low pass LC filter is investigated through the results of computer simulation and experiment to find out the good performance of variable speed AC motor. By the experiment results, it is confirmed that the load current of pseudo sine waves is to be got by the proposed low pass LC filter and the speed of single phase AC motor driven by a full bridge inverter can be smoothly controlled by use of digital PID controller.

  • PDF

Experimental and Numerical Analysis of a Simple Core Loss Calculation for AC Filter Inductor in PWM DC-AC Inverters

  • Lee, Kyoung-Jun;Cha, Honnyong;Lee, Jong-Pil;Yoo, Dong-Wook;Kim, Hee-Je
    • Journal of Power Electronics
    • /
    • 제13권1호
    • /
    • pp.113-121
    • /
    • 2013
  • This paper introduces a simple core loss calculation method for output filter inductor in pulse width modulation (PWM) DC-AC inverter. Amorphous C-core (AMCC-320) is used to analyze the core loss. In order to measure core loss of the output filter inductor and validate the proposed method, a single-phase half-bridge inverter and a calorimeter are used. By changing switching frequency and modulation index (MI) of the inverter, core loss of the AMCC-320 is measured with the lab-made calorimeter and the results are compared with calculated core loss. The proposed method can be easily extended to other core loss calculation of various converters.

인버터구동 고압전동기 열화특성 분석 및 필터 설계기법 확립 (Insulation System and Filter Design for Inverter-Fed Motor)

  • 최영찬;이상동;김익모;정명길
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 B
    • /
    • pp.711-713
    • /
    • 2000
  • Recently, the insulation breakdown accident happened at 6.6kV inverter driving motor brings out the reliability decrease to the motor driving system. We need to find the solution with system engineering level. The objectives of this study are developing the appropriate filter for the drive to protect the motor and the insulation system of motor which is driven by inverter. The circuit parameters of cable are calculated by EMTP(Electromagnetic Transient Program) to simulate the system. And we use MATLAB to find the appropriate filter parameter. The simulation and the test results are compared to verify the suitability of the filter parameter. We clarify the cause of the deterioration of the inverter driving motor through the analysis of insulation breakdown accidents. The endurance test scheme and the configuration method of insulation system are established.

  • PDF

새로운 Clocking 방식에 의한 Voltage Inverter Switch 및 Switched Capacitor Filter 설계에의 응용 (A Voltage Inverter Switch With a New Clocking Scheme and its Application to Switched Capacitor Filter Design)

  • 이방원;박송배
    • 대한전자공학회논문지
    • /
    • 제18권4호
    • /
    • pp.1-11
    • /
    • 1981
  • 본 논문에서는 VIS (voltage inverter switch)를 사용한 SCF(switched capacitor filter) 설계 방법에 있어서 종래에 발표된 clocking scheme을 일반화하고, 이로써 생기는 RC, RL 등의 병렬소자들과 유손실 또는 무손실 LC 병렬공진 소자들을 제시하였다. 또 이들 업자들을 SCF의 설계에 응용함으로써 종래의 방법에 비해 연산증폭기와 Capacitor의 수를 줄일 수 있는 설계 방법에 대해 기술하였다. 이 결과로 SCF를 더욱 작은 칩(chip) 면적으로 집적화 할 수 있겠다. 또 새로운 구조를 갖는 VIS를 제시하고 이를 사명한 저역통과 여파기와 간단한 대역골지 여파기를 실험하여 그 결과가 이론치와 잘 일치함을 보였다.

  • PDF

계통연계형 인버터의 LCL필터 최적 설계기법 (Optimized LCL filter Design Method of Utility Interactive Inverter)

  • 정상혁;최세완
    • 전력전자학회논문지
    • /
    • 제18권1호
    • /
    • pp.103-109
    • /
    • 2013
  • The conventional LCL filter design method of the utility interactive inverter considers only harmonics attenuation of the current injected to the grid. However, in case of utility-interactive inverter with critical load the voltage quality of the critical load should also be considered for LCL filter design. Also, considering cost and volume of LCL filters. it is important to have minimum values of inductance and capacitance as far as the harmonic standards are satisfied. In this paper a LCL filter design method is proposed to satisfy not only the harmonic standards of the grid current during the grid-connected mode but the voltage quality of the critical load during grid-connected mode and stand-alone mode. With the proposed method optimized values of LCL filters could be obtained by applying weighting factor to voltage ripple across the critical load, inductor volume, amount of reactive current and system bandwidth.

순시전력이론을 통한 계통연계 PWM 인버터 시스템의 능동댐핑 기법 (An active damping method of a grid-connected PWM Inverter using an instantaneous power theory)

  • 정해광;이교범;강신일;이현영;권오정;송승호
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2008년도 하계학술대회 논문집
    • /
    • pp.85-87
    • /
    • 2008
  • The demand of a three phase PWM inverter for the purpose of power control or grid-connecting is increasing. This inverter is connected to a grid through an L-filter or LCL-filter to reduce the harmonics caused by switching. An LCL-filter can reduce the harmonic of a low switching frequency and generate a satisfactory level of grid side current with a relatively low-inductance than an L-filter. But the additional poles caused by the LC part affects a stability problem due to induced resonance of the system. This paper presents a compensation method using a power theory to improve performance, the designed LCL-filter system and to reduce the stability problems caused by resonance. The effectiveness of the proposed algorithm is verified by simulations.

  • PDF

인덕터 내부저항을 고려한 LCL 필터의 능동댐핑 특성 (Active Damping Characteristics on Virtual Series Resistances of LCL Filter for Three-phase Grid-connected Inverter)

  • 김용중;김효성
    • 전력전자학회논문지
    • /
    • 제21권1호
    • /
    • pp.88-93
    • /
    • 2016
  • LCL filters are widely used in high-order harmonics attenuation of output currents in grid-connected inverters. However, output currents of grid-connected inverters with LCL filters can become unstable because of the resonance of the filters. Given that the characteristics of output currents in inverters mostly depend on filter performance, the exact analysis of filters by considering parasitic components is necessary for both harmonics attenuation and current control. LCL filters have three or four parasitic components: the series and/or parallel resistance of the filter capacitor and the series resistance of the two filter inductors. Most studies on LCL filters have focused on the parasitic components of the filter capacitor. Although several studies have addressed the parasitic components of the filter inductor at the inverter side, no study has yet investigated the concurrent effects of series resistance in both filter inductors in detail. This paper analyzes LCL filters by considering series resistance in both filter inductors; it proposes an active damping method based on the virtual series resistance of LCL filters. The performance of the proposed active damping is then verified through both simulation and experiment using Hardware-in-the-Loop Simulator(HILS).

Analysis and Design of LCL Filter with Passive Damping Circuits for Three-phase Grid-connected Inverters

  • Ahn, Hyo Min;Oh, Chang-Yeol;Sung, Won-Yong;Ahn, Jung-Hoon;Lee, Byoung Kuk
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권1호
    • /
    • pp.217-224
    • /
    • 2017
  • The analysis and design process of the LCL filter with passive damping circuits for three-phase grid-connected inverter are presented based on the generalized model of LCL filter. Several types of the passive damping circuits in previous studies could be compared and analyzed by using the generalized model considering various design criteria of passive damping circuits. According to the analysis in this paper, a reasonable configuration of passive damping circuits for three-phase grid-connected inverters is proposed. The validity of the proposed design process is verified by informative simulation and experimental results.

PWM인버터의 출력 LC필터에 의한 공진전압 억제 기법 (Method for Damping Resonant Voltages on the Output LC Filter of PWM Inveter)

  • 최경진;전태원;이흥희;노의철;김흥근
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2004년도 전력전자학술대회 논문집(1)
    • /
    • pp.415-419
    • /
    • 2004
  • The U filter has been generally used to filter the output voltage of PWM inverter to the sinusoidal waveform. The resonant voltage on the output voltage of PWM inverter may be generated due to LC filter. This paper proposed the algorithm to damp the resonant voltage using the virtual resistor without decreasing the efficiency by the power loss in the real resistor The method is appled to the vector controlled induction motor driven by the PWM inverter with the LC filter. The simulation results are carried out to verify the performances of the proposed algorithm.

  • PDF

제어기 성능을 고려한 전압형 인버터의 출력 LC필터 설계 (Output LC Filter Design of Voltage Source Inverter Considering the Performance of Controller)

  • 민완기;김재식;최재호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 학술대회 논문집 전문대학교육위원
    • /
    • pp.206-211
    • /
    • 2005
  • The LC filter design procedure of the inverter output filter is described. The transfer function of the filter output voltage to the load current is described with the capacitor value and the system time constant considering the system controller. By using the closed form of the relation between the filter capacitor value and the system time constant, the capacitor value can be calculated with the given system time constant and vice versa. It is more practical for the implementation of power and control circuit of inverter. And as the effect of the load current to the voltage distortion can be calculated from the closed form, it is possible to analyze the system how much the voltage waveform is distorted in case of the nonlinear load. All the proposed design procedure is verified with the simulation and experimental results.

  • PDF