• Title/Summary/Keyword: Internal energy distribution

Search Result 239, Processing Time 0.029 seconds

Some characteristics of an interior explosion within a room without venting

  • Feldgun, V.R.;Karinski, Y.S.;Yankelevsky, D.Z.
    • Structural Engineering and Mechanics
    • /
    • v.38 no.5
    • /
    • pp.633-649
    • /
    • 2011
  • The paper presents a study aimed at understanding some characteristics of an interior explosion within a room with limited or no venting. The explosion may occur in ammunition storage or result from a terrorist action or from a warhead that had penetrated into this room. The study includes numerical simulations of the problem and analytical derivations. Different types of analysis (1-D, 2-D and 3-D analysis) were performed for a room with rigid walls and the results were analyzed. For the 3D problem the effect of the charge size and its location within the room was investigated and a new insight regarding the pressure distribution on the interior wall as function of these parameters has been gained. The numerical analyses were carried out using the Eulerian multi-material approach. Further, an approximate analytical formula to predict the residual internal pressure was developed. The formula is based on the conservation law of total energy and its implementation yields very good agreement with the results obtained numerically using the complete statement of the problem for a wide range of explosive weights and room sizes that is expressed through a non-dimensional parameter. This new formula is superior to existing literature recommendations and compares considerably better with the above numerical results.

Performance Comparison of Regularization Methods in Electrical Resistance Tomography (전기 저항 단층촬영법에서의 조정기법 성능비교)

  • Kang, Suk-In;Kim, Kyung-Youn
    • Journal of IKEEE
    • /
    • v.20 no.3
    • /
    • pp.226-234
    • /
    • 2016
  • Electrical resistance tomography (ERT) is an imaging technique where the internal resistivity distribution inside an object is reconstructed. The ERT image reconstruction is a highly nonlinear ill-posed problem, so regularization methods are used to achieve desired image. The reconstruction outcome is dependent on the type of regularization method employed such as l2-norm, l1-norm, and total variation regularization method. That is, use of an appropriate regularization method considering the flow characteristics is necessary to attain good reconstruction performance. Therefore, in this paper, regularization methods are tested through numerical simulations with different flow conditions and the performance is compared.

AKARI Observations for 8 dense molecular cores

  • Kim, Gwanjeong;Lee, Chang Won;Kim, Mi-Ryang;Kim, Seungun
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.37 no.2
    • /
    • pp.100.1-100.1
    • /
    • 2012
  • We present results of AKARI observations toward 8 dense molecular cores which are previously known to be "starless". These cores show some spectral features which may imply characteristic internal motions. The observations were carried out at 8 bands (3, 4, 7, 11, 65, 90, 140, and 160 micron) with IRC and FIS instruments equipped in the AKARI. The archive data of 2MASS and Spitzer were also utilized. We found that 1 (L1582A) of 8 cores has a few embedded young stellar objects (YSOs) while the rest of them are still starless. The YSOs found in L1582A are identified by the slope of the spectral energy distribution or by the AKARI color-color diagram. The unusually broad linewidth toward L1582A, which is twice broader than one of starless cores, is also consistent with the existence of protostars in this core. The physical environment and evolution of the other "starless" cores where any AKARI point source is not detected will be discussed with help of their molecular line observations.

  • PDF

Optical Design of a 2-kW-Level Laser Head for Metal 3D-Printing Systems (금속 3D 프린팅 시스템 구축을 위한 2 kW 급 레이저헤드 광학설계)

  • Lee, Joohyung
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.21 no.1
    • /
    • pp.90-94
    • /
    • 2022
  • Metal 3D-printing technology enables the manufacture of complex features or internal structures, which is not possible in fabrication by conventional cutting methods. The most successful types of metal 3D printing have been powder bed diffusion and directed energy deposition, which use laser heads exploiting high-power laser sintering metal powder. In this study, a cost-effective optical design was proposed for a 2-kW-level fiber laser head. Only two commercial lenses, a beamsplitter and a window, are used in the laser head, satisfying the technological requirements. According to the optical design, the spot size was 2.54 mm, and the stand-off distance from the laser head was 295 mm. The intensity distribution was Gaussian. Thus, smooth power sintering was possible without any laser spot marks. Monte Carlo analysis was employed to verify the consistency of the optical performance under conventional assembly tolerance.

Fungal Load of Groundwater Systems in Geographically Segregated Islands: A Step Forward in Fungal Control

  • Joong Hee Cho;Nam Soo Jun;Jong Myong Park;Ki In Bang;Ji Won Hong
    • Mycobiology
    • /
    • v.50 no.5
    • /
    • pp.345-356
    • /
    • 2022
  • The fungal distribution, diversity, and load were analyzed in the geographically segregated island groundwater systems in Korea. A total of 79 fungal isolates were secured from seven islands and identified based on the internal transcribed spacer (ITS) sequences. They belonged to three phyla (Ascomycota, Basidiomycota, and Chlorophyta), five classes, sixteen orders, twenty-two families, and thirty-one genera. The dominant phylum was Ascomycota (91.1%), with most fungi belonging to the Cladosporium (21.5%), Aspergillus (15.2%), and Stachybotrys (8.9%) genera. Cladosporium showed higher dominance and diversity, being widely distributed throughout the geographically segregated groundwater systems. Based on the diversity indices, the genera richness (4.821) and diversity (2.550) were the highest in the groundwater system of the largest scale. As turbidity (0.064-0.462) increased, the overall fungal count increased and the residual chlorine (0.089-0.308) had low relevance compared with the total count and fungal diversity. Cladosporium showed normal mycelial growth in de-chlorinated sterilized samples. Overall, if turbidity increases under higher fungal diversity, bio-deterioration in groundwater-supplying facilities and public health problems could be intensified, regardless of chlorine treatment. In addition to fungal indicators and analyzing methods, physical hydrostatic treatment is necessary for monitoring and controlling fungal contamination.

Study on the Application of V2G for Electric Vehicles in Korea Using Total Cost of Ownership Analysis (총소유비용 분석을 이용한 전기차의 V2G 도입에 대한 연구)

  • Kim, Younghwan;Lee, Jae-Seung
    • Journal of Energy Engineering
    • /
    • v.24 no.2
    • /
    • pp.129-143
    • /
    • 2015
  • Increasing concerns on climate change and energy security accelerated policies to reduce green-house gas emission, especially from the transportation sector. Electric vehicle (EV) has been on the spotlight to deal with such environmental issue and V2G (Vehicle-to-Grid) technology began to draw attentions as an alternative to reduce ownership costs while contributing to an efficient and decentralized power grid. This study conducts a scenario analysis on total cost of ownership of EV under V2G scheme and compare with non-V2G EV and Internal Combustion Engine (ICE) vehicle. As result, V2G service is expected to provide an annual average profit of $210 to EV users willing to reverse flow its residual power in the battery. The profit from V2G service leaves a margin of $4,530 over operational lifetime, compared with $2,420 cost of charge for non-V2G EV. In summary, total cost of ownership of V2G-capable EV was 6.2% less than non-V2G EV and 10.2% higher than ICE vehicle. The results confirm a comparative economic advantage of operating EV under V2G scheme. Increased number of EVs with V2G service has shown to provide positive effects to power industry for valley filling in load distribution, thus, favorably increasing the overall economic feasibility.

An Experimental Study on Internal Decontamination Radiocobalt (Radiocobalt의 체내 오염(汚染)에 대(對)한 제염효과(除染效果))

  • Chung, In-Yong;Kim, Tae-Hwan;Chung, Hyun-Woo;Chin, Soo-Yil;Yun, Taik-Koo
    • Journal of Radiation Protection and Research
    • /
    • v.13 no.1
    • /
    • pp.31-41
    • /
    • 1988
  • In case of the acute intake of radionuclide, an early medical treatment may be necessary, but the little is established the procedures to decontaminate the victims of internal contamination in Korea. The purpose of the present investigation is to study chemical agents to remove radiocobalt from the victims and to provide a more reliable procedure for the treatment. The removals of radiocobalt from the NIH-CGP)mice injected intraperitoneally with $1{\mu}Ci$ of $^{58}Co$ as $CoCl_2$ were investigated with doses of either $CaNa_3$ DTPA 8.4mg/0.2ml saline, $CoNa_3$ DTPA 8.4mg/0.2ml saline, or saline 5ml. The radioactivity was determined by MCA and Ge-detector on 4, 8, 12, 48 hours and 7 days for the whole body, organ distribution and urine excretion. Six mice per each group were sacrificed for the measurement of cobalt retention in the parenchymal tissue. The cobalt trisodium chelate had a pronounced effect on reducing the whole body retention and increasing the excretion rate. Regarding to the systemic protective effects, $CoNa_3$ DTPA, $CaNa_3$ DTPA and saline were effected significantly in order. In conclusion, the extrapolations from these results to human were suggested that the rapid administration of cobalt trisodium chelate and an amount of saline to the contaminated person after internal contamination of radiocobalt were markedly increasing the decontamination effects.

  • PDF

Analysis of Temperature Distribution and slip in Rapid Thermal Processing (급속 열처리시 실리콘 웨이퍼의 온도분포와 슬립 현상의 해석)

  • Lee, Hyouk;Yoo, Young-Don;Earmme, Youn-Young;Shin, Hyun-Dong;Kim, Choong-Ki
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.4
    • /
    • pp.609-620
    • /
    • 1992
  • A numerical solution of temperature and thermally induced stress in a wafer during rapid thermal processing (R.T.P) is obtained, and an analysis of onset and propagation of slip is performed and compared with experiment. In order to calculate temperature distribution of a wafer in R.T.P system, heat conduction equation that incorporated with radiative and convective heat transfer model is solved, and the solution of the equation is calculated numerically using alternating direction implicit (A.D.I) method. In dealing with radiative heat transfer, a partially transparent body that absorbs the radiation energy is assumed and this transparent body undergoes multiple internal reflections and absorptions. Two dimensional (assuming plane stress) thermoelastic constitutive equation is used to calculate thermal stress induced in a wafer and finite element method is employed to solve the equation numerically. The stress resolved in the slip directions on the slip planes of silicon is compared with the yield stress of silicon in order to predict the slip. The result of the analysis shows that the wafer temperature at which slip occurs is affected by the heating rate of the R.T.P system. It is observed that once slip occurs in the wafer, the slip grows.

Globalization of Korean Electrical Installations Standards and Codes Based on Comparison of IEC 60364 with NFPA 70(NEC)

  • Ki, Chung-Young;Ro, Kwak-Hee;Seop, Shin-Hyo;Joo, Nam-Taik
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2002.11a
    • /
    • pp.280-287
    • /
    • 2002
  • Most Technological laws of Korea are almost identical to those of Japan. Electricity was not introduced to Korea until lighting ceremony in Kyong-Bok palace observed in 1887. Since Korea was annexed to Japan in 1910, Korea have applied Japanese law and regulations made by Chosun government-general. And public works were under Japan control. Korea accepted adopted the power plants of America, codes of NESC, ASME / ANSI, MEMA while Japan accepted or adopted only IEC. Our generation distribution system takes American style while our consumer side takes Japanese style. As global trade system was transferred GATT into WTO, the technological standards, certification, construction and testing are in harmony internationally. The WTO / TBT agreement came in effect after 12th, April, 1979. The sections in the agreement require the members to exchange their own standards and codes for the harmonized ones by degree. The Korean distribution system has a strong resemblance to American system so that the internal engineers are confused in application of the relevant standards. IEC60364 and NEC are technologically similar but practically unconvertible because both have their different originality, that is to say Europe and USA. This paper deals with the fundamental elements of electrical safety system on review of IEC 60364 and NEC. This paper considers how engineers should apply IEC60364 and NFPA 70(NEC) based on all-the-way review of them.

  • PDF

Quantitative Analysis of Skarn Ore Using 3D Images of X-ray Computed Tomography (3차원 X-ray 단층 화상을 이용한 스카른 광석의 정량분석 연구)

  • Jeong, Mi-Hee;Cho, Sang-Ho;Jeong, Soo-Bok;Kim, Young-Hun;Park, Jai-Koo;Kaneko, Katsuhiko
    • Journal of the Mineralogical Society of Korea
    • /
    • v.23 no.3
    • /
    • pp.211-217
    • /
    • 2010
  • A micro-focus X-ray computed tomography (CT) was employed to determine quantitative phase analysis of skarn Zn-Pb-Cu ore by nondestructive visualization of the internal mineral distribution of a skarn ore. The micro CT images of the ore were calibrated to remove beam hardening artifacts, and compared with its scanning electron microscope (SEM) images to set the threshold of CT number range covering sulfide ore minerals. The volume ratio of sulfide and gangue minerals was calculated 20.5% and 79.5%, respectively. The quantitative 3D X-ray CT could be applied to analyse the distribution of economic minerals and their recovery.