• Title/Summary/Keyword: Interval scale

Search Result 628, Processing Time 0.028 seconds

가속수명시험을 통한 신뢰성보험요율 추정 - 합금무계목인발강관의 사례를 중심으로 -

  • Hong, Yeon-Ung;Jeong, Yeong-Hun
    • 한국데이터정보과학회:학술대회논문집
    • /
    • 2004.04a
    • /
    • pp.1-5
    • /
    • 2004
  • In this paper, we calculate the premium rate of reliability insurance policy for T11 composite metreial under the assumption of Weibull physics of failure and Arrhenius law. We also describe the performance factors which have an effect on failure characteristics of wiper motors. The maximum likelihood estimates of shape parameter and scale parameter are obtained by using interval censored real data of sample sizes 6 using MINITAB.

  • PDF

PARALLEL OPTIMAL CONTROL WITH MULTIPLE SHOOTING, CONSTRAINTS AGGREGATION AND ADJOINT METHODS

  • Jeon, Moon-Gu
    • Journal of applied mathematics & informatics
    • /
    • v.19 no.1_2
    • /
    • pp.215-229
    • /
    • 2005
  • In this paper, constraint aggregation is combined with the adjoint and multiple shooting strategies for optimal control of differential algebraic equations (DAE) systems. The approach retains the inherent parallelism of the conventional multiple shooting method, while also being much more efficient for large scale problems. Constraint aggregation is employed to reduce the number of nonlinear continuity constraints in each multiple shooting interval, and its derivatives are computed by the adjoint DAE solver DASPKADJOINT together with ADIFOR and TAMC, the automatic differentiation software for forward and reverse mode, respectively. Numerical experiments demonstrate the effectiveness of the approach.

An investigation on ignition ability of the repetitive sparks (반복점화방식의 점화능력에 관한 연구)

  • 조경국;정인석
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.10 no.3
    • /
    • pp.60-65
    • /
    • 1988
  • The ignition characteristics of repetitive electric sparks into a quiescent acetylene-air premixture and LPG-argon-air premixture was investigated by using a home-made Repetitive-Spark-Generator(RSG) to elucidate the effect of fuel burning velocity to ignition ability of RSG. Results show that the optimum spark delay time interval is strongly related with fuel burning velocity, or implicitly with characteristic reaction time scale of each fuel.

  • PDF

Empirical Bayes Inferences in the Burr Distribution by the Bootstrap Methods

  • Cho, Kil-Ho;Cho, Jang-Sik;Jeong, Seong-Hwa;Shin, Jae-Seock
    • Journal of the Korean Data and Information Science Society
    • /
    • v.15 no.3
    • /
    • pp.625-632
    • /
    • 2004
  • We consider the empirical Bayes confidence intervals that attain a specified level of EB coverage for the scale parameter in the Burr distribution under type II censoring data. Also, we compare the coverage probabilities and the expected confidence interval lengths for these confidence intervals through simulation study.

  • PDF

A Note on a New Two-Parameter Lifetime Distribution with Bathtub-Shaped Failure Rate Function

  • Wang, F.K.
    • International Journal of Reliability and Applications
    • /
    • v.3 no.1
    • /
    • pp.51-60
    • /
    • 2002
  • This paper presents the methodology for obtaining point and interval estimating of the parameters of a new two-parameter distribution with multiple-censored and singly censored data (Type-I censoring or Type-II censoring) as well as complete data, using the maximum likelihood method. The basis is the likelihood expression for multiple-censored data. Furthermore, this model can be extended to a three-parameter distribution that is added a scale parameter. Then, the parameter estimation can be obtained by the graphical estimation on probability plot.

  • PDF

Interobserver and Intraobserver Reliability of Sub-Axial Injury Classification and Severity Scale between Radiologist, Resident and Spine Surgeon

  • Lee, Woo Jin;Yoon, Seung Hwan;Kim, Yeo Ju;Kim, Ji Yong;Park, Hyung Chun;Park, Chon Oon
    • Journal of Korean Neurosurgical Society
    • /
    • v.52 no.3
    • /
    • pp.200-203
    • /
    • 2012
  • Objective : The sub-axial injury classification (SLIC) and severity scale was developed to decide whether to operate the cervical injured patient or not, but the reliability of SLIC and severity scale among the different physicians was not well known. Therefore, we evaluated the reliability of SLIC among a spine surgeon, a resident of neurosurgery and a neuro-radiologist. Methods : In retrograde review in single hospital from 2002 to 2009 years, 75 cases of sub-axial spine injured patients underwent operation. Each case was blindly reviewed for the SLIC and severity scale by 3 different observers by two times with 4 weeks interval with randomly allocated. The compared axis was the injury morphology score, the disco-ligamentous complex score, the neurological status score and total SLIC score; the neurological status score was derived from the review of medical record. The kappa value was used for the statistical analysis. Results : Interobserver agreement of SLIC and severity scale was substantial agreement in the score of injury morphology [intraclass correlation (ICC)=0.603] and total SLIC and severity sacle (ICC value=0.775), but was fair agreement in the disco-ligamentous complex score (ICC value= 0.304). Intraobserver agreements were almost perfect agreement in whole scales with ICC of 0.974 in a spine surgeon, 0.948 in a resident of neurosurgery, and 0.963 in a neuro-radiologist. Conclusion : The SLIC and severity scale is comprehensive and easily applicable tool in spine injured patient. Moreover, it is very useful tool to communicate among spine surgeons, residents of neurosurgery and neuro-radiologists with sufficient reproducibility.

Evaluation of the Korean Version of Physical Activity Scale for the Elderly (K-PASE) (한국판 노인 신체활동 측정도구(Korean version of Physical Activity Scale for the Elderly: K-PASE)의 평가)

  • Choe, Myoung-Ae;Kim, Jeung-Im;Jeon, Mi-Yang;Chae, Young-Ran
    • Women's Health Nursing
    • /
    • v.16 no.1
    • /
    • pp.47-59
    • /
    • 2010
  • Purpose: The purpose of this study was to develop a Korean version of Physical Activity Scale for the Elderly (K-PASE) from PASE and to evaluate the validity and reliability of the K-PASE. This scale was originally developed by Washburn et al. (1993). A valid and reliable physical activity scale for the elderly is needed to assess accurately physical activity of the elderly, because there has been no valid and reliable physical activity scale for the elderly in Korea. Methods: The K-PASE was developed from PASE through linguistic validation and cultural adaptation for use with this population. Convenient sampling was used to recruit participants. Reliability was evaluated by conducting the test-retest and convergent validity was evaluated by Pearson correlation. Results: Test-retest reliability, assessed over a 2 week interval, was r=.94. Convergent validity was established by correlating the KPASE scores between related variables which were the Tokyo Metropolitan Institute of Gerontology Index of Competence (TMIG-IC) and hand-grip strength. Scores of the K-PASE had a low significant correlation with TMIG-IC (r=.246, p<.001), and hand-grip strength (r=.251, p<.001). The mean score of physical activity of Korean elderly assessed by the K-PASE was 96.5. Conclusion: We conclude that the K-PASE is a reliable and valid instrument to assess physical activity for Korean elderly.

Comparison Study with Pain Assessment Tools of Pain Measurement in Children for Intravenous Catheter Placement in the Computed Tomography (CT 검사에서 소아 환자의 정맥 카데터 삽입 통증에 대한 측정 도구 비교)

  • Kweon, Dae-Cheol;Jang, Keun-Jo
    • The Journal of the Korea Contents Association
    • /
    • v.8 no.2
    • /
    • pp.205-212
    • /
    • 2008
  • Needle phobia of medical devices is a significant problem in children patients. We conducted study in 130 pediatric patients aged $8{\sim}13$(mean age 10.5) who had venipuncture performed in a computed tomography. This review aims to explore the research available relating to three commonly used pain rating scales of children, the visual analogue scale(VAS), numeric pain rating scale(NPRS) and Wong-Baker faces pain scale(WBFPS) with scores. Its validity is supported by a strong positive correlation with the three-pain rating scales(correlations ranging from 0.70 to 0.92) measure in children. There were no significant differences between the means on the VAS and either of the pain rating scales. It has the advantage of being suitable for use with the most widely used metric for scoring($0{\sim}10$), and conforms closely to a linear interval scale. These scales presented moderate to good correlation and moderate agreement, sufficient for valid use in children. All three pain-rating scales are valid, reliable and appropriate for use in intravenous catheter placement.

Computerized Sunnybrook facial grading scale (SBface) application for facial paralysis evaluation

  • Jirawatnotai, Supasid;Jomkoh, Pojanan;Voravitvet, Tsz Yin;Tirakotai, Wuttipong;Somboonsap, Natthawut
    • Archives of Plastic Surgery
    • /
    • v.48 no.3
    • /
    • pp.269-277
    • /
    • 2021
  • Background The Sunnybrook facial grading scale is a comprehensive scale for the evaluation of facial paralysis patients. Its results greatly depend on subjective input. This study aimed to develop and validate an automated Sunnybrook facial grading scale (SBface) to more objectively assess disfigurement due to facial paralysis. Methods An application compatible with iOS version 11.0 and up was developed. The software automatically detected facial features in standardized photographs and generated scores following the Sunnybrook facial grading scale. Photographic data from 30 unilateral facial paralysis patients were randomly sampled for validation. Intrarater reliability was tested by conducting two identical tests at a 2-week interval. Interrater reliability was tested between the software and three facial nerve clinicians. Results A beta version of the SBface application was tested. Intrarater reliability showed excellent congruence between the two tests. Moderate to strong positive correlations were found between the software and an otolaryngologist, including the total scores of the three individual software domains and composite scores. However, 74.4% (29/39) of the subdomain items showed low to zero correlation with the human raters (κ<0.2). The correlations between the human raters showed good congruence for most of the total and composite scores, with 10.3% (4/39) of the subdomain items failing to correspond (κ<0.2). Conclusions The SBface application is efficient and accurate for evaluating the degree of facial paralysis based on the Sunnybrook facial grading scale. However, correlations of the software-derived results with those of human raters are limited by the software algorithm and the raters' inconsistency.

Surveying for Monitoring Topographic Changes of Tidal Zone (조간대 지형변화측량의 방법과 문제)

  • 이창경;진준호
    • Proceedings of the Korean Society of Surveying, Geodesy, Photogrammetry, and Cartography Conference
    • /
    • 2004.04a
    • /
    • pp.553-558
    • /
    • 2004
  • Periodic profiling by level is a conventional method for monitoring topographic changes in a specific part of tidal zone. Periodic aerial photographs are used for monitoring topographic change of broad tidal zone area. In this study, spot heights at interval of 50m on 5 profiling lines were leveled periodically for precise monitoring topographic change of tidal zone. For monitoring broad topographic change of tidal zone, aerial photographs were also taken by film camera loaded on pilotless helicopter periodically Periodic profiling shows the change of heights on the lines well. On the other hand, aerial photographs taken by film camera loaded on pilotless helicopter have some problems to detect topographic change of tidal zone precise. Because the scale and incline of the photographs were not same, it is hard to compare them. Therefore, for more precise monitoring of topographic changes in tidal zone, it is need to take aerial pictures with same scale and same incline.

  • PDF