• 제목/요약/키워드: Internal gap

검색결과 406건 처리시간 0.033초

Clinical gap changes after porcelain firing cycles of zirconia fixed dentures

  • Bugurman, Bugurman Burcu;Turker, Sebnem Begum
    • The Journal of Advanced Prosthodontics
    • /
    • 제6권3호
    • /
    • pp.177-184
    • /
    • 2014
  • PURPOSE. The aim of this study was to measure the changes on the marginal and internal adaptation of zirconia based anterior fixed partial dentures after the porcelain firing process. MATERIALS AND METHODS. A total of 34 anterior fixed partial dentures using LAVA CAD/CAM system (3M ESPE, Germany) were applied. Two silicone replicas were obtained: one is obtained before porcelain firing process (initial) and the other is obtained after porcelain firing process (final), followed by the examination under a binocular stereomicroscope. Kruskal Wallis and Wilcoxon Signed Ranks tests were used for the statistical analysis (P<.05). RESULTS. No statistically significant difference was found between initial and final marginal gap values (P>.05). At the internal gap measurements, final marginal area values ($59.54{\mu}m$) were significantly lower than the initial marginal area values ($68.68{\mu}m$)(P<.05). The highest and the lowest internal gap values were observed at the incisal/occlusal area and at the marginal area, respectively. In addition, lower internal gap values were obtained for canines than for central incisors, lateral incisors and premolars at the incisal area (P<.05). CONCLUSION. The firing cycles did not affect the marginal gap of Lava CAD/CAM system, but it is controversial for the internal gap.

Marginal and internal fit of nano-composite CAD/CAM restorations

  • Park, So-Hyun;Yoo, Yeon-Jee;Shin, Yoo-Jin;Cho, Byeong-Hoon;Baek, Seung-Ho
    • Restorative Dentistry and Endodontics
    • /
    • 제41권1호
    • /
    • pp.37-43
    • /
    • 2016
  • Objectives: The purpose of this study was to compare the marginal and internal fit of nano-composite CAD-CAM restorations. Materials and Methods: A full veneer crown and an mesio-occluso-distal (MOD) inlay cavity, which were prepared on extracted human molars, were used as templates of epoxy resin replicas. The prepared teeth were scanned and CAD-CAM restorations were milled using Lava Ultimate (LU) and experimental nano-composite CAD/CAM blocks (EB) under the same milling parameters. To assess the marginal and internal fit, the restorations were cemented to replicas and were embedded in an acrylic mold for sectioning at 0.5 mm intervals. The measured gap data were pooled according to the block types and measuring points for statistical analysis. Results: Both the block type and measuring point significantly affected gap values, and their interaction was significant (p = 0.000). In crowns and inlays made from the two blocks, gap values were significantly larger in the occlusal area than in the axial area, while gap values in the marginal area were smallest (p < 0.001). Among the blocks, the restorations milled from EB had a significantly larger gap at all measuring points than those milled from LU (p = 0.000). Conclusions: The marginal and internal gaps of the two nano-composite CAD/CAM blocks differed according to the measuring points. Among the internal area of the two nano-composite CAD/CAM restorations, occlusal gap data were significantly larger than axial gap data. The EB crowns and inlays had significantly larger gaps than LU restorations.

구강 내 스캐너를 사용하여 CAD/CAM으로 제작된 왁스 코핑의 적합도 평가 (Evaluation of marginal and internal gap of wax coping fabricated by CAD/CAM system using intraoral scanner)

  • 김동연;정일도;이재준;김지환;김명배;김웅철
    • 대한치과기공학회지
    • /
    • 제37권1호
    • /
    • pp.1-7
    • /
    • 2015
  • Purpose: The aim of this study was to evaluate the marginal and internal gap of wax copings fabricated from extraoral scanning with intraoral scanning. Methods: Fifteen study models(abutment of teeth 16) were made by PMMA. STL files of thirty abutment were prepared by intraoral scanning with extraoral scanning. Wax copings of thirty fabricated using CAD/CAM system. Marginal and internal gap of wax copings of thirty were measured by silicone replica technique and digital microscope(${\times}140$). Date were analyzed by using independent samples t-test. Results: Mean (SD) of two group were measured $55.61(27.42){\mu}m$ for totally gap of ES group and $60.67(33.14){\mu}m$ for totally gap of IS group. But marginal and internal gap of two group were not differences statistically significant(p>0.05). Conclusion: Evaluation of marginal and internal gap of two group showed that no differences statistically significant and clinically acceptable results.

내부전극 조밀도 변화에 따른 중첩방전형 오존발생기의 특성 (The Characteristics of a Superposed Discharge Type Ozonizer with Variation of Mesh in Internal Electrode)

  • 송현직
    • 조명전기설비학회논문지
    • /
    • 제19권5호
    • /
    • pp.87-93
    • /
    • 2005
  • 본 논문에서는 고농도$\cdot$고수율 오존발생기를 개발할 목적으로 망사형 내부전극과 무성방전의 중첩을 이용한 중첩방전형 오존발생기를 설계$\cdot$제작하였다. 중첩방전형 오존발생기는 방전공간에 3개의 전극(중심전극, 내부전극 및 외부전극)과 2개의 gap(중심전극과 내부전극 사이의 gap과 내부전극과 외부전극 사이의 gap)으로 구성되어있다. 중첩방전형 오존발생기의 중심전극을 공통접지하고 내부전극과 외부전극에 $180{[^\circ]}$의 위상차를 가진 역극성의 교류 고전압을 각각 인가하면 각각의 방전 gap에서 발생하는 무성방전이 중첩되면서 오존이 발생된다. 이때, 내부전극의 조밀도가 증가할수록 방전전극의 면적이 확대되고 방전공간의 전력밀도가 억제되어 오존생성특성이 상승하였다. 그 결과 최대 17,720[ppm], 5.4[g/h] 및 250[g/kwh]의 오존을 얻을 수 있었다.

시멘트 공간이 캐드캠 시스템으로 제작한 지르코니아 수복물의 변연과 내부 적합도에 미치는 효과 (Effect of cement space on the marginal and internal fit of zirconia restorations fabricated by CAD/CAM system)

  • 이정환;안재석
    • 대한치과기공학회지
    • /
    • 제39권4호
    • /
    • pp.235-242
    • /
    • 2017
  • Purpose: The aim of this study was to evaluate the marginal and internal gap of zirconia copings fabricated by CAD/CAM system and to research the effect of cement space on the fit of zirconia prosthesis. Methods: Zirconia copings were designed using 3shape software and then milled from presintered zirconia blocks by Kavo dental milling machine. The cement space was set at $0{\mu}m$ around the margins for all groups, and additional cement space appling 1 mm above the finish lines of tooth. The samples were classified into 4 groups according to the cement space setting(Cs-0, Cs-40, Cs-80, Cs-120). Replica technique used to investigate marginal and internal gap. The silicone film thickness was recorded using a optical microscope with image software analysis system at 75${\times}$magnification. The assessment performed on the six points in bucco-lingual and mesio-distal sections(4 groups, 10 copings per group, 12 measuring points per coping). The data were statistically analyzed with one-way ANOVA followed by pair-wise Tukey's post hoc tests(${\alpha}$<0.05). Results: Better marginal and internal fit values were exhibited by $80{\mu}m$ cement space. The results showed that different cement space values had statistically significant effect on the marginal and internal gap of zirconia copings(p<0.001). The gap of margin and axial wall area was smaller than that the gap of occlusal area in all groups(p<0.001). Conclusion : Effect of different cement spaces on the marginal and internal gap of zirconia copings.

내부 공동과 간극이 종 음향에 미치는 영향에 대한 실험적 연구 (An Experimental Study on the Influence of the Internal Cavity and Gap on the Bell Acoustics)

  • 정원태;강연준;김석현
    • 한국소음진동공학회논문집
    • /
    • 제20권9호
    • /
    • pp.822-827
    • /
    • 2010
  • In this study, it is experimentally investigated how bell acoustics are influenced by the internal cavity of the bell and the gap between the bell bottom and the floor. Acoustic transmission function and natural frequency of a test bell are measured and analysed. Experimental study is conducted to evaluated how the resonance effect influences the bell sound and how the bell sound is different according to the striking condition and the measurement direction. Acoustic resonance frequency of the cavity-gap system is predicted by boundary element analysis using SYSNOIS and the validity of the predicted result is verified by experiment. The result of the study could be applied to determine the optimal gap size which makes the bell sound strong and long.

Sengmaek-san-mediated Enhancement of Axonal Regeneration after Sciatic Nerve Injury in the Rat

  • Baek, Kyung-Min;Kim, Yoon-Sik;Ryu, Ho-Ryong;Jo, Hyun-Kyung;An, Jung-Jo;Namgung, Uk;Seol, In-Chan
    • 동의생리병리학회지
    • /
    • 제22권2호
    • /
    • pp.431-437
    • /
    • 2008
  • Sengmaek-san(Shengmai-san; SMS) is used in oriental medicine as one of the key herbal medicine for treating diverse symptoms including cardiovascular and neurological disorders. In the present study, the effects of SMS on axonal regeneration were investigated in the rat model given sciatic nerve injury. SMS treatment enhanced axonal regrowth into and the number of non-neuronal cells in the distal area after crush injury. GAP-43 protein levels were increased in the injured sciatic nerve compared to intact nerve and further upreguated by SMS treatment. GAP-43 protein was increased similarly in the dorsal root ganglion (DRG) at lumbar 4 - 6 by nerve injury and SMS treatment, suggesting GAP-43 induction at gene expression level. SMS-mediated increase in phospho-Erk1/2 protein was observed in the DRG as well as in the injured nerve implying its retrograde transport into the cell body as the process of lesion signal transmission. The present findings suggest that SMS may be involved in enhanced axonal regeneration via dynamic regulation of regeneration-associated proteins.

Accuracy evaluation of metal copings fabricated by computer-aided milling and direct metal laser sintering systems

  • Park, Jong-Kyoung;Lee, Wan-Sun;Kim, Hae-Young;Kim, Woong-Chul;Kim, Ji-Hwan
    • The Journal of Advanced Prosthodontics
    • /
    • 제7권2호
    • /
    • pp.122-128
    • /
    • 2015
  • PURPOSE. To assess the marginal and internal gaps of the copings fabricated by computer-aided milling and direct metal laser sintering (DMLS) systems in comparison to casting method. MATERIALS AND METHODS. Ten metal copings were fabricated by casting, computer-aided milling, and DMLS. Seven mesiodistal and labiolingual positions were then measured, and each of these were divided into the categories; marginal gap (MG), cervical gap (CG), axial wall at internal gap (AG), and incisal edge at internal gap (IG). Evaluation was performed by a silicone replica technique. A digital microscope was used for measurement of silicone layer. Statistical analyses included one-way and repeated measure ANOVA to test the difference between the fabrication methods and categories of measured points (${\alpha}$=.05), respectively. RESULTS. The mean gap differed significantly with fabrication methods (P<.001). Casting produced the narrowest gap in each of the four measured positions, whereas CG, AG, and IG proved narrower in computer-aided milling than in DMLS. Thus, with the exception of MG, all positions exhibited a significant difference between computer-aided milling and DMLS (P<.05). CONCLUSION. Although the gap was found to vary with fabrication methods, the marginal and internal gaps of the copings fabricated by computer-aided milling and DMLS fell within the range of clinical acceptance (< $120{\mu}m$). However, the statistically significant difference to conventional casting indicates that the gaps in computer-aided milling and DMLS fabricated restorations still need to be further reduced.

Enhanced Internal Quantum Efficiency and Light Extraction Efficiency of Light-emitting Diodes with Air-gap Photonic Crystal Structure Formed by Tungsten Nano-mask

  • Cho, Chu-Young;Hong, Sang-Hyun;Kim, Ki Seok;Jung, Gun-Young;Park, Seong-Ju
    • Bulletin of the Korean Chemical Society
    • /
    • 제35권3호
    • /
    • pp.705-708
    • /
    • 2014
  • We demonstrate the blue InGaN/GaN multiple quantum wells light-emitting diodes (LEDs) with an embedded air-gap photonic crystal (PC) which was fabricated by the lateral epitaxial overgrowth of GaN layer on the tungsten (W) nano-masks. The periodic air-gap PC was formed by the chemical reaction of hydrogen with GaN on the W nano-mask. The optical output power of LEDs with an air-gap PC was increased by 26% compared to LEDs without an air-gap PC. The enhanced optical output power was attributed to the improvement in internal quantum efficiency and light extraction efficiency by the air-gap PC embedded in GaN layer.

치과 캐드캠 시스템의 가공 방식에 따른 금속 코핑의 적합도 비교 (Comparison of the Marginal and Internal Gap of Metal Coping according to Processing Method of Dental CAD/CAM System)

  • 김동연;전진훈;박진영;김지환;김혜영;김웅철
    • 치위생과학회지
    • /
    • 제15권1호
    • /
    • pp.12-17
    • /
    • 2015
  • 본 연구에서는 치과 CAD/CAM 시스템을 이용하여 SM 가공 방식으로 코핑을 제작 후 주조한 금속 코핑과, AM 가공 방식으로 코핑을 제작 후 주조한 금속 코핑과의 변연 및 내면 적합도를 비교 평가하여 다음과 같은 결과를 얻었다. SM 가공 방식과 AM 가공 방식의 변연 적합도 부분에서는 $120{\mu}m$ 임상적 허용 범위에 존재하였다. SM 가공 방식과 AM 가공 방식의 변연 적합도 및 내면 적합도는 통계적으로 유의한 차이가 있는 것으로 나타났다(p<0.05). SM 가공 방식과 AM 가공 방식으로 제작된 두 그룹의 전체 적합도와 4부분 부위별 적합도 측정은 SM 가공 방식보다 AM 가공 방식이 우수하였다. 결론적으로 금속 코핑의 변연 및 내면 적합도는 SM 가공 방식보다 AM 가공 방식이 우수하였고, 그 결과 값들은 임상적 허용범위 안에 존재하였다. 앞으로 치과분야에서 AM 가공 방식에 관한 연구는 계속되어야 하며, 보다 완성도 높은 금속 코핑 제작이 가능하다고 생각된다.