• 제목/요약/키워드: Internal insulation

검색결과 231건 처리시간 0.021초

건물 부하계산 프로그램을 이용한 외단열 시공의 에너지 절감 효과 분석 (Analysis of the Energy Saving Effect for the External Insulation Construction by Building Load Calculation Method)

  • 박재중;명제민;송두삼
    • 설비공학논문집
    • /
    • 제29권3호
    • /
    • pp.97-104
    • /
    • 2017
  • Reinforcement of insulation in apartment buildings reduces the heating and cooling energy consumption by lowering the heat transfer in the building envelope. There are differences between internal and external insulation methods in heat transmission properties. However, some building load calculation programs cannot analysis the differences between the two. This is because these programs do no account for the timelag or thermal storage effect of the wall according to the location of insulation. In this study, the heat transmission characteristics of internal and external insulation were analyzed by EnergyPlus, and heating and cooling energy demand was compared. The results showed that external insulation system had lower heating and cooling loads than internal insulation system. Also the heat transfer rate of external insulation is steadier than internal insulation. About 13.6% of heating and cooling energy demand decreased when the outdoor wall was finished with external insulation compared to the demand with internal insulation.

단열재 개선을 통한 PKG-A Water Jet Room 온도저감 연구 (A Study on the Internal Temperature Reduction of PKG-A Water-jet-room by Substituting Heat Insulation Materials)

  • 정영인;최상민
    • 품질경영학회지
    • /
    • 제47권3호
    • /
    • pp.425-435
    • /
    • 2019
  • Purpose: The purpose of this study was to resolve the Naval ship's Local Operation Panel(LOP) malfunction problems which caused by overheating in summer season and dispatching to equatorial regions. Methods: Instead of using dual type heat insulation materials(consist with ceramic wool and glass wool), aerogel heat insulation materials were used for decreasing heat emissions from gas-turbine heat waste steam pipes passing water-jet- room. Experiment and Computational analysis of heat flow were conducted to analyze the internal room temperature changes. Results: The results of this study are as follows; The aerogel heat insulation materials suppress heat emission more efficiently than dual type insulation materials. The cold surface temperature of insulation was far more decreased and internal room, LOP surface temperature also showed significant results too. Conclusion: The substituted heat insulation materials appeared remarkable performance in decreasing room temperature that it could be used for suppressing the LOP overheatings and malfunctions.

공동주택의 단열형태별 선형열관류율 평가 (An Evaluation of the Linear Thermal Transmittance for the Internal Insulation versus the External Insulation in Apartment Housings)

  • 이종성;이도헌;전명훈
    • 토지주택연구
    • /
    • 제5권4호
    • /
    • pp.315-323
    • /
    • 2014
  • 본 연구는 외단열시스템 성능평가의 주요인자인 선형열관류율을 국제규격(ISO)에서 제시하고 있는 평가방법에 의거, 내단열시스템 대비 외단열시스템의 열성능에 대한 우수성을 정량적으로 파악하고, 향후 외단열시스템의 열성능 평가를 위한 기초자료로의 활용을 목적으로 한다. 이를 위해 공동주택의 대표적 열교부위인 3개 부위를 내단열과 외단열 시스템으로 설계하고, 각 부위별 단열형태별로 선형열관류율을 평가하였다. 그 결과, 외벽-발코니 슬라브 부위는 열교차단재 설치가 필수적인 것으로 분석되었으며, 열교차단재를 설치할 경우 외단열시스템이 내단열시스템보다 선형열관류율이 1/2 이상 줄어드는 것으로 나타났다. 측벽-발코니 부위와 같이 슬라브가 외부로 돌출되지 않는 구조에서는 외단열시스템을 적용할 경우, 선형열관류율이 거의 0인 것으로 나타났다. 내단열로 설계된 외벽-경계벽의 경우, 선형열관류율은 0.451W/m 로 내단열로 설계된 외벽-발코니 슬라브 등 열교가 있는 부위와 비슷한 값을 보이며, 외단열로 설치될 경우 이 또한 거의 0인 것으로 나타났다. 향후, 공동주택의 외단열시스템 도입 및 성능평가를 위해서는 국제기준을 적용한 국내 평가기준의 제도화마련이 필요하며, 특히 제도화 마련과정에서 선형열관류율 계산 인자 중의 하나인 벽체길이의 계산방법은 국가차원의 결정이 필요할 것으로 판단된다.

노후화된 대학 건물의 단열성능 향상 실험 및 경제성 평가 (An Experimental Study on the Improvement of Insulation Performance in Old University Buildings and Economic Evaluation)

  • 이정민;소원호;조경찬;최동녁;이권영
    • 한국산학기술학회논문지
    • /
    • 제21권8호
    • /
    • pp.287-297
    • /
    • 2020
  • 본 연구는 노후화된 대학 건물의 내부 단열 성능 향상에 대한 것으로, 대학교 건물 내 재실자의 생산성을 높이고 노후화된 건물의 단열효과를 높이기 위해 진행됐다. 본 논문은 한동대학교 느헤미야홀 건물 내 오피스 재실자의 단열 성능 향상에 대한 지속적인 요청에 응답하여 문제해결을 위해 진행된 연구라는 차별성을 가지고 있으며, 내부온도가 인접건물의 내부온도와 비교했을 때 낮음을 확인하여 연구 필요성에 대한 타당성을 검증하였다. 학교라는 건물의 특성을 고려해 내외부 단열 중 내부 단열을 주제로 단열재를 선택했다. 대학교 교수 오피스를 소형화시킨 모형 방을 만들어 시장에서 사용되는 내부 벽면 단열재를 설치해 실험을 진행했다. 실험 결과를 바탕으로 가열 시간과 실제 열전달 계수를 측정하여 단열효과를 분석하는 경제성 평가를 실시했다. 경제성 평가는 실험과 이론에 의해, 겨울철과 여름철 기준으로 각각 실시되었다. 연구결과, 느헤미야홀 60 개의 오피스에 아이소핑크(30 T)를 내 단열재로 도입하였을 때, 한 달에 겨울철에는 최대 총 1,071,600 원을 절약 할 수 있으며, 여름철에는 총 109,200 원을 절약할 수 있다.

LED 가로등 및 보안등기구의 절연특성 연구 (A Study on the Insulation Characteristics of LED Lamps for Load and Street Lighting)

  • 김향곤;길형준;김동욱;김동우
    • 전기학회논문지P
    • /
    • 제58권4호
    • /
    • pp.546-551
    • /
    • 2009
  • In this paper, we studied insulation characteristics of LED lamps for load and street lighting. LED lamps can be divided into internal type and external type according to converter type. In this study, we analyzed technology standard, K(Electrical Appliances Safety Standards) and KS(Korean Industrial Standards) about insulation resistance for LED lamps for load and street lighting, and measured insulation resistances for each measured point. Mostly, insulation resistances were measured high more than regulation value but some measured points were measured badly. We expect that the results of these experiments would be helpful for electrical safety of LED lighting installation, manufacture, construction and maintenance.

한국형 패시브하우스를 위한 단열블럭시스템의 난방에너지소비 특성 (A Characteristic Heating-Energy Expend of Insulation Block System for Korea Type Passive House)

  • 강재식;최경석;양관섭;이승언
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.603-607
    • /
    • 2009
  • About a Structure is performance external insulation is fundamantal performance for enrgy-saving. these day, most of residential structures have constructed by internal insulation method structure. The method structure internal insulation have construction and economical efficiency, but on the other hand, be generated heat loss by heat bridge especially, be generated loss heat-energy logical consequence in structure ondol. The external insulation structure method has a mert able to minimum to loss heat about heat-bridge. But the external insulation technique is unsatisfactory statues within the know-how and method of construction and materials compared with developed countries. The recently, the requirement of market related to the external insulation technique is resulted by the energy efficiency system, but it can lead to the lack of alternative technique In study on the korea type passive house building design for insulation block method of wall system has to experimental characteristic heat-energy of practice building. In result field-experimental, the heat-bridge appeared to characteristic spent heat-energy of blow 2L class and have a suffience performance it.

  • PDF

Evaluation of sloshing resistance performance for LNG carrier insulation system based on fluid-structure interaction analysis

  • Lee, Chi-Seung;Cho, Jin-Rae;Kim, Wha-Soo;Noh, Byeong-Jae;Kim, Myung-Hyun;Lee, Jae-Myung
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제5권1호
    • /
    • pp.1-20
    • /
    • 2013
  • In the present paper, the sloshing resistance performance of a huge-size LNG carrier's insulation system is evaluated by the fluid-structure interaction (FSI) analysis. To do this, the global-local analysis which is based on the arbitrary Lagrangian-Eulerian (ALE) method is adopted to accurately calculate the structural behavior induced by internal LNG sloshing of a KC-1 type LNG carrier insulation system. During the global analysis, the sloshing flow and hydrodynamic pressure of internal LNG are analyzed by postulating the flexible insulation system as a rigid body. In addition, during the local analysis, the local hydroelastic response of the LNG carrier insulation system is computed by solving the local hydroelastic model where the entire and flexible insulation system is adopted and the numerical analysis results of the global analysis such as initial and boundary conditions are implemented into the local finite element model. The proposed novel analysis techniques can potentially be used to evaluate the structural integrity of LNG carrier insulation systems.

컨버터 내장형 LED 가로등 및 보안등의 전기적 특성 분석 (Electrical Characteristics Analysis of LED Lamps using Internal Converter for Road and Street Lighting)

  • 김향곤;길형준;최효상
    • 전기학회논문지P
    • /
    • 제59권2호
    • /
    • pp.238-244
    • /
    • 2010
  • In this paper, we studied electrical characteristics of internal converter type of LED lamps for road and street lighting. We surveyed electro-technical regulations and KS(Korean industrial standards) about LED luminairs. Waveforms of voltage and current, thermal distributions, insulation resistances between live parts and exposed conductive parts, and flame test of cover of LED lamps were experimented and analyzed. In regulations, insulation resistance between live conductors and exposed conductive parts should be greater than $0.2M{\Omega}$ in case nominal voltage of wiring is 220V. In KS codes, the value of insulation resistance should be greater than $2M{\Omega}$ while applying DC 500V or DC 100V. In the result of this study, waveforms of primary voltage and current were distorted. There was difference in waveforms of secondary voltage and current according to composition of converter. Mostly, insulation resistances were measured high more than regulation and code value but some measured points were measured badly($0.0M{\Omega}$). Cover of LED lamps was ignited easily. We expect that the results of this study would be helpful for revision of regulations and national codes for the electrical safety of LED road and street lighting.

내, 외단열 공동주택의 축열체 위치 차이에 따른 동단위 연간 냉난방부하 비교평가 (Comparison of Annual Heating and Cooling Loads of Internally and Externally Insulated Apartment Buildings According to the Location of Thermal Mass)

  • 구보경;이병인;최두성;송승영
    • 한국태양에너지학회 논문집
    • /
    • 제30권1호
    • /
    • pp.42-49
    • /
    • 2010
  • The IIS(Internal Insulation System) is applied in most Korean apartment buildings which are the most common type of residential buildings. Consequently, there are many cases in which the layer of insulation is disconnected by the structural components at the wall-slab and wall-wall joints in the envelope. These joints become thermal bridges where the risk of heat loss increases. It is expected that the EIFS(External Insulation and Finish System) is the solution to this problem. In this study, annual heating and cooling loads of apartment buildings with IIS and EIFS were compared using Design Builder program in order to evaluate the thermal storage effect of EIFS where the concrete thermal mass is located inside of the insulation material. As results, the apartment building with EIFS could reduce annual heating and cooling loads by 2.4% and 4.1%, respectively.

수치해석을 이용한 다겹보온자재의 내부공기층 함유에 따른 보온 특성 (Thermal Insulation Property due to Internal Air-layer Content of Warm Multi Layer Materials by using Numerical Analysis)

  • 정성원
    • 한국기계가공학회지
    • /
    • 제11권4호
    • /
    • pp.97-103
    • /
    • 2012
  • This study investigates thermal insulation properties of multi layer materials depending on thickness of air layers. Numerical analysis on the heat flow of different insulating materials was conducted to identify whether their temperature distributions demonstrate the reduced rate of heat transfer conclusively or not. Analytical model is divided into two categories. One is to distinguish temperature distribution of the air-layer materials from the non-air layer ones. The other is to compare the efficacy between eight-layered insulating materials with no air-layer contained and three-layered insulating materials which include an air-layer definitely. In the latter case, the identical thickness is assigned to each material. The effect of thermal insulation by including an air-layer is verified in the first analytical model. The result of the second model shows that the insulation of the eight-layered materials is coterminous at the three-layered ones with an air-layer and the thermal insulation of the two materials is imperceptible. The benefits of cost and energy saving are anticipated if air-layers are efficiently incorporated in multi layer insulating materials in a greenhouse.