• Title/Summary/Keyword: Internal Voltage Drop

Search Result 32, Processing Time 0.026 seconds

A Study on Operation Method of Power Distribution System Integrated with Dispersed Generation System (분산형전원이 도입된 복합배전계통의 운용방안에 대한 고찰)

  • Kim, Jae-Eon;Jo, Seong-Hyeon
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.48 no.6
    • /
    • pp.692-698
    • /
    • 1999
  • This paper analyzes the effect of DGS(Dispersed Generation System) on the voltage regulation of the traditional distribution system of which the voltage is controlled by the bank LDC(Line Drop Compensator). Through the simulation results for 22.9kV class distribution system with DGSs, some general relationships among the operating power factor and introduction limit of DGS, and the sending-end reference voltage determined by internal setting coefficients of the LDC are derived. Those relationships are that the introduction limit of DGS increases as the power factor of DGS goes from lagging to leading and also as the allowance of the sending-end reference voltage increases. From the relationships, a operation method of the power distribution system integrated with DGSs is proposed from the view point of the operating power factor of DGS and new voltage regulation method.

  • PDF

Improved Load Sharing Rate in Paralleled Operated Lead Acid Batteries (납 축전지의 병렬운전시 부하분담률 개선)

  • 반한식;최규하
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.6 no.1
    • /
    • pp.34-42
    • /
    • 2001
  • A battery is the device that transforms the chemical energy into the direct-current electrical energy directly without a mechanical process. Unit cells are connected in series to obtain the required voltage, while being connected in parallel to organize capacity for load current and to decrease the internal resistance for corresponding the sudden shift of the load current. Because the voltage droop down in one set of battery is faster than in tow one, it amy result in the low efficiency of power converter with the voltage drop and cause the system shutdown. However, when the system being driven in parallel, a circular-current can be generated. The changing current differs in each set of battery because the system including batteries, rectifiers and loads is connected in parallel and it makes the charge voltage constant. It is shown that, as a result the new batteries are heated by over-charge and over-discharge, and the over charge current increases rust of the positive grid and consequently shortens the lifetime of the new batteries. The difference between the new batteries and old ones is the amount of internal resistance. In this paper, we can detect the unbalance current using the micro-processor and achieve the balance current by adjusting resistance of each set. The internal resistance of each set becomes constant and the current of charge and discharge comes to be balanced by inserting the external resistance into the system and calculating the change of internal resistance.

  • PDF

A Study on the knock and misfire detection system using by Spark-plug in a Gasoline Engine (가솔린기관에서 스파크플러그를 이용한 노크 및 실화의 동시검출시스템 개발에 관한 연구)

  • 조민석;박재근;황재원;채재우
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.8 no.1
    • /
    • pp.23-31
    • /
    • 2000
  • Knock and misfire, kinds of abnormal combustion, are highly undesirable effect on the internal combustion engine. So, it is important to detect these avnormal combuition and control the ignition timing etc. to avoid these mal-effect factors in real engine system. In this study, the system which detects the knock and the misfire using by spark plug is presented. This system is based on the effect of modulation breakdown voltage(BDV) between the spark gaps. The voltage drop between spark plug electrodes, when an electrical breakdown is initiated, depends on the temperature and pressure in combustion chamber. So, we can detect knock and misfire that produce changes in gas temperature and pressure (consequently, its density) using by BDV signal change which carries information about the character of combustion.

  • PDF

Output Noise Reduction Technique Based on Frequency Hopping in a DC-DC Converter for BLE Applications

  • Park, Ju-Hyun;Kim, Sung Jin;Lee, Joo Young;Park, Sang Hyeon;Lee, Ju Ri;Kim, Sang Yun;Kim, Hong Jin;Lee, Kang-Yoon
    • IEIE Transactions on Smart Processing and Computing
    • /
    • v.4 no.5
    • /
    • pp.371-378
    • /
    • 2015
  • In this paper, a different type of pulse width modulation (PWM) control scheme for a buck converter is introduced. The proposed buck converter uses PWM with frequency hopping and a low quiescent.current low dropout (LDO) voltage regulator with a power supply rejection ratio enhancer to reduce high spurs, harmonics and output voltage ripples. The low quiescent.current LDO voltage regulator is not described in this paper. A three-bit binary-to-thermometer decoder scheme and voltage ripple controller (VRC) is implemented to achieve low voltage ripple less than 3mV to increase the efficiency of the buck converter. An internal clock that is synchronized to the internal switching frequency is used to set the hopping rate. A center frequency of 2.5MHz was chosen because of the bluetooth low energy (BLE) application. This proposed DC-DC buck converter is available for low-current noise-sensitive loads such as BLE and radio frequency loads in portable communications devices. Thus, a high-efficiency and low-voltage ripple is required. This results in a less than 2% drop in the regulator's efficiency, and a less than 3mV voltage ripple, with -26 dBm peak spur reduction operating in the buck converter.

Parameter Measurement Method for Super Capacitor Failure Diagnosis and Application of Voltage Sag Compensation System Using Super Capacitor (수퍼 커패시터의 고장진단을 위한 파라미터의 측정기법과 순시전압강하 보상장치에의 응용사례)

  • Shon, Jin-Geun
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.8 no.6
    • /
    • pp.173-179
    • /
    • 2009
  • Recently, the super capacitor(EDLC) which has drawn attention as a new energy storage element has a lot of advantage such as no maintenance, long lifetime and quick charge/discharge characteristics with large current. The objective of this paper is propose a parameter measurement method to detect the changes in equivalent series resistor (ESR) and the capacitance value of a super capacitor in order to analysis the internal characteristic and worn-out state of a super capacitor. For proposed method, only the capacitor voltage measurement using simple analog switch is required. In addition, experimental results of voltage sag compensation system in order to compensate the input voltage drop during short-term power interruption adopted super capacitor are presented.

  • PDF

Degradation Comparison of Hydrogen and Internally Reformed Methane-Fueled Solid Oxide Fuel Cells

  • Kim, Young Jin;Lee, Hyun Mi;Lim, Hyung-Tae
    • Journal of the Korean Ceramic Society
    • /
    • v.53 no.5
    • /
    • pp.483-488
    • /
    • 2016
  • Anode supported solid oxide fuel cells (SOFCs), consisting of Ni+YSZ anode, YSZ electrolyte, and LSM+YSZ cathode, were fabricated and constant current tested with direct internal reforming of methane (steam to carbon ratio ~ 2) as well as hydrogen fuel at $800^{\circ}C$. The cell, operated under direct internal reforming conditions, showed relatively rapid degradation (~ 1.6 % voltage drop) for 95 h; the cells with hydrogen fuel operated stably for 170 h. Power density and impedance spectra were also measured before and after the tests, and post-test analyses were conducted on the anode parts using SEM / EDS. The results indicate that the performance degradation of the cell operated with internal reforming can be attributed to carbon depositions on the anode, which increase the resistance against anode gas transport and deactivate the Ni catalyst. Thus, the present study shows that direct internal reforming SOFCs cannot be stably operated even under the condition of S/C ratio of ~ 2, probably due to non-uniform mixture (methane and steam) gas flow.

A study on the on-load torque measurement for three phase induction motor (삼상유도전동기의 부하시 토오크 측정에 관한 연구)

  • 이승원;김은배;황석영;강석윤
    • 전기의세계
    • /
    • v.30 no.11
    • /
    • pp.734-746
    • /
    • 1981
  • This paper suggests on-load torque measurement for 3 phase induction motors by input -voltage and current utilizing symmetric coordinate analysis technique on the basis of the induction motor equivalent circuit. In this paper, two cases are treated with, i.e, one is the case where the motors' exciting current and primary leakage impedance voltage drop are compensated automatically, adopting the ideal wattmeter whose current coil impedance and voltage coil impedance are 0 and .inf. respectively, and the other is the case where non-ideal wattmeter is adopted and the compensation above is made by computation. As a result of the case study, following conclusions are obtained. 1) By proper combination of the error propagation law and the limit of power consumption, the desirable overall measurement error of the apparatus can be obtained on the basis of the inherent errors of CT and PT. 2) The measurement error is larger in current simulation circuit than in voltage simulation circuit. 3) Between the two cases, the latter is more advantageous than the former from the viewpoint of feasibility and the measurement error. 4) As the attachment of Ammeter in the current simulation circuit influences the measurement error considerably, its internal impedance should be large considerably. 5) The larger the consumption power of the apparatus is, the easier the feasibility is.

  • PDF

A Protection Algorithm Discriminating Between Internal and External Faults for Wind Farms (풍력발전단지 보호를 위한 내외부 고장 판별 알고리즘)

  • Kwon, Young-Jin;Kang, Sang-Hee
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.5
    • /
    • pp.854-859
    • /
    • 2007
  • A wind farm consists of many wind generator(WG)s therefore, it is generally a complex power system. A wind farm as a distributed generation(DG) affects utility power system. If a conventional protection schemes are applied, it is difficult to detect faults correctly and the schemes can't provide proper coordination in some cases. This paper presents a protection algorithm for a wind farm which consists of a looped collection circuit. Because the proposed algorithm can distinguish between an internal fault and an external fault in a wind farm, The proposed algorithm can disconnect the faulted section in a wind farm. This algorithm is based on an overcurrent protection technique with the change of the ratio of the output current of a generator to the current of the looped line connected to each generator to collect the each generator's power. In addition, operating time of the algorithm is shortened by using the voltage drop at a generator collection point. The performance of the proposed algorithm was verified under various fault conditions using PSCAD/EMTDC simulations.

Development of Aging Diagnosis Device Through Real-time Battery Internal Resistance Measurement

  • Kim, Sang-Bum;Lee, Sang-Hyun
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.14 no.2
    • /
    • pp.129-135
    • /
    • 2022
  • Currently, the rapid growth of electric vehicles and the collection and disposal of waste batteries are becoming a social problem. The purpose of this paper is to propose a fast and efficient battery screening method through a safe inspection and storage method according to the collection and storage of waste batteries of electric vehicles. In addition, as the resistance inside the waste battery increases, an instantaneous voltage drop occurs, and there is a risk of overcharging and overdischarging compared to the initial state of the battery. Accordingly, there are great difficulties in operation, so the final goal of this study is to develop a device for diagnosing aging through real-time battery internal resistance measurement. Final result As a result of simulation of the internal resistance measurement test circuit through external impedance (AC), the actual simulation value was 0.05Ω, RS = Vrms / Irms => Vrms = 8.0036mV, Irms = 162.83Ma. Substitute the suggested method. The result was calculated as Rs = 0.0495Ω. It is possible to measure up to 64 impedances inside the aging diagnostic equipment that enables real-time monitoring of the developed battery cells, and the range can be changed according to the application method.

Calculation of the Harmonic Emission Limit for low-Voltage Electrical Equipment (국내 저압 전기기기의 고조파 유출 제한값 산정)

  • Kang, Moon-Ho;Song, Yang-Hoi;Lee, Heung-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.10
    • /
    • pp.56-61
    • /
    • 2008
  • Because the harmonic disturbance characteristic which makes voltage drop and the deterioration of instantaneous power quality in electrical power system overheats the NGR and the customer capacitor and malfunctions the OCGR and AMR, it is necessary for electric power company to take active measures to reduce this disturbance. International Electrotechnical Commission(IEC) 61000-3-2 specifies limits for harmonic current emissions generated by low voltage(LV) electrical equipment whose input current $\leq$ 16(A) per phase. Analysis shows that limits for Class A equipment in IEC are calculated using the reference impedance of LV system and maximum permissible voltage and limits for other Classes are also calculated based on limits for Class A. Therefore we have calculated four(4) internal limits for LV electrical equipment using the korea reference impedance and maximum permissible voltage in this paper.