• 제목/요약/키워드: Intraoral digital impression

검색결과 65건 처리시간 0.027초

In-vitro evaluation of marginal and internal fit of 3-unit monolithic zirconia restorations fabricated using digital scanning technologies

  • Ozal, Cise;Ulusoy, Mutahhar
    • The Journal of Advanced Prosthodontics
    • /
    • 제13권6호
    • /
    • pp.373-384
    • /
    • 2021
  • PURPOSE. This study aimed to compare the marginal and internal fit of 3-unit monolithic zirconia restorations that were designed by using the data obtained with the aid of intraoral and laboratory scanners. MATERIALS AND METHODS. For the fabrication of 3-unit monolithic zirconia restorations using impressions taken from the maxillary master cast, plaster cast was created and scanned in laboratory scanners (InEos X5 and D900L). The main cast was also scanned with different intraoral scanners (Omnicam [OMNI], Primescan [PS], Trios 3 [T3], Trios 4 [T4]) (n = 12 per group). Zirconia fixed partial dentures were virtually designed, produced from presintered block, and subsequently sintered. Marginal and internal discrepancy values (in ㎛) were measured by using silicone replica method under stereomicroscope. Data were statistically analyzed by using 1-way ANOVA and Kruskal Wallis tests (P<.05). RESULTS. In terms of marginal adaptation, the measurements on the canine tooth indicated better performance with intraoral scanners than those in laboratory scanners, but there was no difference among intraoral scanners (P<.05). In the premolar tooth, PS had the lowest marginal (86.9 ± 19.2 ㎛) and axial (92.4 ± 14.8 ㎛), and T4 had the lowest axio-occlusal (89.4 ± 15.6 ㎛) and occlusal (89.1 ± 13.9 ㎛) discrepancy value. In both canine and premolar teeth, the D900L was found to be the most marginally and internally inconsistent scanner. CONCLUSION. Within the limits of the study, marginal and internal discrepancy values were generally lower in intraoral scanners than in laboratory scanners. Marginal discrepancy values of scanners were clinically acceptable (< 120 ㎛), except D900L.

디지털 치과모형의 정확도 평가 방법에 대한 고찰 (A review on the accuracy assessment methods of 3-dimensional digital dental models)

  • 박지수;임영준;이정원;김봉주
    • 구강회복응용과학지
    • /
    • 제35권2호
    • /
    • pp.55-63
    • /
    • 2019
  • 본 논문은 기존에 선행되었던 연구들을 바탕으로 디지털 모형의 정확도를 평가하는 여러 가지 방법에 관하여 정리하였다. 디지털 모형의 정확도 평가 시, 시험자 교육과 인공적 지표의 사용을 통해 오차를 줄일 수 있다. 디지털 치아 모형의 정확도 평가법은 크게 선형 측정법, 2차원 단면 분석법, 3차원 최적합 분석법으로 분류할 수 있다. 스캐너의 기술이 발전함에 따라 디지털 인상 기술과 전통적 인상법의 정확도를 비교하는 많은 연구들이 이루어지고 있다. 다양한 방법을 이용하여 디지털 모형의 정확도를 평가할 수 있으며, 앞으로 스캐너의 기술 향상 및 3차원 모형 분석 소프트웨어의 개발에 따라 디지털 모형의 정확도 평가 방법이 더욱 효과적으로 변화할 것이라 생각된다. 이 논문에서는 디지털 모형의 정확도를 평가하는 방법들에 대해 소개하고, 각각의 상황에 따른 효과적인 정확도 분석법에 대해 알아보고자 한다.

비정형적인 악궁을 가진 완전 무치악 환자에서 기성 트레이와 구강 스캐너를 이용한 인상 채득 방법의 비교 연구: 증례 보고 (A comparative study of impression methods using stock tray and intraoral scanner in a completely edentulous patient with an atypical arch shape: a case report)

  • 박재훈;김지현;서재민;이정진;박연희
    • 대한치과보철학회지
    • /
    • 제61권4호
    • /
    • pp.344-355
    • /
    • 2023
  • 총의치 제작 과정 중 정확한 최종인상을 얻기 위해서는 정확한 예비인상 채득이 선행되어야 한다. 본 증례에서는 비정형적인 악궁 형태를 가진 환자에서 기성 트레이 및 구강 스캐너로 채득하여 제작한 예비모형과 개인트레이를 비교하였다. 58세 남자 환자로 상, 하악 총의치 제작을 위해 본원 구강악안면외과에서 의뢰되었다. 상하악궁 모두 좁고 긴 형태로 비정형적인 형태를 보였다. 기성 트레이를 이용하여 채득한 예비모형은 구강 스캐너를 이용한 예비 모형에 비해 상악의 경우, 협측의 변연이 과연장되었고, 후방 구개 폐쇄 부위에서는 압박되어 있었다. 또한 하악에서도 과연장되었으나, 상악에 비하여 그 양이 많지 않았다. 그리고 구강 스캐너에 의해 채득된 예비모형은 기성 트레이로 채득된 예비 모형에 비해 저연장되었으나, 해부학적 지표는 충분히 인기되었다. 기성 트레이에 의해 제작된 개인 트레이는 IOS에 의해 제작된 개인 트레이에 비하여 구강 내 시적 시, 개인 트레이의 조정량이 많았고 진료 시간이 증가하였다. 본 증례를 통해 비정형적인 악궁을 가진 환자에게 3D 구강 스캐너로 인상을 채득하는 것이 대안이 될 수 있음을 보고하는 바이다.

디지털 구강스캐너로 모형 없이 제작한 전부지르코니아 수복물의 변연 및 내면 적합도 평가 (Evaluation of marginal and internal gap under model-free monolithic zirconia restoration fabricated by digital intraoral scanner)

  • 이종원;박지만
    • 대한치과보철학회지
    • /
    • 제54권3호
    • /
    • pp.210-217
    • /
    • 2016
  • 목적: 본 연구의 목적은 실제 환자에서 디지털 구강스캐너로 모형 없이 제작한 보철물의 변연 및 내면 적합도를 평가하는 것이다. 대상 및 방법: 전향적 임상시험으로 시행한 본 예비 연구는 총 11개의 수복물을 대상으로 하였다. 구강스캐너(TRIOS, 3shape, Copenhagen, Denmark)로 디지털 구강인상을 채득한 후, 캐드 디자인 및 밀링 가공 과정을 통해 전부지르코니아 수복물을 제작하였다. 완성된 지르코니아관을 환자 구강 내에 시적하였고, 레플리카 술식으로 보철물-지대치 복제물을 얻었다. 이를 근원심, 협설 방향으로 잘라 변연오차, 변연간극과 축벽부, 선각부, 교합면부의 내면간극을 측정하였다. 통계처리는 Kruskal-Wallis 검정과 Mann-Whitney U 검정을 이용하여 통계적 유의성을 분석하였다(${\alpha}=.05$). 결과: 복제물을 통한 적합도 분석 결과, 근원심, 협설 절편 사이에는 통계적으로 유의한 차이가 없었다(P>.05). 변연간극에 불일치가 있었으며, 변연 오차가 변연간극 보다 컸다(P<.01). 결론: 본 연구의 한계 내에서, 구강스캐너로 모형 없이 제작한 전부지르코니아 수복물의 적합도는 임상적으로 허용할만한 결과를 보였다. 그러나 지르코니아관의 변연부위가 과풍융되는 경향이 있었으므로 주의 깊은 임상 적용 및 추적 연구가 요구된다.

골관절증 환자에서 하악 운동 추적 장치와 이중 스캔 기법을 활용한 완전 구강 회복 증례 (Complete mouth rehabilitation, using jaw motion tracking and double scan technique in a patient with osteoarthrosis: a case report)

  • 정서경;곽재영;허성주;김성균;박지만
    • 대한치과보철학회지
    • /
    • 제62권1호
    • /
    • pp.82-94
    • /
    • 2024
  • 본 증례는 치아의 전반적 마모를 보이며 구치부 지지가 소실된 환자를 대상으로 전악 수복을 진행한 증례이다. 측두 하악 관절의 상태를 분석 후, 붕괴된 교합을 회복하기 위해 다수의 임플란트가 식립되었다. 고정체/지대주 수준의 인상 채득에서, 교차 마운팅을 위한 여러 번의 복잡한 교합 기록을 동반하는 전통적 인상 채득 방법 대신 구강 스캐너를 이용한 방식을 채득하였다. 하악의 불안정한 움직임을 반영하기 위해, '하악 운동 추적(jaw motion tracking)'장치와 '디지털 안궁 이전(digital face-bow transfer)'을 이용하였고, 이차 임시 수복물을 기반으로 하여 최종 수복물로 복제하는 '이중 스캔 기법(double scan technique)'으로 최종 수복물을 제작하였다. 위와 같은 디지털 기술을 이용하여 불안정한 교합을 갖는 환자에게 보다 짧은 체어 타임으로 완전 구강 회복을 진행할 수 있다.

Effect of angulation on the 3D trueness of conventional and digital implant impressions for multi-unit restorations

  • Ozay Onoral;Sevcan Kurtulmus-Yilmaz;Dilem Toksoy;Oguz Ozan
    • The Journal of Advanced Prosthodontics
    • /
    • 제15권6호
    • /
    • pp.290-301
    • /
    • 2023
  • PURPOSE. The study aimed to determine the influence of implant angulation on the trueness of multi-unit implant impressions taken through different techniques and strategies. MATERIALS AND METHODS. As reference models, three partially edentulous mandibular models (Model 1: No angulation; Model 2: No angulation for #33, 15-degree distal angulation for #35 and #37; Model 3: No angulation for #33, 25-degree distal angulation for #35 and #37) were created by modifying the angulations of implant analogues. Using a lab scanner, these reference models were scanned. The obtained data were preserved and utilized as virtual references. Three intraoral scanning (IOS) strategies: IOS-Omnicam, ISO-Quadrant, and IOS-Consecutive, as well as two traaditional techniques: splinted open tray (OT) and closed tray (CT), were used to create impressions from each reference model. The best-fit alignment approach was used to sequentially superimpose the reference and test scan data. Computations and statistical analysis of angular (AD), linear (LD), and 3D deviations (RMS) were performed. RESULTS. Model type, impression technique, as well as interaction factor, all demonstrated a significant influence on AD and LD values for all implant locations (P < .05). The Model 1 and SOT techniques displayed the lowest mean AD and LD values across all implant locations. When considering interaction factors, CT-Model 3 and SOT-Model 1 exhibited the highest and lowest mean AD and LD values, respectively. Model type, impression technique, and interaction factor all revealed significant effects on RMS values (P ≤ .001). CT-Model 3 and SOT-Model 1 presented the highest and lowest mean RMS values, respectively. CONCLUSION. Splinted-OT and IOS-Omnicam are recommended for multi-unit implant impressions to enhance trueness, potentially benefiting subsequent manufacturing stages.

구강 내 디지털 인상채득을 통한 맞춤형 지대주와 시멘트 합착 후 나사형 임플란트 보철 수복 증례 (Customized abutment and screw-type implant prostheses after cementation based on the digital intra-oral impression technique)

  • 홍용신;박은진;김선종;김명래;허성주;박지만
    • 대한치과보철학회지
    • /
    • 제50권1호
    • /
    • pp.67-73
    • /
    • 2012
  • 최근 디지털 인상채득 시스템이 개발되면서 이를 기존의 CAD/CAM 시스템과 접목한 인레이, 온레이, 크라운이나 간단한 계속가공의치 등의 고정성 보철물의 제작이 활발히 소개되고 있다. 그러나 임플란트 보철에서는 주로 기존의 아날로그식 인상채득 후 이를 스캔하여 제작하는 방법이 사용되어 왔으나, 구강 내 디지털 스캔한 데이터를 이용하여 나사형 보철물을 제작하는 술식은 아직 활발히 이루어지지 않았다. 이에 본 증례보고에서는 6명의 환자를 대상으로 구강 내 스캐너인 iTero를 사용하여 디지털 스캔을시행한후그중다섯명은맞춤형지대주와 시멘트 합착 후 나사형 임플란트 보철물(screw-retained implant prosthesis after cementation, or SCRP)을 제작하였고, 임상적으로 기능과 심미적인 측면으로 만족할 만한 결과를 얻었기에 이를 보고하고자 한다.

규격화된 구내 표준 방사선사진의 계수 공제 방사선학적 평가 (DIGITAL SUBTRACTION RADIOGRAPHIC EVALUATION OF THE STANDARDIZED PERIAPICAL INTRAORAL RADIOGRAPHS)

  • 조봉혜;나경수
    • 치과방사선
    • /
    • 제23권1호
    • /
    • pp.125-136
    • /
    • 1993
  • The geometrically standardized intraoral radiographs using 5 occlusal registration materials were taken serially from immediate, 1 day, 2, 4, 8, 12, and 16 weeks after making the bite blocks. And the resultant images were digitally subtracted using the immediately taken film as reference images. The qualities of those subtracted images were evaluated to check the degree of reproducibility of each impression material. The results were as follows: 1. The standard deviations of the grey scales of the overall subtracted images were 4.9 for Exal1ex, 7.2 for Pattern resin, 9.0 for Tooth Shade Acrylic, 12.2 for XCP only, 14.8 for Impregum. the lesser the standard deviation, the better the quality of the subtracted images. 2. The standard deviation of the grey scales of the overall subtracted images were grossly related to those of the localized horizontal line of interest. 3. Exaflex which showed the best subtracted image quality had 15 cases of straight, 14 cases of wave, 1 case of canyon shape. Impregum which showed the worst subtracted image quality had 4 cases of straight, 8 cases of wave, 18 cases of canyon shape respectively.

  • PDF

Comparison of the accuracy of digitally fabricated polyurethane model and conventional gypsum model

  • Kim, So-Yeun;Lee, So-Hyoun;Cho, Seong-Keun;Jeong, Chang-Mo;Jeon, Young-Chan;Yun, Mi-Jung;Huh, Jung-Bo
    • The Journal of Advanced Prosthodontics
    • /
    • 제6권1호
    • /
    • pp.1-7
    • /
    • 2014
  • PURPOSE. The accuracy of a gypsum model (GM), which was taken using a conventional silicone impression technique, was compared with that of a polyurethane model (PM), which was taken using an iTero$^{TM}$ digital impression system. MATERIALS AND METHODS. The maxillary first molar artificial tooth was selected as the reference tooth. The GMs were fabricated through a silicone impression of a reference tooth, and PMs were fabricated by a digital impression (n=9, in each group). The reference tooth and experimental models were scanned using a 3 shape convince$^{TM}$ scan system. Each GM and PM image was superimposed on the registered reference model (RM) and 2D images were obtained. The discrepancies of the points registered on the superimposed images were measured and defined as GM-RM group and PM-RM group. Statistical analysis was performed using a Student's T-test (${\alpha}=0.05$). RESULTS. A comparison of the absolute value of the discrepancy revealed a significant difference between the two groups only at the occlusal surface. The GM group showed a smaller mean discrepancy than the PM group. Significant differences in the GM-RM group and PM-RM group were observed in the margins (point a and f), mesial mid-axial wall (point b) and occlusal surfaces (point c and d). CONCLUSION. Under the conditions examined, the digitally fabricated polyurethane model showed a tendency for a reduced size in the margin than the reference tooth. The conventional gypsum model showed a smaller discrepancy on the occlusal surface than the polyurethane model.

디지털 스캔을 이용하여 제작된 임플란트 수술가이드의 정확도 (Accuracy assessment of implant placement using a stereolithographic surgical guide made with digital scan)

  • 정승미;방정환;황찬현;강세하;최병호;방일흠;전형태;안성훈
    • 대한치과보철학회지
    • /
    • 제53권2호
    • /
    • pp.111-119
    • /
    • 2015
  • 목적: 인상재와 석고모형을 사용하지 않고 디지털 영상 만을 사용하여 제작된 수술가이드를 이용한 치과 임플란트 수술의 정확도를 평가하고자 하였다. 재료 및 방법: 상하악 부분 무치악 모델 6개 세트를 본 연구에 사용하였다. 모델을 환자 구강구조로 간주하고 부분 무치악 모델을 Trios 구강스캐너로 디지털 인상을 채득하였다. 수술가이드의 정확도 평가를 위해 제작된 Reference plate를 모델의 교합면에 고정한 상태로 CBCT를 촬영하였다. CBCT에서 얻은 영상과 디지털 인상에서 얻은 영상을 정합하고 정합한 영상에서 임플란트 식립위치를 진단하고 수술가이드를 디자인하였다. 제작된 수술가이드를 이용하여 부분 무치악 모델에서 임플란트를 식립하였다. 시술 후, 시술 전과 동일한 방법으로 CBCT를 촬영하여 시술 전 컴퓨터 소프트웨어에서 측정한 수치와 시술 후 CBCT촬영하여 소프트웨어상에서 측정한 시술 후 수치 사이 차이점을 비교하였다. 결과: 평균거리오차가 임플란트 상단 X축에서 0.27 mm, Y축에서 0.29 mm 였으며, 임플란트 하단(Apex)부위에서는 X축에서 0.11 mm, Y축에서 0.14 mm 평균각도오차가 X축에서 $0.26^{\circ}$, Y축에서 $0.26^{\circ}$ 였다. 평균수직오차는 +0.44 mm로 시술 전 계획한 높이보다 평균 0.44 mm 더 위로 임플란트가 식립되었다. 결론: 본 연구의 결과는 인상재와 석고모형을 사용하지 않고 디지털 영상 만을 사용하여 제작된 수술가이드를 사용하여 임플란트를 시술할 경우 계획한 임플란트 식립 위치와 방향으로 높은 정확도를 가지고 임플란트를 식립할 수 있음을 보여 주었다.