Radiation Exposure of Operator in Intracoronary Radiotherapy Using $^{188}Re$

$^{188}He$을 이용한 혈관내 방사선 치료시 시술자의 방사선 피폭 수준

  • Chie, Eui-Kyu (Department of Therapeutic Radiology, Seoul National University College of Medicine) ;
  • Lee, Myung-Mook (Internal medicine, Seoul National University College of Medicine) ;
  • Wu, Hong-Gyun (Department of Therapeutic Radiology, Seoul National University College of Medicine, Institute of Radiation Medicine, Research Center, Seoul National University)
  • 지의규 (서울대학교 의과대학 치료방사선과학교실) ;
  • 이명묵 (서울대학교 의과대학 내과학교실) ;
  • 우홍균 (서울대학교 의과대학 치료방사선과학교실, 서울대학교 의학연구원 방사선의학연구소)
  • Published : 2000.12.30

Abstract

This study was undertaken to estimate the exposed dose of the medical personnel during the intracoronary radiotherapy procedure as a part of ongoing SPARE (Seoul National University Hospital Post-Angioplasty Rhenium) trial. Data of thirty-four patients among forty-two irradiated patients participating in this trial due to coronary artery stenosis were retrospectively analyzed. Intracoronary radiotherapy was delivered to the patient immediately after angioplasty ballooning. Prescribed dose was 17 Gy to media of the diseased artery and was delivered with $^{188}Re$ filled balloon catheter. Dosimetry was carried out with GM counter at eight different points. Ten centimeter and forty centimeter from the patient's heart were selected to represent maximum and whole-body exposed dose of the operator, respectively. Median delivered dose was 111.6 mCi with average treatment time of 576 seconds. Average exposed dose rate at 10 cm and 40 cm from the patient's heart were 0.43 mSv/hr and 0.30 mSv/hr, respectively. Average exposed doses per treatment were 0.07 mSv and 0.05 mSv for 10 cm and 40 cm from the patient's heart, respectively. Exposed doses measured are much lower than recommended limit of 50 mSv for radiation workers or 1 mSv for general population in ICRP-60. This study proves that current method of intracoronary radiotherapy incorporated in this trial is very safe regarding radiation protection.

현재 서울대학교병원에서 진행중인 연구의 일환으로 혈관 내 방사선치료 시 시술자의 방사선피폭 정도 및 위험성에 대해 알아보고자 연구를 시행하였다. 심장혈관 폐색으로 연구에 포함되어 방사선치료른 시행 받은 42명의 환자 중 측정이 완벽한 34명의 자료를 토대로 분석을 시행하였다. 혈관내 방사선치료는 관상동맥성형술 직후 풍선도자법을 이용하여 대상 동맥의 중막에 17 Gy를 조사하였다. 사용된 동위원소는 $^{188}Re$이었으며 GM측정기로 각기 다른 8점에서 피폭선량을 측정하였다. 환자의 심장부위에서 10cm, 40cm 떨어진 지점을 시술자의 최대피폭량, 전신피폭량의 기준으로 삼았다. 치료선량의 중앙값은 111.6 mCi이었고 중앙치료시간은 576초였다. 환자 심장부위에서 l0cm, 40cm 지점의 평균 피폭 선량율은 0.43 mSv/hr, 0.30 mSv/hr 이었고, 각 지점에서의 시술 당 평균 피폭 선량은 0.07 mSv, 0.05 mSv 이었다. 이 수치는 ICRP-60나 과학기술부 고시에서 권고하고 있는 한계 피폭선량보다 훨씬 적은 값으로 현재 저울대학교병원에서 시행하고 있는 혈관내 방사선 치료법은 방사선방어 면에서 매우 안전한 방법임을 확인할 수 있었다.