• Title/Summary/Keyword: Internal filling

Search Result 197, Processing Time 0.028 seconds

Comparison between Myocardial Perfusion and Function in Rest State in Coronary Artery Disease - Dipyridamole $^{99m}Tc-MIBI$ SPECT and Rest Gated Blood Pool Scan - (관상동맥질환에서 휴식기의 심근관류 정도와 휴식기 심기능 변화의 비교 - Dipyridamole 부하 $^{99m}Tc-MIBI$ SPECT와 휴식기 Gated Blood Pool Scan -)

  • Choi, Chang-Woon;Lee, Dong-Soo;Kim, Sang-Eun;Bae, Sang-Kyun;Yang, Hyung-In;Chung, June-Key;Lee, Myoung-Mook;Lee, Myung-Chul;Park, Young-Bae;Seo, Jung-Don;Lee, Young-Woo;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.26 no.2
    • /
    • pp.265-273
    • /
    • 1992
  • Rest gated blood pool scan (Rest GBP scan) and dipyridamole $^{99m}Tc-MIBI$ SPECT were Performed in 34 patients with or suspected coronary artery disease. Both studies were performed within $2\sim32$ days (mean 8.1 days). A significant correlation was present between left ventricular ejection fraction (r= -0.7356, p<0.001) and peak ejection rate and peak filling rate in rest GBP scan and perfusion defect in MIBI SPECT. And there were acceptable correlations (0.05$26.2{\pm}10.8%$, severe hypokinesia, akinesia or dyskinesia in 16 regions: $78.2{\pm}23.7$, p<0.001). These data indicate there is a significant coupling between the degree of myocardial perfusion and the myocardial functional change in coronary artery disease.

  • PDF

Behavior of Walls of Open-cell Caissons Using Filler under Abnormally High Waves (고파랑 대비 채움재를 이용한 오픈 셀 케이슨의 전단 벽체 거동 분석)

  • Seo, Jihye;Won, Deokhee;Park, Woo-Sun
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.29 no.2
    • /
    • pp.83-91
    • /
    • 2017
  • In order to cope with the abnormally high waves during the storm surge due to climate change, various methods have been proposed for interlocking adjacent caissons to enhance stability of harbor structures. Among the methods, it was studied the method based on an open-cell caisson having reduction effect increasing the cohesion with adjunction caissons by filling materials such as crushed rocks in an inter-cell formed by two facing open-cells which consist of transverse walls. It is necessary to investigate the shear behaviors of an inter-cell to secure the stability using calculating shear forces on inter-cell under oblique wave loadings. It was analyzed the shear force share ratio with the length of internal and external wall and the number of internal walls. Numerical results show that 60~70% of the shear load is transmitted to adjacent caisson through the internal walls, more than 30% is through the external wall. It was applicable in the assumption that filling materials was uniformly distributed in inter-cells, and further studies were worth consideration on other conditions under construction.

A Case of Massive Pulmonary Thromboembolism in a Young Man Attribute to Computer Gaming (젊은 남자에서 장시간의 컴퓨터게임 후 발생한 대량 폐색전증 1예)

  • Kim, Hyun;Choe, Kang Hyeon;Lee, Ki Man;Shin, Yoon Mi
    • Tuberculosis and Respiratory Diseases
    • /
    • v.66 no.3
    • /
    • pp.211-215
    • /
    • 2009
  • Pulmonary thromboembolism occurs in old patients with risk factors, such as, immobilization, chronic medical disease, trauma, a hereditary hypercoagulable state, and others. However, we experienced a young man with a massive pulmonary thromboembolism attributed to immobilization due to computer gaming. The patient had been playing computer games in a seated position for at least five hour continually, and for twelve hours per day over a two-week period. The 36-year-old patient was transferred to our institute rule out the possibility of an acute myocardial infarction. Computer tomography revealed intraluminal filling defects in the distal main pulmonary artery and the left popliteal vein. He received thrombolytic therapy and subsequently recovered without complications. This case raises the possibility that prolonged computer gaming is a risk factor of thromboembolism in young adults.

Cardiac diastolic dysfunction predicts poor prognosis in patients with decompensated liver cirrhosis

  • Lee, Soon Kyu;Song, Myeong Jun;Kim, Seok Hwan;Ahn, Hyo Jun
    • Clinical and Molecular Hepatology
    • /
    • v.24 no.4
    • /
    • pp.409-416
    • /
    • 2018
  • Background/Aims: Left ventricular diastolic dysfunction (LVDD) is an early manifestation of cardiac dysfunction in patients with liver cirrhosis (LC). However, the effect of LVDD on survival has not been clarified, especially in decompensated LC. Methods: We prospectively enrolled 70 patients with decompensated LC, including ascites or variceal bleeding, at Daejeon St. Mary's Hospital from April 2013 to April 2015. The cardiac function of these patients was evaluated using 2D echocardiography with tissue Doppler imaging. The diagnosis of LVDD was based on the American Society of Echocardiography guidelines. The primary endpoint was overall survival. Results: Forty-four patients (62.9%) had LVDD. During follow-up (22.3 months), 18 patients died (16 with LVDD and 2 without LVDD). The survival rate was significantly lower in patients with LVDD than in those without LVDD (31.1 months vs. 42.6 months, P=0.01). In a multivariate analysis, the Child-Pugh score and LVDD were independent predictors of survival. Moreover, patients with a ratio of early filling velocity to early diastolic mitral annular velocity (E/e') ${\geq}10$ (LVDD grade 2) had lower survival than patients with E/e' ratio < 10. Conclusions: The presence of LVDD is associated with poor survival in patients with decompensated LC. Therefore, it may be important to monitor and closely follow LVDD patients.

Effect of carbonization temperature of AC/C composite electrode on electro double layer capacitor (탄화온도가 상이한 활성탄소 복합제 전극이 전기이중층 케페시터의 층방전 특성에 미치는 영향)

  • Jo, Young-Keun;Jung, Doo-Hwan;Kim, Chang-Soo;Park, So-Jin
    • Proceedings of the KIEE Conference
    • /
    • 1999.07d
    • /
    • pp.1821-1823
    • /
    • 1999
  • Carbon is an attractive material on electro double capacitor which depend on charge storage in the electrode/electrolyte interfacial double layer. Carbonaceous material for double layer capacitor can be obtained from carbon powder, fiber, film and porous carbon sheet. The capacitance of electrodes using an activated carbon was influenced by a filling density of the carbon, thickness and internal resistance of the electrode. In this study. to reduce internal resistance and increase electric conductivity of the electrode. activated carbon/carbon(AC/C) composite electrode was fabricated. The capacitors which have energy densities of 68F/g(at $30^{\circ}C$), 109F/g(at $60^{\circ}C$) and $68F/cm^3$(at $30^{\circ}C$), $111F/cm^3$(at $60^{\circ}C$) were fabricated by using AC/C composite electrodes.

  • PDF

A Study on FTA of Off-Site Packaged Hydrogen Station (Off-Site 패키지형 수소충전소의 FTA 분석)

  • SEO, DOO HYOUN;KIM, TAE HUN;RHIE, KWANG WON;CHOI, YOUNG EUN
    • Journal of Hydrogen and New Energy
    • /
    • v.31 no.1
    • /
    • pp.73-81
    • /
    • 2020
  • For the fault tree analysis (FTA) analysis of the packaged hydrogen filling station, the composition of the charging station was analyzed and the fault tree (FT) diagram was prepared. FT diagrams were created by dividing the causes of events into external factors and internal factors with the hydrogen event as the top event. The external factors include the effects of major disasters caused by natural disasters and external factors as OR gates. Internal factors are divided into tube tailer, compressor & storage tank, and dispenser, which are composed of mistakes in operation process and causes of accidents caused by parts leakage. In this study, the purpose was to improve the hydrogen station. The subjects of this study were domestic packaged hydrogen stations and FTA study was conducted based on the previous studies, failure mode & effect analysis (FMEA) and hazard & operability study (HAZOP). Top event as a hydrogen leaking event and constructed the flow of events based on the previous study. Refer to "Off shore and onshore reliability data 6th edition", "European Industry Reliability Data Bank", technique for human error rate prediction (THERP) for reliability data. We hope that this study will help to improve the safety and activation of the hydrogen station.

Glue Embolization of Ruptured Anterior Thalamoperforating Artery Aneurysm in Patient with Both Internal Carotid Arteries Occlusion

  • Lee, Jae-Il;Choi, Chang-Hwa;Ko, Jun-Kyeung;Lee, Tae-Hong
    • Journal of Korean Neurosurgical Society
    • /
    • v.49 no.5
    • /
    • pp.287-289
    • /
    • 2011
  • Thalamoperforating artery aneurysms are rarely reported in the literature. We report an extremely rare case of ruptured distal anterior thalamoperforating artery aneurysm which was treated by endovascular obliteration in a patient with occlusion of both the internal carotid arteries (ICAs) : A 72-year-old woman presented with severe headache and loss of consciousness. Initial level of consciousness at the time of admission was drowsy and the Glasgow Coma Scale score was 14. Brain computed tomography (CT) scan was performed which revealed intracerebral hemorrhage in right basal ganglia, subarachnoid hemorrhage, and intraventricular hemorrhage. The location of the aneurysm was identified as within the globus pallidus on CT angiogram. Conventional cerebral angiogram demonstrated occlusion of both the ICAs just distal to the fetal type of posterior communicating artery and the aneurysm was arising from right anterior thalamoperforating artery (ATPA). A microcatheter was navigated into ATPA and the ATPA proximal to aneurysm was embolized with 20% glue. Post-procedural ICA angiogram demonstrated no contrast filling of the aneurysm sac. The patient was discharged without any neurologic deficit. Endovascular treatment of ATPA aneurysm is probably a more feasible and safe treatment modality than surgical clipping because of the deep seated location of aneurysm and the possibility of brain retraction injury during surgical operation.

Biliary ascariasis misidentified as a biliary stent in a patient undergoing liver resection

  • Hochang Chae;Suk Won Suh;Yoo Shin Choi;Hee Ju Sohn;Seung Eun Lee;Jae Hyuk Do;Hyun Jeong Park
    • Parasites, Hosts and Diseases
    • /
    • v.61 no.2
    • /
    • pp.194-197
    • /
    • 2023
  • Ascaris lumbricoides causes one of the most common soil-transmitted helminthiases globally. The worms mostly infect the human small intestine and elicit negligible or nonspecific symptoms, but there are reports of extraintestinal ectopic ascariasis. We describe a rare case of biliary ascariasis mistaken for biliary stent in a 72-year-old female patient with a history of liver resection. She visited our outpatient clinic complaining of right upper quadrant pain and fever for the past week. She had previously undergone left lateral sectionectomy for recurrent biliary and intrahepatic duct stones 2 years ago. Besides mildly elevated gamma-glutamyl transferase levels, her liver function tests were normal. Magnetic resonance cholangiopancreatography revealed a linear filling defect closely resembling an internal stent from the common bile duct to the right intrahepatic bile duct. A live female A. lumbricoides adult worm was removed by endoscopic retrograde cholangiopancreatography (ERCP). Despite a significant decrease of the ascariasis prevalence in Korea, cases of biliary ascariasis are still occasionally reported. In this study, a additional case of biliary ascariasis, which was radiologically misdiagnosed as the biliary stent, was described in a hepatic resection patient by the worm recovery with ERCP in Korea.

Two Cases of Silicone-induced Pulmonary Embolism (Silicon 주사후 발생한 폐색전증 2예)

  • Jung, Bock-Hyun;Suh, Young-Ill;Lee, Jae-Myoung;Song, Sook-Hee;Kim, Ho-Joong;Lee, Myoung-Koo;Hyun, In-Gyu;Jung, Ki-Suck;Shin, Hyung-Sick
    • Tuberculosis and Respiratory Diseases
    • /
    • v.40 no.5
    • /
    • pp.610-615
    • /
    • 1993
  • Silicone (polydimethylsiloxane) has widely been used in breast augmentation and other cosmetic procedures. Despite the stability of its chemical nature, local and systemic adverse reactions associated with silicone have been reported. There were several patients who suffered from pulmonary embolism associated with injection of silicone. Silicone-induced pneumonitis and sudden death after subcutaneous injection of silicone has been also described. However, there is no case in the literature of clinically diagnosed silicone-induced pulmonary embolism in Korea. We experienced 2 women who developed respiratory symptoms after illicit subcutaneous injection of silicone for the purpose of colporrhaphy. One patient was admitted because of dyspnea, chest pain, hemoptysis and bilateral pulmonary infiltration after repeated injection of silicone. Pulmonary function test initially showed severe restrictive pattern and transbronchial lung biopsy disclosed numerous oil-like material filling the alveolar septal capillaries and macrophages. High resolution C. T., bronchoalveolar lavage, transbronchial lung biopsy and pulmonary angiogram disclosed abnormalities compatible with silicone fluid-induced pulmonary embolism. The other patient expired shortly after arrival in the emergency room. It is suggested that illicit injecion of silicone fluid carries serious respiratory problems and can induce pulmonary embolism followed by acute respiratory failure.

  • PDF

In-Situ Behaviors of Steel Frame-type Retaining Walls (조립식 강재틀 옹벽의 현장적응성 분석)

  • 박종배;임해식;박용부;나승민;정형식
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2003.06a
    • /
    • pp.93-101
    • /
    • 2003
  • Steel frame-type retaining walls(SFRW) are constructed by on site bolting of prefabricated steel frames and internal filling of materials such as rocks with the size of 150-300mm. Easy & fast construction, superior drainage performance and structural performance to rigorous site conditions are some of the merits of applying the SFRW to various construction sites. After the development of the structural details, a test construction of SFRW, with the height of 6m and 30m in length, was carried out at an apartment site. After completion, several months of monitoring was carried out on the structure to check displacement, tilting, settlement, soil pressures and drainage characteristics. The results of the structural behavior of SFRW along with its construction methods are presented in the paper.

  • PDF