• Title/Summary/Keyword: Intraocular pressure(IOP)

Search Result 39, Processing Time 0.021 seconds

Intraocular Pressure and Its Determinants in Subjects With Type 2 Diabetes Mellitus in India

  • Biswas, Sayantan;Raman, Rajiv;Koluthungan, Vaitheeswaran;Sharma, Tarun
    • Journal of Preventive Medicine and Public Health
    • /
    • v.44 no.4
    • /
    • pp.157-166
    • /
    • 2011
  • Objectives: This study was conducted to show the intraocular pressure (IOP) distribution and the factors affecting IOP in subjects with type 2 diabetes mellitus (DM) in India. Methods: We measured the anthropometric and biochemical parameters for confirmed type 2 DM patients. A comprehensive ocular examination was performed for 1377 subjects aged > 40 years and residing in Chennai. Results: A significant difference in IOP (mean ${\pm}$ standard deviation) was found between men and women ($14.6{\pm}2.9$ and $15.0{\pm}2.8$ mmHg, p = 0.005). A significantly elevated IOP was observed among smokers, subjects with systemic hypertension and women with clinically significant macular edema (CSME). After a univariate analysis, factors associated significantly with higher IOP were elevated systolic blood pressure, elevated resting pulse rate and thicker central corneal thickness (CCT). In women, elevated glycosylated hemoglobin was associated with a higher IOP. After adjusting for all variables, the elevated resting pulse rate and CCT were found to be associated with a higher IOP. Conclusions: Systemic hypertension, smoking, pulse rate and CCT were associated with elevated intraocular pressure in type 2 DM. Women with type 2 DM, especially those with CSME, were more prone to have an elevated IOP.

A Study of the Intraocular Pressure of Korean Youth (한국인 청년의 안압 측정)

  • Kim, Sang-Moon
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.11 no.2
    • /
    • pp.91-97
    • /
    • 2006
  • The intraocular pressure for Korean youth were measured by using tonometer (AT555-Reichert). The relative frequency distributions of intraocular pressures have been studied for samples of 1,027 persons(475 males, 552 females). The most commonly recorded IOP for both men and women was around 14.5mmHg and 17.5mmHg, respectively. They were in the range of 7 to 23mmHg(males) and 7 to 22mmHg(females). The median pressure(cumulative frequency=0.5%) is 13.0~16.5mmHg for males and 16.5~18.5mmHg for females, so the values for females are slightly higher than males. The mean pressure is 15.2mmHg for males and 15.8mmHg for females, respectively. The 98% of population was in the range of the normal IOP. There are long-term diurnal variation in mean intraocular pressure and the IOP was decreased as a function of time from morning to night. The measured IOP was affected by several factors: exercise made to decrease the IOP and tight collars, dark places and posture of decubitus position got to elevate the IOP.

  • PDF

The Distribution of Intraocular Pressure and Its Association With Metabolic Syndrome in a Community

  • Park, Sang-Shin;Lee, Eun-Hee;Jargal, Ganchimeg;Paek, Do-Myung;Cho, Sung-Il
    • Journal of Preventive Medicine and Public Health
    • /
    • v.43 no.2
    • /
    • pp.125-130
    • /
    • 2010
  • Objectives: The current study was performed to assess the distribution of intraocular pressure (IOP) and its association with metabolic syndrome (MS) in a community. Methods: We measured IOP and MS components from 446 adults, age 20 or more years old, who reside in a community in Kyunggi Province, South Korea. We compared the level of IOP according to the number of metabolic abnormalities and between normal and abnormal metabolic components. Linear regression analyses were used to determine the relationship between IOP and metabolic components. Results: No significant difference in IOP (mean${\pm}$SE) was found between men ($12.24{\pm}2.42$) and women ($12.55{\pm}2.41$ mmHg, p > 0.1), while IOP of men tended to decrease as age increased (p for trend < 0.01). After adjusting for age, IOP of subjects with abdominal obesity in men and high blood pressure in women were significantly higher than those without abdominal obesity or high blood pressure (p < 0.05). Female subjects with MS showed significantly higher IOP than those without MS. Participants with more metabolic disturbances tended to have a greater IOP elevation with a linear trend after adjusting for age and sex. In the univariate regression analysis, age and waist circumference were significantly associated with IOP in men, but systolic and diastolic blood pressure were associated with IOP in women. In final multiple regression model, age, systolic blood pressure, and triglyceride were associated with IOP in women, and age in men. Conclusions: These findings suggest that MS and its components may be important determinants of elevated IOP.

Intraocular Pressure and Neuroprotective Effect of water and ethanol extracts from Leaves of Acer palmatum thumb. of glaucoma in DBA2/J mice (녹내장 동물모델에서 단풍나무 잎 열수 및 에탄올 추출물의 안압 및 신경세포 보호 효과)

  • Oh, Tae Woo;Park, Kwang-Il;Ma, Jin Yeul
    • Herbal Formula Science
    • /
    • v.29 no.2
    • /
    • pp.93-103
    • /
    • 2021
  • Objectives : This study was conducted to evaluate the Intraocular pressure (IOP) and retina neuroprotective effect of Acer palmatum thumb. extract in glaucoma of DBA2/J mice vivo model. Methods : The amount of change in intraocular pressure(IOP) was measured every two weeks for 30 weeks in the DBA2/J glaucoma animal model. The increased IOP were regrouping into drug treatment groups. EW and EE (1, 2 mg/㎖)extract was eye drop administered twice per day for 8 weeks. After administration of the extract, IOP was measured every 1 week at a fixed time for 8 weeks, and protein expression levels and serological changes related to retinal function were investigated. Results : The DBA2/J mice were IOP increased as time dependent, resulting in damage to the retinal function protein related in glaucoma animal model. However, administration of extracts from Leaves of Acer palmatum thumb. prevented an increase IOP, increased for Brn3α, PKCα, and OPN1SW. Additionally, the experssion of Aterocyte maker, GFAP was decreased in DBA2/J mice. Conclusions : These results demonstrate that both IOP and age can be considered in studies using DBA2/J mice and suggest that the extracts from Leaves of Acer palmatum thumb. regulating of IOP and expression of proteins related to retinal function.

Scalp Acupuncture and Master Tung Distal Points for the Treatment of Intraocular Pressure for a Patient with Borderline Glaucoma

  • Chapleau, Christopher
    • The Korean Journal of Food & Health Convergence
    • /
    • v.4 no.2
    • /
    • pp.13-16
    • /
    • 2018
  • Acupuncture has been clinically used to treat patients suffering from eye disease. It has been used in efforts to help preserve vision for those with a wide range of eye conditions including glaucoma and intraocular hypertension. High intraocular pressure (IOP) is usually associated with glaucoma and conventional treatment is focused on lowering IOP. Controlling this risk factor should help hasten the onset of glaucoma for those patents that are suspect or borderline candidates for glaucoma. In review of the limited scientific research there are not many studies that support conclusive evidence for the use of acupuncture on eye diseases and particularly glaucoma and ocular hypertension. For the information that does exist, diverse results from various interventions make it difficult to draw clear conclusions. The existing studies use different acupoints, techniques, frequencies, and durations. Individual treatment strategies according to the practitioner's subjective experience, patient condition, and the use of other complimentary and natural strategies is ideal for taking a more dynamic and wholistic approach to getting results. Until more pragmatic research models are funded and implemented, case reports can offer good examples of experiential and objective outcomes. This case report presents a 61 year old healthy female patient diagnosed with open-angle borderline glaucoma with elevated IOP. The patients IOP was successfully reduced with 12 treatments over three months using scalp electro-acupuncture and distal Master Tung points.

Effect of Tourmaline-added Eyeglass Frames on Normalization of Intraocular Pressure (토르말린이 첨가된 안경테가 안압 정상화에 미치는 영향)

  • Park, Sang-Chul;Jeong, Hye-Ri;Kwon, Jong-Moon;Lee, Gyu-Bin
    • The Korean Journal of Vision Science
    • /
    • v.20 no.4
    • /
    • pp.461-468
    • /
    • 2018
  • Purpose : Tourmaline, a natural ore material, was applied to the entire eyeglasses to observe changes in intraocular pressure (IOP), one of the factors related to human ocular metabolism. Methods : After making eyeglass frames by mixing TR-90, which is the main material of eyeglass frames and 7wt% of tourmaline, The changes of intraocular pressure before and after wearing of tourmaline spectacle frames were divided into low, middle and high groups according to the intraocular pressure in 90 normal subjects (46 men and 44 women) in their 20s. Results : Total intraocular pressure was a significantly decreased to -4.14% (p<0.000) in the right eye after wearing tourmaline frames, and significantly decreased to -6.39 % (p<0.000) and -4.64 % (p<0.017) in the High and Middle groups, respectively. Total intraocular pressure was a significantly decreased to -2.74 % (p<0.004) in the left eye, and -4.58 % (p<0.000) in the High group only showed statically significant value. Conclusion : In this study, the spectacle frame containing 7wt% tourmaline was used and it was confirmed that the intraocular pressure was significantly decreased after wearing the spectacle frame, and it became close to the average value of the normal intraocular pressure range. The results of this study showed that tourmaline, which has the effect of promoting the metabolism and blood circulation of the body, has an effect on the normalization of the intraocular pressure by attaching it to the spectacle frame.

A Study of the Variation Factors of Intraocular Pressure (안압 변동 요인에 관한 연구)

  • Kim, Sang-Moon
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.1
    • /
    • pp.131-135
    • /
    • 2008
  • Purpose: To measure and quantify the factors of intraocular pressure (IOP) variation for normal Korean youth. Methods: The IOP of normal youth 805 persons (male: 367, female: 438) were measured as a function of time and quantity for fixation, reclining posture, hard blinking, drinking water, drinking hard liquor, tobacco and coffee by using non-contact tonometer (AT555, Reichert Co.). In the case of fixation, reclining posture and hard blinking, the intraocular pressure of right and left eye were measured for 6 males and 6 females every 10 minutes during 30 minute. In the case of water, liquor, tobacco and coffee, the measurement for 4 or 5 groups (6 persons/ group) having similar IOP were done for the IOP variation of right eye. Results: The mean IOP was 15.2 mmHg for males and 15.8 mmHg for females (slightly higher than male's), respectively and the 99% of those were in the range of the normal IOP. The measured IOP was increased by fixation, reclining posture and hard blinking with males and females. The gradient of increasing slope was 0.15/0.13/0.07/0.08, 0.09/0.08/0.08/0.08 and 0.19/0.08/0.26/0.31, respectively. The IOP variation was elevated by drinking water (especially in the case of 1000 ml) and lowered in proportion to the amount of drinking by hard liquor. Cigarette smoking was associated with rise in intra ocular pressure, but was not shown a definite relation. And coffee had virtually no effect. Conclusions: Fixation, reclining posture, hard blinking and Tobacco caused a transient increase in IOP, but alcohol elicited a slight reduction in IOP overall.

  • PDF

Development of Inductive and Capacitive Type Intraocular Pressure (IOP) Sensor to Improve Sensitivity and Minimize Size (민감도 향상과 센서 소형화를 위한 자기 및 용량형 안압센서의 개발)

  • Jang, Cheol In;Shin, Kyeong-Sik;Yun, Kwang-Seok;Kim, Yong Woo;Kang, Ji Yoon;Lee, Soo Hyun
    • Journal of Sensor Science and Technology
    • /
    • v.23 no.6
    • /
    • pp.409-415
    • /
    • 2014
  • We had presented an inductive type intraocular pressure sensor (L-sensor) in previous work. The distance between a micro coil and a ferrite on the membrane was modulated by pressure, and as a result the inductance and resonant frequency were changed. However, L-sensor has some problems to implant in eyes. First problem is low sensitivity. When L-sensor was implanted in rabbit's eyes, resonant frequency of L-sensor was very hard to detect. Second problem is biocompatibility. Size of L-sensor is $6{\times}7{\times}1.2mm$. When L-sensor was implanted in the eyes, it caused the inflammation. Therefore, this study suggests an inductive and capacitive type IOP sensor (LCsensor). The sensitivity of the LC-sensor 27.3 kHz/mmHg under 60mmHg. It is much larger than 14 kHz/mmHg of the L-sensor. And the size of LC-sensor is 47% smaller than L-sensor. After 2 weeks from the implantation of LC-sensor into rabbit eyes, we measured the changes of resonant frequency of LC-sensor according to increased IOP by Balanced Salt Solution (BSS) injection. As a result, the sensitivity of LC-sensor in in vivo test is 25 kHz/mmHg. That is similar to the sensitivity of in vitro test.

A Wireless Intraocular Pressure Sensor with Variable Inductance Using a Ferrite Material

  • Kang, Byungjoo;Hwang, Hoyong;Lee, Soo Hyun;Kang, Ji Yoon;Park, Joung-Hu;Seo, Chulhun;Park, Changkun
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.13 no.4
    • /
    • pp.355-360
    • /
    • 2013
  • A wireless intraocular (IOP) pressure sensor based on micro electro mechanical system (MEMS) technology is proposed. The proposed IOP sensor uses variable inductance according to the external pressure. The proposed sensor is composed of two flexible membranes: a ferrite bottom part, an inductor, and a capacitor. The inductance of the sensor varies according to the external pressure. The resonance frequency of the sensor is also varied, and this frequency is detected using an external coil. The external coil is designed with an FR-4 printed circuit board. The feasibility of the proposed sensor structure using variable inductance to detect the external pressure is successfully demonstrated.

Retrospective study of postoperative intraocular pressure and complications in phacoemulsification combined with endoscopic cyclophotocoagulation and phacoemulsification alone in dogs

  • Sol Kim;Seonmi Kang;Youngseok Jeong;Kangmoon Seo
    • Journal of Veterinary Science
    • /
    • v.24 no.1
    • /
    • pp.16.1-16.11
    • /
    • 2023
  • Background: Long-term comparative data of phacoemulsification combined with endoscopic cyclophotocoagulation (phaco-ECP) versus phacoemulsification (phaco) alone in dogs are rare. Objectives: To investigate the effects of ECP on postoperative intraocular pressure (IOP) and complications after phaco in dogs with normal IOP. Methods: Medical records of IOP, conjunctival hyperemia, corneal edema, aqueous flare, posterior synechia, intraocular fibrin, and posterior capsule opacification (PCO) formation in 15 canine eyes that underwent phaco-ECP and 36 eyes that underwent phaco alone were evaluated retrospectively. ECP was applied when either the iridocorneal angle or the ciliary cleft was narrow or closed. Results: The IOP of the phaco-ECP group persisted within the normal range postoperatively. The phaco-ECP group had a shorter period of dorzolamide use than did the phaco group. PCO was formed earlier in the phaco-ECP group than in the phaco group. The phaco-ECP group showed more severe corneal edema than the phaco group at every follow-up visit. Posterior synechia was more severe in the phaco-ECP group than in the phaco group from two weeks until the last follow-up. Conclusions: Although ECP might cause more postoperative complications such as corneal edema and posterior synechia, it could effectively reduce the incidence of IOP increase after phaco in dogs with a high risk of postoperative glaucoma.