• Title/Summary/Keyword: Internal conversion

Search Result 316, Processing Time 0.024 seconds

Effect of Valve Lift and Timing on Internal Exhaust Gas Recirculation and Combustion in DME Homogeneous Charge Compression Ignition Engine (DME 예혼합 압축 착화 엔진에서 밸브 양정과 개폐시기가 내부 배기가스 재순환과 연소에 미치는 영향)

  • Jang, Jin-Young;Bae, Choong-Sik
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.17 no.4
    • /
    • pp.93-100
    • /
    • 2009
  • Intake/exhaust valve timing and exhaust cam lift were changed to control the internal exhaust gas recirculation (IEGR) and combustion phase of homogeneous charge compression ignition (HCCI) engine. To measure the IEGR rate, in-cylinder gas was sampled during from intake valve close to before ignition start. The lower exhaust cam made shorter valve event than higher exhaust cam and made IEGR increase because of trapping the exhaust gas. IEGR rate was more affected by exhaust valve timing than intake valve timing and increased as exhaust valve timing advanced. In-cylinder pressure was increased near top dead center due to early close of exhaust valve. Ignition timing was more affected by intake valve timing than exhaust valve timing in case of exhaust valve lift 8.4 mm, while ignition timing was affected by both intake and exhaust valve timing in case of exhaust valve 2.5 mm. Burn duration with exhaust valve lift 2.5 mm was longer than other case due to higher IEGR rate. The fuel conversion efficiency with higher exhaust valve lift was higher than that with lower exhaust valve lift. The late exhaust and intake maximum open point (MOP) made the fuel conversion efficiency improve.

Determination of Serum Thyroxine Levels in Normal Korean Subjects and Various Thyroid Diseases (정상인 및 각종 갑상선 질환 환자의 혈청 Thyroxine)

  • Kim, Dong-Jip;Min, Byong-Sok;Bahk, Yong-Whee;Kim, Boo-Sung
    • The Korean Journal of Nuclear Medicine
    • /
    • v.3 no.2
    • /
    • pp.33-38
    • /
    • 1969
  • The serum thyroxine levels were measured by method of Tetrasorb Kit in 69 subjects including 13 subjects in euthyroid state, 31 with hyperthyroidism, 5 with hypothyroidism, 13 with nontoxic diffuse goiter, and 7 with nontoxic nodular goiter. Three parameters of the thyroid function test including thyroxine ($T_4$) levels, $^{131}I$ uptake (24 hrs) values and $PB^{131}I$ conversion ratio were correlated with clinical manifestations and courses of the disease. 1. The serum $T_4$ levels in the normal subjects were in range of $6.0{\mu}g/dl\;to\;14.4{\mu}g/dl$. (The mean $9.4{\mu}g/dl$). 2. The diagnostic compatibility of the serum $T_4$ was 93.5% in hyperthyroidism, 100% both in hypothyroidism and in nontoxic diffuse goiter, 86% in nontoxic nodular goiter, or 95.8% in the entire series. (Table 1). 3. The diagnostic compatibility of $^{131}I$ uptake (24 hrs) values and $PB^{131}I$ conversion ratio were less than the serum $T_4$ levels as summarized in Tables 2 & 3. The serum $T_4$ determination by Tetrasorb Kit is a simple, accurate and very useful test of the thyroid function.

  • PDF

Internal Oscillating Flow Field Analysis in Air Chamber of Wave Energy Conversion (파력발전장치 공기실 내 왕복유동장 해석)

  • Moon, Jae-Seung;Hyun, Beom-Soo;Hong, Key-Yong;Shin, Seung-Ho;Kim, Gil-Won
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.427-430
    • /
    • 2006
  • This paper deals with the internal oscillating flaw in air chamber and duct of an OWC-type wave energy converter by numerical analysis using commercial CFD code, FLUENT. Whole oscillating flaw from OWC-type chamber to outlet through duct was solved by unsteady analysis in order that performance of wave energy conversion was made better. Results show that whole oscillating flaw field of this system in unsteady condition. Duct shape at setting place of turbine is curved with elbow, because profile of inlet condition to turbine is important in its efficiency. This paper is found internal flaw in air chamber and duct. Also, this research was found effect of duct shape.

  • PDF

Measurement of Fractional Exhaled Nitric Oxide in Adults: Comparison of Two Different Analyzers (NIOX VERO and NObreath)

  • Kang, Sung-Yoon;Lee, Sang Min;Lee, Sang Pyo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.84 no.3
    • /
    • pp.182-187
    • /
    • 2021
  • Background: Fractional exhaled nitric oxide (FeNO) is a non-invasive marker for eosinophilic airway inflammation and a good predictor of response to corticosteroids. There is a need for a reliable and accurate measurement method, as FeNO measurements have been widely used in clinical practice. Our study aimed to compare two FeNO analyzers and derive a conversion equation for FeNO measurements in adults. Methods: We included 99 participants who had chief complaints of chronic cough and difficulty in breathing. The participants underwent concurrent FeNO measurement using NIOX VERO (Circassia AB) and NObreath (Bedfont). We compared the values of the two devices and analyzed their correlation and agreement. We then formulated an equation to convert FeNO values measured by NObreath into those obtained by NIOX VERO. Results: The mean age of the participants was 51.2±17.1 years, with a female predominance (58.6%). Approximately 60% of the participants had asthma. The FeNO level measured by NIOX VERO (median, 27; interquartile range [IQR], 15-45) was significantly lower than that measured by NObreath (median, 38; IQR, 22-58; p<0.001). There was a strong positive correlation between the two devices (r=0.779, p<0.001). Additionally, Bland-Altman plots and intraclass correlation coefficient demonstrated a good agreement. Using linear regression, we derived the following conversion equation: natural log (Ln) (NObreath)=0.728×Ln (NIOX VERO)+1.244. Conclusion: The FeNO values of NIOX VERO and NObreath were in good agreement and had positive correlations. Our proposed conversion equation could help assess the accuracy of the two analyzers.

The Method of Effective DB Conversion and Related System Development for the Integrated KORMARC Format - Based on the Case of Sogang University Library - (통합서지형 KORMARC의 도입을 위한 효과적인 DB 변환과 시스템 구축 방안 - 서강대학교 도서관의 '자체 변환 방식'을 중심으로 -)

  • Lee, Kyu-Youn
    • Journal of Korean Library and Information Science Society
    • /
    • v.45 no.3
    • /
    • pp.93-117
    • /
    • 2014
  • The goal of this study is to seek for the method of effective DB conversion and related system development for the integrated KORMARC Format on the basis of the case of Sogang University Library. Since the integrated KORMARC bibliographic format was established, libraries have been converting bibliographic DB according to the new format. Loyola Library of Sogang University internally proceeded DB conversion using bibliographic DB convertor, which was developed and customized with a system vendor for Sogang University Library. The internal conversion enabled to correct or supplement bibliographic data errors. Besides, it enhanced stability of conversion and shortened the project time by adopting sampling conversion method. It was effective to reduce the additional work for DB quality maintenance, so this kind of conversion is recommendable to the library that has limited manpower for manual data correction.

No-Touch Radiofrequency Ablation Using Twin Cooled Wet Electrodes for Recurrent Hepatocellular Carcinoma Following Locoregional Treatments

  • Seong Jun Hong;Jae Hyun Kim;Jeong Hee Yoon;Jeong Hoan Park;Jung-Hwan Yoon;Yoon Jun Kim;Su Jong Yu;Eun Ju Cho;Jeong Min Lee
    • Korean Journal of Radiology
    • /
    • v.25 no.5
    • /
    • pp.438-448
    • /
    • 2024
  • Objective: To evaluate the therapeutic outcomes of no-touch radiofrequency ablation (NT-RFA) using twin cooled wet (TCW) electrodes in patients experiencing recurrent hepatocellular carcinoma (HCC) after undergoing locoregional treatments. Materials and Methods: We conducted a prospective, single-arm study of NT-RFA involving 102 patients, with a total of 112 recurrent HCCs (each ≤ 3 cm). NT-RFA with TCW electrodes was implemented under the guidance of ultrasonography (US)-MR/CT fusion imaging. If NT-RFA application proved technically challenging, conversion to conventional tumor puncture RFA was permitted. The primary metric for evaluation was the mid-term cumulative incidence of local tumor progression (LTP) observed post-RFA. Cumulative LTP rates were estimated using the Kaplan-Meier method. Multivariable Cox proportional hazard regression was used to explore factors associated with LTP. Considering conversion cases from NT-RFA to conventional RFA, intention-to-treat (ITT; including all patients) and per-protocol (PP; including patients not requiring conversion to conventional RFA alone) analyses were performed. Results: Conversion from NT-RFA to conventional RFA was necessary for 24 (21.4%) out of 112 tumors. Successful treatment was noted in 111 (99.1%) out of them. No major complications were reported among the patients. According to ITT analysis, the estimated cumulative incidences of LTP were 1.9%, 6.0%, and 6.0% at 1, 2, and 3 years post-RFA, respectively. In PP analysis, the cumulative incidence of LTP was 0.0%, 1.3%, and 1.3% at 1, 2, and 3 years, respectively. The number of previous locoregional HCC treatments (adjusted hazard ratio [aHR], 1.265 per 1 treatment increase; P = 0.004), total bilirubin (aHR, 7.477 per 1 mg/dL increase; P = 0.012), and safety margin ≤ 5 mm (aHR, 9.029; P = 0.016) were independently associated with LTP in ITT analysis. Conclusion: NT-RFA using TCW electrodes is a safe and effective treatment for recurrent HCC, with 6.0% (ITT analysis) and 1.3% (PP analysis) cumulative incidence of LTP at 2 and 3-year follow-ups.

Development of the Switching Mode Conversion Type Pulse Charger for the Lead Battery of Solar Cell Generator Equipment by Fly-Back Converter Method (플라이백 컨버터방법에 의한 태양광발전설비의 납축전지 스위칭모드 전환형 펄스충전기 개발)

  • Shin, Choon-Shik;An, Young-Joo;Kim, Dong-Wan
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.1
    • /
    • pp.20-26
    • /
    • 2009
  • In this paper, the switching mode conversion type pulse charger by fly-back converter method for lead battery of the solar cell generator equipment is proposed. And we propose the control circuit and design method of insulated switching mode convert type pulse charger by fly-back convert method in the lead battery. The proposed system can minimize the current consumption by digital pulse. Also the proposed system can generate the constant 10[KHz] frequency, transmit the signal with main control system in the power control system. And it supervises the state of lead battery using one chip micro processor. The proposed the switching mode conversion type pulse charger by the fly-back converter method can charge fast and stabilize lead battery with nominal value 12[V], 20[AH]. Also we propose the design procedure of the power control circuit for turn ratio of fly-back inductor and determining method of values such as the charging current, bulk current, partial current, over current value and fixed charging voltage. The experiment results for the voltage and current wave for partial, bulk, over and fixed charging period show the good charging effect and performance. And the PCB and internal coupling diagram of the switching mode conversion type pulse charger by fly-back converter method is presented.

The conversion of ammonium uranate prepared via sol-gel synthesis into uranium oxides

  • Schreinemachers, Christian;Leinders, Gregory;Modolo, Giuseppe;Verwerft, Marc;Binnemans, Koen;Cardinaels, Thomas
    • Nuclear Engineering and Technology
    • /
    • v.52 no.5
    • /
    • pp.1013-1021
    • /
    • 2020
  • A combination of simultaneous thermal analysis, evolved gas analysis and non-ambient XRD techniques was used to characterise and investigate the conversion reactions of ammonium uranates into uranium oxides. Two solid phases of the ternary system NH3 - UO3 - H2O were synthesised under specified conditions. Microspheres prepared by the sol-gel method via internal gelation were identified as 3UO3·2NH3·4H2O, whereas the product of a typical ammonium diuranate precipitation reaction was associated to the composition 3UO3·NH3·5H2O. The thermal decomposition profile of both compounds in air feature distinct reaction steps towards the conversion to U3O8, owing to the successive release of water and ammonia molecules. Both compounds are converted into α-U3O8 above 550 ℃, but the crystallographic transition occurs differently. In compound 3UO3·NH3·5H2O (ADU) the transformation occurs via the crystalline β-UO3 phase, whereas in compound 3UO3·2NH3·4H2O (microspheres) an amorphous UO3 intermediate was observed. The new insights obtained on these uranate systems improve the information base for designing and synthesising minor actinide-containing target materials in future applications.

Development of the Power Conversion Controller for Electric Vehicle (전기자동차용 전력변환 제어기 개발)

  • Oh, Yong-Seung;Kim, Hee-Jun;Lee, Sang-Taek
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.9
    • /
    • pp.18-25
    • /
    • 2012
  • Recently, the depletion of fossil fuel carbon dioxide emissions due to limitations in the internal combustion engine vehicles is rising concern about electric vehicle. Neighborhood Electric Vehicle(NEV) is maximum speed 60km/h and one day driving distances less than 80km. In this paper, Power Conversion Controller is proposed for Neighborhood Electric Vehicle. To verify the developed Power conversion Controller, Test performed integration test, max load, power density, efficiency. Confirmed that the vehicle can be applied.

Super-High-Speed Lightwave Demodulation using the Nonlinearities of an Avalanche Photodiode

  • Park, Young-Kyu
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.2C no.5
    • /
    • pp.273-278
    • /
    • 2002
  • Even though the modulating signal frequency of the light is too high to detect directly, the signal can be extracted by frequency conversion at the same time as the detection by means of the non-linearity of the APD. An analysis is presented for super-high-speed optical demodulation by an APD with electronic mixing. A normalized gain is defined to evaluate the performance of the frequency conversion demodulation. The nonlinear effect of the internal capacitance was included in the small signal circuit analysis. We showed theoretically and experimentally that the normalized gain is dependent on the down converted difference frequency component. In the experiment, the down converted different frequency outputs became larger than the directly detected original signal for the applied local signal of 20㏈m.