• 제목/요약/키워드: Interpolation Characteristics

검색결과 331건 처리시간 0.022초

Development of FAMD Code to Calculate the Fluid Added Mass and Damping of Arbitrary Structures Submerged in Confined Viscous Fluid

  • Koo, Gyeong-Hoi;Lee, Jae-Han
    • Journal of Mechanical Science and Technology
    • /
    • 제17권3호
    • /
    • pp.457-466
    • /
    • 2003
  • In this paper, the numerical finite element formulations were derived for the linearized Navier-Stokes' equations with assumptions of two-dimensional incompressible, homogeneous viscous fluid field, and small oscillation and the FAMD (Fluid Added Mass and Damping) code was developed for practical applications calculating the fluid added mass and damping. In formulations, a fluid domain is discretized with C$\^$0/-type quadratic quadrilateral elements containing eight nodes using a mixed interpolation method, i.e., the interpolation function for the velocity variable is approximated by a quadratic function based on all eight nodal points and the interpolation function for the pressure variable is approximated by a linear function based on the four nodal points at vertices. Using the developed code, the various characteristics of the fluid added mass and damping are investigated for the concentric cylindrical shell and the actual hexagon arrays of the liquid metal reactor cores.

ADI 보간 알고리듬을 적용한 Color Space Converter 칩 설계에 관한 연구 (A study of the color De-interlacing ASIC Chip design adopted the improved interpolation Algorithm for improving the picture quality using color space converter.)

  • 이치우;박노경;진현준;박상봉
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2001년도 하계종합학술대회 논문집(4)
    • /
    • pp.199-202
    • /
    • 2001
  • A current TV-OUT format is quite different from that of HDTY or PC monitor in encoding techniques. In other words, a conventional analog TV uses interlaced display while HDTV or PC monitor uses Non-interlaced / Progressive-scanned display. In order to encode image signals coming from devices that takes interlaced display format for progressive scanned display, a hardware logic in which scanning and interpolation algorithms are implemented is necessary. The ELA (Edge-Based Line Average) algorithm have been widely used because it provided good characteristics. In this study, the ADI(Adaptive De-interlacing Interpolation) algorithm using to improve the algorithm which shows low quality in vertical edge detections and low efficiency of horizontal edge lines. With the De-interlacing ASIC chip that converts the interlaced Digital YUV to De-interlaced Digital RGB is designed. The VHDL is used for chip design.

  • PDF

위상 보정된 웨이블릿 변환을 이용한 영상확대 (Image Interpolation Using Phase-Shifted Wavelet Transforms)

  • 김상수;엄일규;김유신
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2005년도 추계종합학술대회
    • /
    • pp.387-390
    • /
    • 2005
  • Parameter estimation for the probability model of wavelet coefficients is essential to the wavelet-domain interpolation. However, phase uncertainty, one well-known drawback of the orthogonal wavelet transforms, make it difficult to estimate parameters. In this paper, we exploit a phase shifting matrix in order to improve the accuracy of estimation. Nonlinear modeling to capture the interscale characteristics is also described. The experimental results show that the proposed method outperforms the previous wavelet-domain interpolation method as well as the conventional bicubic method.

  • PDF

Medical imaging을 위한 영상 보간 방법의 비교 (COMPARISON OF INTERPOLATION METHODS for MEDICAL IMAGING)

  • 이병길;하영호
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1990년도 추계학술대회
    • /
    • pp.38-41
    • /
    • 1990
  • A new spline function for resampling discrete signal adaptively is proposed. In general, B-spline function is used for an image interpolation because of its smoothness and continuity, but accompanies a large amount of blurring effect. Hence, we developed a new spline function to remedy this effect, with two procedures ; deblurring of Gaussian blurring and diminishing of aliasing effect caused by deblurring procedure. The proposed function has a parametric expression with $\alpha$ which is related to the variance of Gaussian blurring model. Locally adaptive resampling scheme is obtained by changing a according to statistical characteristics of an image. The proposed, interpolation function shows edge-sharpening effect as well as noise smoothing, with comparison to the conventional schemes.

  • PDF

AWGN 채널에서 보간기를 이용한 QAM 방식에 대한 심볼동기회로 설계 (Design of a Symbol Timing Recovery of QAM Using the Interpolation in AWGN channel)

  • 박범대;오동진;김철성
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 1999년도 하계종합학술대회 논문집
    • /
    • pp.77-80
    • /
    • 1999
  • This paper deals with a design of a symbol timing recovery circuit of QAM using the interpolation in AWGN channel. To reduce timing jitter and the amount of processing data, we employ MGA (Modified Gardner Algorithm) as a symbol timing error detector which is called NDA(Nondecision Directed Algorithm). We show the characteristics (S-curve and the variance) of timing error detector with the roll-off factor of a shaping filter, which are compared with GA. Also, we compare the BER curve of interpolation method with that of ideal case. The performance of the STR is shown to be close to that of ideal case. This result shows that this method can be useful to implement symbol timing recovery circuit for multi-level modulation.

  • PDF

GIS를 이용한 연안 수질등급 평가 (The Assessment of Coastal Water Quality Grade Using GIS)

  • 정종철;조홍래
    • 환경영향평가
    • /
    • 제15권1호
    • /
    • pp.45-52
    • /
    • 2006
  • The purpose of this study is to assess spatiotemporal variation of coastal water quality according to time and location changes. For this we developed numerical marine trophic index base on four water quality components (chlorophyll, suspended solids, dissolved inorganic nitrogen and phosphorus) and applied this index to the water quality data measured in the korean coastal zone for the 7-years period from 1997 to 2003. Water quality data are obtained only at selected sites even though they are potentially available at any location. Therefore, in order to estimate spatial variation of coastal water quality, it is necessary to estimate the unknown values at unsampled locations based on observation data. In this study, we used IDW (Inverse Distance Weighted) method to predict water quality components at unmeasured locations and applied marine trophic index to predicted values obtained by IDW interpolation. The results of this study indicate that marine trophic index and spatial interpolation are useful for understanding spatiotemporal characteristics of coastal water quality.

공간보간기법에 의한 서울시 미세먼지(PM10)의 분포 분석 (The Distribution Analysis of PM10 in Seoul Using Spatial Interpolation Methods)

  • 조홍래;정종철
    • 환경영향평가
    • /
    • 제18권1호
    • /
    • pp.31-39
    • /
    • 2009
  • A lot of data which are used in environment analysis of air pollution have characteristics that are distributed continuously in space. In this point, the collected data value such as precipitation, temperature, altitude, pollution density, PM10 have spatial aspect. When geostatistical data analysis are needed, acquisition of the value in every point is the best way, however, it is impossible because of the costs and time. Therefore, it is necessary to estimate the unknown values at unsampled locations based on observations. In this study, spatial interpolation method such as local trend surface model, IDW(inverse distance weighted), RBF(radial basis function), Kriging were applied to PM10 annual average concentration of Seoul in 2005 and the accuracy was evaluated. For evaluation of interpolation accuracy, range of estimated value, RMSE, average error were analyzed with observation data. The Kriging and RBF methods had the higher accuracy than others.

저해상도 CCD 소자 특성을 고려한 경계 모델 기반 디지털 정지 영상 확대 (Edge model based digital still image enlargement considering low-resolution CCD device characteristics)

  • 전준근;최영호;김한주;박규태
    • 한국통신학회논문지
    • /
    • 제23권9A호
    • /
    • pp.2345-2354
    • /
    • 1998
  • 디지털 카메라의 핵심 부품인 CCD(charge couple device) 소자의 해상도는 촬영된 영상의 화질에 결정적인 요인으로 작용하며 제품 제조 원가에서도 큰 비중을 차지한다. 낮은 해상도의 소자로부터 보다 높은 해상도의 화질을 얻기 위한 많은 연구가 진행되어왔다. 본 논문에서는 에일리어싱 성분을 가우시안 저역 필터로 제거한 후, 최소 자승 스플라인보간과 경계 모델에 기반한 비선형 보간을 사용함으로써 확대된 저해상도 영상의 계단 현상, 블록화 현상등을 줄이는 동시에, 선형 보간시 나타나는 경계주변의 울림현상(ringing effect) 번짐현상(blur effect)을 최소화한다.

  • PDF

소프트웨어 펄스 보간기의 성능비교 (Study on the Performance Comparision of Software Pulse Interpolators)

  • 안중환;임현석;이원규
    • 한국정밀공학회지
    • /
    • 제13권9호
    • /
    • pp.62-69
    • /
    • 1996
  • Interpolator is a very important element in NC machines in that it controls tool path and speed. In this paper, studied were extensive interpolation characteristics of reference pulse method among various interpolation and pulse generation methods. Specifically, processing speed and path error of DDA, SPD and SFG methods were compared and analyzed against line, circle and elipse. As a result, in the point of processing speed, SPD method was found to be the best for line interpolation, SFG method for circle and ellipse, and DDA method was found to be the slowest for all paths. In the point of path error, DDA method was found to have the biggest error for all kinds of paths.

  • PDF

휴대형 심전계 장치의 RR 간격의 정확도 개선을 위한 보간법 개발 (Interpolation Technique to Improve the Accuracy of RR-interval in Portable ECG Device)

  • 이은미;홍주현;차은종;이태수
    • 대한의용생체공학회:의공학회지
    • /
    • 제31권4호
    • /
    • pp.316-320
    • /
    • 2010
  • HRV(Heart rate variability) analysis parameter is widely used as an index to evaluate the autonomic nervous system and cardiac function. For reliable HRV analysis, we need to acquire the accurate ECG signals. Most of commercially available portable ECG devices have low sampling rate because of low power consumption and small size issues, which make it difficult to measure RR-interval accurately. This study is to improve the accuracy of RR-interval by developing R-wave interpolation technique, based on the morphological characteristics of the QRS complex. When the developed method was applied to ECG obtained at 200 Hz and the results were compared with 1000 Hz reference device, the error range decreased by 1.33 times in sitting and by 2.38 times in cycling exercise. Therefore, the proposed interpolation technique is thought to be useful to improve the accuracy of R-R interval in the portable ECG device with low sampling rate.