• Title/Summary/Keyword: Interval scale

Search Result 628, Processing Time 0.026 seconds

The Toolpath Generation for Free-Formed Surface with the Flat Endmill (플랫 앤드밀을 이용한 자유곡면 가공경로 생성)

  • Lee, Gun-Young;Nam, Won-Woo;Lee, Sang-Jo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.18 no.4
    • /
    • pp.104-111
    • /
    • 2001
  • The toolpath generation for 3D shaped parts with adaptive isocurve is more precise than existing methods, and the machining time can be reduced. Whether adaptive isocurves are inserted or not is determined by the surface shape, but the number of curves inserted and the total path length vary with initial step lengths. In this paper, therefore, by introducing the concept of the scale factor into the initial path interval ; toolpath was regenerated.

  • PDF

Higher Order Moments of Record Values From the Inverse Weibull Lifetime Model and Edgeworth Approximate Inference

  • Sultan, K.S.
    • International Journal of Reliability and Applications
    • /
    • v.8 no.1
    • /
    • pp.1-16
    • /
    • 2007
  • In this paper, we derive exact explicit expressions for the triple and quadruple moments of the lower record values from inverse the Weibull (IW) distribution. Next, we present and calculate the coefficients of the best linear unbiased estimates of the location and scale parameters of IW distribution (BLUEs) for different choices of the shape parameter and records size. We then use the higher order moments and the calculated BLUEs to compute the mean, variance, and the coefficients of skewness and kurtosis of certain linear functions of lower record values. By using the coefficients of the skewness and kurtosis, we develop approximate confidence intervals for the location and scale parameters of the IW distribution using Edgeworth approximate values and then compare them with the corresponding intervals constructed through Monte Carlo simulations. Finally, we apply the findings of the paper to some simulated data.

  • PDF

A Study on the Standard Durable Years of Pipe Framed Greenhouses (파이프 골조 온실 구조물의 표준내용연수 연구)

  • 남상운
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.43 no.1
    • /
    • pp.96-101
    • /
    • 2001
  • In designing the greenhouse structures, snow and wind loads must be estimated on the basis of the probability of occurrence of snow or wind storms of a given intensity. The recurrence interval chosen depends on the standard durable years and safety factors of the greenhouse. This study was carried out to find the standard durable years of pipe framed greenhouses. Bend test for metallic materials was conducted on samples of galvanized steel pipes being used in greenhouse frames. A secular change of collapse loads and flexural rigidity for galvanized steel pipes were analyzed with the parts buried in the ground and exposed in the atmosphere. From those experimental results and corrosion rate of galvanized film, the standard durable years for pipe framed greenhouses are estimated as follows ; the small scale pipe houses of movable type is 7∼8 years and the large scale pipe houses of fixed type is 14∼15 years.

  • PDF

A Study on the Size Designation of Foundation Garments (화운데이션의류의 치수규격에 관한 연구)

  • Lee Jun-Ok;Seong Hwa-Kyung;Choi Hei-Sun;Yi Kyong-Hwa
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.30 no.6 s.154
    • /
    • pp.892-903
    • /
    • 2006
  • This study was to carry out interview and survey of currently marketed foundation garment, focusing on manufacturers, on the basis of data of Year 2004 SIZE KOREA in 2004, to re-establish suitable age range and standard size, to simplify size interval scale and size system and to revise the standard for consumers' easy understanding and availability; The findings of this study are as follows. 1. Considering the age, in which a bra is worn, has reduced socially, the applicable age range was expanded into $8{\sim}80$ years old, which was divided into for junior and for adult. 2. For bra size, the standard title changed into the foundation garments size standard, in which girdle and bodysuit were included. 3. Basic physical parts for establishing for bra size are underbust and bust. Interval scale of under bust and bust was 5cm and 2.5cm, respectively. And basic physical parts are waist and hip girth for girdle, and underbust, bust, and hip girth for bodysuit. 4. For bra size, underbust girth was applied together with bra-cup size without 'cm' unit. For bra-cup size, difference between underbust and bust was represented as English alphabet. In other words, AAA means that difference between under bust and bust is 5cm. AA, A, B, C and D means that the difference are 7.5cm, 10cm, 12.5cm, 15cm and 17.5cm. 5. For girdle size, waist girth was applied together with hip girth without 'cm' unit. And for bodysuit size, underbust girth was applied together with cup size like bra size, and English alphabet represented hip girth range.

Bearing Capacity Study for Small-Scale Testing of Rotary Pile with Helix Plate (축소모형 로타리 파일의 나선날개에 따른 지지성능에 관한 연구)

  • Shin, Eun-Chul;Kim, Kyeong-Sig;Moon, Hyeong-Rok
    • Journal of the Korean Geosynthetics Society
    • /
    • v.15 no.1
    • /
    • pp.37-46
    • /
    • 2016
  • Rotary pile consists a single or multiple helix plate and it is installed into the ground using the rotation of the helix plate. Rotary pile in soft ground is able to be supported by pile shaft and helix plate. When the pile is installed into hard layer relatively, the end bearing capacity is possible to be increased by the lower helix plate. In this paper, small-size rotary piles were manufactured with using steel pipe which is reduced to 1/5 size of the rotary pile on the construction field. Pile load test was carried out on the foundation soil which was formed by weathered soft soil. The bearing capacity of small-scale piles depends on the number of helix plate, the length of plate diameter, and an interval of plates, respectively. The bearing capacity of pile increases about 40% with 3 helix plate and it is also confirmed that the bearing capacity is improved about 10% as the increment of plate interval.

Chuna Manual Therapy for Stroke: A Systematic Review and Meta-analysis (뇌졸중의 추나요법에 대한 체계적 문헌 고찰)

  • Kim, Mi-Kyung;Han, Chang-Ho
    • The Journal of Churna Manual Medicine for Spine and Nerves
    • /
    • v.14 no.2
    • /
    • pp.15-28
    • /
    • 2019
  • Objectives : This study aimed to systematically and comprehensively review controlled clinical trials on the effectiveness and safety of Chuna Manual Therapy for stroke. Methods : By October 7, 2019, three core databases and three domestic databases were searched. Seven major academic journals on the related field were also hand-searched. Methodological quality of the included studies was evaluated using the Cochrane risk of bias tool. Meta-analysis was conducted and the quality of its evidence was assessed using the GRADE methodology. Results : Five articles met the eligibility criteria. The results of most of included studies were in favor of Chuna Manual Therapy. No study described any adverse events during or after the clinical trials. Meta-analysis of three eligible studies showed that the pre- and post-treatment scores on the Modified Barthel Index (mean difference 8.00, 95% confidence interval 0.26 to 15.74) and Berg Balance Scale (mean difference 3.57, 95% confidence interval 0.64 to 6.51) of the Chuna-treated group were significantly different, but only marginally higher than those of the non-treatment group. Thus, the level of evidence gathered from these studies was assessed to be low. Conclusions : Based on current available evidence, any confirmative conclusions cannot be made on the effectiveness and safety of Chuna Manual Therapy for stroke because of the small sample size, low methodological quality, presence of statistical heterogeneity, and missing safety information. More rigorously designed large-scale multi-center studies are needed to establish more specific and credible evidence to support or oppose the use of Chuna Manual Therapy for stroke.

Limitation Analysis on Estimation of SS Pollutant Load using Korean Ministry of Environment's 8-Day Interval Flow and Water Quality data (환경부 8일 유량‧수질 자료를 이용한 SS오염부하량 산정의 한계점 분석)

  • Kim, Taegoo;Yoo, Jongwon;Cho, Hyung-ik;Han, Jeongho;Lee, Dong Jun;Jung, Younghun;Yang, Jae E;Lim, Kyoung Jae
    • Journal of Korean Society on Water Environment
    • /
    • v.32 no.2
    • /
    • pp.149-162
    • /
    • 2016
  • In recent years, there has been demand for precise estimations of pollutant loads on nationwide scale for the development of appropriate site specific (watershed specific) policies to reduce the negative impact of pollutant loads. River flow data and water quality data that were previously collected by various research institutes and universities for specific research purposes for a limited period was utilized in this study. However, only TMDL 8-day interval flow and water quality data were available in national scale. Three watersheds were selected and pollutant loads were calculated by two methods i.e., Numeric Integration (NI) method and Soil and Water Assessment Tool (SWAT). Subsequently, the results were compared to determine the appropriate method for monitoring nonpoint source networks nationwide. The SWAT model was calibrated and its estimated daily flow data were used in the NI method with estimated sediment data for 8-day monitoring data for three watersheds. The results indicated that the quantity of pollutant loads estimated with the NI and SWAT are different to some degrees especially during the summer season for all the three study watersheds. Thus, more frequent sampling of water quality is needed for nonpoint source pollutant estimation.

Color evolution of HBC 722 in the post-outburst phase

  • Baek, Giseon;Pak, Soojong;Green, Joel D.;Lee, Jeong-Eun;Bae, Kyoung Min;Jeon, Yiseul;Choi, Changsu;Im, Myungshin;Meschiari, Stefano
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.38 no.2
    • /
    • pp.70.2-70.2
    • /
    • 2013
  • We present collections of optical photometry for a pre-main sequence star HBC 722. It showed large amplitude optical outburst (${\Delta}V=4.7$ mag) in 2010 and classified as a FU Orionis type object. We have been observing HBC 722 from 2011 April to 2013 May, using Camera for QUasars in EArly uNiverse (CQUEAN) attached to the 2.1 m Otto Struve telescope at the McDonald Observatory. Time-series monitoring data (minute-scale interval) were obtained in SDSS r, i and z bands to see short-scale behaviors as well as trace the long-term brightness changes after the eruption in 2010. Interestingly, it started to brighten from 2011 early summer and became brighter than the first outburst peak in our 2013 May observation. We expect that the recovering phase would result from re-increase of disk accretion rate, might attribute to distinctive short-scale color features. In this presentation, we report long- and short-timescale optical behaviors of HBC 722 in the post-outburst phase.

  • PDF

A Study of stability in ratings for clothing and their woven fabrics (의복과 그 직물에 대한 평가의 재현성 차이에 관한 연구)

  • 유경숙
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.25 no.3
    • /
    • pp.560-568
    • /
    • 2001
  • The aim of the present study was to measure intra-individual consistency in clothing and fabric evaluation and to examine its relation to the ratings. A sample of 93 female and 97 male university students rated clothing of 4 styles of daytime wear and 2 fabrics on 15 pairs of polar adjectives twice in 7-days interval. Correlation coefficients between the two ratings for each subject, intra-individual consistency in the evaluation, ranged from -0.12 to 0.89 and mean coefficient was 0.63 of female and -0.01 to 0.78 and mean coefficient was 0.54 of male. Based on the coefficients, the subjects were classified into three groups: high, medium, and low intra-individual consistency. Analysis of variance of mean ratings by the three groups revealed that significant difference existed in 24% of female and 23% of male in 90 combinations of 6 clothing and 15 semantic differential scales. Female of subjects with high intra-individual consistency were most likely definite to evaluate clothing, whereas the ones with low were least. But male subjects were not definite. Mean correlation coefficients for style evaluation subscales of female was 0.39, but male was 0.44. Among the semantic differential scales, high stability in the two ratings was observed for the synthetic clothing evaluation. Correlation coefficients for each clothing obtained from the mean score of the subjects in each semantics differential scale were around 0.98, including that the mean scores of the subjects in each scale could yield excellent stability in clothing evaluation.

  • PDF

Sleep Quality Evaluation Using Self-Reported Questionnaires in Patients with Burning Mouth Syndrome

  • Jin, Jung-Yong;Lee, Kyung-Eun;Suh, Bong-Jik
    • Journal of Oral Medicine and Pain
    • /
    • v.41 no.4
    • /
    • pp.188-194
    • /
    • 2016
  • Purpose: Burning mouth syndrome (BMS) is ambiguous and enigmatic oral condition. Sleep disturbance is one of the most prevalent complaints of patients with chronic pain. The aim of this study was to estimate general sleep characteristics and propensity in patients with BMS. Methods: A total of thirty BMS patients and thirty healthy control subjects were investigated. Self-reported measures of sleep quality were conducted using two widely used methods; the Pittsburgh Sleep Quality Index (PSQI) and Epworth Sleepiness Scale (ESS). Data were analyzed with one-way ANOVA, chi-square, Fisher's exact test, Kruskal-Wallis test, Holm method with 95% confidence interval and p<0.05 significant level. Results: BMS patients showed more poor sleepers than those in control subjects in both ESS and PSQI test. BMS patients also showed statistically significant poorer sleep quality compared with control subjects in both test. When BMS group were divided into three groups on the basis of numeric rating scale, the higher score subjects had, the more mean rank they had in the PSQI. Conclusions: BMS patients showed up poor sleep characteristics and propensity than control group, and they also showed the more severe the pain was, the worse the sleep quality was.