• 제목/요약/키워드: Internal discharge

검색결과 652건 처리시간 0.022초

회전기 고정자권선의 부분방전 진단용 평면 패치센서의 설계 및 실험

  • 양상현;박노준;김충식;박대희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 추계학술대회 논문집
    • /
    • pp.228-228
    • /
    • 2009
  • In stator windings of a 6.6kV rotating machine, internal discharge, corona discharge, and surface discharge are mainly caused by internal voids and insulation degradation. In the case of the discharge spark and electromagnetic pulse generated from a discharge source, we can detect it using various RF resonators like an EM sensor. In order to detect these types of electromagnetic sources, we designed and fabricated a planar patch sensor using a CST-MWS simulation, and PD signals from artificial defected stator windings were also measured by the sensor proposed in this study. Furthermore, In the results of the experiment, it showed similar performance to the HFCT sensor.

  • PDF

Characteristics of Superposed Discharge type Ozonizer by Variation of Inner Dielectric Vacuum

  • Chun, Byung-Joon;Lee, Kwang-Sik;Song, Hyun-Jig
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제3C권6호
    • /
    • pp.230-235
    • /
    • 2003
  • In this paper, a superposed discharge type ozonizer with an internal dielectric that can be made into a vacuum tube has been designed and fabricated. Ozone generation and discharge characteristics have been investigated in accordance with output voltage of power supply, flow-rate, discharge power and vacuum of inside internal dielectric. Pure oxygen was used as the supply gas of the ozonizer. Ozone concentration and ozone generation are gradually increased when discharge power is increased at the same flow-rate and they are both proportional to the vacuum level. As such, the maximum ozone concentration of 8840 ppm was obtained at vacuum 0.1 Torr and flow-rate 0.5 $\ell$/min.

고성능 유압 베인펌프 개발을 위한 내부 변동압력 측정 (I) (Tne Measurements of internal Dynamic Pressure for Development of a High Performance Oil hydraulic Vane Pump(I))

  • 정재연;정석훈
    • 대한기계학회논문집
    • /
    • 제16권2호
    • /
    • pp.191-199
    • /
    • 1992
  • This paper presents in experimental study of the dynamic internal pressure within an oil hydraulic vane pump. The measurements of the dynamic internal pressures near the vane of a pressure balance type of an oil hydraulic vane pump with intravanes has been made to provide the essential information for the study of the pump dynamics and control, the pump design and the analysis of tribological problems in the sliding components. The influences of the discharge pressure and rotating speed of the vane on the dynamic pressure in four chambers surrounding a vane have been investigated. The results indicate that the surge pressures of the chambers at the instant moment of discharge and closure are affected by the rotating speed. The pressure in the intravane chamber maintains almost constant values, which remarkably effects the pulsating discharge pressure.

주택용 BESS에 적용하기 위한 재활용 셀의 성능에 관한 연구 (A Study on the Performance of Recycled Cells for application to Residential BESS)

  • 김필중;양성수
    • 전기전자학회논문지
    • /
    • 제28권1호
    • /
    • pp.14-19
    • /
    • 2024
  • 주택용 BESS에 적용하기 위한 재활용 셀 성능을 파악하기 위해 지난 5년 동안 사용한 셀을 선택하였다. 시험에 사용된 셀의 기본 사양은 공칭 전압이 3.7[V], 공칭 용량이 2,200[mAh], 충전 전압이 4.05[V], 연속방전전류가 1[C](2,200[mA]), 연속충전전류가 0.5[C](1,100[mA]) 이다. 새 셀의 경우 내부저항은 21.3±1[mΩ]인데, 재활용 셀의 경우 평균 내부저항이 25.38[mΩ]로 나타나 약 19.1[%] 상승하였다. 충·방전 용량은 새 셀에 비해 약 18.9~19.3[%] 정도 낮게 나타났다. 내부저항과 충·방전 용량이 셀의 노화에 상호 밀접하게 연관되어 있으므로 BESS에 적용할 셀은 초기 내부저항보다 1.5배 이하이고 70[%] 이상의 충·방전 용량 성능을 갖는 제품을 사용할 필요가 있다.

고체유전체에서 발생한 부시형 전기트리에 수반된 내부 부분방전 펄스 해석 (Internal PD Pulses Analysis Accompanying with Bush-type Tree in Solid Dielectrics)

  • 강성화;홍현문;류부형
    • 한국안전학회지
    • /
    • 제15권1호
    • /
    • pp.100-105
    • /
    • 2000
  • Correlation between propagation of bush-type electrical tree and internal partial discharges(PD) was discussed. We used specimens with needle-plane electrode system made of LDPE(Low Density Polyethylene), observed inception and propagation of electrical tree by optical microscope interfaced with computer and investigated characteristics of phase resolved PD pulses accompanying with propagation of electrical tree. Electrical tree generally growed bush-type tree. PD data detected and analyzed were average discharge current and statistical operator of q-n, $\psi$- $q_{avg}$, $\psi$-n, ${\psi}-q_{max}$ distribution. Parameters used were skewness, kurtosis, average discharge phase, cross-correlation factor, asymmetry and etc. In generally, average discharge current had good linear relationship with propagation of bush type electrical tree on this experiment. Peak discharge magnitude and repetition rate were increased, but they had not good linear relationship.p.

  • PDF

Mesh 형 전극의 조밀도 변화에 따른 중첩방전형 오존발생기의 특성 (The Characteristics of a Superposed Discharge Type Ozonizer with variation of Mesh)

  • 송현직;이동헌;김태주;이광식;전병준;하장호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 C
    • /
    • pp.1834-1836
    • /
    • 2003
  • In this paper, a superposed discharge type ozonizer(SDO) has been designed and manufactured. SDO is equipped with three electrodes(central, internal and external electrodes), and it is composed of two gaps. Ozone is generated by overlapping silent discharge, which is respectively came from two gaps. At this time, Internal electrode consists of a mesh type. This paper describes the discharge and ozone generation characteristics of SDO with variation of mesh and discharge wattage.

  • PDF

변압기 부분방전 상시 감시기법에 관한 연구 (A Study on the on Line Monitoring Techniques of the Partial Discharge for Transformer)

  • 권동진;박재준
    • 한국전기전자재료학회논문지
    • /
    • 제14권12호
    • /
    • pp.1032-1040
    • /
    • 2001
  • In order to apply the partial discharge measuring technique utilizing electrical pulse to the transformer at sites, this paper describes the measuring technique obtaining only the signals due to internal partial discharge in the transformer, but the noises due to external corona which has been a major problem so far. At first, partial discharge and corona noise were simultaneously generated in the model transformer by using needle-plane electrodes and rod-sphere electrodes out of it in a high voltage laboratory, respectively. It was verified that only the partial discharge signals in the transformer could be measured by removing the noise signals from the superposed signals of partial discharges and noises on the grounding wire of the model transformer. By application to a 345kV transformer in service, it was also confirmed that the partial discharge could be on-line monitored by removing the noise signals measured by the inductance sensor on the grounding wire of a 154kV lightning arrester from the superposed signals of internal partial discharge and external corona noise measured by bushing tap coupler of the transformer.

  • PDF

6.6 kV 회전기 고정자 권선에서 부분방전 신호 검출을 위한 평면 패치 센서 설계 (The Design of a Planar Patch Sensor for Partial Discharge Diagnosis in 6.6 kV Rotating Machine Stator Windings)

  • 임광진;박노준;김희동;주영호;박대희
    • 한국전기전자재료학회논문지
    • /
    • 제21권5호
    • /
    • pp.481-485
    • /
    • 2008
  • In stator windings of 6.6 kV rotating machine, corona discharge, surface discharge and internal discharge are caused mainly by internal voids and insulation degradation. Also, if partial discharge occurs in inner-part of stator windings, it will be happened electromagnetic pulses at wide frequency range. In case of discharge spark, electromagnetic pulse generated from discharge source, and we can detect it by using various RF resonators as an EM sensor. In order to detect these kind of electromagnetic sources, we have designed and fabricated planar patch sensor using CST MWS simulation, and also PD signals from artificial defected cable were measured by our proposed sensor. Furthermore, HFCT was used as a reference sensor and compared with our proposed new planar patch sensor.

GIS내부의 부분방전신호 감도개선 및 주파수변환기법에 의한 GIS UHF Sensor 모듈의 외부노이즈차폐기법에 관한 연구 (A Study of the Method for External Noise Shielding using the GIS UHF Sensor Module Applied to the Partial Discharge Signal Sensitivity and Method of Frequency Transforming in the Internal GIS)

  • 이승민
    • 전기학회논문지
    • /
    • 제59권4호
    • /
    • pp.728-732
    • /
    • 2010
  • GIS(Gas insulated switching gear) is power equipment with excellent dielectric strength and is economy merit in high confidence and stability. Recently, because equipment of GIS was occurring problem of confidence used for a long time, partial discharge on-line diagnosis systems have been importantly recognized. Partial discharge (PD) detection is an effective means for monitoring and evaluation of dielectric condition of gas insulated system (GIS). The ultra-high-frequency (UHF) PD detection technique can detect and locate the PD sources inside GIS by detecting electromagnetic wave emitted from PD source. Therefore, real-time diagnostic system using UHF detection method has been developed for this application is being expanded gradually. However, the signal of partial discharge occurring in SF6 gas is very weak and susceptible to external noises which mainly consist of PD in air. Thus, it is important to distinguish the PD in SF6 gas more sensitively from the external noises. Unfortunately, these external noise signals and the partial discharge signals have very similar characteristics. Therefore, to solve this problem, we need the signal processing method for distinguish partial discharge signals with external noise signals for improvement of SNR(signal to noise ratio) and sensitivity. In this paper, we proposed internal signal processing method for removing external noise signals with built-in pre.amplifier and frequency conversion circuit.

폐암 환자에 대한 부가적인 침치료 효과 - 단일군, 전후, 예비임상 연구 - (Effectiveness of Additional Acupuncture Therapy for Lung Cancer Patients - A single group before-and-after, preliminary study -)

  • 김도형;전두수;박승찬;이승은;조우현;한창우;김소연;최준용;김윤성
    • 동의생리병리학회지
    • /
    • 제28권1호
    • /
    • pp.82-88
    • /
    • 2014
  • This study is a single group before-and-after study aimed to evaluate the effectiveness of additional acupuncture therapy for lung cancer patients being treated with chemotherapy. Acupuncture therapy was conducted twice a day at least for a week. The effectiveness outcome measures were the Korean Functional Assessment of Cancer Therapy (FACT-L) and the Korean Functional Assessment of Chronic Illness Therapy-Fatigue (FACIT-F) at the baseline, discharge and four weeks after discharge, and visual analogue scale(VAS) checked daily from the baseline to discharge. Ten patients were enrolled, one patient had excluded due to acute exacerbation of lung cancer. The data of nine patients showed some improvement in all of FACT-L, FACIT-F and VAS, however, there were no statistical significance. Additional acupuncture therapy for lung cancer patients treated with chemotherapy might be beneficial to improve the quality of life(QoL) and to improve fatigue. Prospective trials with complex traditional Korean medicine interventions are needed to further investigation.