• Title/Summary/Keyword: Internal energy

Search Result 2,135, Processing Time 0.032 seconds

3D mechanical model based pulmonary nodule segmentation in CT images (CT영상용 3차원 역학 모델 기반 폐 결절 분할 방법)

  • Yoon, Ji-Seok;Choi, Tae-Sun
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.8 no.4
    • /
    • pp.319-326
    • /
    • 2015
  • In this paper, a 3D mechanical model based on pulmonary nodule segmentation method is proposed. The proposed method has three main parts. First, an initial 3D mechanical model is generated. The model is made up of many triangle elements resulting in forming whole shape of the model as sphere. Second, points of the model are deformed, and finally internal and external energies according to each deformation are calculated. The internal energy is determined by the model shape, and the external energy is determined by intensity. After the model is deformed, the process of searching the minimum energy generated by the deformation is executed repetitively. If the model energy converges, the nodule is segmented by using the proposed model. The proposed method greatly improves the result compared with conventional methods.

A Literatual Study on the NAM-SUNG-BUL-YOUK (남성부육증(男性不育症)에 대(對)한 문헌적(文獻的) 고찰(考察))

  • Oh, HyungSook;Kim, Yong-Seong;Kim, ChulJung
    • Journal of Haehwa Medicine
    • /
    • v.7 no.2
    • /
    • pp.497-508
    • /
    • 1999
  • In the literatual study on the NAM-SUNG-BUL-YOUK, the results were obtained. 1. NAM-SUNG-BUL-YOUK is mainly caused by deficiency of kidney jung, and is subsiderly caused by deficiency of kidney yang, deficiency of vital energy and blood, depression of vital energy, stagnation of wetness and phlegm, wetness and heat, trauma, and so on. 2. Increasing kidney jung is the main method of the treatment of NAM-SUNG-BUL-YOUK. Warmming kidney and strengthening kidney yang, increasing both vital energy and blood, solving of liver energy, promotion of blood circuation to get rid of blood stasis, drying wetness and removing phlegm, cooling wetness and heat, use the fragrance of smelling hot and wram, etc. are also used to treat it. 3. NAM-SUNG-BUL-YOUK is prescripted as follows : Chanyukdan and Yukmigiwhangtang are used for the deficiency of Sin jung(賢精); Jangchunkwangsadan, Oujayeonjongwhan, Youguiyeum, and Palmigiwhangtang are used for the deficiency of Sin yang(賢陽); Daebowonjeon and Palmultang are used for the deficiency of energy and blood; Sihosogansan is used for the depression of liver energy; Dodamtang and Yijintang and Singitang are used for the stagnation of phlegm; and finally, Yongdamsagantang and Bihaebunchungyeum are used for wetness and heat. Above literatual study shows that NAM-SUNG-BUL-YOUK can be cured with highly ratio. It is accomplished by the conduction of appropriate herbs, acupunctures and moxibustions through method of oriental medicine.

  • PDF

Novel anti-obesity effects of alpha-lipoic acid mediated by suppression of hypothalamic AMP-activated protein kinase

  • Lee, Ki-Up
    • Proceedings of the Korean Society of Applied Pharmacology
    • /
    • 2003.11a
    • /
    • pp.3-4
    • /
    • 2003
  • Body weight is maintained at a relatively constant level over days and months despite variability in food intake and physical activity. To achieve energy homeostasis, the hypothalamus receives information related to energy surplus or shortage from the periphery and controls food intake and energy expenditure. Leptin, an adipocyte derived hormone, is a principal mediator that signals the brain about the stored energy status. Increased leptin signaling in the brain prevents excess energy stores by suppressing food intake and increasing energy expenditure. In addition, insulin and nutrients themselves, such as glucose and free fatty acids, also regulate food intake.

  • PDF

A Study of Motor Expertise about Kinematic and Kinetic Characteristics of Lower Extremity in the Seokmun Ilwol Martial Art Yin-yang Bo Gait Pattern (석문일월무예 음양보법의 숙련성에 따른 보행 패턴의 하지 운동학 및 운동역학적 특성)

  • Park, Bok-Hee;Kim, Ky-Hyoung
    • Korean Journal of Applied Biomechanics
    • /
    • v.24 no.3
    • /
    • pp.239-248
    • /
    • 2014
  • The purpose of this study was to quantify kinematic and kinetic characteristics of Yin-yang Bo gait according to their motor expertise, one of the Seokmun Ilwol martial art gait patterns. Yin-yang Bo gait pattern shows initial forefoot contact instead of heel contact, and increased time of stance phase time, internal-external rotation of ankle-knee-hip joints and pelvic. It aims to produce and store the more energy through continuous homeostasis of center of gravity (COG) and performance of stretch-shortening cycle. Some of these characteristics also were similar to the gait modification strategies for reducing knee adduction moment such as toe-out progression, medial thrust, internal rotation of hip joint. To identify the characteristics, four factors of expert Yin-yang Bo gait performance group were compared to that of none expert group; 1) angles of COG displacement and rotation 2) distal joint pre-rotation in internal-external rotation of ankle-knee-hip joints and pelvic, 3) invariability pelvic potential and pelvic segment total energy 4) knee abduction moment. Six healthy(three male) subjects participated in the experiment to perform Yin-yang gait pattern. Three-dimensional and force plate data were collected. Kinematic and kinetic data were compared between two groups using t-tests. Results showed that 1) the peak point of COG internal rotation angle was reduced in expert group, 2) kneeexternal and hip joint -internal and pelvic rotation angle peak frames were more near points in expert group.

Assessment of Daylight Environment on Light Pipe System Under Different Solar Position (태양의 위치에 따른 광파이프 시스템의 실내 주광환경평가)

  • Shin, Hwa-Young;Kim, Jeong-Tai
    • Journal of the Korean Solar Energy Society
    • /
    • v.28 no.6
    • /
    • pp.78-86
    • /
    • 2008
  • The aim of this paper is to show the daylight environment of a light pipe system according to sun movement. A light pipe system has been mounted on the roof of the windowless full scale model: the solar spot has diameter of 0.65m and is 1.3m long, giving an aspect ratio of 1:2. The full scale model was installed on the rooftop of the SHINAN apartment in Yongin city that has no obstructions against sunlight. The test room is equipped with sensors for the measurements of the internal illuminance and has an area of 6m(W)$\times$6m(D)$\times$4m(H). The system has been monitored with a data-logger to evaluate the cumulative distribution of illuminance on a floor-plane from 16th, April to 29th, May, 2008 over one month and selected clear sky condition. For the daylight performance of floor area, the totally 49 measuring points has been used to determine the internal illuminance and an HP datalogger(HP34970A) records the measurements for one consecutive month. The horizontal external illuminance has been measured with two outdoor sensors. This paper presents the results of monitoring light pipe system with internal/external illuminance ratio and cumulative frequency distribution of floor-plane illuminance are discussed The results show that lightpipe is proficient device for introducing daylight into the building. However It provided different daylight indoor environment with wide or narrow Interquatile range of illuminance, internal/external illuminance ratio and cumulative frequency distribution according to solar positions under suuny sky condition. For more achieving the improvement of lightpipes also include energy savings, user visual comfort with various indicators; seasonal solar height, room and lightpipes geometries.

Evaluation on the Solar Heat Gain Coefficient of Glazing System installed in internal shading device by experiments according to the NFRC 201 (NFRC 201 실험방법에 의한 내부 차양장치가 적용된 창호의 일사획득계수 평가)

  • Lim, Jae-Han;Song, Seung-Yeong
    • Journal of the Korean Solar Energy Society
    • /
    • v.30 no.3
    • /
    • pp.47-54
    • /
    • 2010
  • Recently the researchers has been interested in the development of the high performance windows such as solar control window using automatic shading devices, air-flow window, selective coating window. In order to assess the energy performance of total fenestration system, the net energy gains or losses through the glazings and windows should be evaluated. It depends on the thermal transmittance (U-value) and the total solar energy transmittance (SHGC, g-value). This study aims to measure the solar heat gain coefficient according to the NFRC 201 standard test method. In results, we could find the result of different SHGC of the glazing system with a different slat angles. The SHGC in case of $90^{\circ}$ of internal slat angle with regard to the window surface is about 0.56, that in case of $45^{\circ}$ is about 0.49 and that in case of $0^{\circ}$ is about 0.33. Significant dependence on the solar radiation intensity and incident angle was found in comparison of the measured and simulated SHGC.

Application of Piezoelectric Smart Structures for Statistical Energy Analysis (압전 지능 구조물을 이용한 통계적 에너지 해석 기법)

  • 김재환;김정하;김재도
    • Journal of KSNVE
    • /
    • v.11 no.2
    • /
    • pp.257-264
    • /
    • 2001
  • In this research, piezoelectric smart structures are applied for SEA(Statistical Energy Analysis), which is well known approach for high frequency analysis. A new input power measurement based on piezoelectric electrical power measurement is proposed and compared with the conventional method in SEA. As an example, a simple aluminum beam on which piezoelectric actuator is attached is considered. By measuring the electrical impedance and electrical current of the piezoelectric actuator, the electrical power given on the actuator is found and this is In turn converted into the mechanical energy. From the measured value of the stored energy of the beam, the Internal loss factor is calculated and this value shows a good agreement with that given by the conventional method as well as the theoretical value. To compare the coupling loss factor, L-shape beam system which consists of a aluminum beam subsystem and a steel beam subsystem coupled by three pin is taken as second example. The input power and stored energy of each subsystem are found by the proposed approach. The coupling loss factor found by the electrical input power obtained from the piezoelectric actuator exhibits similar trend to the value found by the conventional method as well as the theoretical value. In conclusion, the use of SEA for high frequency application of piezoelectric smart structures is Possible. Especially, the input power that is essential for SEA can be found accurately by measuring the electrical input power of the piezoelectric actuator.

  • PDF

Derivation of Appropriate Thermal Transmittance Alternatives in Apartment Remodeling (아파트의 리모델링시 적합한 열관류율 대안의 도출)

  • Kim, Song-Do;Lee, Sang-Hoon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.8
    • /
    • pp.4012-4018
    • /
    • 2013
  • This paper proposes an energy conservation scheme when apartment remodeling is provided, which analyzes the energy conservation techniques that are suitable for overseas passive houses. Subsequently, a passive solution that is more suitable for our country is derived. In order to examine the energy saving rate applying to passive solution, it evaluates the energy saving rate of 5 specific cases by taking advantage of internal building energy efficiency rating certification system, classifies them and analyzes them. Finally, a rational alternative is devised, and then which is implemented in the internal apartment housing remodeling project. This scheme can save 40% of the energy in comparison with typical apartment building.

A Numerical Study on the Flow Uniformity according to Chamber Shapes Used for Test of the Semi-Conductor Chip (반도체 칩 테스트용 챔버 형상에 따른 유동 균일성에 대한 수치적 연구)

  • LEE, DAEGYU;MA, SANG-BUM;KIM, SUNG;KIM, JEONG-YEOL;KANG, CHAEDONG;KIM, JIN-HYUK
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.31 no.5
    • /
    • pp.480-488
    • /
    • 2020
  • This study was conducted to improve the flow uniformity inside the chip tester through changing the flow path formation according to the inlet and outlet position of chamber. The internal flow and velocity distributions of the modified chamber models (Cases 1-3) were compared with the reference chamber model through three-dimensional Reynolds-averaged Navier-Stokes equations with k-ε turbulence model. The modified chamber models showed the superior flow uniformity characteristics compared to the reference chamber model. To investigate the flow uniformity in the chip tester, the standard deviation of the velocity was defined and compared. Through the internal flow analysis and assesment of the standard deviation, Case 2 among the test cases including the reference model showed the best flow uniformity generally.

A Characteristic Heating-Energy Expend of Insulation Block System for Korea Type Passive House (한국형 패시브하우스를 위한 단열블럭시스템의 난방에너지소비 특성)

  • Kang, Jae-Sik;Choi, Gyoung-Seok;Yang, Kwan-Seop;Lee, Seung-Eon
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.603-607
    • /
    • 2009
  • About a Structure is performance external insulation is fundamantal performance for enrgy-saving. these day, most of residential structures have constructed by internal insulation method structure. The method structure internal insulation have construction and economical efficiency, but on the other hand, be generated heat loss by heat bridge especially, be generated loss heat-energy logical consequence in structure ondol. The external insulation structure method has a mert able to minimum to loss heat about heat-bridge. But the external insulation technique is unsatisfactory statues within the know-how and method of construction and materials compared with developed countries. The recently, the requirement of market related to the external insulation technique is resulted by the energy efficiency system, but it can lead to the lack of alternative technique In study on the korea type passive house building design for insulation block method of wall system has to experimental characteristic heat-energy of practice building. In result field-experimental, the heat-bridge appeared to characteristic spent heat-energy of blow 2L class and have a suffience performance it.

  • PDF