• Title/Summary/Keyword: Internal exposure dose

Search Result 160, Processing Time 0.025 seconds

Artemisia capillaris Thunb. inhibits cell growth and induces apoptosis in human hepatic stellate cell line LX2

  • Kim, Young-Il;Lee, Jang-Hoon;Park, Seung-Won;Choi, In-Hwa;Friedman, Scott L.;Woo, Hong-Jung;Kim, Young-Chul
    • Advances in Traditional Medicine
    • /
    • v.10 no.4
    • /
    • pp.254-262
    • /
    • 2010
  • Artemisia capillaris (A. capillaries) is known to play roles in many cellular events, such as cell proliferation, differentiation, and apoptosis. We investigated the antifibrogenic efficacy of A. capillaris in the immortalized human hepatic stellate cell line LX2. Cell proliferation was determined by the MTT assay. Cell cycle was analyzed by the flow cytometry. Apoptotic cells were measured using a cell death detection ELISA. Caspase activity was detected by a colorimetric assay. The mRNA level of Bcl-2 and Bax mRNA were measured by real-time PCR. MEK and ERK protein were detected by Western blot analysis. We provide evidence that A. capillaris induces cell cycle arrest, apoptosis, and potently inhibits the mitogen-activated protein kinase pathway. A. capillaris inhibited cell proliferation of LX2 cells in a dose- and time-dependent manner, increased the apoptosis fraction at cell cycle analysis with an accompanying DNA fragmentation, and resulted in a significant decrease in Bcl-2 mRNA levels and an increase in Bax expression. Exposure of LX2 cells to A. capillaris induced caspase-3 activation, but co-treatment of A. capillaris with the pan-caspase inhibitor Z-VAD-FMK, and the caspase-3 inhibitor Z-DEVE-FMK, blocked apoptosis. A. capillaris down-regulated Mcl-1 protein levels and inhibited phosphorylation of MEK/ERK, suggesting that it mediates cell death in LX2 cells through the down-regulation of Mcl-1 protein via a MEK/ERK-independent pathway.

Elementary School in Gwangju Gwangsan Radon gas Density Measurement (광주광역시 광산구 소재 초등학교 라돈가스 농도 계측)

  • Ahn, Byungju;Oh, Jihoon
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.4
    • /
    • pp.211-216
    • /
    • 2014
  • Radium is rock or soil of crust or uranium of building materials after radioactivity collapse process are created colorless and odorless inert gas that accrue well in sealed space like basement. It inflow to lung circulate respiratory organ and caused lung cancer because of deposition of lung or bronchial tubes. In this study, the air in the elementary school classroom nongdoeul tonkatsu place of measured values were compared using the calculated annual internal radiation exposure. La tonkatsu exposure measured in primary school classroom at least five schools when you close the windows in the average floor 0.56mSv 2 floors ground floor windows when opened 0.384mSv 048mSv 3 floors, 2 floor levels of the same three layers 0.31mSv 0.296mSv the human exposure to radon and radiation on the first floor of 3 floors above ground in a lot of exposure was moderate. When you close the window from the first floor up 0.384mSv 056mSv 3 floors with a minimum annual radiation exposure due to natural radiation in the 16 to 23.3 percent minimum 2.4mSv accounted for. When I opened the window to the maximum annual radiation exposure 2.4mSv 0.296mSv 0.31mSv least a minimum of 12.3 to 12.91% accounted for Results suggest that more than five chodeunghakgyoeun La tonkatsu domestic radon measurements conducted below regulatory requirements and internal exposure has also fall within the normal range. People The less the radiation exposure to the human body because it reduces the impact in the classroom in elementary school vent windows often reduced to the maximum radon concentration in the air, if called tonkatsu be able to reduce radiation exposure for the immune system is weak and elementary will be helpful to experiment more in the future for the school authorities called tonkatsu investigation is done to him if the action to establish a more secure school building facilities is thought would be helpful.

Image Evaluation and Exposure Dose with the Application of Tube Voltage and Adaptive Statistical Iterative Reconstruction of Low Dose Computed Tomography (저 선량 전산화단층촬영의 관전압과 적응식 통계적 반복 재구성법 적용에 따른 영상평가 및 피폭선량)

  • Moon, Tae-Joon;Kim, Ki-Jeong;Lee, Hye-Nam
    • Journal of radiological science and technology
    • /
    • v.40 no.2
    • /
    • pp.261-267
    • /
    • 2017
  • The study has attempted to evaluate and compare the image evaluation and exposure dose by respectively applying filter back projection (FBP), the existing test method, and adaptive statistical iterative reconstruction (ASIR) with different values of tube voltage during the low dose computed tomography (LDCT). With the image reconstruction method as basis, chest phantom was utilized with the FBP and ASIR set at 10%, 20% respectively, and the change of tube voltage (100 kVp, 120 kVp). For image evaluation, back ground noise, signal-noise ratio (SNR) and contrast-noise ratio (CNR) were measured, and, for dose assessment, CTDIvol and DLP were measured respectively. In terms of image evaluation, there was significant difference in ascending aorta (AA) SNR and inpraspinatus muscle (IM) SNR with the different amount of tube voltage (p < 0.05). In terms of CTDIvol, the measured values with the same tube voltage of 120 kVp were 2.6 mGy with no-ASIR and 2.17 mGy with 20%-ASIR respectively, decreased by 0.43 mGy, and the values with 100 kVp were 1.61 mGy with no-ASIR and 1.34 mGy with 20%-ASIR, decreased by 0.27 mGy. In terms of DLP, the measured values with 120 kVp were $103.21mGy{\cdot}cm$ with no-ASIR and $85.94mGy{\cdot}cm$ with 20%-ASIR, decreased by $17.27mGy{\cdot}cm$ (about 16.7%), and the values with 100 kVp were $63.84mGy{\cdot}cm$ with no-ASIR and $53.25mGy{\cdot}cm$ with 20%-ASIR, a decrease by $10.62mGy{\cdot}cm$ (about 16.7%). At lower tube voltage, the rate of dose significantly decreased, but the negative effects on image evaluation was shown due to the increase of noise.

Construction of MIRD-type Korean Adult Male Phantom and Calculation of Dose Conversion Coefficients for Photon (한국 성인남성 MIRD형 모의피폭체 제작 및 광자 외부피폭 선량환산인자 산출)

  • Park, Sang-Hyun;Lee, Choon-Sik;Lee, Jai-Ki
    • Journal of Radiation Protection and Research
    • /
    • v.29 no.2
    • /
    • pp.97-104
    • /
    • 2004
  • MIRD-type Korean adult male phantom, 'KMIRD' was constructed to calculate Korean-specific dosimetric quantities for radiation protection consideration. The external shape of KMIRD was based on national physical standard data of Korean. KMIRD has thicket trunk than MIRD5 and arm models divided from trunk. The height and weight of the KMIRD are 171 cm and 63.8 kg. ICRP23 data were referred to constitute organs and tissues of KMIRD. However nine organs were constructed based on Korean reference data provided by Radiation Health Research Institute. In the present study, the MCNPX2.3 Monte Carlo transport code was combined with KMIRD to calculate dose conversion coefficients for photon in the energy range from 0.05 to 10 MeV. The simulated irradiation geometries are broad parallel photon beams in AP, PA, LLAT and RLAT direction. Absorbed dose conversion coefficients were compared with data calculated with MIRD5, MIRD-type phantom based on ICRP23 reference man. In some organs, the discrepancies between two phantoms amount up to nearly 30%. The effective doses conversion coefficients of KMIRD are lower than those of MIRD5. The dose discrepancies between two MIRD-type phantoms ate because of physical differences between Korean and Western, also geometric differences between two phantoms. KMIRD should be revised using the full set of Korean reference data of all organs. The developed MIRD-type Korean adult male phantom can be applied to dose assessment of internal exposure.

Evaluation on Organ Dose and Image Quality of Lumbar Spine Radiography Using Glass Dosimeter (유리선량계를 이용한 요추검사의 장기선량 및 영상의 평가)

  • Kim, Jae-Kyeom;Kim, Jeong-Koo
    • Journal of radiological science and technology
    • /
    • v.39 no.1
    • /
    • pp.1-11
    • /
    • 2016
  • The purpose of this study was to provide resources for medical exposure reduction through evaluation of organ dose and image resolution for lumbar spine around according to the size of the collimator in DR system. The size of the collimator were varied from $8^{\prime\prime}{\times}17^{\prime\prime}$ to $14^{\prime\prime}{\times}17^{\prime\prime}$ by 1" in AP and lateral projection for the lumbar spine radiography with RANDO phantom. The organ dose measured for liver, stomach, pancreas, kidney and gonad by the glass dosimeter. The image resolution was analyzed using the Image J program. The organ dose of around lumbar spine were reduced as the size of the collimator is decreased in AP projection. There were no significant changes decreasing rate whenever the size of the collimator were reduced 1" in the gonad. The organ dose showed higher on liver and kidney near the surface in lateral projection. There were decreasing rate of less than 5% in liver and kidney, but decreasing rate was 24.34% in the gonad whenever the size of the collimator were reduced 1". Organ dose difference for internal and external of collimator measured $549.8{\mu}Gy$ in the liver and $264.6{\mu}Gy$ in the stomach. There were no significant changes organ dose difference that measured $1,135.1{\mu}Gy$ in the gonad. Image Quality made no difference because SNR and PSNR were over than 30 dB when the collimator size is less than $9^{\prime\prime}{\times}17^{\prime\prime}$ on AP projection and $10^{\prime\prime}{\times}17^{\prime\prime}$ on lateral projection. Therefore, we are considered that the recommendations criterion for control of collimator were suggested in order to reduce unnecessary X-ray exposure and to obtain good image quality because lumbar spine radiography contains a lot of peripheral organs rather than other area radiography.

Effect of Gamisamgibopae-tang on the Growth and Apoptosis of A539 and NCI-H460 Human Lung Cancer Cells (A539 및 NCI-H460 인체 폐암세포의 증식 및 apoptosis 유도에 미치는 가미삼기보폐탕의 영향)

  • Kim, Jin-Young;Kim, Hyun-Joong;Jung, Kwang-Sik;Park, Cheol;Choi, Yung-Hyun;Kam, Cheol-Woo;Park, Dong-Il
    • The Journal of Internal Korean Medicine
    • /
    • v.29 no.1
    • /
    • pp.130-148
    • /
    • 2008
  • Objective : This study was designed to investigate the effect of the water extract of Gamisamgibopae-tang(GMSGBPT), an oriental herbal formulation, on the growth of NCI-H460 and A549 human non-small-cell lung cancer cell lines. Methods : Cytotoxicity and cell morphology were evaluated by MTT assay and inverted microscope, respectively. Apoptosis was detected using agarose gel electrophoresis and flow cytometer. The expression levels of mRNAs and proteins of target genes were determined by RT-PCR and western blot analyses, respectively Result and Conclusion : We found that exposure of A549 cells to GMSGBPT resulted in the growth inhibition in a dose-dependent manner as measured by MTT assay, but GMSGBPTdid not affect the growth of NCI-H460 cells. The anti-proliferative effect of GMSGBPT treatment in A549 cells was associated with morphological changes, formation of apoptotic bodies and DNA fragmentation, and flow cytometry analysis confirmed that GMSGBPT treatment increased the populations of apoptotic-sub G1 phase. Growth inhibition and apoptotic cell death by GMSGBPT were connected with a up-regulation of cyclin-dependent kinase inhibitor p21 (WAF1/CIP1) mRNA and protein in a tumor suppressor p53-independent fashion. However GMSGBPT treatment did not affect other growth regulation-related genes such as early growth response-1 (Egr-1), nonsteroidal anti-inflammatory drug (NSAID)-activated gene-1 (NAG-1), inducible nitric oxide synthase (iNOS), cyclooxygenases (COXs), telomere-regulatory factors in A549 orNCI-H460 cells. Taken together, these findings partially provide novel insights into the possible molecular mechanism of the anti-cancer activity of GMSGBPT.

  • PDF

Influencing Factors that Affect the Biological Monitoring of Workers Exposed to N,N-Dimethylformamide in Textile Coating Factories (섬유코팅업종사 근로자에서 디메틸포름아미드의 폭로에 의한 생물학적 모니터링에 영향을 미치는 인자)

  • Chung, In-Sung;Kim, Jong-Ghan;Choi, Sang-Kug;Bae, Jong-Youn;Lee, Mi-Young
    • Journal of Preventive Medicine and Public Health
    • /
    • v.39 no.2
    • /
    • pp.171-176
    • /
    • 2006
  • Objectives : The objective of this study is to assess the factors influencing biological monitoring of textile coating factory workers exposed to N,N-dimethylformamide(DMF). Methods : We studied 35 workers who were occupationally exposed to DMF from 9 textile coating factories. The study was carried out in two phases; summer and winter. While air concentration of DMF, temperature and humidity were assessed in order to monitor the atmospheric conditions, biological monitoring was done to determine the internal dose by analyzing the N-methylformamide(NMF) collected from urine at the beginning and end of the shift. Questionnaires and medical surveillance were also obtained during the two phases. Results : Median air concentrations of DMF in winter and summer were 1.85 ppm and 2.78 ppm respectively. Also the difference between the urinary NMF concentration at the beginning and end of the shift $({\Delta}NMF)$ was always significant in each season (P < 0.001). The correlations between log DMF in air, log end-of-shift urinary NMF (r=0.555, P < 0.001) and log ${\Delta}NMF$ (r = 0.444, P < 0.001) was statistically significant in summer. The temperature, humidity, a shift system and different styles of clothing worn were significantly different during the two phases. In a multivariate analysis, temperature and the concentration of DMF in the air were the main factors influencing biological monitoring of textile coating factory workers. Conclusions : Concerning more comprehensive prevention measures to reduce exposure for those workers occupationally exposed to DMF, dermal exposure conditions such as temperature and humidity together with the air concentration of DMF should be assessed and biological monitoring is necessary to reduce adverse health effects, especially during the summer.

Radiation Exposure of Operator in Intracoronary Radiotherapy Using $^{188}Re$ ($^{188}He$을 이용한 혈관내 방사선 치료시 시술자의 방사선 피폭 수준)

  • Chie, Eui-Kyu;Lee, Myung-Mook;Wu, Hong-Gyun
    • Journal of Radiation Protection and Research
    • /
    • v.25 no.4
    • /
    • pp.191-195
    • /
    • 2000
  • This study was undertaken to estimate the exposed dose of the medical personnel during the intracoronary radiotherapy procedure as a part of ongoing SPARE (Seoul National University Hospital Post-Angioplasty Rhenium) trial. Data of thirty-four patients among forty-two irradiated patients participating in this trial due to coronary artery stenosis were retrospectively analyzed. Intracoronary radiotherapy was delivered to the patient immediately after angioplasty ballooning. Prescribed dose was 17 Gy to media of the diseased artery and was delivered with $^{188}Re$ filled balloon catheter. Dosimetry was carried out with GM counter at eight different points. Ten centimeter and forty centimeter from the patient's heart were selected to represent maximum and whole-body exposed dose of the operator, respectively. Median delivered dose was 111.6 mCi with average treatment time of 576 seconds. Average exposed dose rate at 10 cm and 40 cm from the patient's heart were 0.43 mSv/hr and 0.30 mSv/hr, respectively. Average exposed doses per treatment were 0.07 mSv and 0.05 mSv for 10 cm and 40 cm from the patient's heart, respectively. Exposed doses measured are much lower than recommended limit of 50 mSv for radiation workers or 1 mSv for general population in ICRP-60. This study proves that current method of intracoronary radiotherapy incorporated in this trial is very safe regarding radiation protection.

  • PDF

Effect of Rhizoma gastrodiae on glucose oxydase induced neurotoxicity in cultured mouse spinal dorsal root ganglion neurons

  • Park, Seung-Taeck;Park, Yang-Kyu;Park, Jae-Hwang;Cho, Kwang-Ho;Ryu, Do-Gon;Jeon, Byung-Hoon;Shin, Min-Kyo;Han, Du-Seok;Cho, Nam-Su;Shin, Dong-Min
    • Advances in Traditional Medicine
    • /
    • v.1 no.1
    • /
    • pp.64-70
    • /
    • 2000
  • Effects of Rhizoma gastrodiae on glucose oxidase-induced neurotoxicity was investigated in cultured newborn mouse spinal dorsal root ganglion(DRG) neurons that were treated in the media with or without glucose oxidase. In addition, the protective effect of Rhizoma gastrodiae extract against glucose oxidase-induced neurotoxicity was examined. Cytotoxic values were expressed as a percentage of number of living cells by 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide (MTT) assay. In this paper, exposure of neurons to glucose oxidase resulted in a significant call death in a dose- and time-dependent manners in DRG neuron cultures. The decrease in cell viability induced by the glucose oxidase was blocked by Rhizoma gastrodiae extract. These results indicate that the neuroprotective effect of Rhizoma gastrodiae extract against glucose oxidase-induced neurotoxicity may result from a prevention or attenuation of oxidative damage induced by glucose oxidase.

  • PDF

Using machine learning for anomaly detection on a system-on-chip under gamma radiation

  • Eduardo Weber Wachter ;Server Kasap ;Sefki Kolozali ;Xiaojun Zhai ;Shoaib Ehsan;Klaus D. McDonald-Maier
    • Nuclear Engineering and Technology
    • /
    • v.54 no.11
    • /
    • pp.3985-3995
    • /
    • 2022
  • The emergence of new nanoscale technologies has imposed significant challenges to designing reliable electronic systems in radiation environments. A few types of radiation like Total Ionizing Dose (TID) can cause permanent damages on such nanoscale electronic devices, and current state-of-the-art technologies to tackle TID make use of expensive radiation-hardened devices. This paper focuses on a novel and different approach: using machine learning algorithms on consumer electronic level Field Programmable Gate Arrays (FPGAs) to tackle TID effects and monitor them to replace before they stop working. This condition has a research challenge to anticipate when the board results in a total failure due to TID effects. We observed internal measurements of FPGA boards under gamma radiation and used three different anomaly detection machine learning (ML) algorithms to detect anomalies in the sensor measurements in a gamma-radiated environment. The statistical results show a highly significant relationship between the gamma radiation exposure levels and the board measurements. Moreover, our anomaly detection results have shown that a One-Class SVM with Radial Basis Function Kernel has an average recall score of 0.95. Also, all anomalies can be detected before the boards are entirely inoperative, i.e. voltages drop to zero and confirmed with a sanity check.