• 제목/요약/키워드: Intervertebral disk

검색결과 44건 처리시간 0.018초

추간판탈출증 환자에서 발생한 기능성 소화불량에 대한 한방통합치료 호전사례 (Improvement of Functional Dyspepsia with a Herniated Intervertebral Disk through Korean Medical Treatment: A Case Report)

  • 오은제;박무진;송우섭;오주희;배건희;이수경;장동진
    • 대한한방내과학회지
    • /
    • 제43권5호
    • /
    • pp.809-816
    • /
    • 2022
  • Objective: This study investigated the efficacy of using Korean medical treatments on a patient with functional dyspepsia. Methods: A 61-year-old female patient with functional dyspepsia and C/L-spine HIVD was treated with herbal medicine (Gamihyangsayukgunja-tang), acupuncture, pharmacopuncture, chuna manual therapy, and cupping therapy for 18 days. The treatment effects on the functional dyspepsia were evaluated using the Numerical Rating Scale score, Gastrointestinal Symptom Score, and Bristol Stool Scale results. Results: Following treatment, the patient showed decreases on the Numerical Rating Scale and Gastrointestinal Symptom Score and improvement on the Bristol Stool Scale. Conclusions: Korean medical treatment improved the condition of a patient with functional dyspepsia.

Alginate/PLGA 미립구에 대한 인간디스크 세포 부착 효과 (Adhesion of Human Intervertebral Disk Cells on Aiginate/PLGA Microspheres)

  • 이준희;장지욱;소정원;최진희;박종학;안식일;손영숙;민병현;강길선
    • 폴리머
    • /
    • 제33권1호
    • /
    • pp.7-12
    • /
    • 2009
  • PLGA미립구는 주사제형과 같은 형태로 조직공학적 응용에 이용할 수 있다. 본 연구에서는 미립구 제조시 에밀젼 형성조건에 대한 영향과 미립구 표면에 세포를 부착시키는 방법에 대하여 연구하였다. BSA를 함유하는 PLGA미립구는 수중유형(O/W)과 수중유중수형(W/O/W) 용매증발법을 이용하여 제조하였다. 미립구의 초기방출효과제어와 PLGA분해의 과정에서 발생되는 지연시간을 개선시키기 위하며 알긴산나트륨을 수상에 용해시켜 사용하였다. 미립구에 부착된 세포의 형태를 전자주사현미경(SEM)을 이용하여 분석하였고 PLGA미립구에 배양된 인간디스크세포의 증식은 MTT분석을 이용하였으며 이를 통하여 PLGA미립구 표면에 세포가 부착되었음을 확인하였다. 본 연구는 BSA가 함유된 알긴산/PLGA미립구를 이용하여 조직공학적 응용이 가능한 주사제형으로서의 가능성을 제안하였다.

Evaluation of Dimensions of Kambin's Triangle to Calculate Maximum Permissible Cannula Diameter for Percutaneous Endoscopic Lumbar Discectomy : A 3-Dimensional Magnetic Resonance Imaging Based Study

  • Pairaiturkar, Pradyumna Purushottam;Sudame, Onkar Shekhar;Pophale, Chetan Shashikant
    • Journal of Korean Neurosurgical Society
    • /
    • 제62권4호
    • /
    • pp.414-421
    • /
    • 2019
  • Objective : To evaluate 3-dimensional magnetic resonance imaging (MRI) of Kambin's safe zone to calculate maximum cannula diameter permissible for safe percutaneous endoscopic lumbar discectomy. Methods : Fifty 3D MRIs of 19 males and 31 females (mean, 47 years) were analysed. Oblique, axial and sagittal views were used for image analysis. Three authors calculated the inscribed circle (cannula diameter) individually, within the neural (original) and bony Kambin's triangle in oblique views, disc heights on sagittal views and root to facet distances at upper and lower end plate levels on axial views and their averages were taken. Results : The mean root to facet distances at upper end plate level measured on axial sections increased from $3.42{\pm}3.01mm$ at L12 level to $4.57{\pm}2.49mm$ at L5S1 level. The mean root to facet distances at lower end plate level measured on axial sections also increased from $6.07{\pm}1.13mm$ at L12 level to $12.9{\pm}2.83mm$ at L5S1 level. Mean maximum cannula diameter permissible through the neural Kambin's triangle increased from $5.67{\pm}1.38mm$ at L12 level to $9.7{\pm}3.82mm$ at L5S1 level. The mean maximum cannula diameter permissible through the bony Kambin's triangle also increased from $4.03{\pm}1.08mm$ at L12 level to $6.11{\pm}1mm$ at L5S1 level. Only 2% of the 427 bony Kambin's triangles could accommodate a cannula diameter of 8mm. The base of the bony Kambin's triangle taken in oblique view (3D MRI) was significantly higher than the root to facet distance at lower end plate level taken in axial view. Conclusion : The largest mean diameter of endoscopic cannula passable through "bony" Kambin's triangle was distinctively smaller than the largest mean diameter of endoscopic cannula passable through "neural" Kambin's triangle at all levels. Although proximity of exiting root to the facet joint is always taken into consideration before PELD procedure, our 3D MRI based anatomical study is the first to provide actual maximum cannula dimensions permissible in this region.

경부 CT검사 시 Kernel 값과 검사자세 변화를 통한 화질개선에 관한 연구 (A Study of Image Quality Improvement Through Changes in Posture and Kernel Value in Neck CT Scanning)

  • 김현주;정우준;조재환
    • 한국방사선학회논문지
    • /
    • 제5권2호
    • /
    • pp.59-66
    • /
    • 2011
  • 경부 CT검사 시 선속경화인공물(Beam Hardening Artifact)에 의해 제 6번 7번 경추 및 추간판 등의 질환 및 그밖에 해부학적 구조를 정확히 구분하기에 어려움이 있다. 경부 CT검사를 시행할 경우 자세의 변화방법을 적용한 견관절의 방향과 위치에 따른 영상평가 및 커널값의 변화에 따른 영상평가를 통하여 선속경화 인공물의 원인을 알아보고 가장 적절한 검사자세 및 Kernel값을 실험을 통하여 알아보고자 하였다. 경부 CT검사를 위해 내원한 환자 30명(2010년 7월1일 ~ 2010년 12월31일까지 내원한 환자)을 대상으로 Somatom Sensation 16(Siemens, Enlarge, Germany)장비를 이용하였고, workstation은 AW 4.4 version(GE, USA)을 이용하였다. 환자 자세는 견관절의 방향과 위치에 따라 세가지 자세로 변화를 주었으며 양쪽 팔을 편안하게 위치시킨 바로 누운 자세(group N), 왼쪽 팔을 거상 시킨 자세(group S) 그리고 양손을 외 선위(eversion)시켜 최대한 아래로 내리는 자세(group P)로 견관절의 방향을 변화를 주어 스캔을 시행하였고, 두 번째로 영상 재구성 방법을 이용하여 스캔 데이터에 커널값을 B10(very smooth), B20(smooth), B30(medium smooth), B40(medium), B50(medium sharp), B60(sharp), B70(very sharp)로 변화를 주어 재구성 하였다. 검사자세의 변화와 Kernel값의 변화를 주어 얻어진 영상 데이터를 이용하여 각 각의 노이즈 값 측정과 영상평가를 통하여 분석해보았다. 경부 CT검사 시 검사자세는 양손을 외선위(eversion)시켜 최대한 아래로 내리는 자세(group P)로 하며, 커널 값은 B40(medium)또는 B50(medium sharp)으로 재구성할 경우 가장 적절한 자세와 커널값으로 분석되어 임상에 적용 시 매우 유용할 것으로 사료된다.