• Title/Summary/Keyword: Interruption Time

Search Result 289, Processing Time 0.027 seconds

A longitudinal study of the stress factors of parents between psychological maladjustment and the risk of school interruption in multicultural adolescents: The Application of Autoregressive Cross-lagged Model (부모의 스트레스와 다문화청소년의 심리적 부적응, 학업중단위험 간 종단적 인과관계: 자기회귀교차지연모형 적용)

  • Lee, Hyoung-Ha
    • Journal of Digital Convergence
    • /
    • v.19 no.6
    • /
    • pp.373-385
    • /
    • 2021
  • In this study, the Korea Youth Policy Institute applied a self-registering model to verify the patterns of parental stress, multicultural youth psychological maladjustment, and interdependence between three factors by using five-point-time data tracked from middle school to high school. According to the analysis, First, Parent' stress at the time of the five surveys had a significant positive effect on the psychological maladjustment and the risk of academic interruption of multicultural adolescents at that point. Second, the psychological maladaptation of multicultural adolescents at the time of the previous five surveys had a significant positive effect on the risk of academic interruption at that point. Based on these analysis results, various support measures were proposed to cope with the stress of multicultural youth parents, and policy alternatives were proposed to prevent the risk of academic interruption by reducing the psychological maladjustment of multicultural youth.

Evaluation of Reliability Worth Considering Sustained Interruptions and Voltage Sags (영구정전과 순간전압강하를 고려한 신뢰도 비용 평가)

  • Lee, Hee-Tae;Moon, Jong-Fil;Seol, Kyu-Hwan;Yun, Sang-Yun;Kim, Jae-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.5
    • /
    • pp.13-20
    • /
    • 2008
  • Power quality problems such as momentary interruptions and voltage sags do not great influence on loads at past. However, the interests in power quality problems increase as the use of sensitive loads with microprocessor like computers increases recently. Accordingly, power system reliability research focusing to sustained interruption and momentary interruption partially needs more accurate evaluation methods including momentary and instantaneous problems. That is, many sensitive loads being tripped by voltage sags result in interruption costs. In this paper, new reliability worth evaluation method is presented considering voltage sags. We calculated the magnitude of voltage sags using fault studies and the duration of voltage sags using the trip time of protective relays for each fault. Moreover, we includes the customer interruption cost resulted from sensitive load trip by voltage sags. Through case studies, we evaluate the effects of voltage sags for permanent faults.

Analysis of Ignition Time/Current Characteristics and Energy when Series Arc-Fault Occurs at Rated 220 V (220 V 직렬 아크고장발생 시 점화 시간/전류 특성 및 에너지 분석)

  • Ko, Won-Sik;Moon, Won-Sik;Bang, Sun-Bae;Kim, Jae-Chul
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.8
    • /
    • pp.1184-1191
    • /
    • 2013
  • Probability of ignition due to arc-fault and energy of the arc-fault for the case of applying serial arc-fault interruption time of 120 V defined in UL 1699 to the voltage of 220 V of domestic condition and also for the case of applying it to the HIV wire type are analyzed. It has been confirmed that when the arc-fault occurs under 5 A, 10 A, and 20 A. Probability of ignition for the three different current conditions is 0.74(74%), 0.48(48%), and 0.32(32%) respectively for respective interruption time within 1 sec, 0.4 sec, and 0.2 sec. We discover that when we apply the same arc interruption time for 120 V defined in UL 1699 to the domestic environment of 220 V. The probability of ignition increases from 1.5% for 120 V condition to as much as 74% for 220 V condition. Conclusively, if we apply the standard for the serial arc-fault interruption time defined in UL 1699 for 120 V to the domestic condition of 220 V, the fire prevention effect of electric fire due to arc-fault equal to that of UL standard of 120 V can not be achieved.

Estimation of Interruption Capability of a Serial-Hybrid Type Model Gas Circuit Breaker (직렬-복합소호형 모델 가스차단기의 차단성능평가)

  • 송기동;정진교;박경엽
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.53 no.9
    • /
    • pp.538-544
    • /
    • 2004
  • This paper presents the interruption capability of serial-hybrid type GCB (gas circuit breaker) compared with that of puffer type. First a puffer type model interrupter which has the stroke length of 80 mm has been designed and manufactured. And also, a serial-hybrid type interrupter which has the same design parameters as the puffer type interrupter except the serially arranged thermal-expansion chamber and puffer cylinder has been fabricated. Using a simplified synthetic test facility, the critical interruption capabilities of the two GCBs have been estimated. The critical di/dt, the critical dV/dt of ITRV (initial transient recovery voltage) and the minimum arcing time of the puffer type model GCB were 10.7 A/${\mu}\textrm{s}$, 5.5 kV/${\mu}\textrm{s}$, and 15.0 ms respectively. In the case of serial-hybrid type model GCB, each of the values was 16.6A/${\mu}\textrm{s}$, 11.5 kV/${\mu}\textrm{s}$ and 13.0 ms. As a conclusion of this work, it has been quantitatively confirmed that the hybrid type interrupter can obtain the sufficient interruption capability at the operating force which is so low that puffer type interrupter has not the interruption capability.

Evaluation Method I of the Small Current Breaking Performance for SF(sub)6-Blown High-Voltage Gas Circuit Breakers (초고압 $SF_6$ 가스차단기의 소전류 차단성능 해석기술 I)

  • 송기동;이병운;박경엽;박정후
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.50 no.7
    • /
    • pp.331-337
    • /
    • 2001
  • With the increasing reliability of analysis schemes and the dramatically increased calculating speed, the computer simulation has become and indispensable process to predict the interruption capacity of circuit breakers. Generally, circuit breakers have to possess both the small current and large current interruption abilities and the circuit breaker designers need to evaluate its capacities to save the time and the expense. The analysis of small current and the large current interruption performances have been considered separately because the phenomena occurring in a interrupter are quite different. To analyze the dielectric recovery after large current interruption many physical phenomena such as heat transfer, convection and arc radiation, the nozzle ablation, the ionization of high temperature SF(sub)6 gas, the electric and themagnetic forces and so forth mush be considered. However, in the analysis of small current interruption performance only the cold gas flow analysis needs to be carried out because the capacitive current is to small that the influence from the current can be neglected. In this paper, an empirical equation which is obtained from a series of tests to estimate the dielectric recovery strength has been applied to a real circuit breaker. The results of analysis have been compared with the test results and the reliability has been investigated.

  • PDF

Optical Properties of InAs Quantum Dots Grown by Using Arsenic Interruption Technique

  • Choe, Yun-Ho;Kim, Hui-Yeon;Ryu, Mi-Lee;Jo, Byeong-Gu;Kim, Jin-Su
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.08a
    • /
    • pp.268-268
    • /
    • 2011
  • GaAs (001) 기판에 MBE를 이용하여 자발형성법으로 성장한 InAs 양자점(QDs: quantum dots)의 광학적 특성을 PL (photoluminescence)과 TRPL (time-resolved PL)을 이용하여 분석하였다. InAs 양자점 성장 동안 In 공급은 계속하면서 As 공급을 주기적으로 차단과 공급을 반복하면서 성장하였다. As 차단과 공급을 1초, 2초, 그리고 3초씩 하면서 InAs 양자점을 성장하였다. 기준시료는 In과 As 공급을 중단하지 않고 20초 동안 성장하였다. As interruption mode로 성장한 시료들의 QD density는 기준시료에 비해 증가하였으며, size distribution도 기준시료에 비해 향상되었다. 기준시료와 비교하였을 때, As interruption mode로 성장한 시료들의 PL 피크는 적색이동 (red-shift)를 보였으며, PL 세기는 2배 이상 증가하였다. PL 소멸곡선은 파장이 증가함에 따라 점차 느려지다가 PL 피크에서 가장 느린 소멸을 보인 후 다시 점차 빠르게 소멸하였다. 시료의 온도를 10 K에서 60 K까지 증가하였을 때 PL 피크 에너지는 변하지 않았으며, PL 소멸시간은 서서히 증가함을 보였다. 온도를 더 증가하였을 때 PL 피크 에너지는 적색이동 하였으며 PL 소멸시간도 빠르게 감소함을 보였다. As interruption mode로 성장한 양자점 시료의 구조적 특성 변화에 의한 광학적 특성 변화를 확인하였다.

  • PDF

The Investment Scheme of the Maintenance Planning with Limited Investment Budget in the Distribution Systems for Minimizing the Interruption Cost (제한된 투자 예산으로 정전비용 최소화를 위한 배전계통 유지보수 계획의 투자 방안)

  • Hwang, Won-Il;Kim, Kyu-Ho;Kim, Hong-Rae;Song, Kyung-Bin
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.8
    • /
    • pp.1-7
    • /
    • 2010
  • The reliability of a power system has close relationship with the maintenance of the distribution systems. This paper presents the method of the maintenance planning of the distribution systems by minimizing the interruption cost. The interruption cost for the equipment failures is formulated using time varying failure rate and minimized by optimization of the object function. The proposed method provides the priority list for the investment of the maintenance subject to the limited investment budget by the economic analysis. In order to test the proposed method, the modified distribution system of a rural area is introduced for the testing system. Test results show that the proposed method is good enough by evaluating the improvement of the reliability of the power system.

The Mediation Effect of the Work-Family Spillover between Full-time Married Working Women's Inefficient Working Culture and Career Interruption Intention (비효율적 업무문화와 경력단절의도와의 관계에서 일-가정 전이의 매개효과: 전일제 기혼 여성근로자를 대상으로)

  • Park, Cheong-Yeul;Shon, Young-Mi;Shin, Kyu-Lee
    • The Journal of the Korea Contents Association
    • /
    • v.15 no.8
    • /
    • pp.280-292
    • /
    • 2015
  • The current study examines the mediation effect of the work-family spillover between full-time married working women's inefficient working culture and career interruption intention. The mediation effect is tested by classifying the work-family spillover effect into two subfactors: the work-family conflict and the work-family facilitation. For this purpose, we sampled 281 full-time married working women aged between 30 and 50s and conducted a hierarchical regression analysis. The main results are as follows: both work-family conflict and work-family facilitation play the role of partial mediation. This finding implies that it is necessary to carefully examine the effects of subfactors for work-family spillover to married working women's career interruption.

Current Limiting and Discharge Characteristics of High Tc Superconductive Fuse (고온 초전도 퓨즈의 한류 및 방전 특성)

  • Choi, Hyo-Sang
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.17 no.6
    • /
    • pp.673-677
    • /
    • 2004
  • We present the basic properties of a superconductive fuse (SF) based on YBCO/Au films. The SF consists of YBCO stripes covered with Au layers for current shunt. The fault current was limited to a designed value in less than 0.4 msec by resistance development in YBCO/Au upon quenching. This enabled the SF to transfer small fault power and the suppressed current was sustained for more than 0.5 msec while Au layer melting and arcing. The arcing time was less than 2.5 msec, that is short enough to do self-interruption. Under the source voltage of 100 $V_{rms}$, the longer the duration time of fault current was, the shorter its discharge time was. The duration time of fault current and its discharge time were reduced by increased voltages in the range of 200 - 300 $V_{rms}$. We thought that this was because the quench propagation was limited by local melting generated with higher voltage.age.

Dynamic Island Partition for Distribution System with Renewable Energy to Decrease Customer Interruption Cost

  • Zhu, Junpeng;Gu, Wei;Jiang, Ping;Song, Shan;Liu, Haitao;Liang, Huishi;Wu, Ming
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.6
    • /
    • pp.2146-2156
    • /
    • 2017
  • When a failure occurs in active distribution system, it will be isolated through the action of circuit breakers and sectionalizing switches. As a result, the network might be divided into several connected components, in which distributed generations could supply power for customers. Aimed at decreasing customer interruption cost, this paper proposes a theoretically optimal island partition model for such connected components, and a simplified but more practical model is also derived. The model aims to calculate a dynamic island partition schedule during the failure recovery time period, instead of a static islanding status. Fluctuation and stochastic characteristics of the renewable distributed generations and loads are considered, and the interruption cost functions of the loads are fitted. To solve the optimization model, a heuristic search algorithm based on the hill climbing method is proposed. The effectiveness of the proposed model and algorithm is evaluated by comparing with an existing static island partitioning model and intelligent algorithms, respectively.