• Title/Summary/Keyword: International Healthcare

Search Result 490, Processing Time 0.027 seconds

Analyze dosimetry with and without shielding when amplifying scattered rays (산란선 증폭시 차폐체 유무에 따른 선량 분석)

  • Chang Ho Cho;Jeong Lae Kim
    • The Journal of the Convergence on Culture Technology
    • /
    • v.10 no.3
    • /
    • pp.819-825
    • /
    • 2024
  • The reason for recording dose data when using a diagnostic radiation source is to record and manage the dose to healthcare personnel and patients. The purpose of this study was to verify the difference in radiation dose when using diagnostic radiation generating devices and to inform users' awareness of dose reduction through measurement and analysis of dose in situations with and without shielding. The dose analysis of each equipment for two Korean C-arms and two German C-arms showed that the Korean FPD type C-arm had the highest dose value, followed by the German I.I type C-arm, German FPD type C-arm, Korean, and I.I type C-arm. The results of the dose analysis with and without shielding showed that the dose to the human phantom in a normal atmosphere increased by about 2 times due to scattered radiation, but the dose to the human phantom was reduced by about 5 times by wearing a shield (0.5mm/lead apron). More important than the management of radiation dose is the study of how to reduce exposure when using radiation, and since the radiation dose output from different equipment is different, it is necessary to provide dose information with and without shielding.

Can the Sasang Constitutional Type Trait Act as an Independent Risk Factor for Dyslipidemia? (사상체질이 이상지질혈증의 위험인자가 될 수 있는가?)

  • Lee, Jiwon;Jang, Hyunsu;Park, Byungjoo;Lee, Euiju;Koh, Byunghee;Lee, Junhee
    • Journal of Korean Medicine for Obesity Research
    • /
    • v.14 no.2
    • /
    • pp.63-71
    • /
    • 2014
  • Objectives: This study was designed to investigate the correlation between Sasang constitution and dyslipidemia and the possibility that Sasang constitution can be a risk factor of dyslipidemia. Methods: This study was a retrospective cross-sectional study based on chart review. Seventeen thousand sixty-nine charts which were collected from May 2007 to June 2010 in International Healthcare Service Center, Kyung Hee University Medical Center, were reviewed for the study. Fifteen thousand two hundred fifty charts including Sasang constitutional diagnosis and lipid profiling were selected and we examined the correlation between Sasang constitution and dyslipidemia. Results: After adjusted for body mass index, the levels of total cholesterol and triglyceride were highest in Taeeum group, and lowest in Soeum group. High-density lipoprotein was highest in Soeum group, and lowest in Taeeum group. After adjusted for age, sex, and body mass index, the odds ratios for 'high triglyceride' were 1.716 (1.411~2.087) in Soyang group and 2.021 (1.650~2.475) in Taeeum group compared to Soeum group. The odds ratio for 'high low-density lipoprotein' was 1.229 (1.006~1.501) in Soyang group compared to Soeum group. The odds ratios for 'low high-density lipoprotein' were 1.195 (1.033~1.381) in Soyang group and 1.414 (1.212~1.649) in Taeeum group compared to Soeum group. Conclusions: The lipid profiles and dyslipidemic risk differed across constitutional types, showing constitution type-specific patterns, so that we could infer the possibility that Sasang constitutional types can be a risk factor of dyslipidemia.

A Qualitative Study of Physicians' Perspectives on Non-Cancer Hospice-Palliative Care in Korea: Focus on AIDS, COPD and Liver Cirrhosis (국내의 비암성 질환의 호스피스 완화의료 적용에 대한 전문가의 인식에 관한 질적 연구: 후천성 면역결핍 증후군, 만성 폐쇄성 폐질환, 간경화를 중심으로)

  • Shin, Jinyoung;Yoon, Seok-Joon;Kim, Sun-Hyun;Lee, Eon Sook;Koh, Su-Jin;Park, Jeanno
    • Journal of Hospice and Palliative Care
    • /
    • v.20 no.3
    • /
    • pp.177-187
    • /
    • 2017
  • Purpose: From August 2017, hospice-palliative care (HPC) will be provided to patients with acquired immunodeficiency syndrome (AIDS), chronic obstructive pulmonary disease (COPD), and liver cirrhosis in Korea. To contribute to building a non-cancer (NC) hospice-palliative care model, NC specialists were interviewed regarding the goals, details, and provision methods of the model. Methods: Four physicians specializing in HPC of cancer patients formulated a semi-structured interview with questions extracted from literature review of 85 articles on NC HPC. Eleven NC disease specialists were interviewed, and their answers were analyzed according to the qualitative content analysis process. Results: The interviewees said as follows: It is difficult to define end-stage NC patients. HPC for cancer patients and that for NC patients share similar goals and content. However, emphasis should be placed on alleviating other physical symptoms and emotional care rather than pain control. Timing of the care provision should be when patients are diagnosed as "end stage". Special issues should be considered for each NC disease (e.g., use of anti-retroviral drugs for AIDS patients, oxygen supply for COPD patients suffering from dyspnea, liver transplantation for patients with liver cirrhosis) and education should be provided to healthcare professionals. NC patients tend to negatively perceive HPC, and the government's financial assistance is insufficient. Conclusion: It is necessary to define end-stage NC patients through in-depth discussion to minimize issues that will likely accompany the expansion of care recipients. This requires cooperation between medical staff caring for NC patients and HPC givers for cancer patients.

Detection and Measurement of Nuclear Medicine Workers' Internal Radioactive Contamination (핵의학과 종사자의 방사성동위원소 체내오염 측정)

  • Jeong, Gyu-Hwan;Kim, Yong-Jae;Jang, Jeong-Chan;Lee, Jai-Ki
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.3
    • /
    • pp.123-131
    • /
    • 2009
  • Purpose: We tested a sample of nuclear medicine workers at Korean healthcare institutions for internal contamination with radioactive isotopes, measuring concentrations and evaluating doses of individual exposure. Materials and Methods: The detection and measurement was performed on urine samples collected from 25 nuclear medicine workers at three large hospitals located in Seoul. Urine samples were collected once a week, 100~200 mL samples were gathered up to 6~10 times weekly. A high-purity germanium detector was used to measure gamma radiations in urine samples for the presence of radioactive isotopes. Based on the detection results, we estimated the amounts of intake and committed effective doses using IMBA software. In cases where committed effective doses could not be adequately evaluated with IMBA software, we estimated individual committed effective doses for radionuclides with a very short half life such as $^{99m}Tc$ and $^{123}I$, using the methods recommended by International Atomic Energy Agency. Results: Radionuclides detected through the analysis of urine samples included $^{99m}Tc$, $^{123}I$, $^{131}I$ and $^{201}Tl$, as well as $^{18}F$, a nuclide used in Positron Emission Tomography examinations. The committed effective doses, calculated based on the radionuclide concentrations in urine samples, ranged from 0 to 5 mSv, but were, in the majority of cases, less than 1 mSv. The committed effective dose exceeded 1 mSv in three of the samples, and all three were workers directly handling radioactive sources. No nurses were found to have a committed effective dose in excess of 1 mSv. Conclusions: To improve the accuracy of results, it may be necessary to conduct a long-term study, performed over a time span wide enough to allow the clear determination of the influence of seasonal factors. A larger sample should also help increase the reliability of results. However, as most Korean nuclear medicine workers are currently not necessary to monitored routinely for internal contamination with radionuclides. Notwithstanding, a continuous effort is recommended to reduce any unnecessary exposure to radioactive substances, even if in inconsequential amounts, by regularly surveying workplace environments and frequently monitoring atmospheric concentrations of radionuclides.

  • PDF

Imaging Characteristics of Computed Radiography Systems (CR 시스템의 종류와 I.P 크기에 따른 정량적 영상특성평가)

  • Jung, Ji-Young;Park, Hye-Suk;Cho, Hyo-Min;Lee, Chang-Lae;Nam, So-Ra;Lee, Young-Jin;Kim, Hee-Joung
    • Progress in Medical Physics
    • /
    • v.19 no.1
    • /
    • pp.63-72
    • /
    • 2008
  • With recent advancement of the medical imaging systems and picture archiving and communication system (PACS), installation of digital radiography has been accelerated over past few years. Moreover, Computed Radiography (CR) which was well established for the foundation of digital x-ray imaging systems at low cost was widely used for clinical applications. This study analyzes imaging characteristics for two systems with different pixel sizes through the Modulation Transfer Function (MTF), Noise Power Spectrum (NPS) and Detective Quantum Efficiency (DQE). In addition, influence of radiation dose to the imaging characteristics was also measured by quantitative assessment. A standard beam quality RQA5 based on an international electro-technical commission (IEC) standard was used to perform the x-ray imaging studies. For the results, the spatial resolution based on MTF at 10% for Agfa CR system with I.P size of $8{\times}10$ inches and $14{\times}17$ inches was measured as 3.9 cycles/mm and 2.8 cycles/mm, respectively. The spatial resolution based on MTF at 10% for Fuji CR system with I.P size of $8{\times}10$ inches and $14{\times}17$ inches was measured as 3.4 cycles/mm and 3.2 cycles/mm, respectively. There was difference in the spatial resolution for $14{\times}17$ inches, although radiation dose does not effect to the MTF. The NPS of the Agfa CR system shows similar results for different pixel size between $100{\mu}m$ for $8{\times}10$ inch I.P and $150{\mu}m$ for $14{\times}17$ inch I.P. For both systems, the results show better NPS for increased radiation dose due to increasing number of photons. DQE of the Agfa CR system for $8{\times}10$ inch I.P and $14{\times}17$ inch I.P resulted in 11% and 8.8% at 1.5 cycles/mm, respectively. Both systems show that the higher level of radiation dose would lead to the worse DQE efficiency. Measuring DQE for multiple factors of imaging characteristics plays very important role in determining efficiency of equipment and reducing radiation dose for the patients. In conclusion, the results of this study could be used as a baseline to optimize imaging systems and their imaging characteristics by measuring MTF, NPS, and DQE for different level of radiation dose.

  • PDF

The Evaluation and Development of Head and Neck Radiation Protective Device for Chest Radiography in 10 Years Children (소아(10세) 흉부 방사선촬영에서의 두경부 방사선 방어기구 개발 및 평가)

  • Lee, Jun Ho;Lim, Hyun Soo;Lee, Seung Yeol
    • Journal of Radiation Protection and Research
    • /
    • v.40 no.2
    • /
    • pp.118-123
    • /
    • 2015
  • The frequency of diagnostic radiation examinations in medical institutions has recently increased to 220 million cases in 2011, and the annual exposure dose per capita was 1.4 mSv, 51% and 35% respectively, compared to those in 2007. The number of chest radiography was found to be 27.59% of them, the highest frequency of normal radiography. In this study, we developed a shielding device to minimize radiation exposure by shielding areas of the body which are unnecessary for image interpretation, during the chest radiography. And in order to verify its usefulness, we also measured the difference in entrance surface dose (ESD) and the absorbed dose, before and after using the device, by using an international standard pediatric (10 years) phantom and a glass dosimeter. In addition, we calculated the effective dose by using a Monte Carlo simulation-based program (PCXMC 2.0.1) and evaluated the reduction ratio indirectly by comparing lifetime attributable risk of cancer incidence (LAR). When using the protective device, the ESD decreased by 86.36% on average, nasal cavity $0.55{\mu}Sv$ (74.06%), thyroid $1.43{\mu}Sv$ (95.15%), oesophagus $6.35{\mu}Sv$ (78.42%) respectively, and the depth dose decreased by 72.30% on average, the cervical spine(upper spine) $1.23{\mu}Sv$ (89.73%), salivary gland $0.5{\mu}Sv$ (92.31%), oesophagus $3.85{\mu}Sv$ (59.39%), thyroid $2.02{\mu}Sv$ (73.53%), thoracic vertebrae(middle spine) $5.68{\mu}Sv$ (54.01%) respectively, so that we could verify the usefulness of the shielding mechanism. In addition, the effective dose decreased by 11.76% from $8.33{\mu}Sv$ to $7.35{\mu}Sv$ before and after wearing the device, and in LAR assessment, we found that thyroid cancer decreased to male 0.14 people (95.12%) and female 0.77 people (95.16%) per one million 10-year old children, and general cancers decreased to male 0.14 people (11.70%) and female 0.25 people (11.70%). Although diagnostic radiation examinations are necessary for healthcare such as the treatment of diseases, based on the ALARA concept, we should strive to optimize medical radiation by using this shielding device actively in the areas of the body unnecessary for the diagnosis.

Demand for the Radiological Technologist Independent Act for the Performance of the Duties of a Radiological Technologist (방사선사 직무수행을 위한 방사선사 단독법 제정에 대한 요구도)

  • Kim, Eun-Hye;Lim, Cheong-Hwan;Lim, Woo-Taek;Joo, Young-Cheol;Hong, Dong-Hee;Jung, Hong-Ryang;Moon, Young-Ju;Kim, Hoon;Jung, Young-Jin;Choi, Ji-Won;Yoon, Yong-Su;Cho, Pyong-Kon;Park, Myeong-Hwan;Yang, Oh-Nam;Jeong, Bong-Jae
    • Journal of radiological science and technology
    • /
    • v.44 no.5
    • /
    • pp.525-534
    • /
    • 2021
  • In order to provide high-quality medical services to the public and contribute to the improvement of public health, it is necessary to enact an independent law according to the work of radiological technologists. Therefore, this study intends to review the regulations related to radiographers in the Medical Service Technologists, etc. Act. and to present opinions and directions for enactment of individual laws for radiological technologists. An online survey was conducted to 15,000 radiological technologists working in medical institutions and education sites in Korea; 1,027 people (6.85%) responded. The questionnaire consisted of 3 questions on demographic characteristics, 5 questions on the scope of work, and 12 questions on the revision of the Medical Service Technologists, etc. Act. and the establishment of the Radiological Technologist Independent Act. Reliability and factor analysis were performed on 9 questions measured on a Likert 5-point scale in "Revision of the Medical Service Technologists, etc. Act. and the establishment of the Radiological echnologist Independent Act" among the questionnaire items. Reliability for the total 9 questions was Chronbach α=0.728. There was a high perception that the regulations related to radiological technologists were insufficient in the current Medical Service Technologists, etc. Act., and the perception that examinations performed by radiological technologists at medical institutions were included in medical practice was high. If the Radiological Technologist Independent Act is enforced, a high percentage of respondents said that they could receive legal protection through the institutionalization of the scope of work, that the status of radiological technologists would be improved, and the scope of work would be expanded. The response that the scope of work of radiological technologists should be included was the highest at 96.6%. In the analysis according to demographic characteristics, it was found that 96.7% of the respondents were agreed regardless of the factors. Radiological technologists will have to work hard to secure the public health by coping with new radiology devices, procedures and treatment methods. Therefore, as the results of this study, it is expected that the enactment and implementation of the Radiological Technologist Independent Act will contribute to the improvement of the quality of treatment for patients and to the public health.

Isolation and characterization of cellulolytic yeast belonging to Moesziomyces sp. from the gut of Grasshopper (메뚜기의 내장에서 분리한 Moesziomyces 속에 속하는 셀룰로오스 분해 효모의 분리 및 특성)

  • Kim, Ju-Young;Jung, Hee-Young;Park, Jong-Seok;Cho, Sung-Jin;Lee, Hoon Bok;Sung, Gi-Ho;Subramani, Gayathri;Kim, Myung Kyum
    • Korean Journal of Microbiology
    • /
    • v.55 no.3
    • /
    • pp.234-241
    • /
    • 2019
  • An intensive interaction between yeasts and insects has highlighted their relevance for attraction to food and for the insect's development and behavior. Yeast associated in the gut of insects secretes cellulase which aided in the food digestion (cellulose degradation). Three strains of cellulose-degrading yeast were isolated from the gut of adult grasshoppers collected in Gyeonggi Province, South Korea. The strains $ON22^T$, $G10^T$, and $G15^T$, showed positive cellulolytic activity in the carboxymethyl cellulose (CMC)-plate assay. The phylogenetic tree based on sequence analysis of D1/D2 domains of the large subunit rRNA gene and the internal transcribed spacer (ITS) regions revealed that the strains $ON22^T$ (100 and 98.4% sequence similarities in D1/D2 domains and ITS) and $G10^T$ (99.8 and 99.5% in D1/D2 domain and ITS region) were most closely related to the species Moesziomyces aphidis JCM $10318^T$; $G15^T$ (100% in D1/D2 domains and ITS) belongs to the species Moesziomyces antarcticus JCM $10317^T$, respectively. Morphology and biochemical test results are provided in the species description. Cellulase with its massive applicability has been used in various industrial processes such as biofuels like bioethanol productions. Therefore, this is the first report of the cellulolytic yeast strains $ON22^T$, $G10^T$, and $G15^T$ related to the genus Moesziomyces in the family Ustilaginaceae (Ustilaginales), in Korea.

Physiological Activity of Robinia pseudo acacia Leaf Extracts and Enhancement of Skin Permeation Using Polymer Micelles and Cell Penetrating Peptide (아카시아 잎 추출물의 생리 활성 및 고분자 미셀과 세포투과 펩티드를 적용한 피부흡수증진 효과)

  • Heo, Soo Hyeon;Park, Su In;An, Gyu Min;Shin, Moon Sam
    • The Journal of the Convergence on Culture Technology
    • /
    • v.5 no.3
    • /
    • pp.271-282
    • /
    • 2019
  • This study was conducted to evaluate physiological activity of Robinia pseudo-acacia leaf and its skin penetration using polymer micelles and skin penetrating peptide. After extraction with Robinia pseudo-acacia using the ethanol and distilled water, various physiological activities were examined. The total concentration of polyphenol compounds was determined to be 47.42 mg/g (ethanol extract), 56.88 mg/g (hydrothermal extract) and DPPH radical scavenging ability at $1,000{\mu}g/mL$ was 44.24% in ethanol extract and it is higher than value(41.50%) in hydrothermal extract. The elastase inhibitory assay showed concentration dependence and elastase inhibition of Robinia pseudo acacia leaf ethanol extract was 54.09%, which was the highest at $500{\mu}g/mL$. In the SOD-like experiments, the concentration-dependent results were showed and the SOD-like activity of the Robinia pseudo-acacia leaf ethanol extract was higher than that of the Robinia pseudo acacia leaf hydrothermal extract at all concentrations. At a concentration of $500{\mu}g/mL$, Robinia pseudo acacia leaf ethanol extract showed the highest SOD-like activity of 76.41%. The tyrosinase inhibition at $20{\mu}g/mL$ was determined to be 56.47% (ethanol extract), 23.05% (hydrothermal extract). In the antimicrobial experiments, the hydrothermal extract had no effect, but ethanol extract represented maximum clear zone of 11.00 mm in Propionbacterium acnes strain and maximum clear zone of 10.50 mm. in Bacillus subtilis strain. To solve the problem of insolubility and to improve skin penetration, PCL-PEG polymer micelles containing Robinia pseudo-acacia leaf ethanol extracts and 1.0% cell permeable peptide, hexa-D-arginine (R6) were successfully prepared with particle size of 108.23 and 126.47 nm and excellent skin permeation effects could be showed.

Analysis of Factors Affecting the Length of Stay in Children(Aged 0 to 12) with Injuries: Centering Around the Data from the Korea National Hospital Discharge In-Depth Injury Surveys (어린이(0-12세) 손상환자의 재원일수에 미치는 요인분석: 퇴원손상심층자료를 중심으로)

  • Lee Chae Kyung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.9 no.3
    • /
    • pp.137-143
    • /
    • 2023
  • This study was conducted to analyze factors affecting the length of stay in children with injuries by determining relationships between length of stay and characteristics of children(aged 0 to 12) with injuries. 7,804 patients aged 0 to 12 who participated in the Korea Nation Hospital Discharge In-Depth Injury Surveys, got a diagnosis of sequelae of injuries and of other consequences of external causes(S00-T98), and were discharged between 1 January 2016 and 31 December 2020 were investigated. A frequency analysis, independent samples t-test, and ANOVA were performed. Also, to identify factors affecting the length of stay, a regression analysis was performed. The average length of stay for the patients investigated in this study was 5.5 days. The length of stay for school-age children(aged 7 to 12) and children who had either public or private coverage was higher than that for preschoolers(aged 0 to 6) and children who didn't have public or private coverage, respectively. The length of stay for children admitted to a hospital in a rural area(Jeolla-do or Gyeongsang-do) was higher than that for children admitted to a hospital in a metropolitan area and the length of stay for children admitted to a hospital that had 100-299 hospital beds was relatively long. However, children who first visited a hospital for outpatient care stayed relatively short in hospital and children who had been burned or injured in traffic crashes stayed relatively long in hospital. Children who got a secondary diagnosis and had a principal procedure or who died after being discharged were in hospital for a long time. The findings of this study shall be useful, as they identified characteristics related to the length of stay for Korean children with injuries and factors that determine the length of stay for those children by analyzing the national dataset, or more specifically, the data from the Korea National Hospital Discharge In-Depth Injury Surveys. The risk of child injuries can be easily reduced by taking actions to prevent them and providing safety education programs. The present study has provided essential baseline data for the provision of aggressive care for child injuries and the establishment of a range of policies for child injury prevention.