• 제목/요약/키워드: Internal Vibration Measurement

검색결과 61건 처리시간 0.029초

공기스프링을 이용한 방진테이블의 능동 제어 (Active Control of Vibration Isolation Table Using Air-spring)

  • 안채헌;임광혁;진경복;임경화
    • 한국소음진동공학회논문집
    • /
    • 제17권7호
    • /
    • pp.565-571
    • /
    • 2007
  • In the process of accurate manufacture and measurement, it is necessarily required to isolate external or internal vibration due to external disturbance and internal actuators. The higher vibration isolation system gets damping around resonance, the better it is generally. This paper analyzes the performance of an existing passive air-spring for vibration isolation table by using experiment and simulation. Optimal design for a passive air spring can be obtained by tuning the size of the orifice. Also design for an active isolation system is carried out by applying PID controller and considering non-linearity of pneumatic characteristics with help of look-up table. We have developed the active vibration isolation table with the better isolation performance.

공기스프링을 이용한 방진 테이블의 능동 제어 (Active Control of Vibration Isolation Table Using Air-spring)

  • 안채헌;임광혁;권혁진;정진훈;배윤화;진경복;임경화
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 춘계학술대회논문집
    • /
    • pp.831-836
    • /
    • 2006
  • In the process of accurate manufacture and measurement, it is necessarily required to isolate external or internal vibration due to external disturbance and internal actuators. The higher vibration isolation system gets damping around resonance, the better it is generally. This paper analyzes the performance of an existing passive air-spring for vibration isolation table by using experiment and simulation. Optimal design for a passive air spring can be obtained by tuning the size of the orifice. Also design for an active isolation system is carried out by applying PID controller and considering non-linearity of pneumatic characteristics with help of look-up table. We have developed the active vibration isolation table with the better isolation performance.

  • PDF

Effects of Active Vibration Exercise on Trunk Muscle Activity, Balance, and Activities of Daily Living in Patients with Chronic Stroke

  • Lee, Dong-Kyu;Kim, Eun-Kyung
    • The Journal of Korean Physical Therapy
    • /
    • 제30권4호
    • /
    • pp.146-150
    • /
    • 2018
  • Purpose: This study aimed to investigate the effect of active vibration exercise on trunk muscle activity, balance, and activities of daily living in patients with chronic stroke. Methods: Twenty-four patients with chronic stroke were randomly assigned to an experimental (n=12) or a control (n=12) group. The experimental group performed an active vibration exercise workout for 20 minutes a day five times a week for 4 weeks using a flexi-bar. Trunk muscle activity was measured using surface electromyography. Balance was measured using the Berg balance scale. Activities of daily living were measured using the functional independence measure. Results: The intragroup comparison showed significant differences in the rectus abdominis, internal oblique, and external oblique muscle activity values, Berg balance scale score, and functional independence measurement values in the experimental group. The intergroup comparison showed that differences in the rectus abdominis and internal oblique external oblique muscle values, Berg balance scale score, and functional independence measurement value for the experimental group were significantly related to those in the control group. Conclusion: Based on these results, this study proved that the active vibration exercise effectively improved trunk muscle activity, balance, and activities of daily living in patients with chronic stroke.

집속초음파 자극기의 성능평가를 위한 팬텀 내부온도 측정 (Measurement of Internal Temperature Distribution for the Evaluation of Focused Ultrasound (FUS) Stimulation Devices)

  • 도일;조주형;김성목;백경민;김용태;박승민
    • 대한의용생체공학회:의공학회지
    • /
    • 제43권3호
    • /
    • pp.147-152
    • /
    • 2022
  • This research is to measure real-time temperature distribution inside a tissue-mimicking phantom for the safety and effectiveness evaluations of focused ultrasound (FUS) device capable of linear scanning stimulation. Since the focusing area of the FUS stimulation device is smaller than diameter of conventional thermal probe and keeps moving, it is impossible to monitor temperature distribution inside the phantom. By using the phantom with a thin film temperature sensor array inserted, real-time temperature change caused by the FUS device was measured. The translation of the measured temperature peak was also tracked successfully. The present phantom had been experimentally proven to be applicable to validate the performance and safety of the therapeutic ultrasound devices.

차음성능 측정에 있어서의 암소음의 영향의 저감 (1) (Recuction of the Influence of Background Noise in Sound Insulation Measurement)

  • 염성곤;다치바나히데끼
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 춘계학술대회논문집
    • /
    • pp.495-498
    • /
    • 2004
  • In the sound insulation measurements, the influence of background (extraneous) noise is often serious problem and how to reduce its effect and to improve the signal-to-noise(S/N) ratio is an important theme. As the background noise, such extraneous noises as road traffic noise and machine noise often disturb the measurement. In laboratory measurements on specimens with high sound insulation performances, even the internal noise of the measurement system can become a problem. To improve the signal-to-noise ratio and to improve the measurement accuracy, various kinds of digital signal processing techniques can be applied. In this paper, four kinds of digital signal processing techniques are applied and their effectiveness is examined by a simple sound insulation measurement.

  • PDF

공기스프링을 이용한 방진 테이블의 능동 제어

  • 임경화;진경복;안채헌;박정근
    • 한국반도체및디스플레이장비학회:학술대회논문집
    • /
    • 한국반도체및디스플레이장비학회 2006년도 추계학술대회 발표 논문집
    • /
    • pp.184-189
    • /
    • 2006
  • In the process of accurate manufacture and measurement, it is necessarily required to isolate external or internal vibration due to external disturbance and internal actuators. The higher vibration isolation system gets damping around resonance, the better it is generally. This paper analyzes the performance of an existing passive air-spring for vibration isolation table by rising experiment and simulation. Optimal design for a passive air spring can be obtained by fluting the size of the orifice. Also design for an active isolation system is carried out by applying PID controller and considering non-linearity of pneumatic characteristics with help of look-up table. We have developed the act ive vibration isolation table wi th the bet ter isolation performance.

  • PDF

차음성능 측정에 있어서의 암소음의 영향의 저감 (2) (Recuction of the Influence of Background Noise in Sound Insulation Measurement)

  • 염성곤;다치바나 히데끼
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 추계학술대회논문집
    • /
    • pp.441-444
    • /
    • 2004
  • In the sound insulation measurements, the influence of background (extraneous) noise is often serious problem and how to reduce its effect and to improve the signal-to-noise(S/N) ratio is an important theme. As the background noise, such extraneous noises as road traffic noise and machine noise often disturb the measurement. In laboratory measurements on specimens with high sound insulation performances, even the internal noise of the measurement system can become a problem. To improve the signal-to-noise ratio and to improve the measurement accuracy, various kinds of digital signal processing techniques can be applied. In this paper, four kinds of digital signal processing techniques are applied and their effectiveness is examined through field measurements.

  • PDF

Dynamic Strain Gage를 이용한 제진합금의 제진특성 측정 (Damping Property Measurement of Damping Alloy by Dynamic Strain Gage)

  • 이규환;조권구;이봉직;심명철
    • 한국재료학회지
    • /
    • 제4권5호
    • /
    • pp.502-509
    • /
    • 1994
  • dynamic strain gage와 12bit AD(analog to digital converter)를 이용한 새로운 제진특성 측정 장치를 제작하였다. 이 장치를 이용하여 일반재료와 고제진재료의 제진특성을 연구하였다. 또한 열처리 조건, 초기 진동 진폭, 그리고 내부응력의 변화에 따른 SDC(specific damping capacity)변화에 관하여 연구하였다. 일반재료와 제진재료의 비교에서, 제진재료는 진동을 가한 후 0.4초 이내에 진동 진폭이 거의 사라졌지만, 같은 시간에 일반재료의 진동 진폭은 거의 감소하지 않았다. Fe-16wt. %Cr계 합금의 제진 특성은 노냉일 때 SDC max 가 40%이상이었고, Fe-5.5wt.%Ai합금의 제진 특성은 공냉일 때 SDC max값이 30%이상이었다. 초기 진동 진폭이 증가할수록 최대 제진 특성치는 낮은 진동 진폭 영역으로 이동하였다. 제진 특성은 내부 응력이 증가할수록 급격한 감소를 보였으며, 본 연구에서 개발한 제진측정 장치는 낮은 진동 진폭의 영역에서 정확한 제진 특성 측정이 가능하였다.

  • PDF

평판 인텐시티 측정을 통한 근접장 음향 인텐시티와 손실 계수 측정법 (Measurement of Near Field Sound Intensity and Loss Factor Using Plate Intensity Measurement)

  • 김용조;김양한
    • 소음진동
    • /
    • 제7권4호
    • /
    • pp.589-596
    • /
    • 1997
  • A energy equation for a thin plate and surrounding fluid is derived. The equation essentially determines the relation between internal loss of thin plate, energy of acoustic radiation, and structure intensity. We attempted to use this relation to measure internal loss of thin plate. The significance of this approach is that internal loss at any point of a thin plate can be measured. The quality of this measure is dicated by the accuracy of associated measurement systems such as structure and acoustic intensity measurements. A strain gauge bridge system has been developed to measure structure intensity of thin plate. Its performance is tested by experiments.

  • PDF